Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 9.304
1.
AAPS PharmSciTech ; 25(5): 103, 2024 May 07.
Article En | MEDLINE | ID: mdl-38714634

Crystallization of amorphous pharmaceutical solids are widely reported to be affected by the addition of polymer, while the underlying mechanism require deep study. Herein, crystal growth behaviors of glassy griseofulvin (GSF) doped with various 1% w/w polymer were systematically studied. From the molecular structure, GSF cannot form the hydrogen bonding interactions with the selected polymer poly(vinyl acetate), polyvinyl pyrrolidone (PVP), 60:40 vinyl pyrrolidone-vinyl acetate copolymer (PVP/VA 64), and poly(ethylene oxide) (PEO). 1% w/w polymer exhibited weak or no detectable effects on the glass transition temperature (Tg) of GSF. However, crystal growth rates of GSF was altered from 4.27-fold increase to 2.57-fold decrease at 8 ℃ below Tg of GSF. Interestingly, the ability to accelerate and inhibit the growth rates of GSF crystals correlated well with Tg of polymer, indicating the controlling role of segmental mobility of polymer. Moreover, ring-banded growth of GSF was observed in the polymer-doped systems. Normal compact bulk and ring-banded crystals of GSF were both characterized as the thermodynamically stable form I. More importantly, formation of ring-banded crystals of GSF can significantly weaken the inhibitory effects of polymer on the crystallization of glassy GSF.


Crystallization , Griseofulvin , Polymers , Transition Temperature , Griseofulvin/chemistry , Crystallization/methods , Polymers/chemistry , Drug Stability , Hydrogen Bonding , Polyvinyls/chemistry , Polyethylene Glycols/chemistry , Povidone/chemistry , Glass/chemistry
2.
AAPS PharmSciTech ; 25(5): 113, 2024 May 15.
Article En | MEDLINE | ID: mdl-38750336

Transport of oral nanocarriers across the GI epithelium necessitates transport across hydrophilic mucus layer and the hydrophobic epithelium. Based on hydrophobic-hydrophilic balance, Curcumin-Lipomer (lipid-polymer hybrid nanoparticles) comprising hydrophobic stearic acid and hydrophilic Gantrez™ AN 119 (Gantrez) were developed, by a radical in-situ approach, to successfully traverse both barriers. A monophasic preconcentrate (Cur-Pre) comprising Cur (Curcumin), stearic acid, Gantrez and stabilizers, prepared by simple solution, was added to an aqueous phase to instantaneously generate Curcumin-Lipomer (Cur-Lipo) of nanosize and high entrapment efficiency (EE). Cur-Lipo size and EE was optimized by Box-Behnken Design. Cur-Lipomers of varying hydrophobic-hydrophilic property obtained by varying the stearic acid: Gantrez ratio exhibited size in the range 200-400 nm, EE > 95% and spherical morphology as seen in the TEM. A decrease in contact angle and in mucus interaction, evident with increase in Gantrez concentration, indicated an inverse corelation with hydrophilicity, while a linear corelation was observed for mucopenetration and hydrophilicity. Cur-SLN (solid lipid nanoparticles) which served as the hydrophobic reference revealed contact angle > 90°, maximum interaction with mucus and minimal mucopenetration. The ex-vivo permeation study through chicken ileum, revealed maximum permeation with Cur-Lipo1 and comparable and significantly lower permeation of Cur-Lipo1-D and Cur-SLN proposing the importance of balancing the hydrophobic-hydrophilic property of the nanoparticles. A 1.78-fold enhancement in flux of hydrophobic Cur-SLN, with no significant change in permeation of the hydrophilic Cur-Lipomers (p > 0.05) following stripping off the mucosal layer was observed. This reiterated the significance of hydrophobic-hydrophilic balance as a promising strategy to design nanoformulations with superior permeation across the GI barrier.


Curcumin , Drug Carriers , Hydrophobic and Hydrophilic Interactions , Intestinal Mucosa , Nanoparticles , Stearic Acids , Nanoparticles/chemistry , Administration, Oral , Animals , Stearic Acids/chemistry , Curcumin/administration & dosage , Curcumin/pharmacokinetics , Curcumin/chemistry , Intestinal Mucosa/metabolism , Drug Carriers/chemistry , Particle Size , Lipids/chemistry , Polymers/chemistry , Biological Transport/physiology , Polyvinyls/chemistry
3.
Int J Mol Sci ; 25(9)2024 May 02.
Article En | MEDLINE | ID: mdl-38732199

Nanofibrous materials generated through electrospinning have gained significant attention in tissue regeneration, particularly in the domain of bone reconstruction. There is high interest in designing a material resembling bone tissue, and many scientists are trying to create materials applicable to bone tissue engineering with piezoelectricity similar to bone. One of the prospective candidates is highly piezoelectric poly(vinylidene fluoride) (PVDF), which was used for fibrous scaffold formation by electrospinning. In this study, we focused on the effect of PVDF molecular weight (180,000 g/mol and 530,000 g/mol) and process parameters, such as the rotational speed of the collector, applied voltage, and solution flow rate on the properties of the final scaffold. Fourier Transform Infrared Spectroscopy allows for determining the effect of molecular weight and processing parameters on the content of the electroactive phases. It can be concluded that the higher molecular weight of the PVDF and higher collector rotational speed increase nanofibers' diameter, electroactive phase content, and piezoelectric coefficient. Various electrospinning parameters showed changes in electroactive phase content with the maximum at the applied voltage of 22 kV and flow rate of 0.8 mL/h. Moreover, the cytocompatibility of the scaffolds was confirmed in the culture of human adipose-derived stromal cells with known potential for osteogenic differentiation. Based on the results obtained, it can be concluded that PVDF scaffolds may be taken into account as a tool in bone tissue engineering and are worth further investigation.


Nanofibers , Polyvinyls , Tissue Engineering , Tissue Scaffolds , Tissue Engineering/methods , Polyvinyls/chemistry , Humans , Tissue Scaffolds/chemistry , Nanofibers/chemistry , Biocompatible Materials/chemistry , Cells, Cultured , Spectroscopy, Fourier Transform Infrared , Cell Differentiation/drug effects , Osteogenesis/drug effects , Stromal Cells/cytology , Stromal Cells/metabolism , Molecular Weight , Fluorocarbon Polymers
4.
Sensors (Basel) ; 24(9)2024 May 04.
Article En | MEDLINE | ID: mdl-38733034

INTRODUCTION: The choice of materials for covering plantar orthoses or wearable insoles is often based on their hardness, breathability, and moisture absorption capacity, although more due to professional preference than clear scientific criteria. An analysis of the thermal response to the use of these materials would provide information about their behavior; hence, the objective of this study was to assess the temperature of three lining materials with different characteristics. MATERIALS AND METHODS: The temperature of three materials for covering plantar orthoses was analyzed in a sample of 36 subjects (15 men and 21 women, aged 24.6 ± 8.2 years, mass 67.1 ± 13.6 kg, and height 1.7 ± 0.09 m). Temperature was measured before and after 3 h of use in clinical activities, using a polyethylene foam copolymer (PE), ethylene vinyl acetate (EVA), and PE-EVA copolymer foam insole with the use of a FLIR E60BX thermal camera. RESULTS: In the PE copolymer (material 1), temperature increases between 1.07 and 1.85 °C were found after activity, with these differences being statistically significant in all regions of interest (p < 0.001), except for the first toe (0.36 °C, p = 0.170). In the EVA foam (material 2) and the expansive foam of the PE-EVA copolymer (material 3), the temperatures were also significantly higher in all analyzed areas (p < 0.001), ranging between 1.49 and 2.73 °C for EVA and 0.58 and 2.16 °C for PE-EVA. The PE copolymer experienced lower overall overheating, and the area of the fifth metatarsal head underwent the greatest temperature increase, regardless of the material analyzed. CONCLUSIONS: PE foam lining materials, with lower density or an open-cell structure, would be preferred for controlling temperature rise in the lining/footbed interface and providing better thermal comfort for users. The area of the first toe was found to be the least overheated, while the fifth metatarsal head increased the most in temperature. This should be considered in the design of new wearables to avoid excessive temperatures due to the lining materials.


Foot Orthoses , Temperature , Humans , Female , Male , Adult , Young Adult , Polyvinyls/chemistry , Polyethylene/chemistry , Polymers/chemistry , Materials Testing
5.
Neurosurg Rev ; 47(1): 217, 2024 May 13.
Article En | MEDLINE | ID: mdl-38736006

Dural Arteriovenous Fistulas (dAVFs) of the anterior cranial fossa (ACF) are uncommon but carry a high risk of hemorrhage and pose substantial treatment challenges. Recent advancements in endovascular treatment (EVT), including the introduction of novel liquid embolic agents, have markedly bolstered EVT's role in managing ACF-dAVFs, with notable series published in the last five years. We aimed to assess the feasibility, safety, and efficacy of EVT for ACF-dAVFs. We searched Medline, Scopus, Web of Science, and Cochrane Library databases following PRISMA guidelines. Eligible studies included those with ≥ 5 patients undergoing embolization of ACF-dAVFs, detailing both angiographic and clinical outcomes. We used single proportion analysis with 95% confidence intervals under a random-effects model, I2 to assess heterogeneity, and Baujat and sensitivity analysis to address high heterogeneity. Publication bias was assessed by funnel-plot analysis and Egger's test. Outcomes included complete occlusion following embolization, unsuccessful endovascular embolization attempts, incomplete occlusion following embolization, symptom resolution or clinical improvement following embolization, recurrence; procedure-related complications, morbidity, and mortality. Additionally, a subanalysis for studies exclusively utilizing Onyx™ embolic system was done. Eighteen studies comprising 231 ACF-dAVF were included. Unsuccessful endovascular embolization attempts rate was 2%. Complete occlusion rate was 85%, with 4% of complications. Incomplete occlusion rate was 10%. Successfully embolized patients experienced either symptom resolution or clinical improvement in 94% of cases. Morbidity and mortality rates were 1% and 0%, respectively. Onyx subanalyses showed an overall rate of 0% for unsuccessful attempts, 95% for complete occlusion, and 5% for incomplete occlusion. Symptom resolution or clinical improvement was 98% and recurrence rate was 0%. EVT for ACF-dAVF is highly feasible, effective, and safe, with a low rate of complications, morbidity, and mortality. The subanalyses focusing on Onyx embolizations revealed superior efficacy and safety outcomes compared to the findings of the primary analyses involving all included studies.


Central Nervous System Vascular Malformations , Cranial Fossa, Anterior , Embolization, Therapeutic , Endovascular Procedures , Polyvinyls , Humans , Central Nervous System Vascular Malformations/therapy , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Polyvinyls/therapeutic use , Treatment Outcome , Dimethyl Sulfoxide/therapeutic use , Feasibility Studies
6.
ACS Appl Mater Interfaces ; 16(21): 27705-27713, 2024 May 29.
Article En | MEDLINE | ID: mdl-38748054

Vascular stenting is a common procedure used to treat diseased blood vessels by opening the narrowed vessel lumen and restoring blood flow to ischemic tissues in the heart and other organs. In this work, we report a novel piezoelectric stent featuring a zigzag shape fabricated by fused deposition modeling three-dimensional (3D) printing with a built-in electric field. The piezoelectric composite was made of potassium sodium niobite microparticles and poly(vinylidene fluoride-co-hexafluoropropylene), complementing each other with good piezoelectric performance and mechanical resilience. The in situ poling yielded an appreciable piezoelectricity (d33 ∼ 4.2 pC N-1) of the as-printed stents. In vitro testing revealed that materials are nontoxic to vascular cells and have low thrombotic potential. Under stimulated blood pressure fluctuation, the as-printed piezoelectric stent was able to generate peak-to-peak voltage from 0.07 to 0.15 V corresponding to pressure changes from 20 to 120 Psi, giving a sensitivity of 7.02 × 10-4 V Psi-1. Biocompatible piezoelectric stents bring potential opportunities for the real-time monitoring of blood vessels or enabling therapeutic functions.


Printing, Three-Dimensional , Stents , Humans , Electricity , Pressure , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Polyvinyls/chemistry
7.
Bioresour Technol ; 402: 130842, 2024 Jun.
Article En | MEDLINE | ID: mdl-38750828

Hydrophilic porous membranes, exemplified by polyvinylidene fluoride (PVDF) membranes, have demonstrated significant potential for replacing ion exchange membranes in microbial electrolysis cells (MECs). Membrane fouling remains a major challenge in MECs, impeding proton transport and consequently limiting hydrogen production. This study aims to investigate a synergistic antifouling strategy for PVDF membrane through the incorporation of a coating composed of polydopamine (PDA), polyethyleneimine (PEI), and silver nanoparticles (AgNPs). The PDA-PEI-Ag@PVDF membrane not only effectively mitigates fouling through steric and electrostatic repulsion forces, but also amplifies ion transport by facilitating water diffusion and electromigration. The PDA-PEI-Ag@PVDF membrane exhibited a reduced membrane resistance of 1.01 mΩ m2 and PDA-PEI-Ag modifying PVDF membrane was found to be effective in enhancing the proton transportation of PVDF membrane. Therefore, the enhanced hydrogen production rate of 2.65 ± 0.02 m3/m3/d was achieved in PDA-PEI-Ag@PVDF-MECs.


Bioelectric Energy Sources , Biofouling , Electrolysis , Hydrogen , Indoles , Membranes, Artificial , Polyvinyls , Protons , Silver , Polyvinyls/chemistry , Hydrogen/metabolism , Biofouling/prevention & control , Silver/chemistry , Silver/pharmacology , Indoles/metabolism , Indoles/chemistry , Polymers/chemistry , Metal Nanoparticles/chemistry , Polyethyleneimine/chemistry , Fluorocarbon Polymers
8.
Molecules ; 29(10)2024 May 09.
Article En | MEDLINE | ID: mdl-38792087

In this work, we present the modification of a medical-grade silicone catheter with the N-vinylimidazole monomer using the grafting-from method at room temperature and induced by gamma rays. The catheters were modified by varying the monomer concentration (20-100 vol%) and the irradiation dose (20-100 kGy). Unlike the pristine material, the grafted poly(N-vinylimidazole) chains provided the catheter with hydrophilicity and pH response. This change allowed for the functionalization of the catheters to endow it with antimicrobial features. Thus, the quaternization of amines with iodomethane and bromoethane was performed, as well as the immobilization of silver and ampicillin. The inhibitory capacity of these materials, functionalized with antimicrobial agents, was challenged against Escherichia coli and Staphylococcus aureus strains, showing variable results, where loaded ampicillin was amply better at eliminating bacteria.


Escherichia coli , Imidazoles , Silicones , Staphylococcus aureus , Escherichia coli/drug effects , Staphylococcus aureus/drug effects , Silicones/chemistry , Imidazoles/chemistry , Imidazoles/pharmacology , Catheters/microbiology , Microbial Sensitivity Tests , Polyvinyls/chemistry , Anti-Infective Agents/chemistry , Anti-Infective Agents/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Ampicillin/chemistry , Ampicillin/pharmacology , Gamma Rays
9.
Molecules ; 29(10)2024 May 16.
Article En | MEDLINE | ID: mdl-38792194

The theoretical interpretation of the vaginal permeability phenomenon, the evaluation of the suitability of five artificial membranes, and the prediction of the behaviors of vaginal drugs were the main objectives of this study. Franz vertical diffusion cells and different validated HPLC methods were used to measure the permeability of six vaginally administered drugs (econazole, miconazole, metronidazole, clindamycin, lidocaine, and nonoxynol-9). This study was performed (in vitro) on different membranes of polyvinylidene fluoride (PVDF), plain cellulose or cellulose impregnated with isopropyl myristate (IPM), and cellulose combined with PVDF or IPM. The results were compared with those obtained from cow vaginal tissue (ex vivo), where cellulose was proven to be the best simulant. According to the permeability profiles (Papp), the water solubility of the drugs was considered a necessary criterion for their transport in the membranes or in the tissue, while the size was important for their penetration. Furthermore, it was found that polar compounds show clear superiority when penetrating cellulose or tissue, while non-polar ones show superiority when penetrating the lipophilic PVDF membrane. Finally, a successful attempt was made to predict the Papp values (|Papp-predPapp| < 0.005) of the six drugs under study based on a PLS (Partial Least Squares) in silico simulation model.


Membranes, Artificial , Permeability , Vagina , Female , Vagina/metabolism , Administration, Intravaginal , Animals , Polyvinyls/chemistry , Cellulose/chemistry , Cellulose/analogs & derivatives , Cattle , Humans , Solubility , Fluorocarbon Polymers
10.
Eur J Prosthodont Restor Dent ; 32(2): 183-193, 2024 May 31.
Article En | MEDLINE | ID: mdl-38691584

INTRODUCTION: The purpose of this in vitro study was to evaluate the dimensional accuracy, trueness, and precision of vinyl siloxane ether (VSXE) and polyvinylsiloxane (PVS) impression materials using different impression techniques. MATERIAL AND METHODS: A three-dimensional (3D) printed mandibular model with implants and metal rods served as the reference model. Impressions were taken in custom trays, resulting in four groups: PVS-closed-tray, VSXE-closed-tray, PVS-open-tray, and VSXE-open-tray. The reference model and impressions were scanned and analyzed using 3D analysis software to assess the trueness and precision within each group. RESULTS: There was significant difference in trueness between the groups, with PVS closed tray showing a higher deviation than VSXE-closed-tray and PVS-open-tray. VSXE-open-tray had the lowest deviation, which was statistically significant. In terms of precision, PVS-closed-tray showed the highest deviation, while no significant differences were found among the other groups. CONCLUSIONS: VSXE impression material with an open tray technique consistently demonstrated the highest levels of accuracy and precision. Conversely, PVS impression material with a closed tray technique yielded less favorable results. CLINICAL RELEVANCE: Better understanding of trueness and precision of new impression materials with new impression techniques will increase their clinical effectiveness.


Dental Impression Materials , Dental Impression Technique , Denture, Overlay , Mandible , Polyvinyls , Siloxanes , Dental Impression Materials/chemistry , Siloxanes/chemistry , Humans , Dental Prosthesis, Implant-Supported , Printing, Three-Dimensional , In Vitro Techniques , Models, Dental
11.
ACS Appl Mater Interfaces ; 16(22): 28029-28040, 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38775012

Biophysical and biochemical cues of biomaterials can regulate cell behaviors. Dental pulp stem cells (DPSCs) in pulp tissues can differentiate to odontoblast-like cells and secrete reparative dentin to form a barrier to protect the underlying pulp tissues and enable complete pulp healing. Promotion of the odontogenic differentiation of DPSCs is essential for dentin regeneration. The effects of the surface potentials of biomaterials on the adhesion and odontogenic differentiation of DPSCs remain unclear. Here, poly(vinylidene fluoride-trifluoro ethylene) (P(VDF-TrFE)) films with different surface potentials were prepared by the spin-coating technique and the contact poling method. The cytoskeletal organization of DPSCs grown on P(VDF-TrFE) films was studied by immunofluorescence staining. Using atomic force microscopy (AFM), the lateral detachment forces of DPSCs from P(VDF-TrFE) films were quantified. The effects of electrical stimulation generated from P(VDF-TrFE) films on odontogenic differentiation of DPSCs were evaluated in vitro and in vivo. The unpolarized, positively polarized, and negatively polarized films had surface potentials of -52.9, +902.4, and -502.2 mV, respectively. DPSCs on both negatively and positively polarized P(VDF-TrFE) films had larger cell areas and length-to-width ratios than those on the unpolarized films (P < 0.05). During the detachment of DPSCs from P(VDF-TrFE) films, the average magnitudes of the maximum detachment forces were 29.4, 72.1, and 53.9 nN for unpolarized, positively polarized, and negatively polarized groups, respectively (P < 0.05). The polarized films enhanced the mineralization activities and increased the expression levels of the odontogenic-related proteins of DPSCs compared to the unpolarized films (P < 0.05). The extracellular signal-regulated kinase (ERK) signaling pathway was involved in the odontogenic differentiation of DPSCs as induced by surface charge. In vivo, the polarized P(VDF-TrFE) films enhanced adhesion of DPSCs and promoted the odontogenic differentiation of DPSCs by electrical stimulation, demonstrating a potential application of electroactive biomaterials for reparative dentin formation in direct pulp capping.


Cell Adhesion , Cell Differentiation , Dental Pulp , Electric Stimulation , Odontogenesis , Polyvinyls , Stem Cells , Dental Pulp/cytology , Cell Differentiation/drug effects , Stem Cells/cytology , Stem Cells/drug effects , Stem Cells/metabolism , Humans , Cell Adhesion/drug effects , Odontogenesis/drug effects , Polyvinyls/chemistry , Animals , Cells, Cultured , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Surface Properties
12.
Water Environ Res ; 96(5): e11018, 2024 May.
Article En | MEDLINE | ID: mdl-38712584

Applicable and low-cost ultrafiltration membranes based on waste polystyrene (WPS) blend and poly vinylidene fluoride (PVDF) were effectively cast on nonwoven support using phase inversion method. Analysis was done into how the WPS ratio affected the morphology and antifouling performance of the fabricated membranes. Cross flow filtration of pure water and various types of polluted aqueous solutions as the feed was used to assess the performance of the membranes. The morphology analysis shows that the WPS/PVDF membrane layer has completely changed from a spongy structure to a finger-like structure. In addition, the modified membrane with 50% WPS demonstrated that the trade-off between selectivity and permeability is met by a significant improvement in the rejection of the membrane with a reduction in permeate flux due to the addition of PVDF. With a water permeability of 50 LMH and 44 LMH, respectively, the optimized WPS-PVDF membrane with 50% WPS could reject 81% and 74% of Congo red dye (CR) and methylene blue dye (MB), respectively. The flux recovery ratio (FRR) reached to 88.2% by increasing PVDF concentration with 50% wt. Also, this membrane has the lowest irreversible fouling (Rir) value of 11.7% and lowest reversible fouling (Rr) value of 27.9%. The percent of cleaning efficiency reach to 71%, 90%, and 85% after eight cycles of humic acid (HA), CR, and MB filtration, respectively, for the modified PS-PVDF (50%-50%). However, higher PVDF values cause the membrane's pores to become clogged, increase the irreversible fouling, and decrease the cleaning efficiency. In addition to providing promising filtration results, the modified membrane is inexpensive because it was made from waste polystyrene, and as a result, it could be scaled up to treat colored wastewater produced by textile industries. PRACTITIONER POINTS: Recycling of plastic waste as an UF membrane for water/wastewater treatment was successfully prepared and investigated. Mechanical properties showed reasonable response with adding PVDF. The modified membrane with 50% PS demonstrated that the trade-off between selectivity and permeability is met by a significant improvement in the rejection.


Coloring Agents , Fluorocarbon Polymers , Membranes, Artificial , Ultrafiltration , Water Pollutants, Chemical , Water Purification , Ultrafiltration/methods , Coloring Agents/chemistry , Water Pollutants, Chemical/chemistry , Water Pollutants, Chemical/isolation & purification , Water Purification/methods , Plastics/chemistry , Waste Disposal, Fluid/methods , Polyvinyls/chemistry , Permeability
13.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Article En | MEDLINE | ID: mdl-38762747

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Dental Impression Materials , Glutaral , Materials Testing , Polyvinyls , Siloxanes , Dental Impression Materials/chemistry , Polyvinyls/chemistry , Siloxanes/chemistry , Time Factors , Glutaral/chemistry , Dental Disinfectants/chemistry , Sodium Hypochlorite/chemistry , Disinfectants/chemistry , Chlorhexidine/chemistry , Surface Properties , Humans
14.
Anal Chem ; 96(15): 5887-5896, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38567874

Microcystin-LR (MC-LR) is a severe threat to human and animal health; thus, monitoring it in the environment is essential, especially in water quality protections. Herein, in this work, we synthesize PVDF/CNT/Ag molecular imprinted membranes (PCA-MIMs) via an innovative combination of surface-enhanced Raman spectroscopy (SERS) detection, membrane separation, and molecular-imprinted technique toward the analysis of MC-LR in water. In particular, a light-initiated imprint is employed to protect the chemical structure of the MC-LR molecules. Furthermore, in order to ensure the detection sensitivity, the SERS substrates are combined with the membrane via the assistance of magnetism. The effect of synthesis conditions on the SERS sensitivity was investigated in detail. It is demonstrated from the characteristic results that the PCA-MIMs present high sensitivity to the MC-LR molecules with excellent selectivity against the interfere molecules. Results clearly show that the as-prepared PCA-MIMs hold great potential applications to detect trace MC-LR for the protection of water quality.


Biomimetics , Fluorocarbon Polymers , Polyvinyls , Spectrum Analysis, Raman , Humans , Spectrum Analysis, Raman/methods , Microcystins/analysis , Marine Toxins
15.
Water Sci Technol ; 89(8): 2132-2148, 2024 Apr.
Article En | MEDLINE | ID: mdl-38678414

Given the substantial environmental pollution from industrial expansion, environmental protection has become particularly important. Nowadays, anion exchange membranes (AEMs) are widely used in wastewater treatment. With the use of polyvinyl alcohol (PVA), ethylene-vinyl alcohol (EVOH) copolymer, and methyl iminodiacetic acid (MIDA), a series of cross-linked AEMs were successfully prepared using the solvent casting technique, and the network structure was formed in the membranes due to the cross-linking reaction between PVA/EVOH and MIDA. Fourier transform infrared spectrometer, X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy were used to analyze the prepared membranes. At the same time, its comprehensive properties which include water uptake, linear expansion rate, ion exchange capacity, thermal stability, chemical stability, and mechanical stability were thoroughly researched. In addition, diffusion dialysis performance in practical applications was also studied in detail. The acid dialysis coefficient (UH+) ranged from 10.2 to 35.6 × 10-3 m/h. Separation factor (S) value ranged from 25 to 38, which were all larger than that of the commercial membrane DF-120 (UH+: 8.5 × 10-3 m/h, S: 18.5). The prepared membranes had potential application value in acid recovery.


Membranes, Artificial , Polyvinyl Alcohol , Polyvinyl Alcohol/chemistry , Imino Acids/chemistry , Diffusion , Water Purification/methods , Dialysis/methods , Ion Exchange , Anions/chemistry , Polyvinyls/chemistry
16.
Eur J Pharm Sci ; 197: 106765, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38608735

Lipid-based formulations (LBFs) are an enabling-formulation approach for lipophilic poorly water-soluble compounds. In LBFs, drugs are commonly pre-dissolved in lipids, and/or surfactants/cosolvents, hereby avoiding the rate-limiting dissolution step. According to the Lipid formulation classification system, proposed by Pouton in 2006, in type II LBFs a surfactant with an HLB-value lower than 12 is added to the lipids. If high drug doses are required, e.g. for preclinical toxicity studies, supersaturated LBFs prepared at elevated temperatures may be a possibility to increase drug exposure. In the present study, the impact of digestion on drug absorption in rats was studied by pre-dosing of the lipase inhibitor orlistat. The lipid chain length of the type II LBFs was varied by administration of a medium-chain- (MC) and a long-chain (LC)-based formulation. Different drug doses, both non-supersaturated and supersaturated, were applied. Due to an inherent precipitation tendency of cinnarizine in supersaturated LBFs, the effect of the addition of the precipitation inhibitor Soluplus® was also investigated. The pharmacokinetic results were also evaluated by multiple linear regression. In most cases LC-based LBFs did not perform better in vivo, in terms of a higher area under the curve (AUC0-24 h) and maximal plasma concentration (Cmax), than MC-based LBFs. The administration of supersaturated LBFs resulted in increased AUC0-24 h (1.5 - 3.2-fold) and Cmax (1.1 - 2.6-fold)-values when compared to the non-supersaturated equivalents. Lipase inhibition led to a decreased drug exposure in most cases, especially for LC formulations (AUC0-24 h reduced to 47 - 67%, Cmax to 46 - 62%). The addition of Soluplus® showed a benefit to drug absorption from supersaturated type II LBFs (1.2 - 1.7-fold AUC0-24 h), due to an increased solubility of cinnarizine in the formulation. Upon dose-normalization of the pharmacokinetic parameters, no beneficial effect of Soluplus® could be demonstrated.


Cinnarizine , Lipids , Cinnarizine/chemistry , Cinnarizine/pharmacokinetics , Cinnarizine/administration & dosage , Animals , Male , Lipids/chemistry , Solubility , Lactones/chemistry , Lactones/pharmacokinetics , Lactones/administration & dosage , Rats, Wistar , Orlistat/administration & dosage , Orlistat/pharmacokinetics , Intestinal Absorption , Rats , Polyethylene Glycols/chemistry , Polyethylene Glycols/pharmacokinetics , Lipase/antagonists & inhibitors , Polyvinyls/chemistry , Chemical Precipitation , Surface-Active Agents/chemistry , Chemistry, Pharmaceutical/methods
17.
Environ Sci Pollut Res Int ; 31(19): 28695-28705, 2024 Apr.
Article En | MEDLINE | ID: mdl-38558343

Here, polyaniline/polyvinylidene fluoride (PANI/PVDF) nanofiber composite membrane was fabricated using electrostatic spinning technology to remove hexavalent chromium Cr(VI). The employment of PANI not only extremely enhanced the hydrophilic property of the nanofiber membrane, but also facilitated the transfer of Cr2O72- from water to the membrane. The PANI/PVDF membrane had an extremely excellent performance in getting rid of Cr(VI) and a quite large flux (250 L/m2 h). The maximum adsorption quantity of the membrane could reach 334.5 mg/g in which adsorption played 52.12% part and reduction played 47.87% part. The removal rate could reach nearly 100% immediately in the permeate solution under filtration while it needed 240 min to reach 100% only by static adsorption. Therefore, the interception of the membrane and the adsorption reduction of PANI had synergistic effect on removal of Cr(VI). Furthermore, the removal rate of Cr(VI) could still reach 95.97% after reused 8 times. The membrane showed a very good reusability and application prospect.


Chromium , Filtration , Fluorocarbon Polymers , Nanofibers , Polyvinyls , Water Pollutants, Chemical , Water Purification , Nanofibers/chemistry , Adsorption , Chromium/chemistry , Polyvinyls/chemistry , Water Pollutants, Chemical/chemistry , Water Purification/methods , Membranes, Artificial , Aniline Compounds/chemistry
18.
Langenbecks Arch Surg ; 409(1): 136, 2024 Apr 23.
Article En | MEDLINE | ID: mdl-38652308

INTRODUCTION: Prophylactic meshes in high-risk patients prevent incisional hernias, although there are still some concerns about the best layer to place them in, the type of fixation, the mesh material, the significance of the level of contamination, and surgical complications. We aimed to provide answers to these questions and information about how the implanted material behaves based on its visibility under magnetic resonance imaging (MRI). METHOD: This is a prospective multicentre observational cohort study. Preliminary results from the first 3 months are presented. We included general surgical patients who had at least two risk factors for developing an incisional hernia. Multivariate logistic regression was used. A polyvinylidene fluoride (PVDF) mesh loaded with iron particles was used in an onlay position. MRIs were performed 6 weeks after treatment. RESULTS: Between July 2016 and June 2022, 185 patients were enrolled in the study. Surgery was emergent in 30.3% of cases, contaminated in 10.7% and dirty in 11.8%. A total of 5.6% of cases had postoperative wound infections, with the requirement of stoma being the only significant risk factor (OR = 7.59, p = 0.03). The formation of a seroma at 6 weeks detected by MRI, was associated with body mass index (OR = 1.13, p = 0.02). CONCLUSIONS: The prophylactic use of onlay PVDF mesh in midline laparotomies in high-risk patients was safe and effective in the short term, regardless of the type of surgery or the level of contamination. MRI allowed us to detect asymptomatic seromas during the early process of integration. STUDY REGISTRATION:  This protocol was registered at ClinicalTrials.gov (NCT03105895).


Fluorocarbon Polymers , Incisional Hernia , Magnetic Resonance Imaging , Polyvinyls , Surgical Mesh , Adult , Aged , Female , Humans , Male , Middle Aged , Incisional Hernia/prevention & control , Prospective Studies , Risk Factors , Time Factors , Treatment Outcome , Young Adult , Aged, 80 and over
19.
Clin Neurol Neurosurg ; 241: 108290, 2024 06.
Article En | MEDLINE | ID: mdl-38663200

Thunderclap headache is a sudden severe headache with onset to peak within one minute. Multiple excruciating, short-lived thunderclap headaches over a few days to weeks are highly suggestive of reversible cerebral vasoconstriction syndrome (RCVS). RCVS can be primary or secondary to several factors, but it is rarely described after neuro-endovascular procedures using onyx material. A 10-year-old child presented with RCVS heralded by recurrent thunderclap headache following endovascular embolization of pial arteriovenous malformation with onyx material (contains organic solvent dimethyl sulfoxide). Dimethyl sulfoxide is an angiotoxic material that can cause dysregulation of cerebral vascular tone triggering reversible cerebral vasoconstriction syndrome. Recurrent thunderclap headache after embolization procedures using onyx material should prompt for the diagnosis of reversible cerebral vasoconstriction syndrome.


Dimethyl Sulfoxide , Embolization, Therapeutic , Headache Disorders, Primary , Intracranial Arteriovenous Malformations , Polyvinyls , Humans , Embolization, Therapeutic/methods , Child , Headache Disorders, Primary/etiology , Headache Disorders, Primary/therapy , Dimethyl Sulfoxide/adverse effects , Intracranial Arteriovenous Malformations/therapy , Intracranial Arteriovenous Malformations/diagnostic imaging , Intracranial Arteriovenous Malformations/complications , Male , Vasospasm, Intracranial/diagnostic imaging , Vasospasm, Intracranial/etiology , Vasospasm, Intracranial/therapy , Female , Recurrence
20.
ACS Biomater Sci Eng ; 10(5): 2805-2826, 2024 May 13.
Article En | MEDLINE | ID: mdl-38621173

Tissue engineering involves implanting grafts into damaged tissue sites to guide and stimulate the formation of new tissue, which is an important strategy in the field of tissue defect treatment. Scaffolds prepared in vitro meet this requirement and are able to provide a biochemical microenvironment for cell growth, adhesion, and tissue formation. Scaffolds made of piezoelectric materials can apply electrical stimulation to the tissue without an external power source, speeding up the tissue repair process. Among piezoelectric polymers, poly(vinylidene fluoride) (PVDF) and its copolymers have the largest piezoelectric coefficients and are widely used in biomedical fields, including implanted sensors, drug delivery, and tissue repair. This paper provides a comprehensive overview of PVDF and its copolymers and fillers for manufacturing scaffolds as well as the roles in improving piezoelectric output, bioactivity, and mechanical properties. Then, common fabrication methods are outlined such as 3D printing, electrospinning, solvent casting, and phase separation. In addition, the applications and mechanisms of scaffold-based PVDF in tissue engineering are introduced, such as bone, nerve, muscle, skin, and blood vessel. Finally, challenges, perspectives, and strategies of scaffold-based PVDF and its copolymers in the future are discussed.


Polyvinyls , Tissue Engineering , Tissue Scaffolds , Polyvinyls/chemistry , Tissue Scaffolds/chemistry , Tissue Engineering/methods , Humans , Printing, Three-Dimensional , Biocompatible Materials/chemistry , Polymers/chemistry , Animals , Fluorocarbon Polymers
...