1 - 20 de 59.208
1.
Issues Law Med ; 39(1): 3-20, 2024.
Article En | MEDLINE | ID: mdl-38771711

Background: Nowadays, the quality of medical care and health care measures is considered the main target function of the health care system and at the same time the determining criterion for its activities. Objective: The article examines state regulation of medical care quality post- COVID and during martial law, identifying improvement areas. It emphasizes state roles in healthcare standardization, continuous feedback monitoring, and studying patient satisfaction. Interrelationships among Ukraine's state regulation mechanisms are determined, highlighting the need to enhance tools such as criteria and quality indicators for medical care assurance. Methods: The authors of this article utilize various scientific methods, including analysis, synthesis, induction, and deduction, as well as historical and legal, formal legal, and comparative legal methods to examine the state regulation of ensuring the quality of medical care during martial law in Ukraine. Results: The article considered the interrelationships of mechanisms and instruments of state regulation of quality assurance of medical care in Ukraine. Conclusions: The state should enhance medical care quality regulation, drawing on international experiences from the EU and the USA and adapting best practices to national circumstances. The resilience of the healthcare system depends on effective quality assurance, ensuring preparedness, stability, and ongoing improvement prospects.


Quality of Health Care , Ukraine , Humans , Quality of Health Care/legislation & jurisprudence , COVID-19 , Quality Assurance, Health Care/legislation & jurisprudence , Government Regulation , Delivery of Health Care/legislation & jurisprudence , SARS-CoV-2 , State Government
2.
BMC Surg ; 24(1): 158, 2024 May 17.
Article En | MEDLINE | ID: mdl-38760789

BACKGROUND: This study analyses the association between hospital ownership and patient selection, treatment, and outcome of carotid endarterectomy (CEA) or carotid artery stenting (CAS). METHODS: The analysis is based on the Bavarian subset of the nationwide German statutory quality assurance database. All patients receiving CEA or CAS for carotid artery stenosis between 2014 and 2018 were included. Hospitals were subdivided into four groups: university hospitals, public hospitals, hospitals owned by charitable organizations, and private hospitals. The primary outcome was any stroke or death until discharge from hospital. Research was funded by Germany's Federal Joint Committee Innovation Fund (01VSF19016 ISAR-IQ). RESULTS: In total, 22,446 patients were included. The majority of patients were treated in public hospitals (62%), followed by private hospitals (17%), university hospitals (16%), and hospitals under charitable ownership (6%). Two thirds of patients were male (68%), and the median age was 72 years. CAS was most often applied in university hospitals (25%) and most rarely used in private hospitals (9%). Compared to university hospitals, patients in private hospitals were more likely asymptomatic (65% vs. 49%). In asymptomatic patients, the risk of stroke or death was 1.3% in university hospitals, 1.5% in public hospitals, 1.0% in hospitals of charitable owners, and 1.2% in private hospitals. In symptomatic patients, these figures were 3.0%, 2.5%, 3.4%, and 1.2% respectively. Univariate analysis revealed no statistically significant differences between hospital groups. In the multivariable analysis, compared to university hospitals, the odds ratio of stroke or death in asymptomatic patients treated by CEA was significantly lower in charitable hospitals (OR 0.19 [95%-CI 0.07-0.56, p = 0.002]) and private hospitals (OR 0.47 [95%-CI 0.23-0.98, p = 0.043]). In symptomatic patients (elective treatment, CEA), patients treated in private or public hospitals showed a significantly lower odds ratio compared to university hospitals (0.36 [95%-CI 0.17-0.72, p = 0.004] and 0.65 [95%-CI 0.42-1.00, p = 0.048], respectively). CONCLUSIONS: Hospital ownership was related to patient selection and treatment, but not generally to outcomes. The lower risk of stroke or death in the subgroup of electively treated patients in private hospitals might be due to the right timing, the choice of treatment modality or actually to better structural and process quality.


Carotid Stenosis , Databases, Factual , Endarterectomy, Carotid , Ownership , Patient Selection , Stents , Humans , Male , Female , Aged , Germany/epidemiology , Carotid Stenosis/surgery , Treatment Outcome , Quality Assurance, Health Care , Hospitals, Private/statistics & numerical data , Middle Aged , Stroke/epidemiology , Aged, 80 and over , Hospitals, Public/statistics & numerical data , Secondary Data Analysis
3.
Rev Med Liege ; 79(S1): 16-19, 2024 May.
Article Fr | MEDLINE | ID: mdl-38778644

Radiation therapy is the use of radiation to treat cancer cells while preserving healthy tissue. More than half of cancer patients will receive radiation therapy at some point during their treatment. The implementation of a Quality Management System (QMS) in radiotherapy departments guarantees high quality care and optimal safety for patients. The QMS is a set of policies, procedures and processes aimed at ensuring effective management of the quality of treatments. It is crucial for planning, implementing, monitoring and continuously improving the care of radiotherapy patients. The benefits of the QMS for patients are multiple. It provides high quality support through specific protocols and deadlines. The security of processing is reinforced by the continuous training of personnel, the monitoring of incidents and the analysis of errors. Developing a culture of safety and continuous improvement also helps to minimize risk. In conclusion, the implementation of a QMS in radiotherapy departments guarantees quality care, secure and adapted to the individual needs of patients. This improves patient satisfaction while reducing the risk of errors.


La radiothérapie consiste à utiliser des radiations pour traiter les cellules cancéreuses, tout en préservant les tissus sains. Plus de la moitié des patients atteints de cancer recevront une radiothérapie à un moment donné de leur traitement. La mise en place d'un Système de Management Qualité (SMQ) dans les services de radiothérapie garantit des soins de haute qualité et une sécurité optimale pour les patients. Le SMQ est un ensemble de politiques, procédures et processus visant à assurer la gestion efficace de la qualité des traitements. Il est crucial pour planifier, implémenter, contrôler et améliorer continuellement la prise en charge des patients en radiothérapie. Les avantages du SMQ sont multiples. Il assure une prise en charge de haute qualité grâce à des protocoles et des délais spécifiques. La sécurité des traitements est renforcée par la formation continue du personnel, la surveillance des incidents et l'analyse des erreurs. Le développement d'une culture de sécurité et d'amélioration continue contribue également à minimiser les risques. En conclusion, la mise en place d'un SMQ dans les services de radiothérapie garantit des traitements de qualité, sécurisés et adaptés aux besoins individuels des patients. Cette approche améliore la satisfaction des patients, tout en réduisant les risques d'erreurs.


Patient Safety , Radiotherapy , Humans , Radiotherapy/standards , Radiotherapy/adverse effects , Radiotherapy/methods , Quality Assurance, Health Care , Neoplasms/radiotherapy
4.
Transpl Int ; 37: 12627, 2024.
Article En | MEDLINE | ID: mdl-38751769

Background A quality assurance programme for the tissue donation process was launched in Andalusia in 2020 to facilitate the integration of tissue donation into end-of-life care, and to respond to the growing need for human tissue for therapeutic purposes. The results of this programme are presented here. Methods After identifying the hospital departments in which to intensify the detection of tissue donors, expanding training activities and designing a specific data collection system for possible tissue donors who do not donate their tissues, the results of the donation activity were quantified and the causes of non-donation were analysed by applying the critical pathway for deceased tissue donation methodology. Results After an initial drop in activity, which coincided with the coronavirus pandemic, the number of tissue donors increased by 48.4% in 2022 compared to 2019. From the eligible donors, 83% were actual tissue donors and 71% were utilised donors. The modifiable causes of tissue donation loss, in order of frequency, were family refusal, followed by organisational or logistical issues, failure to notify or failure to identify possible donors, and failure to complete donor evaluation. Conclusion As a result of the collaboration of the various professionals involved in the programme, tissue donation activity has increased remarkably, the potential and effectiveness of the donation process have been evaluated, and areas for improvement have been identified, which we hope will lead to continuous improvement of the process.


COVID-19 , Quality Assurance, Health Care , Tissue Donors , Tissue and Organ Procurement , Humans , Tissue and Organ Procurement/standards , Tissue Donors/supply & distribution , COVID-19/epidemiology , Spain , SARS-CoV-2 , Terminal Care
5.
Sci Rep ; 14(1): 10637, 2024 05 09.
Article En | MEDLINE | ID: mdl-38724569

Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.


Radiometry , Radiometry/instrumentation , Radiometry/methods , Humans , Radiotherapy/methods , Radiotherapy/standards , Radiotherapy/instrumentation , Quality Assurance, Health Care , Electrons , Radiotherapy Dosage , Neoplasms/radiotherapy , Equipment Design , Proton Therapy/instrumentation , Proton Therapy/methods
6.
Semin Perinatol ; 48(3): 151902, 2024 Apr.
Article En | MEDLINE | ID: mdl-38692996

The American Academy of Pediatrics (AAP) Standards for Levels of Neonatal Care, published in 2023, highlights key components of a Neonatal Patient Safety and Quality Improvement Program (NPSQIP). A comprehensive Neonatal Intensive Care Unit (NICU) quality and safety infrastructure (QSI) is based on four foundational domains: quality improvement, quality assurance, safety culture, and clinical guidelines. This paper serves as an operational guide for NICU clinical leaders and quality champions to navigate these domains and develop their local QSI to include the AAP NPSQIP standards.


Intensive Care Units, Neonatal , Patient Safety , Quality Improvement , Humans , Intensive Care Units, Neonatal/standards , Intensive Care Units, Neonatal/organization & administration , Patient Safety/standards , Infant, Newborn , Quality Assurance, Health Care , Practice Guidelines as Topic , United States , Organizational Culture , Safety Management/standards , Safety Management/organization & administration
7.
Clin Lab ; 70(5)2024 May 01.
Article En | MEDLINE | ID: mdl-38747911

BACKGROUND: This study aims to evaluate the ability of laboratories to perform spinal muscular atrophy (SMA) genetic testing in newborns based on dried blood spot (DBS) samples, and to provide reference data and advance preparation for establishing the pilot external quality assessment (EQA) scheme for SMA genetic testing of newborns in China. METHODS: The pilot EQA scheme contents and evaluation principles of this project were designed by National Center for Clinical Laboratories (NCCL), National Health Commission. Two surveys were carried out in 2022, and 5 batches of blood spots were submitted to the participating laboratory each time. All participating laboratories conducted testing upon receiving samples, and test results were submitted to NCCL within the specified date. RESULTS: The return rates were 75.0% (21/28) and 95.2% (20/21) in the first and second surveys, respectively. The total return rate of the two examinations was 83.7% (41/49). Nineteen laboratories (19/21, 90.5%) had a full score passing on the first survey, while in the second survey twenty laboratories (20/20, 100%) scored full. CONCLUSIONS: This pilot EQA survey provides a preliminary understanding of the capability of SMA genetic testing for newborns across laboratories in China. A few laboratories had technical or operational problems in testing. It is, therefore, of importance to strengthen laboratory management and to improve testing capacity for the establishment of a national EQA scheme for newborn SMA genetic testing.


Genetic Testing , Muscular Atrophy, Spinal , Neonatal Screening , Humans , Infant, Newborn , Muscular Atrophy, Spinal/diagnosis , Muscular Atrophy, Spinal/genetics , Pilot Projects , Genetic Testing/standards , Genetic Testing/methods , Neonatal Screening/standards , Neonatal Screening/methods , China , Dried Blood Spot Testing/standards , Dried Blood Spot Testing/methods , Quality Assurance, Health Care , Laboratories, Clinical/standards , Survival of Motor Neuron 1 Protein/genetics
8.
Clin Biochem ; 127-128: 110764, 2024 May.
Article En | MEDLINE | ID: mdl-38636695

Quality in laboratory medicine encompasses multiple components related to total quality management, including quality control (QC), quality assurance (QA), quality indicators, and quality improvement (QI). Together, they contribute to minimizing errors (pre-analytical, analytical, or post-analytical) in clinical service delivery and improving process appropriateness and efficiency. In contrast to static quality benchmarks (QC, QA, quality indicators), the QI paradigm is a continuous approach to systemic process improvement for optimizing patient safety, timeliness, effectiveness, and efficiency. Healthcare institutions have placed emphasis on applying the QI framework to identify and improve healthcare delivery. Despite QI's increasing importance, there is a lack of guidance on preparing, executing, and sustaining QI initiatives in the field of laboratory medicine. This has presented a significant barrier for clinical laboratorians to participate in and lead QI initiatives. This three-part primer series will bridge this knowledge gap by providing a guide for clinical laboratories to implement a QI project that issuccessful and sustainable. In the first article, we introduce the steps needed to prepare a QI project with focus on relevant methodology and tools related to problem identification, stakeholder engagement, root cause analysis (e.g., fishbone diagrams, Pareto charts and process mapping), and SMART aim establishment. Throughout, we describe a clinical vignette of a real QI project completed at our institution focused on serum protein electrophoresis (SPEP) utilization. This primer series is the first of its kind in laboratory medicine and will serve as a useful resource for future engagement of clinical laboratory leaders in QI initiatives.


Laboratories, Clinical , Quality Improvement , Humans , Quality Control , Quality Assurance, Health Care
9.
Asian Pac J Cancer Prev ; 25(4): 1425-1432, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38680004

AIM: This study comprehensively investigated pre-treatment quality assurance (QA) for 100 cancer patients undergoing stereotactic treatments (SRS/SRT) using various detectors. METHODS: The study conducted QA for SRS/SRT treatments planned with a 6MV SRS beam at a dose rate of 1,000 MU/min, utilizing Eclipse v13.6 Treatment Planning System (TPS). Point dose measurements employed 0.01cm3 and 0.13cm3 cylindrical ionization chambers, while planar dose verification utilized Gafchromic EBT-XD Film and Portal Imager (aS1000). Plans were categorized by target volume, and a thorough analysis compared point dose agreements, planar dose gamma pass rates, and their correlations with chamber volume mean dose, detector type, and point dose agreement. Additionally, the consistency between different ionization chambers was assessed. RESULTS: Point dose agreement generally improved with increasing target volume, except for volumes over 10cm3 with 0.01cm3 chambers, showing a contrary trend. Significant differences (p<0.05) were observed between TPS and measured doses for both chambers. Gamma pass rate improved with increasing target volume in EBT XD and aS1000 analyses, except for the >10cm3 group in EBT XD. EBT XD demonstrated better agreement with TPS for target volumes up to 10cm3 compared to aS1000, with a statistically significant difference (p<0.05) between the detectors. Strong correlations were found between chamber point dose and chamber volume mean dose agreement, as well as between the two gamma criteria analyses of the same detector type in the planar dose correlation analysis. However, weak correlations were discovered for other analyses. CONCLUSION: This study found weak correlation between different detector types in pre-treatment QA for point dose and planar dose evaluation. However, within a specific detector type, strong correlation was observed for different point dose evaluation methods and gamma criteria. This highlights the importance of cautious interpretation of QA results, particularly for SRS QA, due to the lack of correlation between detector types.


Neoplasms , Quality Assurance, Health Care , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/standards , Quality Assurance, Health Care/standards , Neoplasms/radiotherapy , Radiometry/methods , Radiotherapy, Intensity-Modulated/methods
10.
J Appl Clin Med Phys ; 25(5): e14343, 2024 May.
Article En | MEDLINE | ID: mdl-38569013

PURPOSE: Single-isocenter multi-target intracranial stereotactic radiotherapy (SIMT) is an effective treatment for brain metastases with complex treatment plans and delivery optimization necessitating rigorous quality assurance. This work aims to assess five methods for quality assurance of SIMT treatment plans in terms of their suitability and sensitivity to delivery errors. METHODS: Sun Nuclear ArcCHECK and SRS MapCHECK, GafChromic EBT Radiochromic Film, machine log files, and Varian Portal Dosimetry were all used to measure 15 variations of a single SIMT plan. Variations of the original plan were created with Python. They comprised various degrees of systematic MLC offsets per leaf up to 2 mm, random per-leaf variations with differing minimum and maximum magnitudes, simulated collimator, and dose miscalibrations (MU scaling). The erroneous plans were re-imported into Eclipse and plan-quality degradation was assessed by comparing each plan variation to the original clinical plan in terms of the percentage of clinical goals passing relative to the original plan. Each erroneous plan could be then ranked by the plan-quality degradation percentage following recalculation in the TPS so that the effects of each variation could be correlated with γ pass rates and detector suitability. RESULTS & CONCLUSIONS: It was found that 2%/1 mm is a good starting point for the ArcCHECK, Portal Dosimetry, and the SRS MapCHECK methods, respectively, and provides clinically relevant error detection sensitivity. Looser dose criteria of 5%/1 mm or 5%/1.5 mm are suitable for film dosimetry and log-file-based methods. The statistical methods explored can be expanded to other areas of patient-specific QA and detector assessment.


Brain Neoplasms , Quality Assurance, Health Care , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Brain Neoplasms/radiotherapy , Radiosurgery/methods , Radiosurgery/instrumentation , Quality Assurance, Health Care/standards , Radiotherapy, Intensity-Modulated/methods , Particle Accelerators/instrumentation , Radiometry/methods , Radiometry/instrumentation , Algorithms
11.
J Appl Clin Med Phys ; 25(5): e14337, 2024 May.
Article En | MEDLINE | ID: mdl-38576183

PURPOSE: The quality of on-board imaging systems, including cone-beam computed tomography (CBCT), plays a vital role in image-guided radiation therapy (IGRT) and adaptive radiotherapy. Recently, there has been an upgrade of the CBCT systems fused in the O-ring linear accelerators called HyperSight, featuring a high imaging performance. As the characterization of a new imaging system is essential, we evaluated the image quality of the HyperSight system by comparing it with Halcyon 3.0 CBCT and providing benchmark data for routine imaging quality assurance. METHODS: The HyperSight features ultra-fast scan time, a larger kilovoltage (kV) detector, a more substantial kV tube, and an advanced reconstruction algorithm. Imaging protocols in the two modes of operation, treatment mode with IGRT and the CBCT for planning (CBCTp) mode were evaluated and compared with Halcyon 3.0 CBCT. Image quality metrics, including spatial resolution, contrast resolution, uniformity, noise, computed tomography (CT) number linearity, and calibration error, were assessed using a Catphan and an electron density phantom and analyzed with TotalQA software. RESULTS: HyperSight demonstrated substantial improvements in contrast-to-noise ratio and noise in both IGRT and CBCTp modes compared to Halcyon 3.0 CBCT. CT number calibration error of HyperSight CBCTp mode (1.06%) closely matches that of a full CT scanner (0.72%), making it suitable for adaptive planning. In addition, the advanced hardware of HyperSight, such as ultra-fast scan time (5.9 s) or 2.5 times larger heat unit capacity, enhanced the clinical efficiency in our experience. CONCLUSIONS: HyperSight represented a significant advancement in CBCT imaging. With its image quality, CT number accuracy, and ultra-fast scans, HyperSight has a potential to transform patient care and treatment outcomes. The enhanced scan speed and image quality of HyperSight are expected to significantly improve the quality and efficiency of treatment, particularly benefiting patients.


Algorithms , Cone-Beam Computed Tomography , Image Processing, Computer-Assisted , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Cone-Beam Computed Tomography/methods , Particle Accelerators/instrumentation , Humans , Radiotherapy Planning, Computer-Assisted/methods , Image Processing, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Quality Assurance, Health Care/standards , Radiographic Image Interpretation, Computer-Assisted/methods
12.
J Appl Clin Med Phys ; 25(5): e14313, 2024 May.
Article En | MEDLINE | ID: mdl-38650177

BACKGROUND: This study utilizes interviews of clinical medical physicists to investigate self-reported shortcomings of the current weekly chart check workflow and opportunities for improvement. METHODS: Nineteen medical physicists were recruited for a 30-minute semi-structured interview, with a particular focus placed on image review and the use of automated tools for image review in weekly checks. Survey-type questions were used to gather quantitative information about chart check practices and importance placed on reducing chart check workloads versus increasing chart check effectiveness. Open-ended questions were used to probe respondents about their current weekly chart check workflow, opinions of the value of weekly chart checks and perceived shortcomings, and barriers and facilitators to the implementation of automated chart check tools. Thematic analysis was used to develop common themes across the interviews. RESULTS: Physicists ranked highly the value of reducing the time spent on weekly chart checks (average 6.3 on a scale from 1 to 10), but placed more value on increasing the effectiveness of checks with an average of 9.2 on a 1-10 scale. Four major themes were identified: (1) weekly chart checks need to adapt to an electronic record-and-verify chart environment, (2) physicists could add value to patient care by analyzing images without duplicating the work done by physicians, (3) greater support for trending analysis is needed in weekly checks, and (4) automation has the potential to increase the value of physics checks. CONCLUSION: This study identified several key shortcomings of the current weekly chart check process from the perspective of the clinical medical physicist. Our results show strong support for automating components of the weekly check workflow in order to allow for more effective checks that emphasize follow-up, trending, failure modes and effects analysis, and allow time to be spent on other higher value tasks that improve patient safety.


Workflow , Humans , Health Physics , Surveys and Questionnaires , Image Processing, Computer-Assisted/methods , Automation , Quality Assurance, Health Care/standards , Interviews as Topic/methods
13.
Clin Lab ; 70(4)2024 Apr 01.
Article En | MEDLINE | ID: mdl-38623669

BACKGROUND: We aimed to evaluate the diagnostic capabilities of Chinese laboratories for inherited metabolic disorders (IMDs) using gas chromatography-mass spectrometry (GC-MS) on urine samples. Meanwhile, based on the result of the pilot external quality assessment (EQA) scheme, we hope to establish a standardized and reliable procedure for future EQA practice. METHODS: We recruited laboratories that participated in the EQA of quantitative analysis of urinary organic acids with GC-MS before joining the surveys. In each survey, a set of five real urine samples was distributed to each participant. The participants should analyze the sample by GC-MS and report the "analytical result", "the most likely diagnosis", and "recommendation for further tests" to the NCCL before the deadline. RESULTS: A total of 21 laboratories participated in the scheme. The pass rates were 94.4% in 2020 and 89.5% in 2021. For all eight IMDs tested, the analytical proficiency rates ranged from 84.7% - 100%, and the interpretational performance rate ranged from 88.2% - 97.0%. The performance on hyperphenylalaninemia (HPA), 3-methylcrotonyl-CoA carboxylase deficiency (MCCD), and ethylmalonic encephalopathy (EE) samples were not satisfactory. CONCLUSIONS: In general, the participants of this pilot EQA scheme are equipped with the basic capability for qualitative organic acid analysis and interpretation of the results. Limited by the small size of laboratories and samples involved, this activity could not fully reflect the state of clinical practice of Chinese laboratories. NCCL will improve the EQA scheme and implement more EQA activities in the future.


Metabolic Diseases , Phenylketonurias , Humans , Quality Control , Laboratories , Metabolic Diseases/diagnosis , China , Quality Assurance, Health Care
14.
Biochem Med (Zagreb) ; 34(2): 020704, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38665870

Introduction: Clinical laboratories should guarantee sample stability in specific storage conditions for further analysis. The aim of this study is to evaluate the stability of plasma samples under refrigeration for 29 common biochemical analytes usually ordered within an emergency context, in order to determine the maximum allowable period for conducting add-on testing. Materials and methods: A total of 20 patient samples were collected in lithium heparin tubes without gel separator. All analyses were performed using Alinity systems (Abbott Laboratories, Abbott Park, USA) and samples were stored at 2-8 °C. Measurements were conducted in primary plasma tubes at specific time points up to 48 hours, with an additional stability study in plasma aliquots extending the time storage up to 96 hours. The stability limit was estimated considering the total limit of change criteria. Results: Of the 29 studied parameters, 24 demonstrated stabilities within a 48-hour storage period in primary plasma tubes. However, five analytes: aspartate aminotransferase, glucose, lactate dehydrogenase, inorganic phosphate and potassium evidenced instability at different time points (7.9 hours, 2.7 hours, 2.9 hours, 6.2 hours and 4.7 hours, respectively). The stability study in plasma aliquots showed that all parameters remained stable for 96 hours, except lactate dehydrogenase, with a stability limit of 63 hours. Conclusions: A reduced stability of primary plasma samples was observed for five common biochemical analytes ordered in an emergency context. To ensure the quality of add-on testing for these samples, plasma aliquots provide stability for a longer period.


Blood Specimen Collection , Humans , Blood Specimen Collection/standards , Blood Chemical Analysis/standards , Quality Control , Quality Assurance, Health Care , Aspartate Aminotransferases/blood , L-Lactate Dehydrogenase/blood , Plasma/chemistry , Specimen Handling/standards
15.
J Appl Clin Med Phys ; 25(5): e14328, 2024 May.
Article En | MEDLINE | ID: mdl-38553788

PURPOSE: Experimental patient-specific QA (PSQA) is a time and resource-intensive process, with a poor sensitivity in detecting errors. Radiation therapy facilities aim to substitute it by means of independent dose calculation (IDC) in combination with a comprehensive beam delivery QA program. This paper reports on the commissioning of the IDC software tool myQA iON (IBA Dosimetry) for proton therapy and its clinical implementation at the MedAustron Ion Therapy Center. METHODS: The IDC commissioning work included the validation of the beam model, the implementation and validation of clinical CT protocols, and the evaluation of patient treatment data. Dose difference maps, gamma index distributions, and pass rates (GPR) have been reviewed. The performance of the IDC tool has been assessed and clinical workflows, simulation settings, and GPR tolerances have been defined. RESULTS: Beam model validation showed agreement of ranges within ± 0.2 mm, Bragg-Peak widths within ± 0.1 mm, and spot sizes at various air gaps within ± 5% compared to physical measurements. Simulated dose in 2D reference fields deviated by -0.3% ± 0.5%, while 3D dose distributions differed by 1.8% on average to measurements. Validation of the CT calibration resulted in systematic differences of 2.0% between IDC and experimental data for tissue like samples. GPRs of 99.4 ± 0.6% were found for head, head and neck, and pediatric CT protocols on a 2%/2 mm gamma criterion. GPRs for the adult abdomen protocol were at 98.9% on average with 3%/3 mm. Root causes of GPR outliers, for example, implants were identified and evaluated. CONCLUSION: IDC has been successfully commissioned and integrated into the MedAustron clinical workflow for protons in 2021. IDC has been stepwise and safely substituting experimental PSQA since February 2021. The initial reduction of proton experimental PSQA was about 25% and reached up to 90% after 1 year.


Organs at Risk , Proton Therapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Software , Humans , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Quality Assurance, Health Care/standards , Phantoms, Imaging , Radiotherapy, Intensity-Modulated/methods , Calibration , Neoplasms/radiotherapy , Tomography, X-Ray Computed/methods , Algorithms
16.
Indian J Med Microbiol ; 48: 100552, 2024.
Article En | MEDLINE | ID: mdl-38442789

We evaluated the performance of automated susceptibility testing for piperacillin/tazobactam (PTZ) MICs against the reference microbroth dilution method. The Minimum Inhibitory Concentration of PTZ against a clinical isolate of Klebsiella pneumoniae was determined by reference broth micro-dilution method in 10 replicates which yielded a modal MIC of 16 mg/L (susceptible dose-dependent). Out of 434 laboratories who obtained MIC of 16 mg/L correctly, only 301 interpreted the result as susceptible dose dependent as per 2022 revised CLSI criteria. Educating the clinical laboratories in validating AST methods as per latest CLSI guidelines is of utmost important.


Anti-Bacterial Agents , Klebsiella pneumoniae , Microbial Sensitivity Tests , Piperacillin, Tazobactam Drug Combination , Microbial Sensitivity Tests/standards , Microbial Sensitivity Tests/methods , Humans , Piperacillin, Tazobactam Drug Combination/pharmacology , Anti-Bacterial Agents/pharmacology , Klebsiella pneumoniae/drug effects , Piperacillin/pharmacology , Klebsiella Infections/microbiology , Quality Assurance, Health Care , Penicillanic Acid/analogs & derivatives , Penicillanic Acid/pharmacology
17.
Med Phys ; 51(5): 3184-3194, 2024 May.
Article En | MEDLINE | ID: mdl-38456608

BACKGROUND: Electromagnetic tracking (EMT) systems have proven to be a valuable source of information regarding the location and geometry of applicators in patients undergoing brachytherapy (BT). As an important element of an enhanced and individualized pre-treatment verification, EMT can play a pivotal role in detecting treatment errors and uncertainties to increase patient safety. PURPOSE: The purpose of this study is two-fold: to design, develop and test a dedicated measurement protocol for the use of EMT-enabled afterloaders in BT and to collect and compare the data acquired from three different radiation oncology centers in different clinical environments. METHODS: A novel quality assurance (QA) phantom composed of a scaffold with supports to fix the field generator, different BT applicators, and reference sensors (sensor verification tools) was used to assess the precision (jitter error) and accuracy (relative distance errors and target registration error) of the EMT sensor integrated into an afterloader prototype. Measurements were repeated in different environments where EMT measurements are likely to be performed, namely an electromagnetically clean laboratory, a BT suite, an operating room, and, if available, a CT suite and an MRI suite dedicated to BT. RESULTS: The mean positional jitter was consistently under 0.1 mm across all measurement points, with a slight trend of increased jitter at greater distances from the field generator. The mean variability of sensor positioning in the tested tandem and ring gynecological applicator was also below 0.1 mm. The tracking accuracy close to the center of the measurement volume was higher than at its edges. The relative distance error at the center was 0.2-0.3 mm with maximum values reaching 1.2-1.8 mm, but up to 5.5 mm for measurement points close to the edges. In general, similar accuracy results were obtained in the clinical environments and in all investigated institutions (median distance error 0.1-0.4 mm, maximum error 1.0-2.0 mm), however, errors were found to be larger in the CT suite (median distance error up to 1.0 mm, maximum error up to 3.6 mm). CONCLUSION: The presented quality assessment protocol for EMT systems in BT has demonstrated that EMT offers a high-accuracy determination of the applicator/implant geometry even in clinical environments. In addition to that, it has provided valuable insights into the performance of EMT-enabled afterloaders across different radiation oncology centers.


Brachytherapy , Electromagnetic Phenomena , Quality Assurance, Health Care , Brachytherapy/instrumentation , Humans , Phantoms, Imaging , Quality Control
18.
Clin Chim Acta ; 557: 117876, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38493945

Metrology in clinical chemistry aims to ensure the equivalence of measurement results from different in-vitro diagnostic measurement devices (IVD MD) for use in healthcare. The metrological traceability of measurement results to higher-order references is the cornerstone to achieving equivalent results. However, other fundamentals are also needed, including the commutability of reference materials and external quality assessment (EQA) materials for monitoring the equivalence of measurement results at the end-user level. This manuscript summarizes the findings and opinions expressed at the Joint Community for Traceability in Laboratory Medicine (JCTLM) workshop held on December 4-5, 2023. The workshop explored the relationship between EQA/proficiency testing and metrological traceability to higher-order references. EQA monitors the equivalence of measurement results from end-user IVD MDs. The workshop discussed the role and challenges of using EQA to improve and maintain the equivalence of measurement results. It also elucidated current developments in establishing the clinical suitability of laboratory results expressed as analytical performance specifications (APS).


Clinical Laboratory Techniques , Laboratory Proficiency Testing , Laboratories , Quality Assurance, Health Care , Reference Standards
19.
Radiol Phys Technol ; 17(2): 389-395, 2024 Jun.
Article En | MEDLINE | ID: mdl-38466497

To investigate the geometric accuracy of the radiation focal point (RFP) and cone-beam computed tomography (CBCT) over long-term periods for the ICON Leksell Gamma Knife radiosurgery system. This phantom study utilized the ICON quality assurance tool plus, and the phantom was manually set on the patient position system before the implementation of treatment for patients. The deviation of the RFP position from the unit center point (UCP) and the positions of the four ball bearings (BBs) in the CBCT from the reference position were automatically analyzed. During 544 days, a total of 269 analyses were performed on different days. The mean ± standard deviation (SD) of the deviation between measured RFP and UCP was 0.01 ± 0.03, 0.01 ± 0.03, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively. The deviations with offset values after the cobalt-60 source replacement (0.00 ± 0.03, -0.01 ± 0.01, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively) were significantly (p = 0.001) smaller than those before the replacement (0.02 ± 0.03, 0.02 ± 0.01, and -0.02 ± 0.01 mm in the X, Y, and Z directions, respectively). The overall mean ± SD of four BBs was -0.03 ± 0.03, -0.01 ± 0.05, and 0.01 ± 0.03 mm in the X, Y, and Z directions, respectively. Geometric positional accuracy was ensured to be within 0.1 mm on most days over a long-term period of more than 500 days.


Cone-Beam Computed Tomography , Phantoms, Imaging , Radiosurgery , Radiosurgery/instrumentation , Quality Assurance, Health Care , Humans , Quality Control , Time Factors
20.
Pathology ; 56(4): 540-547, 2024 Jun.
Article En | MEDLINE | ID: mdl-38413254

External quality assessment programs (EQAP) for molecular haematology generally only assess the analytical phase of laboratory testing or provide limited evaluation of post-analytical components. We incorporated comprehensive post-analytical evaluation into an existing national inter-laboratory sample exchange program for molecular haematology due to the increasing complexity of diagnostic molecular testing and interpretation. We report key findings from four years of longitudinal data using this approach. Eighteen participating laboratories enrolled in an annual reciprocal sample exchange program from 2019-2022, which covered conventional and next-generation sequencing (NGS) assays. Participants submitted results on their laboratory information system-generated reports which then underwent central review. Reports were assessed according to consensus values and relevant national and international reporting standards and guidelines. A total of 680 reports were received. Laboratories had high concordance in the analytical phase of testing, with incorrect variant detection observed in a total of six of 680 (0.9%) reports. In contrast, post-analytical concordance was much lower, with at least one discordance observed in 28.9-57.6% of all conventional reports and 33.3-100% NGS reports. The most frequent post-analytical discordances were: (1) not including key technical information on reports (total 41.9% conventional, 47.2% NGS); (2) not using standard gene and variant nomenclature (total 28.2% conventional, 25.6% NGS). NGS reports also demonstrated discrepancies in variant classification (total 20.4%) and interpretation (total 10.2%). The rate of discrepancies generally improved year-on-year. Inter-laboratory concordance for molecular haematology testing is high in the analytical phase, however opportunities exist for improvement in the post-analytical phase. Given that result interpretation is crucial for clinical decision-making and that molecular testing is a complex and evolving field, we suggest that EQAPs should comprehensively evaluate both analytical and post-analytical components of laboratory performance in order to harmonise reporting and to support the accurate interpretation of molecular haematology tests.


High-Throughput Nucleotide Sequencing , Humans , Laboratories, Clinical , Hematology/standards , Quality Assurance, Health Care , Molecular Diagnostic Techniques
...