Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 12.853
1.
Acta Biochim Pol ; 71: 12433, 2024.
Article En | MEDLINE | ID: mdl-38721304

The study aimed to determine the osteointegration markers after dental implantation and evaluate their predictive value. The study was performed on 60 practically healthy persons who needed teeth rehabilitation using dental implants. The conical-shaped implants (CI) and hexagonal implants (HI) were used. The content of Osteopontin (OPN), Osteocalcin (OC), Alkaline Phosphatase (ALP), Osteoprotegerin (OPG), and nitric oxide (NO) was determined in patients' gingival crevicular fluid (GCF) and peri-implant sulcular fluid (PISF), collected 1, 3, and 6 months after implantation. During the 3-6 months of observation level of OPN increased in patients with CIs (<50 years > 50 years) and HIs (<50 years) (CI: <50 years F = 36.457, p < 0.001; >50 years F = 30.104, p < 0.001; HI < 50 years F = 2.246, p < 0.001), ALP increased in patients with CIs (<50 years: F = 19.58, p < 0.001; >50 years: F = 12.01; p = 0.001) and HIs (<50 years) (F = 18.51, p < 0.001), OC increased in patients <50 years (CI: F = 33.72, p < 0.001; HI: F = 55.57, p < 0.001), but in patients >50 years - on the 3 days month (CI: F = 18.82, p < 0.001; HI: F = 26.26, p < 0.001), but sharply decreased at the end of sixth month. OPG increased during 1-3 months of the observation in patients <50 years (CI: F = 4.63, p = 0.037; HI: F = 2.8927, p = 0.046), but at the end of the sixth month returned to the initial level; NO content in PISF increased in patients with CI (>50 years) during 1-6 months of the observation (F = 27.657, p < 0.001). During the post-implantation period, age-related differences in osteointegration were observed. Patients <50 years old had relatively high levels of OPN, ALP, OC, and OPG in PISF, resulting in less alveolar bone destruction around dental implants and more intensive osteointegration. These indicators may be used as biological markers for monitoring implant healing. The process of osseointegration was more intense in CIs due to their comparatively high mechanical loading.


Alkaline Phosphatase , Biomarkers , Dental Implants , Gingival Crevicular Fluid , Osseointegration , Osteocalcin , Osteopontin , Osteoprotegerin , Humans , Middle Aged , Biomarkers/metabolism , Female , Male , Osteoprotegerin/metabolism , Gingival Crevicular Fluid/metabolism , Alkaline Phosphatase/metabolism , Osteocalcin/metabolism , Adult , Osteopontin/metabolism , Prognosis , Nitric Oxide/metabolism , Dental Implantation/methods , Time Factors
2.
Int J Implant Dent ; 10(1): 24, 2024 May 09.
Article En | MEDLINE | ID: mdl-38722448

PURPOSE: The objective of the present study was to ascertain the effect of immediate occlusal loading after implant placement on osseointegration and the micro/nanostructure of the surrounding bone. METHODS: After extraction of a rat maxillary right second molar, an implant was placed immediately with initial fixation (2 N< ). The implants were placed to avoid occlusal loading due to mastication, and in the loaded group, a superstructure was fabricated and subjected to occlusal loading. Bone morphometry, collagen fiber anisotropy, and biological apatite (BAp) crystallite alignment were quantitatively evaluated in both groups after extraction and fixation of the jaw bone at Days 7 and 21 after surgery. RESULTS: Osseointegration was observed in both groups. Bone morphometry showed significant differences in bone volume, trabecular number, trabecular thickness and bone mineral density (BMD) at Days 21 postoperatively (P < 0.05). A significant difference was also found in the trabecular separation at Days 7 postoperatively (P < 0.05). In the evaluation of collagen fiber anisotropy, collagen fiber bundles running differently from the existing bone were observed in both groups. In terms of BAp crystallite alignment, a specific structure was observed in the reconstructed new bone after implantation, and preferential orientation of BAp crystallite alignment was observed in the longitudinal direction of the implants in the Day 21 postoperative loaded group. CONCLUSION: When sufficient initial fixation is achieved at the time of dental implant placement, then the applied masticatory load may contribute to rapidly achieving not only bone volume, but also adequate bone quality after implant placement.


Immediate Dental Implant Loading , Osseointegration , Animals , Rats , Osseointegration/drug effects , Male , Bone Density/physiology , Dental Implants , Rats, Wistar , Maxilla/surgery , Collagen/metabolism , X-Ray Microtomography
3.
Biomed Mater ; 19(4)2024 May 22.
Article En | MEDLINE | ID: mdl-38740037

The purpose of this study was to construct a rutin-controlled release system on the surface of Ti substrates and investigate its effects on osteogenesis and osseointegration on the surface of implants. The base layer, polyethylenimine (PEI), was immobilised on a titanium substrate. Then, hyaluronic acid (HA)/chitosan (CS)-rutin (RT) multilayer films were assembled on the PEI using layer-by-layer (LBL) assembly technology. We used scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and contact angle measurements to examine all Ti samples. The drug release test of rutin was also carried out to detect the slow-release performance. The osteogenic abilities of the samples were evaluated by experiments on an osteoporosis rat model and MC3T3-E1 cells. The results (SEM, FTIR and contact angle measurements) all confirmed that the PEI substrate layer and HA/CS-RT multilayer film were effectively immobilised on titanium. The drug release test revealed that a rutin controlled release mechanism had been successfully established. Furthermore, thein vitrodata revealed that osteoblasts on the coated titanium matrix had greater adhesion, proliferation, and differentiation capacity than the osteoblasts on the pure titanium surface. When MC3T3-E1 cells were exposed to H2O2-induced oxidative stressin vitro, cell-based tests revealed great tolerance and increased osteogenic potential on HA/CS-RT substrates. We also found that the HA/CS-RT coating significantly increased the new bone mass around the implant. The LBL-deposited HA/CS-RT multilayer coating on the titanium base surface established an excellent rutin-controlled release system, which significantly improved osseointegration and promoted osteogenesis under oxidative stress conditions, suggesting a new implant therapy strategy for patients with osteoporosis.


Coated Materials, Biocompatible , Hyaluronic Acid , Osseointegration , Osteoblasts , Osteogenesis , Osteoporosis , Prostheses and Implants , Rutin , Surface Properties , Titanium , Animals , Titanium/chemistry , Rutin/chemistry , Rutin/pharmacology , Osteogenesis/drug effects , Rats , Osteoporosis/drug therapy , Mice , Osteoblasts/drug effects , Osteoblasts/cytology , Osteoblasts/metabolism , Osseointegration/drug effects , Hyaluronic Acid/chemistry , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Oxidation-Reduction , Chitosan/chemistry , Female , Rats, Sprague-Dawley , Cell Adhesion/drug effects , Spectroscopy, Fourier Transform Infrared , Cell Differentiation/drug effects , Microscopy, Electron, Scanning , Cell Proliferation/drug effects , Polyethyleneimine/chemistry , 3T3 Cells , Oxidative Stress/drug effects , Layer-by-Layer Nanoparticles
4.
J Rehabil Med ; 56: jrm34141, 2024 May 21.
Article En | MEDLINE | ID: mdl-38770700

OBJECTIVE: To describe and evaluate the combination of osseointegration and nerve transfers in 3 transhumeral amputees. DESIGN: Case series. PATIENTS: Three male patients with a unilateral traumatic transhumeral amputation. METHODS: Patients received a combination of osseointegration and targeted muscle reinnervation surgery. Rehabilitation included graded weight training, range of motion exercises, biofeedback, table-top prosthesis training, and controlling the actual device. The impairment in daily life, health-related quality of life, and pain before and after the intervention was evaluated in these patients. Their shoulder range of motion, prosthesis embodiment, and function were documented at a 2- to 5-year follow-up. RESULTS: All 3 patients attended rehabilitation and used their myoelectric prosthesis on a daily basis. Two patients had full shoulder range of motion with the prosthesis, while the other patient had 55° of abduction and 45° of anteversion. They became more independent in their daily life activities after the intervention and incorporated their prosthesis into their body scheme to a high extent. CONCLUSION: These results indicate that patients can benefit from the combined procedure. However, the patients' perspective, risks of the surgical procedures, and the relatively long rehabilitation procedure need to be incorporated in the decision-making.


Amputees , Artificial Limbs , Nerve Transfer , Osseointegration , Range of Motion, Articular , Humans , Male , Osseointegration/physiology , Adult , Amputees/rehabilitation , Nerve Transfer/methods , Range of Motion, Articular/physiology , Bionics , Treatment Outcome , Muscle, Skeletal , Middle Aged , Humerus/surgery , Quality of Life , Amputation, Traumatic/rehabilitation , Amputation, Traumatic/surgery , Activities of Daily Living
5.
Iran Biomed J ; 28(2&3): 82-9, 2024 05 01.
Article En | MEDLINE | ID: mdl-38770885

Background: Osteogenic, antioxidant and anti-inflammatory effects of Whey protein and M. oleifera gel prompted us to evaluate their role alone or in combination on osseointegration in rabbits. Methods: In this study, 24 titanium implants were inserted in the femurs of six rabbits. One implant was placed without treatment, and another one was coated with a mixture of whey protein and M. oleifera gel for each side. The animals were divided into two groups of 2- and 6-week intervals and evaluated using histopathological and immunohistochemical techniques. Results: Histological evaluation revealed a significant difference between the experimental and the control groups after two weeks in osteoblast and osteocyte counts. The experimental group had mature bone development after six weeks of implantation, while the control group had a woven bone. Immunohistochemical results showed that the experimental group, compared to the control group, exhibited early positive expression of osteoblast cells at two weeks after the experiment. Based on histopathological observations, the experimental group showed a tiny area of collagenous fiber in 6th week after the implantation. Conclusion: A mixture of whey protein and M. oleifera could accelerate osseointegration and healing processes.


Moringa oleifera , Osseointegration , Plant Extracts , Plant Leaves , Whey Proteins , Animals , Whey Proteins/pharmacology , Rabbits , Osseointegration/drug effects , Moringa oleifera/chemistry , Plant Extracts/pharmacology , Plant Leaves/chemistry , Male , Osteoblasts/drug effects , Femur/drug effects , Osteogenesis/drug effects
6.
Bull Exp Biol Med ; 176(5): 620-625, 2024 Mar.
Article En | MEDLINE | ID: mdl-38733480

We studied the interaction of human buccal mesenchymal stem cells (MSCs) and osteoblasts differentiated from them with the surface of titanium samples. MSCs were isolated by enzymatic method from buccal fat pads. The obtained cell culture was presented by MSCs, which was confirmed by flow cytometry and differentiation into adipocytes and osteoblasts. Culturing of buccal MSCs on titanium samples was accompanied by an increase in the number of cells for 15 days and the formation of a developed network of F-actin fibers in the cells. The viability of buccal MSCs decreased by 8 days, but was restored by 15 days. Culturing of osteoblasts obtained as a result of buccal MSC differentiation on the surface of titanium samples was accompanied by a decrease in their viability and proliferation. Thus, MSCs from buccal fat pads can be used to coat implants to improve osseointegration during bone reconstruction in craniofacial surgery and dentistry. To improve the integration of osteoblasts, modification of the surface of titanium samples is required.


Cell Differentiation , Mesenchymal Stem Cells , Osseointegration , Osteoblasts , Titanium , Titanium/chemistry , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/physiology , Humans , Osseointegration/physiology , Osteoblasts/cytology , Osteoblasts/physiology , Cells, Cultured , Cell Proliferation , Dental Implants , Cell Survival , Adipocytes/cytology , Adipocytes/physiology , Mouth Mucosa/cytology , Osteogenesis/physiology
7.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Article En | MEDLINE | ID: mdl-38698477

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Talus , Humans , Talus/surgery , Talus/diagnostic imaging , Male , Adult , Female , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Retrospective Studies , Middle Aged , Young Adult , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Adolescent , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Osseointegration , Treatment Outcome , Range of Motion, Articular , Prostheses and Implants
8.
Wiad Lek ; 77(3): 462-471, 2024.
Article En | MEDLINE | ID: mdl-38691788

OBJECTIVE: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. PATIENTS AND METHODS: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF). RESULTS: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration. CONCLUSION: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.


Immediate Dental Implant Loading , Humans , Middle Aged , Adult , Male , Female , Splints , Osseointegration , Dental Implants , Dental Implantation, Endosseous/methods , Cone-Beam Computed Tomography
9.
Comput Biol Med ; 175: 108551, 2024 Jun.
Article En | MEDLINE | ID: mdl-38703546

The long-term performance of porous coated tibial implants for total ankle replacement (TAR) primarily depends on the extent of bone ingrowth at the bone-implant interface. Although attempts were made for primary fixation for immediate post-operative stability, no investigation was conducted on secondary fixation. The aim of this study is to assess bone ingrowth around the porous beaded coated tibial implant for TAR using a mechanoregulatory algorithm. A realistic macroscale finite element (FE) model of the implanted tibia was developed based on computer tomography (CT) data to assess implant-bone micromotions and coupled with microscale FE models of the implant-bone interface to predict bone ingrowth around tibial implant for TAR. The macroscale FE model was subjected to three near physiological loading conditions to evaluate the site-specific implant-bone micromotion, which were then incorporated into the corresponding microscale model to mimic the near physiological loading conditions. Results of the study demonstrated that the implant experienced tangential micromotion ranged from 0 to 71 µm with a mean of 3.871 µm. Tissue differentiation results revealed that bone ingrowth across the implant ranged from 44 to 96 %, with a mean of around 70 %. The average Young's modulus of the inter-bead tissue layer varied from 1444 to 4180 MPa around the different regions of the implant. The analysis postulates that when peak micromotion touches 30 µm around different regions of the implant, it leads to pronounced fibrous tissues on the implant surface. The highest amount of bone ingrowth was observed in the central regions, and poor bone ingrowth was seen in the anterior parts of the implant, which indicate improper osseointegration around this region. This macro-micro mechanical FE framework can be extended to improve the implant design to enhance the bone ingrowth and in future to develop porous lattice-structured implants to predict and enhance osseointegration around the implant.


Algorithms , Arthroplasty, Replacement, Ankle , Finite Element Analysis , Tibia , Humans , Tibia/surgery , Tibia/diagnostic imaging , Arthroplasty, Replacement, Ankle/instrumentation , Tomography, X-Ray Computed , Models, Biological , Osseointegration/physiology , Bone-Implant Interface/diagnostic imaging , Joint Prosthesis
10.
Ann Plast Surg ; 92(4S Suppl 2): S96-S100, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38556655

PURPOSE: Osseointegration (OI) is a novel alternative to traditional socket-suspended prostheses for lower-limb amputees, eliminating the socket-skin interface and allowing for weight bearing directly on the skeletal system. However, the stoma through which the implant attaches to the external prosthesis creates an ingress route for bacteria, and infection rates as high as 66% have been reported. The aims of this study are to classify infection management and long-term outcomes in this patient population to maximize implant salvage. METHODS: An institutional review board-approved retrospective analysis was performed on all patients who underwent lower-limb OI at our institution between 2017 and 2022. Demographic, operative, and outcome data were collected for all patients. Patients were stratified by the presence and severity of infection. Chi-square and t tests were performed on categorical and continuous data, respectively, using an alpha of 0.05. RESULTS: One hundred two patients met our study criteria; 62 had transfemoral OI and 40 had transtibial OI. Patients were followed for 23.8 months on average (range, 3.5-63.7). Osteomyelitis was more likely than soft tissue infection to be polymicrobial in nature (71% vs 23%, P < 0.05). Infections at the stoma were mostly (96%) managed with oral antibiotics alone, whereas deeper soft tissue infections also required intravenous antibiotics (75%) or operative washout (19%). Osteomyelitis was managed with intravenous antibiotics and required operative attention; 5 (71%) underwent washout and 2 (29%) underwent explantation. Both implants were replaced an average of 3.5 months after explantation. There was no correlation between history of soft tissue infection and development of osteomyelitis (P > 0.05). The overall implant salvage rate after infection was 96%. CONCLUSIONS: This study describes our institution's experience managing infection after OI and soft tissue reconstruction. Although infections do occur, they are easily treatable and rarely require operative intervention. Explantation due to infection is rare and can be followed up with reimplantation, reaffirming that OI is a safe and effective treatment modality.


Artificial Limbs , Osteomyelitis , Soft Tissue Infections , Humans , Osseointegration , Prosthesis Implantation , Retrospective Studies , Soft Tissue Infections/etiology , Artificial Limbs/adverse effects , Treatment Outcome , Anti-Bacterial Agents/therapeutic use , Osteomyelitis/etiology , Osteomyelitis/surgery
11.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article En | MEDLINE | ID: mdl-38608045

CASE: A 38-year-old man with congenital pain insensitivity underwent bilateral below-knee amputations. After his subsequent bilateral osseointegration (OI) limb replacements, he rapidly developed severe bilateral knee arthritis and varus deformity. In lieu of performing bilateral above-knee amputations, he underwent bilateral staged total knee arthroplasties (TKA) with excellent clinical and radiographic evaluation at 1-year follow-up. CONCLUSION: To address both the limited bone stock and OI implant stem location, TKA after OI limb replacement in congenital pain insensitivity patients can be successfully achieved with a nonkeeled cementless tibial component and augmentation with a tibial cone.


Arthroplasty, Replacement, Knee , Channelopathies , Pain Insensitivity, Congenital , Male , Humans , Adult , Osseointegration , Amputation, Surgical
12.
Int J Implant Dent ; 10(1): 18, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38625587

PURPOSE: Osteoporotic individuals who have dental implants usually require a prolonged healing time for osseointegration due to the shortage of bone mass and the lack of initial stability. Although studies have shown that intermittent teriparatide administration can promote osseointegration, there is little data to support the idea that pre-implantation administration is necessary and beneficial. METHODS: Sixty-four titanium implants were placed in the bilateral proximal tibial metaphysis in 32 female SD rats. Bilateral ovariectomy (OVX) was used to induce osteoporosis. Four major groups (n = 8) were created: PRE (OVX + pre-implantation teriparatide administration), POST (OVX + post-implantation administration), OP (OVX + normal saline (NS)) and SHAM (sham rats + NS). Half of rats (n = 4) in each group were euthanized respectively at 4 weeks or 8 weeks after implantation surgery, and four major groups were divided into eight subgroups (PRE4 to SHAM8). Tibiae were collected for micro-CT morphometry, biomechanical test and undecalcified sections analysis. RESULTS: Compared to OP group, rats in PRE and SHAM groups had a higher value of insertion torque (p < 0.05). The micro-CT analysis, biomechanical test, and histological data showed that peri-implant trabecular growth, implants fixation and bone-implant contact (BIC) were increased after 4 or 8 weeks of teriparatide treatment (p < 0.05). There was no statistically difference in those parameters between PRE4 and POST8 subgroups (p > 0.05). CONCLUSIONS: In osteoporotic rats, post-implantation administration of teriparatide enhanced peri-implant bone formation and this effect was stronger as the medicine was taken longer. Pre-implantation teriparatide treatment improved primary implant stability and accelerated the osseointegration process.


Dental Implants , Teriparatide , Female , Animals , Rats , Rats, Sprague-Dawley , Teriparatide/pharmacology , Teriparatide/therapeutic use , Osseointegration , Embryo Implantation , Saline Solution
13.
J Biomech Eng ; 146(10)2024 Oct 01.
Article En | MEDLINE | ID: mdl-38668718

Creating the optimal environment for effective and long term osseointegration is a heavily researched and sought-after design criteria for orthopedic implants. A validated multimaterial finite element (FE) model was developed to replicate and understand the results of an experimental in vivo push-out osseointegration model. The FE model results closely predicted global force (at 0.5 mm) and stiffness for the 50-90% porous implants with an r2 of 0.97 and 0.98, respectively. In addition, the FE global force at 0.5 mm showed a correlation to the maximum experimental forces with an r2 of 0.90. The highest porosity implants (80-90%) showed lower stiffnesses and more equitable load sharing but also failed at lower a global force level than the low porosity implants (50-70%). The lower strength of the high porosity implants caused premature plastic deformation of the implant itself during loading as well as significant deformations in the ingrown and surrounding bone, resulting in lower overall osseointegration strength, consistent with experimental measurements. The lower porosity implants showed a balance of sufficient bony ingrowth to support osseointegration strength coupled with implant mechanical properties to circumvent significant implant plasticity and collapse under the loading conditions. Together, the experimental and finite element modeling results support an optimal porosity in the range of 60-70% for maximizing osseointegration with current structure and loading.


Finite Element Analysis , Materials Testing , Osseointegration , Porosity , Prostheses and Implants , Mechanical Phenomena , Animals , Metals/chemistry , Stress, Mechanical
14.
Comput Methods Programs Biomed ; 250: 108172, 2024 Jun.
Article En | MEDLINE | ID: mdl-38669718

BACKGROUND AND OBJECTIVE: Degenerative diseases of the spine have a negative impact on the quality of life of patients. This study presents the results of numerical modelling of the mechanical behaviour of the lumbar spine with patient-specific conditions at physiological loads. This paper aims to numerically study the influence of degenerative changes in the spine and the presence of an endoprosthesis on the creation of conditions for tissue regeneration. METHODS: A numerical model of the mechanical behaviour of lumbar spine at healthy and after total disc replacement under low-energy impacts equivalent to physiological loads is presented. The model is based on the movable cellular automaton method (discrete elements), where the mechanical behaviour of bone tissue is described using the Biot poroelasticity accounting for the presence and transfer of interstitial biological fluid. The nutritional pathways of the intervertebral disc in cases of healthy and osteoporotic bone tissues were predicted based on the analysis of the simulation results according to the mechanobiological principles. RESULTS: Simulation of total disc replacement showed that osseointegration of the artificial disc plates occurs only in healthy bone tissue. With total disc replacement in a patient with osteoporosis, there is an area of increased risk of bone resorption in the near-contact area, approximately 1 mm wide, around the fixators. Dynamic loads may improve the osseointegration of the implant in pathological conditions of the bone tissue. CONCLUSIONS: The results obtained in the case of healthy spine and osteoporotic bone tissues correspond to the experimental data on biomechanics and possible methods of IVD regeneration from the position of mechanobiological principles. The results obtained with an artificial disc (with keel-type fixation) showed that the use of this type of endoprosthesis in healthy bone tissues allows to reproduce the function of the natural intervertebral disc and does not contribute to the development of neoplastic processes. In the case of an artificial disc with osteoporosis of bone tissues, there is a zone with increased risk of tissue resorption and development of neoplastic processes in the area near the contact of the implant attachment. This circumstance can be compensated by increasing the loading level.


Computer Simulation , Intervertebral Disc , Lumbar Vertebrae , Total Disc Replacement , Humans , Lumbar Vertebrae/surgery , Intervertebral Disc/surgery , Intervertebral Disc/physiopathology , Regeneration , Biomechanical Phenomena , Osteoporosis/physiopathology , Osseointegration
15.
ACS Biomater Sci Eng ; 10(5): 3255-3267, 2024 May 13.
Article En | MEDLINE | ID: mdl-38684056

Osteoporosis is a metabolic disease characterized by bone density and trabecular bone loss. Bone loss may affect dental implant osseointegration in patients with osteoporosis. To promote implant osseointegration in osteoporotic patients, we further used a nonthermal atmospheric plasma (NTAP) treatment device previously developed by our research group. After the titanium implant (Ti) is placed into the device, the working gas flow and the electrode switches are turned on, and the treatment is completed in 30 s. Previous studies showed that this NTAP device can remove carbon contamination from the implant surface, increase the hydroxyl groups, and improve its wettability to promote osseointegration in normal conditions. In this study, we demonstrated the tremendous osteogenic enhancement effect of NTAP-Ti in osteoporotic conditions in rats for the first time. Compared to Ti, the proliferative potential of osteoporotic bone marrow mesenchymal stem cells on NTAP-Ti increased by 180% at 1 day (P = 0.004), while their osteogenic differentiation increased by 149% at 14 days (P < 0.001). In addition, the results indicated that NTAP-Ti significantly improved osseointegration in osteoporotic rats in vivo. Compared to the Ti, the bone volume fraction (BV/TV) and trabecular number (Tb.N) values of NTAP-Ti in osteoporotic rats, respectively, increased by 18% (P < 0.001) and 25% (P = 0.007) at 6 weeks and the trabecular separation (Tb.Sp) value decreased by 26% (P = 0.02) at 6 weeks. In conclusion, this study proved a novel NTAP irradiation titanium implant that can significantly promote osseointegration in osteoporotic conditions.


Mesenchymal Stem Cells , Osseointegration , Osteogenesis , Osteoporosis , Plasma Gases , Rats, Sprague-Dawley , Titanium , Titanium/pharmacology , Animals , Osteogenesis/drug effects , Osteoporosis/pathology , Osteoporosis/therapy , Osteoporosis/drug therapy , Plasma Gases/pharmacology , Plasma Gases/therapeutic use , Osseointegration/drug effects , Female , Rats , Mesenchymal Stem Cells/drug effects , Cell Differentiation/drug effects , Cell Proliferation/drug effects , Prostheses and Implants
16.
Int J Biol Macromol ; 267(Pt 2): 131636, 2024 May.
Article En | MEDLINE | ID: mdl-38641287

Although bioactive peptides enhancing bone healing have demonstrated effectiveness in treating bone defects, in vivo instability poses a challenge to their clinical application. Currently reported peptide delivery systems do not meet the demands of bone tissue repair regarding stability and peptide release efficacy. Herein, the self-assembling recombinant chimeric protein (Sbp5-2RGD) is developed by genetic engineering with cell adhesion peptide RGD as the targeted peptide and a newly discovered scallop byssal-derived protein Sbp5-2 that can assemble into wet stable films as the structural domain. In vitro studies show that the Sbp5-2RGD film exhibits excellent extensibility and biocompatibility. In vitro and in vivo degradation experiments demonstrate that the film remains stable due to the layer-by-layer degradation mode, resulting in sustained delivery of RGD in situ for up to 4 weeks. Consequently, the film can effectively promote osteogenesis, which accelerates bone defect healing and the implants osseointegration. Cell-level studies further show that the film up-regulates the expression of genes and proteins (ALP, OCN, OSX, OPN, RUNX2, VEGF) associated with osteogenesis and angiogenesis. Overall, this novel protein film represents an intelligent platform for peptide immobilization, protection, and release through its self-assembly, dense structure, and degradation mode, providing a therapeutic strategy for bone repair.


Genetic Engineering , Oligopeptides , Animals , Humans , Mice , Drug Delivery Systems , Genetic Engineering/methods , Oligopeptides/chemistry , Oligopeptides/pharmacology , Osseointegration/drug effects , Osteogenesis/drug effects , Pectinidae , Rats, Sprague-Dawley , Male , Rats
17.
ACS Biomater Sci Eng ; 10(5): 3454-3469, 2024 May 13.
Article En | MEDLINE | ID: mdl-38590081

Massive unmelted Ti6Al4 V (Ti64) particles presented across all surfaces of additively manufactured Ti64 scaffolds significantly impacted the designed surface topography, mechanical properties, and permeability, reducing the osseointegration of the scaffolds. In this study, the proposed flowing acid etching (FAE) method presented high efficiency in eliminating Ti64 particles and enhancing the surface modification capacity across all surfaces of Ti64 scaffolds. The Ti64 particles across all surfaces of the scaffolds were completely removed effectively and evenly. The surface topography of the scaffolds closely resembled the design after the 75 s FAE treatment. The actual elastic modulus of the treated scaffolds (3.206 ± 0.040 GPa) was closer to the designed value (3.110 GPa), and a micrometer-scale structure was constructed on the inner and outer surfaces of the scaffolds after the 90 s FAE treatment. However, the yield strength of scaffolds was reduced to 89.743 ± 0.893 MPa from 118.251 ± 0.982 MPa after the 90 s FAE treatment. The FAE method also showed higher efficiency in decreasing the roughness and enhancing the hydrophilicity and surface energy of all of the surfaces. The FAE treatment improved the permeability of scaffolds efficiently, and the permeability of scaffolds increased to 11.93 ± 0.21 × 10-10 mm2 from 8.57 ± 0.021 × 10-10 mm2 after the 90 s FAE treatment. The treated Ti64 scaffolds after the 90 s FAE treatment exhibited optimized osseointegration effects in vitro and in vivo. In conclusion, the FAE method was an efficient way to eliminate unmelted Ti64 particles and obtain ideal surface topography, mechanical properties, and permeability to promote osseointegration in additively manufactured Ti64 scaffolds.


Alloys , Osseointegration , Surface Properties , Tissue Scaffolds , Titanium , Titanium/chemistry , Alloys/chemistry , Osseointegration/drug effects , Animals , Tissue Scaffolds/chemistry , Elastic Modulus , Materials Testing
18.
Dent Mater ; 40(5): 858-868, 2024 May.
Article En | MEDLINE | ID: mdl-38616152

OBJECTIVES: This study evaluates the potential for osseointegration and remodeling of customized dental implants made from Titanium-Hydroxyapatite Functionally Graded Material (Ti-HAP FGM) with optimized geometry, using the finite element method (FEM). METHODS: The study utilized CT scan images to model and assemble various geometrical designs of dental implants in a mandibular slice. The mechanical properties of Ti-HAP FGMs were computed by varying volume fractions (VF) of hydroxyapatite (0-20%), and a bone remodeling algorithm was used to evaluate the biomechanical characteristics of the ultimate bone configuration in the peri-implant tissue. RESULTS: The findings of the FEA reveal that osseointegration improves with changes in the density and mechanical properties of the bone surrounding Ti-HAP implants, which are influenced by the varying VF of hydroxyapatite in the FGM. SIGNIFICANCE: Increasing the hydroxyapatite fraction improves osseointegration, and appropriate length and diameter selection of Ti-HAP dental implants contribute to their stability and longevity.


Bone Remodeling , Dental Implants , Durapatite , Finite Element Analysis , Osseointegration , Titanium , Bone Remodeling/physiology , Durapatite/chemistry , Titanium/chemistry , Mandible , Tomography, X-Ray Computed , Humans , Biomechanical Phenomena , Dental Prosthesis Design , Algorithms , Materials Testing
19.
Biomater Sci ; 12(10): 2648-2659, 2024 May 14.
Article En | MEDLINE | ID: mdl-38573023

Titanium (Ti) and its alloys have been widely employed in the treatment of orthopedics and other hard tissue diseases. However, Ti-based implants are bioinert and suffer from bacterial infections and poor osseointegration in clinical applications. Herein, we successfully modified Ti with a porous N-halaminated spermidine-containing polymeric coating (Ti-SPD-Cl) through alkali-heat treatment, surface grafting and chlorination, and it has both excellent antibacterial and osteogenic abilities to significantly enhance osseointegration. The as-obtained Ti-SPD-Cl contains abundant N-Cl groups and demonstrates effective antibacterial ability against S. aureus and E. coli. Meanwhile, due to the presence of the spermidine component and construction of a porous hydrophilic surface, Ti-SPD-Cl is also beneficial for maintaining cell membrane homeostasis and promoting cell adhesion, exhibiting good biocompatibility and osteogenic ability. The rat osteomyelitis model demonstrates that Ti-SPD-Cl can effectively suppress bacterial infection and enhance bone-implant integration. Thus, Ti-SPD-Cl shows promising clinical applicability in the prevention of orthopedic implant infections and poor osseointegration.


Anti-Bacterial Agents , Coated Materials, Biocompatible , Escherichia coli , Osseointegration , Rats, Sprague-Dawley , Spermidine , Staphylococcus aureus , Titanium , Titanium/chemistry , Titanium/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Osseointegration/drug effects , Animals , Staphylococcus aureus/drug effects , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Spermidine/pharmacology , Spermidine/chemistry , Escherichia coli/drug effects , Rats , Polymers/chemistry , Polymers/pharmacology , Osteogenesis/drug effects , Mice , Surface Properties , Microbial Sensitivity Tests , Male
20.
PLoS One ; 19(4): e0300956, 2024.
Article En | MEDLINE | ID: mdl-38630711

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Hip Prosthesis/adverse effects , Periprosthetic Fractures/epidemiology , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Osseointegration , Femur/surgery , Reoperation/adverse effects , Retrospective Studies
...