Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 180
1.
Nucl Med Rev Cent East Eur ; 26(0): 123-129, 2023.
Article En | MEDLINE | ID: mdl-37786949

BACKGROUND: As a result of constantly improving surgical methods, an increasing number of patients have medical devices implanted in the cardiovascular system (including vascular grafts and endografts). Such patients are characterised by their high risk of infectious complications due to the possibility of biofilm formation on implanted material. This work aims to analyse the utility of 2-[18F]FDG PET/CT in diagnosing vascular graft and endograft infections. MATERIAL AND METHODS: The study was undertaken on a group of 58 patients, of whom 34 were in the study group, and 24 were in the control group. The 2-[18F]FDG PET/CT study was conducted in the Nuclear Medicine Department at the University Hospital of Lublin. The inclusion criteria for the study group were the presence of a vascular graft or endograft that encompasses the aorta, and strong clinical suspicion of its infection. The inclusion criteria for the control group were the presence of a vascular graft or endograft in the large arteries and the absence of signs of its infection on 2-[18F]FDG PET/CT, as well as the absence of clinically apparent signs and symptoms during six months of observation after 2-[18F]FDG PET/CT. All patients found in the database that met the criteria were included. RESULTS: Vascular endografts were more common in the control group than in the study group. However, in the case of infection of the vascular endograft, signs of infection in 2-[18F]FDG PET/CT were more severe. Images in the study group were divided into three groups that represent image patterns based on CT and PET characteristics. The first pattern (P1) was recognised in six patients. The second (P2) and third (P3) were visible in 11 and 17 patients, respectively. CONCLUSIONS: Comparative analysis of the study and control groups demonstrates the utility of 2-[18F]FDG PET/CT in the diagnosis of vascular graft/endograft infection.


Positron Emission Tomography Computed Tomography , Prosthesis-Related Infections , Humans , Positron Emission Tomography Computed Tomography/methods , Fluorodeoxyglucose F18 , Radiopharmaceuticals , Prosthesis-Related Infections/diagnostic imaging , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods
2.
Bone Marrow Transplant ; 58(9): 973-979, 2023 09.
Article En | MEDLINE | ID: mdl-37537245

Acute gastrointestinal graft versus host disease (GI-GVHD) is a common complication following allogeneic haematopoietic cell transplantation (HCT), and is characterised by severe morbidity, frequent treatment-refractoriness, and high mortality. Early, accurate identification of GI-GVHD could allow for therapeutic interventions to ameliorate its severity, improve response rates and survival; however, standard endoscopic biopsy is inadequately informative in terms of diagnostic sensitivity or outcome prediction. In an era where rapid technological and laboratory advances have dramatically expanded our understanding of GI-GVHD biology and potential therapeutic targets, there is substantial scope for novel investigations that can precisely guide GI-GVHD management. In particular, the combination of tissue-based biomarker assessment (plasma cytokines, faecal microbiome) and molecular imaging by positron emission tomography (PET) offers the potential for non-invasive, real-time in vivo assessment of donor:recipient immune activity within the GI tract for GI-GVHD prediction or diagnosis. In this article, we review the evidence regarding GI-GVHD diagnosis, and examine the potential roles and translational opportunities posed by these novel diagnostic tools, with a focus on the evolving role of PET.


Gastrointestinal Diseases , Graft vs Host Disease , Hematopoietic Stem Cell Transplantation , Humans , Graft vs Host Disease/diagnostic imaging , Graft vs Host Disease/etiology , Hematopoietic Stem Cell Transplantation/adverse effects , Gastrointestinal Tract/diagnostic imaging , Positron-Emission Tomography/adverse effects , Biopsy/adverse effects , Acute Disease , Gastrointestinal Diseases/diagnostic imaging , Gastrointestinal Diseases/etiology
3.
Pediatr Transplant ; 27(5): e14501, 2023 08.
Article En | MEDLINE | ID: mdl-36906739

BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is a serious complication after pediatric liver transplantation (pLT), which may lead to death. 18 F-FDG PET/CT is rarely considered in PTLD after pLT and lacks clear diagnostic guidelines, especially in the differential diagnosis of nondestructive PTLD. The aim of this study was to find a quantifiable 18 F-FDG PET/CT index to identify nondestructive PTLD after pLT. METHODS: This retrospective study collected the data of patients who underwent pLT, postoperative lymph node biopsy, and 18 F-FDG PET/CT at Tianjin First Central Hospital from January 2014 to December 2021. Quantitative indexes were established using lymph node morphology and the maximum standardized uptake value (SUVmax). RESULTS: A total of 83 patients met the inclusion criteria and were included in this retrospective study. To distinguish between PTLD-negative cases and nondestructive PTLD cases, according to the receiver operating characteristic curve, (the shortest diameter of the lymph node at the biopsy site [SDL]/the longest diameter of the lymph node at the biopsy site [LDL])*(SUVmax at the biopsy site [SUVmaxBio]/SUVmax of the tonsils [SUVmaxTon]) had the maximum area under the curve (0.923; 95% confidence interval: 0.834-1.000), and the cutoff value was 0.264 according to the maximum value of Youden's index. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 93.6%, 94.7%, 97.8%, 85.7%, and 93.9%, respectively. CONCLUSIONS: (SDL/LDL)*(SUVmaxBio/SUVmaxTon) has good sensitivity, specificity, positive predictive and negative predictive values, and accuracy, and can be used as a good quantitative index for the diagnosis of nondestructive PTLD.


Epstein-Barr Virus Infections , Liver Transplantation , Lymphoproliferative Disorders , Humans , Child , Positron Emission Tomography Computed Tomography/adverse effects , Fluorodeoxyglucose F18 , Liver Transplantation/adverse effects , Retrospective Studies , Positron-Emission Tomography/adverse effects , Lymphoproliferative Disorders/diagnostic imaging , Lymphoproliferative Disorders/etiology , Epstein-Barr Virus Infections/complications , Radiopharmaceuticals
4.
Transpl Infect Dis ; 25(2): e14015, 2023 Apr.
Article En | MEDLINE | ID: mdl-36734631

BACKGROUND: Despite superiority of preemptive therapy (PET) compared to universal prophylaxis for prevention of cytomegalovirus (CMV) disease in the CAPSIL randomized trial among CMV D+R- liver transplant recipients (LTxRs), real-world effectiveness may be lower because of logistical concerns about feasibility of PET. METHODS: We retrospectively assessed PET as standard clinical care at a single transplant center among 50 consecutive adult CMV D+R- LTxRs undergoing a first liver transplant between 4/4/2019 and 5/18/2021 and compared outcomes and adherence to those randomized to PET in the CAPSIL study (N = 100). The primary outcome was CMV disease and secondary outcomes were biopsy-confirmed acute allograft rejection, retransplant, invasive fungal infections, and death, all assessed by 1-year post-transplant. Exploratory outcomes included virologic parameters and measures of adherence to protocol-specified CMV qPCR monitoring. RESULTS: Baseline characteristics were similar between groups. The cumulative incidence of CMV disease at 1-year post-transplant was 4/50 (8%) versus 9/100 (9%) in the real-world and CAPSIL cohorts, respectively, p = 1.0. The rate of breakthrough CMV disease during the 100-day PET period was low (2/50 [4%]) and similar to the PET cohort from the CAPSIL study (3/100 [3%]).  All secondary and exploratory outcomes were not significantly different between the real-world and CAPSIL PET cohorts. CONCLUSIONS: In this first reported study of real-world PET, the feasibility and effectiveness for CMV disease prevention and for other clinical outcomes in CMV D+R- LTxRs were similar to those reported with PET in a clinical trial. Additional studies to confirm feasibility and generalizability in other settings are warranted.


Cytomegalovirus Infections , Liver Transplantation , Adult , Humans , Cytomegalovirus , Antiviral Agents/therapeutic use , Liver Transplantation/adverse effects , Retrospective Studies , Treatment Outcome , Cytomegalovirus Infections/epidemiology , Cytomegalovirus Infections/prevention & control , Cytomegalovirus Infections/drug therapy , Positron-Emission Tomography/adverse effects , Transplant Recipients , Ganciclovir/therapeutic use
5.
Perit Dial Int ; 43(3): 263-267, 2023 05.
Article En | MEDLINE | ID: mdl-36601674

Pet ownership is common around the world, with pet ownership increasing in many countries. Current guidelines are not supportive of pet ownership for peritoneal dialysis (PD) patients. We examined the association between ownership of cats and dogs and the incidence of peritonitis among PD patients participating in the prospective, observational Peritoneal Dialysis Outcomes and Practice Patterns Study. A total of 3655 PD patients from eight different countries was included, with a median follow-up of 14 months and a total exposure time of 55,475 patient-months. There were 1347 peritonitis episodes with an overall peritonitis rate of 0.29 episodes per patient year. There was no significant increased risk of peritonitis with any type of pet ownership, adjusted hazard ratio (HR) of 1.09 (95% confidence interval (95% CI): 0.96-1.25). However, patients who owned both cats and dogs had an increased risk of peritonitis compared to patients without pets, HR = 1.45 (95% CI: 1.14-1.86). These results suggest that there is no increased risk of peritonitis with pet ownership except for those with both cats and dogs. This information should not prevent PD patients from owning pets but may be helpful for PD patients and their care team to direct training to minimise the risk of peritonitis.


Peritoneal Dialysis , Peritonitis , Cats , Animals , Dogs , Peritoneal Dialysis/adverse effects , Prospective Studies , Ownership , Peritonitis/epidemiology , Peritonitis/etiology , Positron-Emission Tomography/adverse effects
6.
Eur Heart J ; 44(45): 4748-4751, 2023 Dec 01.
Article En | MEDLINE | ID: mdl-36477859

Current cardiology guidelines assign a class of recommendation 1 for the diagnosis of chest pain to five imaging techniques based on either anatomic (coronary computed tomography angiography) or functional approaches, such as stress single-photon emission tomography, stress positron emission tomography, stress cardiovascular magnetic resonance, and stress echocardiography. The choice is left to the prescribing physician, based on local availability and expertise. However, the five techniques differ substantially in their cost, applicability based on patient characteristics, long-term risk, and environmental impact. The average European immediate cost ranges from 50 to 1000 euros. The radiation exposure ranges from 0 to 500 chest x-rays. The environmental footprint ranges from 3 to 300 kg of carbon dioxide emissions equivalent. The ethical code of the World Medical Association 2021 recommends the responsible use of healthcare money by doctors, with the minimization of potential damage to patients and the environment. The Euratom law 2013/directive 59 reinforces the justification principle and the optimization principle for medical radiation exposures, with the legal responsibility of both the referrer and the practitioner. A small cost, a minimal long-term risk, and a modest carbon emission per examination multiplied by billions of tests per year become an unaffordable economic burden in the short-term, significant population damage to public health over the years, and impacts on climate change in decades. The cardiology community may wish to adopt a more sustainable practice with affordable, radiation-optimized, and carbon-neutral practices for the benefit of patients, physicians, payers, and the planet.


Cardiac Imaging Techniques , Tomography, Emission-Computed, Single-Photon , Humans , Positron-Emission Tomography/adverse effects , Tomography, X-Ray Computed , Magnetic Resonance Imaging/adverse effects
7.
J Nucl Med ; 64(2): 312-319, 2023 02.
Article En | MEDLINE | ID: mdl-36215573

When pregnancy is discovered during or after a diagnostic examination, the physician or the patient may request an estimate of the radiation dose received by the fetus as per guidelines and standard operating procedures. This study provided the imaging community with dose estimates to the fetus from PET/CT with protocols that are adapted to University of Michigan low-dose protocols for patients known to be pregnant. Methods: There were 9 patients analyzed with data for the first, second, and third trimesters, the availability of which is quite rare. These images were used to calculate the size-specific dose estimate (SSDE) from the CT scan portion and the SUV and 18F-FDG uptake dose from the PET scan portion using the MIRD formulation. The fetal dose estimates were tested for correlation with each of the following independent measures: gestational age, fetal volume, average water-equivalent diameter of the patient along the length of the fetus, SSDE, SUV, and percentage of dose from 18F-FDG. Stepwise multiple linear regression analysis was performed to assess the partial correlation of each variable. To our knowledge, this was the first study to determine fetal doses from CT and PET images. Results: Fetal self-doses from 18F for the first, second, and third trimesters were 2.18 mGy (single data point), 0.74-1.82 mGy, and 0.017-0.0017 mGy, respectively. The combined SSDE and fetal self-dose ranged from 1.2 to 8.2 mGy. These types of images from pregnant patients are rare. Conclusion: Our data indicate that the fetal radiation exposure from 18F-FDG PET and CT performed, when medically necessary, on pregnant women with cancer is low. All efforts should be made to minimize fetal radiation exposure by modifying the protocol.


Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Humans , Female , Pregnancy , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Fetus/diagnostic imaging , Tomography, X-Ray Computed/methods , Radiation Dosage
8.
J Nucl Med ; 64(2): 320-328, 2023 02.
Article En | MEDLINE | ID: mdl-36008121

There remains an unmet need for molecularly targeted imaging agents for multiple myeloma (MM). The integrin very late antigen 4 (VLA4), is differentially expressed in malignant MM cells and in pathogenic inflammatory microenvironmental cells. [64Cu]Cu-CB-TE1A1P-LLP2A (64Cu-LLP2A) is a VLA4-targeted, high-affinity radiopharmaceutical with promising utility for managing patients diagnosed with MM. Here, we evaluated the safety and human radiation dosimetry of 64Cu-LLP2A for potential use in MM patients. Methods: A single-dose [natCu]Cu-LLP2A (Cu-LLP2A) tolerability and toxicity study was performed on CD-1 (Hsd:ICR) male and female mice. 64Cu-LLP2A was synthesized in accordance with good-manufacturing-practice-compliant procedures. Three MM patients and six healthy participants underwent 64Cu-LLP2A-PET/CT or PET/MRI at up to 3 time points to help determine tracer biodistribution, pharmacokinetics, and radiation dosimetry. Time-activity curves were plotted for each participant. Mean organ-absorbed doses and effective doses were calculated using the OLINDA software. Tracer bioactivity was evaluated via cell-binding assays, and metabolites from human blood samples were analyzed with analytic radio-high-performance liquid chromatography. When feasible, VLA4 expression was evaluated in the biopsy tissues using 14-color flow cytometry. Results: A 150-fold mass excess of the desired imaging dose was tolerated well in male and female CD-1 mice (no observed adverse effect level). Time-activity curves from human imaging data showed rapid tracer clearance from blood via the kidneys and bladder. The effective dose of 64Cu-LLP2A in humans was 0.036 ± 0.006 mSv/MBq, and the spleen had the highest organ uptake, 0.142 ± 0.034 mSv/MBq. Among all tissues, the red marrow demonstrated the highest residence time. Image quality analysis supports an early imaging time (4-5 h after injection of the radiotracer) as optimal. Cell studies showed statistically significant blocking for the tracer produced for all human studies (82.42% ± 13.47%). Blood metabolism studies confirmed a stable product peak (>90%) up to 1 h after injection of the radiopharmaceutical. No clinical or laboratory adverse events related to 64Cu-LLP2A were observed in the human participants. Conclusion: 64Cu-LLP2A exhibited a favorable dosimetry and safety profile for use in humans.


Multiple Myeloma , Positron Emission Tomography Computed Tomography , Humans , Male , Female , Animals , Mice , Radiopharmaceuticals/pharmacokinetics , Tissue Distribution , Mice, Inbred ICR , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Radiometry , Multiple Myeloma/metabolism
9.
Eur J Nucl Med Mol Imaging ; 50(2): 344-351, 2023 01.
Article En | MEDLINE | ID: mdl-36197499

PURPOSE: [18F]3F4AP is a novel PET radiotracer that targets voltage-gated potassium (K+) channels and has shown promise for imaging demyelinated lesions in animal models of neurological diseases. This study aimed to evaluate the biodistribution, safety, and radiation dosimetry of [18F]3F4AP in healthy human volunteers. METHODS: Four healthy volunteers (2 females) underwent a 4-h dynamic PET scan from the cranial vertex to mid-thigh using multiple bed positions after administration of 368 ± 17.9 MBq (9.94 ± 0.48 mCi) of [18F]3F4AP. Volumes of interest for relevant organs were manually drawn guided by the CT, and PET images and time-activity curves (TACs) were extracted. Radiation dosimetry was estimated from the integrated TACs using OLINDA software. Safety assessments included measuring vital signs immediately before and after the scan, monitoring for adverse events, and obtaining a comprehensive metabolic panel and electrocardiogram within 30 days before and after the scan. RESULTS: [18F]3F4AP distributed throughout the body with the highest levels of activity in the kidneys, urinary bladder, stomach, liver, spleen, and brain and with low accumulation in muscle and fat. The tracer cleared quickly from circulation and from most organs. The clearance of the tracer was noticeably faster than previously reported in nonhuman primates (NHPs). The average effective dose (ED) across all subjects was 12.1 ± 2.2 µSv/MBq, which is lower than the estimated ED from the NHP studies (21.6 ± 0.6 µSv/MBq) as well as the ED of other fluorine-18 radiotracers such as [18F]FDG (~ 20 µSv/MBq). No differences in ED between males and females were observed. No substantial changes in safety assessments or adverse events were recorded. CONCLUSION: The biodistribution and radiation dosimetry of [18F]3F4AP in humans are reported for the first time. The average total ED across four subjects was lower than most 18F-labeled PET tracers. The tracer and study procedures were well tolerated, and no adverse events occurred.


Demyelinating Diseases , Radiometry , Male , Female , Animals , Humans , Tissue Distribution , Radiometry/methods , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Radiopharmaceuticals
10.
Folia Med (Plovdiv) ; 65(5): 849-854, 2023 Oct 31.
Article En | MEDLINE | ID: mdl-38351771

Infective endocarditis (IE) is a difficult-to-diagnose provocative disease that causes significant morbidity and mortality. The first-line imaging test for the diagnosis of IE is echocardiography. However, in cases of prosthetic IE or IE associated with intracardiac devices, its sensitivity is limited. A new diagnostic tool, 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET/CT), improves diagnosis in these difficult cases. The most recent European guidelines for IE (2015) include this imaging modality as a primary diagnostic criterion. We present a case of culture-negative prosthetic IE diagnosed with 18F-FDG PET/CT.


Endocarditis, Bacterial , Endocarditis , Fluorine Radioisotopes , Heart Valve Prosthesis , Prosthesis-Related Infections , Humans , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography/adverse effects , Positron Emission Tomography Computed Tomography/methods , Radiopharmaceuticals , Heart Valve Prosthesis/adverse effects , Endocarditis, Bacterial/diagnostic imaging , Endocarditis/diagnostic imaging , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/complications
11.
Eur J Nucl Med Mol Imaging ; 49(12): 4037-4047, 2022 Oct.
Article En | MEDLINE | ID: mdl-35779082

PURPOSE: This study assesses human biodistribution, radiation dosimetry, safety and tumour uptake of cell death indicator labelled with 68Ga ([68Ga]Ga-CDI), a novel radiopharmaceutical that can image multiple forms of cell death. METHODS: Five participants with at least one extracranial site of solid malignancy > 2 cm and no active cancer treatment in the 8 weeks prior to the study were enrolled. Participants were administered 205 ± 4.1 MBq (range, 200-211 MBq) of [68Ga]Ga-CDI and 8 serial PET scans acquired: the first commencing immediately and the last 3 h later. Participants were monitored for clinical, laboratory and electrocardiographic side effects and adverse events. Urine and blood radioactivity was measured. Spherical volumes of interest were drawn over tumour, blood pool and organs to determine biodistribution and calculate dosimetry. In one participant, tumour specimens were analysed for cell death using terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL) staining. RESULTS: [68Ga]Ga-CDI is safe and well-tolerated with no side effects or adverse events. [68Ga]Ga-CDI is renally excreted, demonstrates low levels of physiologic uptake in the other organs and has excellent imaging characteristics. The mean effective dose was 2.17E - 02 ± 4.61E - 03 mSv/MBq. It images constitutive tumour cell death and correlates with tumour cell death on histology. CONCLUSION: [68Ga]Ga-CDI is a novel cell death imaging radiopharmaceutical that is safe, has low radiation dosimetry and excellent biodistribution and imaging characteristics. It has potential advantages over previously investigated radiopharmaceuticals for imaging of cell death and has progressed to a proof-of-concept trial. TRIAL REGISTRATION: ACTRN12621000641897 (28/5/2021, retrospectively registered).


Neoplasms , Radiopharmaceuticals , Cell Death , DNA Nucleotidylexotransferase/metabolism , Electrons , Gallium Radioisotopes , Humans , Neoplasms/diagnostic imaging , Neoplasms/metabolism , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Radiometry , Radiopharmaceuticals/adverse effects , Tissue Distribution
12.
IEEE Trans Med Imaging ; 41(8): 2092-2104, 2022 08.
Article En | MEDLINE | ID: mdl-35239478

Potential radioactive hazards in full-dose positron emission tomography (PET) imaging remain a concern, whereas the quality of low-dose images is never desirable for clinical use. So it is of great interest to translate low-dose PET images into full-dose. Previous studies based on deep learning methods usually directly extract hierarchical features for reconstruction. We notice that the importance of each feature is different and they should be weighted dissimilarly so that tiny information can be captured by the neural network. Furthermore, the synthesis on some regions of interest is important in some applications. Here we propose a novel segmentation guided style-based generative adversarial network (SGSGAN) for PET synthesis. (1) We put forward a style-based generator employing style modulation, which specifically controls the hierarchical features in the translation process, to generate images with more realistic textures. (2) We adopt a task-driven strategy that couples a segmentation task with a generative adversarial network (GAN) framework to improve the translation performance. Extensive experiments show the superiority of our overall framework in PET synthesis, especially on those regions of interest.


Deep Learning , Image Processing, Computer-Assisted , Neural Networks, Computer , Positron-Emission Tomography , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Radiation Dosage , Radiation Injuries/etiology , Radiation Injuries/prevention & control
13.
Semin Respir Crit Care Med ; 43(1): 150-172, 2022 02.
Article En | MEDLINE | ID: mdl-35172365

Infective endocarditis is a relatively rare, but deadly infection, with an overall mortality of around 20% in most series. Clinical manifestations have evolved in response to significant epidemiological shifts in industrialized nations, with a move toward a nosocomial or health-care-related pattern, in older patients, with more episodes associated with prostheses and/or intravascular electronic devices and a predominance of staphylococcal and enterococcal etiology.Diagnosis is often challenging and is based on the conjunction of clinical, microbiological, and imaging information, with notable progress in recent years in the accuracy of echocardiographic data, coupled with the recent emergence of other useful imaging techniques such as cardiac computed tomography (CT) and nuclear medicine tools, particularly 18F-fluorodeoxyglucose positron emission/CT.The choice of an appropriate treatment for each specific case is complex, both in terms of the selection of the appropriate agent and doses and durations of therapy as well as the possibility of using combined bactericidal antibiotic regimens in the initial phase and finalizing treatment at home in patients with good evolution with outpatient oral or parenteral antimicrobial therapies programs. A relevant proportion of patients will also require valve surgery during the active phase of treatment, the timing of which is extremely difficult to define. For all the above, the management of infective endocarditis requires a close collaboration of multidisciplinary endocarditis teams.


Endocarditis, Bacterial , Endocarditis , Aged , Endocarditis/diagnosis , Endocarditis/drug therapy , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/drug therapy , Fluorodeoxyglucose F18 , Humans , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Radiopharmaceuticals
14.
J Intern Med ; 291(6): 856-863, 2022 06.
Article En | MEDLINE | ID: mdl-35018669

BACKGROUND: Inflammation of unknown origin (IUO) is a challenging situation in internal medicine. OBJECTIVES: To describe the final diagnoses in IUO and assess the helpfulness of 18 F-fluorodesoxyglucose positron emission tomography with computerized tomography (18 F-FDG-PET/CT) in the diagnosis strategy. RESULTS: A total of 317 IUO patients with 18 F-FDG-PET/CT were enrolled. A diagnosis was reached in 228 patients: noninfectious inflammatory diseases (NIID) (37.5%), infectious diseases (18.6%), malignancies (7.9%), and non-systemic-inflammatory miscellaneous diseases (7.9%). The two leading causes of NIID were polymyalgia rheumatica and giant cell arteritis. 18 F-FDG-PET/CT results were classified as true positive in 49.8% of patients and contributory in 75.1% of overall IUO patients (after the complete investigation set and a prolonged follow-up). In multivariate analysis, only C-reactive protein minimum level (≥50 mg/L) was associated with the contributory status of 18 F-FDG-PET/CT. CONCLUSION: Within the wide spectrum of IUO underlying diseases, 18 F-FDG-PET/CT is helpful to make a diagnosis and to eliminate inflammatory diseases. Obese patients constitute a specific group needing further studies.


Fever of Unknown Origin , Noncommunicable Diseases , Fever of Unknown Origin/diagnostic imaging , Fever of Unknown Origin/etiology , Fluorodeoxyglucose F18 , Humans , Inflammation/complications , Inflammation/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography/adverse effects
15.
Clin Res Cardiol ; 111(6): 673-679, 2022 Jun.
Article En | MEDLINE | ID: mdl-34821999

INTRODUCTION: 18F-fluorodeoxyglucose positron emission tomography (18F-FDG-PET/CT) is not routinely recommended for the diagnosis of infective endocarditis (IE) due to the lack of clinical impact. MATERIALS AND METHODS: Between January 2016 and January 2020, clinical data from patients with a possible diagnosis of IE were reviewed retrospectively to evaluate the value of 18F-FDG-PET/CT in the diagnosis of IE. 18F-FDG PET/CT scan was performed as an additional diagnostic tool in possible IE when echocardiography was inconclusive or in patients with definite IE to identify extracardiac complications. Cases were classified according to modified Duke criteria as rejected, definite or possible. RESULTS: 313 patients with suspected IE were included. 72 (23%) patients underwent 18F-FDG PET/CT. 18F-FDG PET/CT resulted in a reclassification of Duke criteria in 29/72 (40%) patients, from "possible" to "definite" (n, 10) and to "rejected" (n, 19). Patients who benefited from a Duke criteria reclassification following 18F-FDG PET/CT were more frequently classified as possible IE at inclusion or had a non-conclusive baseline echocardiography (100% vs 58%; p 0.001) and had more likely a prosthetic metallic valve replacement (59% vs 21%; p 0.001). Abnormal perivalvular uptake was identified in 46 patients (71% prosthetic vs 50% native; p 0.118). 18F-FDG PET/CT identified extracardiac uptake consistent with septic emboli in 14/72 (19%) patients. In addition, extracardiac uptake indicative of an alternative diagnosis was identified in 5 patients (2% prosthetic vs 17% native; p 0.039). CONCLUSION: The use of 18F-FDG-PET/CT has shown to be useful in the diagnosis of IE, particularly in prosthetic IE and may provide additional value in the detection of septic emboli and/or the identification of an alternative diagnosis different from IE.


Endocarditis, Bacterial , Endocarditis , Endocarditis/diagnostic imaging , Endocarditis/etiology , Fluorodeoxyglucose F18 , Humans , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography/adverse effects , Radiopharmaceuticals/pharmacology , Retrospective Studies
16.
J Cereb Blood Flow Metab ; 41(11): 2805-2819, 2021 11.
Article En | MEDLINE | ID: mdl-34018825

Clinical positron emission tomography (PET) research is costly and entails exposing participants to radioactivity. Researchers should therefore aim to include just the number of subjects needed to fulfill the purpose of the study. In this tutorial we show how to apply sequential Bayes Factor testing in order to stop the recruitment of subjects in a clinical PET study as soon as enough data have been collected to make a conclusion. By using simulations, we demonstrate that it is possible to stop a study early, while keeping the number of erroneous conclusions low. We then apply sequential Bayes Factor testing to a real PET data set and show that it is possible to obtain support in favor of an effect while simultaneously reducing the sample size with 30%. Using this procedure allows researchers to reduce expense and radioactivity exposure for a range of effect sizes relevant for PET research.


Computer Simulation/statistics & numerical data , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/economics , Radiation Exposure/prevention & control , Adult , Bayes Theorem , Case-Control Studies , Early Termination of Clinical Trials/ethics , Early Termination of Clinical Trials/methods , Female , Humans , Male , Middle Aged , Positron-Emission Tomography/statistics & numerical data , Radiation Exposure/adverse effects , Research Design , Sample Size
17.
J Nucl Med ; 62(4): 561-567, 2021 04.
Article En | MEDLINE | ID: mdl-32859701

The use of synaptic vesicle glycoprotein 2A radiotracers with PET imaging could provide a way to measure synaptic density quantitatively in living humans. 11C-UCB-J ((R)-1-((3-(11C-methyl-11C)pyridin-4-yl)methyl)-4-(3,4,5-trifluorophenyl)pyrrolidin-2-one), previously developed and assessed in nonhuman primates and humans, showed excellent kinetic properties as a PET radioligand. However, it is labeled with the short half-life isotope 11C. We developed a new tracer, an 18F-labeled difluoro-analog of UCB-J (18F-SynVesT-1, also known as 18F-SDM-8), which displayed favorable properties in monkeys. The purpose of this first-in-human study was to assess the kinetic and binding properties of 18F-SynVesT-1 and compare with 11C-UCB-J. Methods: Eight healthy volunteers participated in a baseline study of 18F-SynVesT-1. Four of these subjects were also scanned after a blocking dose of the antiepileptic drug levetiracetam (20 mg/kg). Metabolite-corrected arterial input functions were measured. Regional time-activity curves were analyzed using 1-tissue-compartment (1TC) and 2-tissue-compartment (2TC) models and multilinear analysis 1 to compute total distribution volume (VT) and binding potential (BPND). The centrum semiovale was used as a reference region. The Lassen plot was applied to compute levetiracetam occupancy and nondisplaceable distribution volume. SUV ratio-1 (SUVR-1) over several time windows was compared with BPNDResults: Regional time-activity curves were fitted better with the 2TC model than the 1TC model, but 2TC VT estimates were unstable. The 1TC VT values matched well with those from the 2TC model (excluding the unstable values). Thus, 1TC was judged as the most useful model for quantitative analysis of 18F-SynVesT-1 imaging data. The minimum scan time for stable VT measurement was 60 min. The rank order of VT and BPND was similar between 18F-SynVesT-1 and 11C-UCB-J. Regional VT was slightly higher for 11C-UCB-J, but BPND was higher for 18F-SynVesT-1, though these differences were not significant. Levetiracetam reduced the uptake of 18F-SynVesT-1 in all regions and produced occupancy of 85.7%. The SUVR-1 of 18F-SynVesT-1 from 60 to 90 min matched best with 1TC BPNDConclusion: The novel synaptic vesicle glycoprotein 2A tracer, 18F-SynVesT-1, displays excellent kinetic and in vivo binding properties in humans and holds great potential for the imaging and quantification of synaptic density in neuropsychiatric disorders.


GPI-Linked Proteins/metabolism , Positron-Emission Tomography/methods , Pyridines/metabolism , Pyrrolidinones/metabolism , Synaptic Vesicles/metabolism , Adult , Female , Healthy Volunteers , Humans , Ligands , Male , Positron-Emission Tomography/adverse effects , Pyridines/adverse effects , Pyrrolidinones/adverse effects , Safety
18.
J Nucl Med ; 62(4): 553-560, 2021 04.
Article En | MEDLINE | ID: mdl-32859711

This was a first-in-human study of the PET radiotracer 11C-LSN3172176 for the muscarinic acetylcholine receptor subtype M1. The objectives of the study were to determine the appropriate kinetic model to quantify binding of the tracer to M1 receptors, and the reliability of the chosen quantification method. Methods: Six healthy subjects completed the test-retest protocol, and 5 healthy subjects completed the baseline-scopolamine blocking protocol. Multiple modeling methods were applied to calculate total distribution volume (VT) and nondisplaceable binding potential (BPND) in various brain regions. The reference region was selected from the blocking study. The occupancy plot was applied to compute receptor occupancy by scopolamine and nondisplaceable distribution volume. Results: Tracer uptake was highest in the striatum, followed by neocortical regions and white matter, and lowest in the cerebellum. Regional time-activity curves were fitted well by all models. The 2-tissue-compartment (2TC) model fits were good, but the 2TC parameters often could not be reliably estimated. Because VT correlated well between the 2TC and 1-tissue-compartment (1TC) models after exclusion of unreliable estimates, the 1TC model was chosen as the most appropriate. The cerebellum showed the lowest VT, consistent with preclinical studies showing little to no specific binding in the region. Further, cerebellar VT did not change between baseline and blocking scans, indicating that the cerebellum is a suitable reference region. The simplified reference tissue model (SRTM) slightly underestimated 1TC BPND, and the simplified reference tissue model 2 (SRTM2) improved BPND estimation. An 80-min scan was sufficient to quantify VT and BPND The test-retest study showed excellent absolute test-retest variability for 1TC VT (≤5%) and BPND (≤10%). In the baseline and blocking studies, occupancy values were lower in the striatum than in nonstriatal regions, as may be attributed to differences in regional acetylcholine concentrations. Conclusion: The 1TC and SRTM2 models are appropriate for quantitative analysis of 11C-LSN3172176 imaging data. 11C-LSN3172176 displayed excellent test-retest reproducibility and is a highly promising ligand to quantify M1 receptors in the human brain.


Indoles/metabolism , Piperidines/metabolism , Positron-Emission Tomography/methods , Receptor, Muscarinic M1/metabolism , Adult , Brain/metabolism , Female , Humans , Indoles/adverse effects , Indoles/chemistry , Kinetics , Ligands , Male , Piperidines/adverse effects , Piperidines/chemistry , Positron-Emission Tomography/adverse effects , Radioactive Tracers , Radiochemistry , Safety
20.
Mayo Clin Proc ; 95(1): 157-163, 2020 01.
Article En | MEDLINE | ID: mdl-31902411

With improvement in the cure rates for diffuse large B cell lymphoma, the question of surveillance imaging in patients who achieve complete remission after the initial therapy has become relevant. Some of the clinical practice guidelines recommend surveillance scanning. However, several studies have reported no benefit in overall survival with scans. Moreover, studies have highlighted an increased risk for developing secondary malignancies because of exposure to ionizing radiation from the scans. Different international societies have contrasting guidelines for the role of surveillance computerized tomography scans in patients who achieve complete remission after first-line therapy. Any benefit of surveillance imaging must be balanced by the costs, risk of radiation exposure, and lack of survival benefit. The PubMed platform was searched using relevant keywords for English-language articles with no date restrictions. Search terms were cross-referenced with review articles, and additional articles were identified by manually searching reference lists. Results were reviewed by the authors and selected for inclusion based on relevance. We present a review of this current data available for surveillance imaging in patients with diffuse large B cell lymphoma.


Lymphoma, Large B-Cell, Diffuse/diagnostic imaging , Positron-Emission Tomography , Tomography, X-Ray Computed , Humans , Lymphoma, Large B-Cell, Diffuse/therapy , Positron-Emission Tomography/adverse effects , Positron-Emission Tomography/methods , Prognosis , Remission Induction/methods , Risk Assessment , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/methods
...