Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.244
1.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38767127

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Cryosurgery , Pulmonary Veins , Cryosurgery/methods , Cryosurgery/instrumentation , Cryosurgery/adverse effects , Animals , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Swine , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Humans , Models, Cardiovascular , Muscle, Skeletal/surgery , Models, Anatomic
3.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Article En | MEDLINE | ID: mdl-38655693

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Middle Aged , Catheter Ablation/instrumentation , Catheter Ablation/methods , Catheter Ablation/adverse effects , Prospective Studies , Aged , Time Factors , Heart Rate , Action Potentials , Electrocardiography, Ambulatory/instrumentation , Recurrence , Cardiac Catheters , Predictive Value of Tests , Treatment Outcome , Imaging, Three-Dimensional , Risk Factors , Equipment Design , Electrophysiologic Techniques, Cardiac
4.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38682165

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation. Confirmation of PVI can be challenging due to the presence of far-field electrograms (EGMs) and sometimes requires additional pacing manoeuvres or mapping. This prospective multicentre study assessed the agreement between a previously trained automated algorithm designed to determine vein isolation status with expert opinion in a real-world clinical setting. METHODS AND RESULTS: Consecutive patients scheduled for PVI were recruited at four centres. The ECGenius electrophysiology (EP) recording system (CathVision ApS, Copenhagen, Denmark) was connected in parallel with the existing system in the laboratory. Electrograms from a circular mapping catheter were annotated during sinus rhythm at baseline pre-ablation, time of isolation, and post-ablation. The ground truth for isolation status was based on operator opinion. The algorithm was applied to the collected PV signals off-line and compared with expert opinion. The primary endpoint was a sensitivity and specificity exceeding 80%. Overall, 498 EGMs (248 at baseline and 250 at PVI) with 5473 individual PV beats from 89 patients (32 females, 62 ± 12 years) were analysed. The algorithm performance reached an area under the curve (AUC) of 92% and met the primary study endpoint with a sensitivity and specificity of 86 and 87%, respectively (P = 0.005; P = 0.004). The algorithm had an accuracy rate of 87% in classifying the time of isolation. CONCLUSION: This study validated an automated algorithm using machine learning to assess the isolation status of pulmonary veins in patients undergoing PVI with different ablation modalities. The algorithm reached an AUC of 92%, with both sensitivity and specificity exceeding the primary study endpoints.


Atrial Fibrillation , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Machine Learning , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Prospective Studies , Aged , Electrophysiologic Techniques, Cardiac/methods , Treatment Outcome , Reproducibility of Results , Predictive Value of Tests , Action Potentials , Heart Rate , Algorithms , Signal Processing, Computer-Assisted
5.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38607938

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Recurrence , Registries , Reoperation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Male , Middle Aged , Aged , Time Factors , Switzerland/epidemiology , Risk Factors , Treatment Outcome , Prospective Studies
6.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Article En | MEDLINE | ID: mdl-38639381

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Atrial Fibrillation , Cardiac Pacing, Artificial , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Pacing, Artificial/methods , Aged , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Retrospective Studies , Pericardium/surgery , Pericardium/physiopathology , Heart Conduction System/physiopathology , Action Potentials , Electrophysiologic Techniques, Cardiac , Heart Rate/physiology
7.
Cardiovasc Pathol ; 71: 107640, 2024.
Article En | MEDLINE | ID: mdl-38604505

Exertional dyspnea has been documented in US military personnel after deployment to Iraq and Afghanistan. We studied whether continued exertional dyspnea in this patient population is associated with pulmonary vascular disease (PVD). We performed detailed histomorphometry of pulmonary vasculature in 52 Veterans with biopsy-proven post-deployment respiratory syndrome (PDRS) and then recruited five of these same Veterans with continued exertional dyspnea to undergo a follow-up clinical evaluation, including symptom questionnaire, pulmonary function testing, surface echocardiography, and right heart catheterization (RHC). Morphometric evaluation of pulmonary arteries showed significantly increased intima and media thicknesses, along with collagen deposition (fibrosis), in Veterans with PDRS compared to non-diseased (ND) controls. In addition, pulmonary veins in PDRS showed increased intima and adventitia thicknesses with prominent collagen deposition compared to controls. Of the five Veterans involved in our clinical follow-up study, three had borderline or overt right ventricle (RV) enlargement by echocardiography and evidence of pulmonary hypertension (PH) on RHC. Together, our studies suggest that PVD with predominant venular fibrosis is common in PDRS and development of PH may explain exertional dyspnea and exercise limitation in some Veterans with PDRS.


Afghan Campaign 2001- , Hypertension, Pulmonary , Pulmonary Artery , Humans , Male , Pulmonary Artery/pathology , Pulmonary Artery/physiopathology , Pulmonary Artery/diagnostic imaging , Adult , Hypertension, Pulmonary/pathology , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/etiology , Middle Aged , Female , Iraq War, 2003-2011 , Pulmonary Veins/pathology , Pulmonary Veins/physiopathology , Pulmonary Veins/diagnostic imaging , Dyspnea/etiology , Dyspnea/physiopathology , Veterans , Case-Control Studies , Veterans Health , Biopsy , Fibrosis
8.
J Cardiovasc Electrophysiol ; 35(5): 886-894, 2024 May.
Article En | MEDLINE | ID: mdl-38433316

INTRODUCTION: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using power-controlled ablation catheters with conventional power ranges was the norm. There has been increased adoption of a high-power and very high-power short-duration ablation practice propelled by the availability of the temperature-controlled radiofrequency QDOT MICRO catheter. METHODS: There are fundamental differences in biophysics between very high-powered temperature guided ablation and conventional ablation strategy that may impact patient outcomes. The catheter's design and ablation modes offer flexibility in technique while accommodating the individual operator's clinical discretion and preference to deliver a durable, transmural, and contiguous lesion set. RESULTS: Here, we provide recommendations for 3 different workflows using the QDOT MICRO catheter in a step-by-step manner for pulmonary vein isolation based on our cumulative experience as early adopters of the technology and the data available in the scientific literature. CONCLUSIONS: With standardization, temperature-controlled ablation with the QDOT MICRO catheter provides operators the flexibility of implementing different ablation strategies to ensure durable contiguous pulmonary vein isolation depending on patient characteristics.


Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Equipment Design , Pulmonary Veins , Humans , Action Potentials , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/instrumentation , Heart Rate , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Temperature , Time Factors , Treatment Outcome , Workflow
9.
J Am Soc Echocardiogr ; 37(5): 530-537, 2024 May.
Article En | MEDLINE | ID: mdl-38341053

BACKGROUND: Data on the prognostic factors after mitral valve (MV) transcatheter edge-to-edge repair (TEER; MV-TEER) are limited. Pulsed-wave Doppler interrogation of pulmonary vein flow (PVF) is a convenient method to assess the hemodynamic burden of residual mitral regurgitation (MR), which could be of utility as a predictor of outcomes. METHODS: Patients that underwent MV-TEER between May 2014 and December 2021 at our institution were evaluated. Pulmonary vein flow patterns post-MV-TEER were reviewed on the procedural transesophageal echocardiogram and classified as normal (systolic dominant or codominant) or abnormal (systolic blunting or reversal). The PVF pattern was correlated with all-cause mortality at follow-up. RESULTS: Two-hundred sixty-five patients had diagnostic PVF post-MV-TEER, with 73 (27.5%) categorized as normal and 192 (72.5%) categorized as abnormal. Patients with abnormal PVF morphology were more likely to have atrial fibrillation (70% vs 42%, P < .001) and greater than moderate residual MR (16% vs 3%, P = .01) and had higher mean left atrial pressure (18.1 ± 5.0 vs 15.9 ± 4.2 mm Hg, P = .002) and left atrial V wave (26.6 ± 8.5 vs 21.4 ± 7.3 mm Hg, P < .001) postprocedure. In multivariable analysis, abnormal PVF morphology post-MV-TEER was independently associated with mortality at follow-up (hazard ratio = 1.70; 95% CI, 1.06-2.74; P = .03) after correction for end-stage renal disease, atrial fibrillation, and residual MR. Results were similar in subgroups of patients with moderate or less and those with mild or less residual MR. CONCLUSIONS: Pulmonary vein flow morphology is a simple and objective tool to assess MR severity immediately post-MV-TEER and offers important prognostic information to optimize procedural results. Additional studies are needed to determine whether patients with abnormal PVF pattern post-MV-TEER would benefit from more intensive goal-directed medical therapy postprocedure.


Cardiac Catheterization , Echocardiography, Transesophageal , Mitral Valve Insufficiency , Mitral Valve , Pulmonary Veins , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Male , Female , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Aged , Echocardiography, Transesophageal/methods , Cardiac Catheterization/methods , Retrospective Studies , Survival Rate , Prognosis , Echocardiography, Doppler, Pulsed/methods
11.
Heart Rhythm ; 21(6): 752-761, 2024 Jun.
Article En | MEDLINE | ID: mdl-38286244

BACKGROUND: Focal and rotational activations have been demonstrated in atrial fibrillation (AF), but their relationship to each other and to structural remodeling remains unclear. OBJECTIVE: The purpose of this study was to assess the relationship of focal and rotational activations to underlying low-voltage zones (LVZs) (<0.5 mV) and to determine whether there was a temporal (≤500 ms) and spatial (≤12 mm) relationship between these activations. METHODS: Patients undergoing catheter ablation for persistent AF were included. All patients underwent pulmonary vein isolation. Unipolar signals were collected to identify focal and rotational activations using a wavefront propagation algorithm. RESULTS: In 40 patients, 105 activations were identified (57 [54.3%] focal; 48 [45.7%] rotational). Rotational activations were co-localized to LVZs (35/48 [72.9%]) whereas focal activations were not (11/57 in LVZ [19.3%]; P <.001). The proportion of the left atrium occupied by LVZs predicted rotational activations occurrence (area under the curve 0.96; 95% confidence interval 0.90-1.00; P <.001). In patients with a relatively healthy atrium, in which the atrium consisted of ≤15% LVZs, only focal activations were identified. Thirty-two of the 35 rotational activations (91.4%) located in LVZs also showed a temporal and spatial relationship to a focal activation. The presence of a LVZ within 12 mm of the focal activation was a strong predictor for whether a paired rotational activation would also occur in that vicinity. CONCLUSION: Rotational activations are largely confined to areas of structural remodeling and have a clear spatial and temporal relationship with focal activations suggesting they are dependent on them. These novel mechanistic observations outline a plausible model for patient-specific mechanisms maintaining AF.


Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Male , Female , Middle Aged , Catheter Ablation/methods , Atrial Remodeling/physiology , Pulmonary Veins/physiopathology , Pulmonary Veins/surgery , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Aged , Follow-Up Studies
12.
Rev. urug. cardiol ; 38(1): e405, 2023. ilus, tab
Article Es | LILACS, UY-BNMED, BNUY | ID: biblio-1515549

La ablación de las venas pulmonares se ha convertido en un tratamiento clave para fibrilación auricular (FA). Sin embargo, pueden ocurrir recurrencias. La estrategia disponible para la ablación después de una recurrencia de FA es controvertida, compleja y desafiante, y la información es limitada. Mediante la presentación de una serie de casos se resumen y discuten elementos clave en la comprensión y tratamiento del paciente con FA recurrente sintomática después de un procedimiento inicial de ablación de venas pulmonares que requiere un nuevo procedimiento de ablación. En las últimas décadas se ha obtenido una mejor comprensión de los mecanismos fisiopatológicos implicados en la FA recurrente posterior a ablación de venas pulmonares, lo que permite identificar factores asociados, crear scores predictores e implementar técnicas de optimización o estrategias adicionales para mejorar la durabilidad y la eficacia del aislamiento de venas pulmonares. Debido a que la reconexión de venas pulmonares es un hallazgo típico durante los procedimientos repetidos, ésta debe ser considerada el objetivo principal de una nueva ablación. Las estrategias de ablación adicional (desencadenantes extrapulmonares o sustratos arritmogénicos) son controvertidas y requieren investigaciones futuras.


Pulmonary vein ablation has become a key treatment for atrial fibrillation (AF). However, recurrences can occur. The ideal strategy for ablation after AF recurrence is controversial, complex, and challenging, with limited data available. By presenting a series of cases, we summarize and discuss key elements in the understanding and treatment of patients with symptomatic recurrent AF after an initial pulmonary vein ablation procedure who are subjected to a new ablation procedure. In recent decades, there has been a better understanding of the pathophysiological mechanisms involved in recurrent AF after pulmonary vein ablation, making it possible to identify associated factors, create predictive scores and implement optimization techniques or additional strategies to improve the durability and efficacy of pulmonary veins isolation. Because pulmonary vein reconnection is a typical finding during repeat procedures, it should be considered the primary goal for a repeat ablation procedure. Additional ablation strategies (extrapulmonary triggers or arrhythmogenic substrates) are controversial and require further investigation.


A ablação das veias pulmonares tornou-se um tratamento chave para fibrilação atrial (FA). No entanto, podem ocorrer recorrências. A estratégia ideal para a ablação após uma recorrência da FA é controversa, complexa e desafiadora e existem dados limitados. Através da apresentação de uma série de casos resumimos e discutimos elementos chave no entendimento e tratamento do paciente com FA recorrente sintomática após um procedimento inicial de ablação de veias pulmonares, que são submetidos a um novo procedimento de ablação. Nas últimas décadas obteve-se uma melhor compressão dos mecanismos fisiopatológicos envolvidos na FA recorrente pós-ablação de veias pulmonares, isso permite identificar fatores associados, criar scores preditores, implementar técnicas de otimização ou estratégias adicionais para melhorar a durabilidade e eficácia do isolamento de veias pulmonares. Dado que a reconexão de veias pulmonares é um achado típico durante os procedimentos repetidos deve ser considerado o objetivo principal para uma nova ablação. As estratégias de ablação adicional (desencadeadores extrapulmonares ou substratos arritmogénicos) são controversas e requerem investigação futura.


Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/physiopathology , Recurrence , Atrial Fibrillation/physiopathology
14.
Respir Res ; 23(1): 29, 2022 Feb 14.
Article En | MEDLINE | ID: mdl-35164757

BACKGROUND: Chest computed tomography (CT) is a widely used method to assess morphological and dynamic abnormalities in chronic obstructive pulmonary disease (COPD). The small pulmonary vascular cross-section (CSA), quantitatively extracted from volumetric CT, is a reliable indicator for predicting pulmonary vascular changes. CSA is associated with the severity of symptoms, pulmonary function tests (PFT) and emphysema and in COPD patients the severity increases over time. We analyzed the correlation longitudinal changes in pulmonary vascular parameters with clinical parameters in COPD patients. MATERIALS AND METHODS: A total of 288 subjects with COPD were investigated during follow up period up to 6 years. CT images were classified into five subtypes from normal to severe emphysema according to percentage of low-attenuation areas less than -950 and -856 Hounsfield units (HU) on inspiratory and expiratory CT (LAA-950, LAA-856exp). Total number of vessels (Ntotal) and total number of vessels with area less than 5 mm2 (N<5 mm) per 1 cm2 of lung surface area (LSA) were measured at 6 mm from the pleural surface. RESULTS: Ntotal/LSA and N<5 mm/LSA changed from 1.16 ± 0.27 to 0.87 ± 0.2 and from 1.02 ± 0.22 to 0.78 ± 0.22, respectively, during Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage progression. Both parameters changed from normal to severe emphysema according to CT subtype from 1.39 ± 0.21 to 0.74 ± 0.17 and from 1.18 ± 0.19 to 0.67 ± 0.15, respectively. LAA-950 and LAA-856exp were negatively correlated with Ntotal/LSA (r = - 0.738, - 0.529) and N<5 mm /LSA (r = - 0.729, -- .497). On the other hand, pulmonary function test (PFT) results showed a weak correlation with Ntotal/LSA and N<5 mm/LSA (r = 0.205, 0.210). The depth in CT subtypes for longitudinal change both Ntotal/LSA and N<5 mm/LSA was (- 0.032, - 0.023) and (- 0.027) in normal and SAD, respectively. CONCLUSIONS: Quantitative computed tomography features faithfully reflected pulmonary vessel alterations, showing in particular that pulmonary vascular alteration started.


Lung/diagnostic imaging , Multidetector Computed Tomography/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Veins/diagnostic imaging , Vascular Resistance/physiology , Adult , Aged , Aged, 80 and over , Disease Progression , Female , Follow-Up Studies , Forced Expiratory Volume/physiology , Humans , Lung/physiopathology , Male , Middle Aged , Prospective Studies , Pulmonary Artery/physiopathology , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Veins/physiopathology , Respiratory Function Tests , Time Factors
15.
BMC Cardiovasc Disord ; 22(1): 38, 2022 02 11.
Article En | MEDLINE | ID: mdl-35148671

BACKGROUND: Left atrial appendage closure (LAAC) combined with radiofrequency catheter ablation (RFCA) as a hybrid procedure is commonly performed to treat atrial fibrillation (AF). Although this treatment carries a low risk of coronary artery spasm (CAS), and has never been observed in LAAC procedure, caution still needed to be taken. We presented a case of CAS that occurred in an AF patient during the hybrid procedure. CASE PRESENTATION: The patient was a 65-year-old man with paroxysmal AF who developed CAS during RFCA and LAAC. In this case, LAAC was performed ahead of RFCA. After atrial septal puncture, the occluder was advanced into left atrium through delivery sheath, and successfully deployed in the LAA. After verifying the assessment of "PASS" criteria, we decided to release the device. However, before releasing the occluder in LAAC, the patient's blood pressure (BP) fell to 70/45 mmHg with heart rate (HR) drop and ST-segment elevation in II, III, and aVF and reciprocal ST-segment depression in I and aVL. Isotonic sodium chloride load was administered. After 3 min, the BP and HR raised, and ST-segment returned to normal. The occluder was successfully released after the stable condition of the patient. Then, RFCA was sequentially performed. When isolating the right pulmonary veins, the patient's BP and HR fell again with ST-segment elevation in inferior leads. Spontaneous ventricular tachycardia and fibrillation developed rapidly and defibrillation was performed immediately with success. Coronary angiography revealed the obstruction of the right coronary artery which disappeared completely after intracoronary nitroglycerin injection (1 mg). Under systemic diltiazem infusion, the RFCA procedure was accomplished. After the procedure, the patient recovered without any neurologic deficit, and CAS has never recurred with isosorbide mononitrate treatment during follow-up. CONCLUSIONS: CAS is a rare complication associated with AF hybrid procedure. Attention should be paid to this rare but potentially life-threatening complication.


Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Coronary Vasospasm/etiology , Coronary Vessels/physiopathology , Pulmonary Veins/surgery , Vasoconstriction , Aged , Atrial Appendage/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Coronary Angiography , Coronary Vasospasm/diagnostic imaging , Coronary Vasospasm/drug therapy , Coronary Vasospasm/physiopathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/drug effects , Electrocardiography , Humans , Male , Pulmonary Veins/physiopathology , Treatment Outcome , Vasoconstriction/drug effects , Vasodilator Agents/therapeutic use
19.
J Thorac Cardiovasc Surg ; 163(2): 387-395.e3, 2022 Feb.
Article En | MEDLINE | ID: mdl-33966882

BACKGROUND: Previous studies have demonstrated increased early mortality and pulmonary vein reintervention for patients with total anomalous pulmonary venous connection (TAPVC) and heterotaxy syndrome (HTX+) compared with patients with TAPVC without heterotaxy syndrome (HTX-). We aimed to evaluate the longitudinal risk of pulmonary vein reintervention and mortality in HTX + patients. METHODS: A retrospective review was performed to identify longitudinal interventions in patients with TAPVC seen at a single center from 1995 to 2019. The mean cumulative interventions were described for all patients using the Nelson-Aalen estimator. Survival with TAPVC was described using Kaplan-Meier estimates. RESULTS: A total of 336 patients were identified with TAPVC, of whom 118 (35%) had heterotaxy syndrome. Functional single ventricles were identified in 106 of these 118 HTX + patients (90%) and in 14 of 218 HTX- patients (6%) (P < .001). Obstructed TAPVC (OBS+) was present in 49 of 118 HTX + patients (42%) and in 87 of 218 HTX- patients (40%) (P = .89). The median duration of follow-up was 6.5 years. Five-year survival was 69% for HTX+/OBS + patients, 72% for HTX+/OBS- patients, 86% for HTX-/OBS + patients, and 95% for HTX-/OBS- patients (P < .0001, log-rank test). The mean number of pulmonary vein interventions at the median follow-up time was greater in the HTX+/OBS + patients compared with HTX+/OBS- patients (mean, 2.0 vs 1.1; P = .030), HTX-/OBS + patients (mean, 1.3; P = .033), and HTX-/OBS- patients (mean, 1.3; P = .029). CONCLUSIONS: Among the 4 cohorts, HTX+ was associated with a higher rate of mortality, and HTX+/OBS+ was associated with a greater number of pulmonary vein interventions. This may be due in part to the high prevalence of single ventricle physiology in the HTX + cohort.


Heterotaxy Syndrome , Pulmonary Veins/surgery , Pulmonary Veno-Occlusive Disease/surgery , Scimitar Syndrome/surgery , Vascular Surgical Procedures , Female , Heterotaxy Syndrome/diagnostic imaging , Heterotaxy Syndrome/mortality , Heterotaxy Syndrome/physiopathology , Humans , Male , Postoperative Complications/mortality , Postoperative Complications/surgery , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Pulmonary Veno-Occlusive Disease/diagnostic imaging , Pulmonary Veno-Occlusive Disease/mortality , Pulmonary Veno-Occlusive Disease/physiopathology , Recurrence , Reoperation , Retrospective Studies , Scimitar Syndrome/diagnostic imaging , Scimitar Syndrome/mortality , Scimitar Syndrome/physiopathology , Time Factors , Treatment Outcome , Vascular Surgical Procedures/adverse effects , Vascular Surgical Procedures/mortality
...