1.
Int J Colorectal Dis ; 39(1): 85, 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38837095

BACKGROUND: Rectal cancer (RC) is a surgical challenge due to its technical complexity. The double-stapled (DS) technique, a standard for colorectal anastomosis, has been associated with notable drawbacks, including a high incidence of anastomotic leak (AL). Low anterior resection with transanal transection and single-stapled (TTSS) anastomosis has emerged to mitigate those drawbacks. METHODS: Observational study in which it described the technical aspects and results of the initial group of patients with medium-low RC undergoing elective laparoscopic total mesorectal excision (TME) and TTSS. RESULTS: Twenty-two patients were included in the series. Favourable postoperative outcomes with a median length of stay of 5 days and an AL incidence of 9.1%. Importantly, all patients achieved complete mesorectal excision with tumour-free margins, and no mortalities were reported. CONCLUSION: TTSS emerges as a promising alternative for patients with middle and lower rectal tumours, offering potential benefits in terms of morbidity reduction and oncological integrity compared with other techniques.


Anal Canal , Anastomosis, Surgical , Rectal Neoplasms , Surgical Stapling , Humans , Male , Female , Anastomosis, Surgical/methods , Middle Aged , Aged , Rectal Neoplasms/surgery , Anal Canal/surgery , Surgical Stapling/methods , Treatment Outcome , Rectum/surgery , Laparoscopy/methods , Anastomotic Leak/etiology , Anastomotic Leak/prevention & control , Adult , Aged, 80 and over
2.
Langenbecks Arch Surg ; 409(1): 184, 2024 Jun 12.
Article En | MEDLINE | ID: mdl-38862717

PURPOSE: Post-operative pancreatic fistula (POPF) remains the main complication after distal pancreatectomy (DP). The aim of this study is to evaluate the potential benefit of different durations of progressive stapler closure on POPF rate and severity after DP. METHODS: Patients who underwent DP between 2016 and 2023 were retrospectively enrolled and divided into two groups according to the duration of the stapler closure: those who underwent a progressive compression for < 10 min and those for ≥ 10 min. RESULTS: Among 155 DPs, 83 (53.5%) patients underwent pre-firing compression for < 10 min and 72 (46.5%) for ≥ 10 min. As a whole, 101 (65.1%) developed POPF. A lower incidence rate was found in case of ≥ 10 min compression (34-47.2%) compared to < 10 min compression (67- 80.7%) (p = 0.001). When only clinically relevant (CR) POPFs were considered, a prolonged pre-firing compression led to a lower rate (15-20.8%) than the < 10 min cohort (32-38.6%; p = 0.02). At the multivariate analysis, a compression time of at least 10 min was confirmed as a protective factor for both POPF (OR: 5.47, 95% CI: 2.16-13.87; p = 0.04) and CR-POPF (OR: 2.5, 95% CI: 1.19-5.45; p = 0.04) development. In case of a thick pancreatic gland, a prolonged pancreatic compression for at least 10 min was significantly associated to a lower rate of CR-POPF compared to < 10 min (p = 0.04). CONCLUSION: A prolonged pre-firing pancreatic compression for at least 10 min seems to significantly reduce the risk of CR-POPF development. Moreover, significant advantages are documented in case of a thick pancreatic gland.


Pancreatectomy , Pancreatic Fistula , Postoperative Complications , Surgical Stapling , Humans , Pancreatic Fistula/prevention & control , Pancreatic Fistula/etiology , Pancreatectomy/adverse effects , Pancreatectomy/methods , Male , Female , Retrospective Studies , Middle Aged , Aged , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Surgical Stapling/methods , Surgical Staplers , Adult , Time Factors , Pancreatic Neoplasms/surgery
4.
BMC Surg ; 24(1): 130, 2024 May 03.
Article En | MEDLINE | ID: mdl-38698365

BACKGROUND: Anastomosis configuration is an essential step in treatment to restore continuity of the gastrointestinal tract following bowel resection in patients with Crohn's disease (CD). However, the association between anastomotic type and surgical outcome remains controversial. This retrospective study aimed to compare early postoperative complications and surgical outcome between stapler and handsewn anastomosis after bowel resection in Crohn's disease. METHODS: Between 2001 and 2018, a total of 339 CD patients underwent bowel resection with anastomosis. Patient characteristics, intraoperative data, early postoperative complications, and outcomes were analyzed and compared between two groups of patients. Group 1 consisted of patients with stapler anastomosis and group 2 with handsewn anastomosis. RESULTS: No significant difference was found in the incidence of postoperative surgical complications between the stapler and handsewn anastomosis groups (25% versus 24.4%, p = 1.000). Reoperation for complications and postoperative hospital stay were similar between the two groups. CONCLUSION: Our analysis showed that there were no differences in anastomotic leak, nor postoperative complications, mortality, reoperation for operative complications, or postoperative hospital stay between the stapler anastomosis and handsewn anastomosis groups.


Anastomosis, Surgical , Crohn Disease , Postoperative Complications , Surgical Stapling , Humans , Crohn Disease/surgery , Female , Male , Anastomosis, Surgical/methods , Retrospective Studies , Adult , Surgical Stapling/methods , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Middle Aged , Suture Techniques , Reoperation/statistics & numerical data , Treatment Outcome , Length of Stay/statistics & numerical data , Anastomotic Leak/epidemiology , Anastomotic Leak/etiology , Young Adult
5.
Dis Colon Rectum ; 67(S1): S26-S35, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38710588

BACKGROUND: Available techniques for IPAA in ulcerative colitis include handsewn, double-stapled, and single-stapled anastomoses. There are controversies, indications, and different outcomes regarding these techniques. OBJECTIVE: To describe technical details, indications, and outcomes of 3 specific types of anastomoses in restorative proctocolectomy. DATA SOURCE: Systematic literature review for articles in the PubMed database according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. STUDY SELECTION: Studies describing outcomes of the 3 different types of anastomoses, during pouch surgery, in patients undergoing restorative proctocolectomy for ulcerative colitis. INTERVENTION: IPAA technique. MAIN OUTCOME MEASURES: Postoperative outcomes (anastomotic leaks, overall complication rates, and pouch function). RESULTS: Twenty-one studies were initially included: 6 studies exclusively on single-stapled IPAA, 2 exclusively on double-stapled IPAA, 6 studies comparing single-stapled to double-stapled techniques, 6 comparing double-stapled to handsewn IPAA, and 1 comprising single-stapled to handsewn IPAA. Thirty-seven studies were added according to authors' discretion as complementary evidence. Between 1990 and 2015, most studies were related to double-stapled IPAA, either only analyzing the results of this technique or comparing it with the handsewn technique. Studies published after 2015 were mostly related to transanal approaches to proctectomy for IPAA, in which a single-stapled anastomosis was introduced instead of the double-stapled anastomosis, with some studies comparing both techniques. LIMITATIONS: A low number of studies with handsewn IPAA technique and a large number of studies added at authors' discretion were the limitations of this strudy. CONCLUSIONS: Handsewn IPAA should be considered if a mucosectomy is performed for dysplasia or cancer in the low rectum or, possibly, for re-do surgery. Double-stapled IPAA has been more widely adopted for its simplicity and for the advantage of preserving the anal transition zone, having lower complications, and having adequate pouch function. The single-stapled IPAA offers a more natural design, is feasible, and is associated with reasonable outcomes compared to double-stapled anastomosis. See video from symposium.


Anastomosis, Surgical , Colitis, Ulcerative , Proctocolectomy, Restorative , Humans , Colitis, Ulcerative/surgery , Proctocolectomy, Restorative/methods , Proctocolectomy, Restorative/adverse effects , Anastomosis, Surgical/methods , Anastomosis, Surgical/adverse effects , Surgical Stapling/methods , Anastomotic Leak/etiology , Anastomotic Leak/epidemiology , Colonic Pouches/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome
6.
Surg Laparosc Endosc Percutan Tech ; 34(3): 290-294, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38736400

BACKGROUND: Despite the success of bariatric surgery in treating obesity, it can still lead to complications. The most serious and feared technical complications are bleeding and leakage from the gastric staple line. In this study, stapler line reinforcement was investigated to determine whether it affects postoperative leakage and bleeding rates and their management. MATERIALS AND METHODS: Overall, 510 patients who underwent sleeve gastrectomy were evaluated retrospectively. They were divided into 2 groups according to whether reinforcement of the staple line with running imbricating sutures was performed. RESULTS: In the reinforcement group, there were two leaks (0.7%), which were diagnosed seven and eight days after surgery. In the non-reinforcement group, there were nine leaks (4%). There was no difference between the two groups in staple line bleeding. CONCLUSIONS: This study shows that reinforcement with continuous imbricating sutures is associated with less stapler line leakage and a lower reoperation rate at the cost of increased operative time.


Anastomotic Leak , Gastrectomy , Laparoscopy , Obesity, Morbid , Surgical Stapling , Humans , Female , Male , Retrospective Studies , Laparoscopy/methods , Adult , Gastrectomy/methods , Gastrectomy/adverse effects , Surgical Stapling/methods , Anastomotic Leak/prevention & control , Anastomotic Leak/etiology , Obesity, Morbid/surgery , Middle Aged , Treatment Outcome , Suture Techniques , Reoperation , Operative Time , Postoperative Complications/prevention & control , Postoperative Complications/etiology
7.
BMJ Case Rep ; 17(5)2024 May 13.
Article En | MEDLINE | ID: mdl-38740444

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Laryngeal Neoplasms , Laryngectomy , Punctures , Trachea , Humans , Male , Laryngectomy/methods , Laryngectomy/adverse effects , Laryngeal Neoplasms/surgery , Punctures/methods , Trachea/surgery , Esophagus/surgery , Surgical Staplers , Aged , Middle Aged , Larynx/surgery , Surgical Stapling/methods , Larynx, Artificial
10.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Article En | MEDLINE | ID: mdl-38443753

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Absorbable Implants , Anastomosis, Surgical , Colectomy , Colonic Neoplasms , Ileum , Robotic Surgical Procedures , Surgical Staplers , Colectomy/methods , Colectomy/instrumentation , Humans , Anastomosis, Surgical/methods , Anastomosis, Surgical/instrumentation , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Male , Female , Middle Aged , Aged , Colonic Neoplasms/surgery , Ileum/surgery , Sutureless Surgical Procedures/methods , Sutureless Surgical Procedures/instrumentation , Operative Time , Colon/surgery , Treatment Outcome , Surgical Stapling/methods , Surgical Stapling/instrumentation , Adult , Length of Stay
11.
Vet Surg ; 53(4): 733-741, 2024 May.
Article En | MEDLINE | ID: mdl-38444078

OBJECTIVE: To compare time to construct completion and leak testing between hand-sewn and skin staple anastomoses and enterotomies in cats. STUDY DESIGN: Ex vivo, randomized study. ANIMALS: Fresh feline cadavers (n = 20). METHODS: Jejunal segments (8 cm) were harvested and tested on the same day as euthanasia. From each cadaver, one segment was randomly assigned to control (C), hand-sewn enterotomy (HSE), and skin staple enterotomy (SSE) groups, and two segments were randomly assigned to hand-sewn anastomosis (HSA) and skin staple anastomosis (SSA) groups. Construct completion time, initial leak pressure (ILP), and maximum intraluminal pressure were compared. Leakage location was reported. RESULTS: Mean time (s) ± SD was longer (p < .001) for HSA (317.0 ± 50.9) than SSA (160.8 ± 13.1) and for HSE (172.0 ± 36.5) than SSE (20.3 ± 5.0). ILP (mean ± SD) for C (600.0 mmHg ±0.0) was higher (p < .001) than all constructs. ILP (mean ± SD) for SSA (124.2 mmHg ±83.7) was not different (p = .49) than HSA (86.1 ± 51.9), but HSE (200.3 ± 114.7) was higher (p < .001) than SSE (32.2 ± 39.7). Immediate leakage from the center of enterotomy closure was observed in 7/20 SSE. CONCLUSIONS: HSA construct completion took twice as long as SSA with no difference in intraluminal pressures. Although HSE construct completion took 8x as long as SSE, HSE had higher intraluminal pressures. CLINICAL SIGNIFICANCE: In cats, SSA may be an alternative to HSA for intestinal anastomosis, but SSE is not recommended as an alternative to HSE for intestinal enterotomy closure.


Anastomosis, Surgical , Cadaver , Animals , Cats/surgery , Anastomosis, Surgical/veterinary , Anastomosis, Surgical/methods , Surgical Stapling/veterinary , Surgical Stapling/methods , Suture Techniques/veterinary , Pressure
12.
Asian J Endosc Surg ; 17(2): e13293, 2024 Apr.
Article En | MEDLINE | ID: mdl-38452773

Vascular staplers are routinely used in laparoscopic liver resection, which has become a standard procedure in advanced medical facilities. Although previous reports have outlined the benefits of staple line reinforcement (SLR), its application in Glissonean pedicle transection during hepatic resection remains poorly studied. This study investigated surgical SLR as a tool to enhance staple line strength and improve perioperative hemostasis. Here, 10 patients who underwent laparoscopic liver resection using the Tri-StapleTM2.0 Reinforced Reload were included. Patient characteristics, surgical details, and outcomes were assessed. The results demonstrated successful outcomes with no complications related to bile leakage or injuries during staple insertion. Overall, our findings suggest that SLR can be safely utilized in Glissonean pedicle transection during laparoscopic liver resections. Further studies are required to comprehensively evaluate its benefits compared with conventional surgical staplers.


Laparoscopy , Liver , Humans , Pilot Projects , Treatment Outcome , Liver/surgery , Hepatectomy/methods , Surgical Stapling/methods , Laparoscopy/methods , Sutures
16.
Dis Colon Rectum ; 67(6): 812-819, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38380816

BACKGROUND: Despite the benefits of the stapled hemorrhoidopexy in the short term, management of prolapsing hemorrhoids, the long-term results are still insufficient regarding recurrent prolapse and patient satisfaction. The current study investigates the addition of ligation anopexy to stapled hemorrhoidopexy. OBJECTIVE: Valuation of adding ligation anopexy to stapled hemorrhoidopexy in improving short-term and long-term results in the treatment of grade III and IV hemorrhoids. DATA SOURCES: Between January 2018 and January 2020, we recruited 124 patients with grade III and IV hemorrhoids at Alexandria Main University Hospital. STUDY SELECTION: Randomized controlled trial. INTERVENTIONS: One hundred twenty-four patients were blindly randomly assigned to 2 equal groups: stapled hemorrhoidopexy (group I) and stapled hemorrhoidopexy plus ligation anopexy (group II). MAIN OUTCOME MEASURES: Recurrence of hemorrhoids and patient satisfaction after a follow-up period of at least 2 years. RESULTS: The average operating time was noticeably less in the stapled hemorrhoidopexy group. Postoperative pain, analgesia requirement, hemorrhoid symptoms score, return to work, complications rate, and quality of life 1 month after surgery were similar between groups. Following a mean follow-up of 36 months (interval, 24-47), in group I, 10 patients (16%) reported recurrent external swelling and/or prolapse compared to 3 patients (5%) in group II ( p = 0.0368). Five patients in group I required redo surgery, whereas no patients required redo surgery in group II. Long-term patient satisfaction was significantly better in group II. LIMITATIONS: It was a single-center experience, so longer follow-up was needed. CONCLUSIONS: Stapled hemorrhoidopexy and stapled hemorrhoidopexy plus ligation anopexy were similar in short-term results with regard to complications rate, hemorrhoids symptoms score, return to work, and quality of life. Long-term results were significantly better with regard to recurrence of external swelling and/or prolapse and patient satisfaction after stapled hemorrhoidopexy plus ligation anopexy. See Video Abstract . TRIAL REGISTRATION NUMBER: Pan African Clinical Trials Registry identifier PACTR20180100293130. ECA PARA COMPARAR LA HEMORROIDOPEXIA CON GRAPAS MS ANOPEXIA POR LIGADURA CON LA HEMORROIDOPEXIA CON GRAPAS PARA EL TRATAMIENTO DE LA ENFERMEDAD HEMORROIDAL DE GRADO III Y IV: ANTECEDENTES:A pesar de los beneficios de la hemorroidopexia con grapas a corto plazo, el manejo de las hemorroides prolapsadas, los resultados a largo plazo aún son insuficientes en cuanto al prolapso recurrente y la satisfacción del paciente, por lo que en nuestro estudio actual agregamos anopexia por ligadura a la hemorroidopexia con grapas.OBJETIVO:Valoración de añadir anopexia por ligadura a la hemorroidopexia con grapas para mejorar los resultados a corto y largo plazo en el tratamiento de las hemorroides grado III-IV.FUENTES DE DATOS:Entre enero de 2018 y enero de 2020 reclutamos a 124 pacientes con hemorroides de grado III-IV en el hospital universitario principal de Alexandria.SELECCIÓN DEL ESTUDIO:Ensayo controlado aleatorio PACTR201801002931307.INTERVENCIÓN(S):124 pacientes fueron asignados al azar de forma ciega a dos grupos iguales, hemorroidopexia con grapas (grupo I) y hemorroidopexia con grapas más anopexia por ligadura (grupo II).PRINCIPALES MEDIDAS DE RESULTADO:Recurrencia de hemorroides y satisfacción del paciente después de un período de seguimiento de al menos dos años.RESULTADOS:El tiempo operatorio promedio fue notablemente menor en el grupo de hemorroidopexia con grapas. Mientras tanto, el dolor posoperatorio, la necesidad de analgesia, la puntuación de los síntomas de hemorroides, el regreso al trabajo, la tasa de complicaciones y la calidad de vida un mes después de la cirugía fueron similares. Después de un seguimiento medio de 36 meses (intervalo: 24-47), el Grupo I, 10 pacientes (16%) se quejaron de inflamación externa recurrente y/o prolapso en comparación con 3 pacientes (5%) en el Grupo II ( p = 0,0368) que requiere rehacer la cirugía. No fue necesaria una nueva cirugía en el grupo II; además, la satisfacción del paciente a largo plazo fue significativamente mejor en el grupo II.LIMITACIONES:Se necesita un seguimiento más prolongado y experiencia en un solo centro.CONCLUSIONES:La hemorroidopexia con grapas comparada con la hemorroidopexia con grapas más anopexia por ligadura fue similar en resultados a corto plazo en cuanto a tasa de complicaciones, puntuación de síntomas de hemorroides, regreso al trabajo y calidad de vida. Los resultados a largo plazo fueron significativamente mejores en cuanto a la recurrencia de la inflamación externa y/o el prolapso y la satisfacción del paciente después de la hemorroidopexia con grapas más anopexia por ligadura. (Traducción-Dr. Mauricio Santamaria ).


Hemorrhoids , Patient Satisfaction , Surgical Stapling , Humans , Hemorrhoids/surgery , Female , Ligation/methods , Male , Surgical Stapling/methods , Middle Aged , Adult , Hemorrhoidectomy/methods , Hemorrhoidectomy/adverse effects , Recurrence , Quality of Life , Treatment Outcome , Operative Time , Severity of Illness Index , Anal Canal/surgery , Pain, Postoperative/etiology , Pain, Postoperative/epidemiology
17.
Colorectal Dis ; 26(4): 766-771, 2024 Apr.
Article En | MEDLINE | ID: mdl-38302860

AIM: Natural orifice specimen extraction (NOSE) in left-sided colorectal surgery requires application of the circular stapler anvil to the proximal bowel without exteriorization through an additional abdominal incision. We describe an intracorporeal method to secure the stapler anvil, termed the intracorporeal antimesenteric ancillary trocar (IAAT) technique. METHOD: The ancillary trocar is attached to the stapler anvil before introduction into the abdominal cavity through the anal or vaginal orifice. The colon is incised before the trocar spike is brought out through the antimesenteric surface 3-4 cm within the cut edge. A linear stapler is used to seal the bowel end. The ancillary trocar is detached and retrieved via the NOSE conduit. Following the NOSE procedure, a side-to-end colorectal anastomosis is performed with the transanal circular stapler. RESULTS: Ten consecutive patients underwent elective left-sided colorectal resection with IAAT for NOSE (seven transanal, three transvaginal) from January to June 2023. Median age and body mass index were 66 (range 47-74) years and 24.3 (range 17.9-30.8) kg/m2 respectively. Two (20%) patients underwent sigmoid colectomy for sigmoid volvulus while eight (80%) underwent anterior resection for colorectal cancer. Median operating time, operative blood loss and postoperative length of hospital stay were 170 (range 140-240) min, 20 (range 10-40) mL and 1 (range 1-3) day respectively. There were no postoperative complications, readmissions or reoperations. Median follow-up duration was 3 (range 1-6) months. CONCLUSION: The IAAT double-stapling side-to-end anastomotic technique is safe and feasible for patients undergoing left-sided colorectal resection with NOSE, resulting in good outcomes.


Anastomosis, Surgical , Colectomy , Natural Orifice Endoscopic Surgery , Humans , Female , Middle Aged , Anastomosis, Surgical/methods , Anastomosis, Surgical/instrumentation , Aged , Male , Natural Orifice Endoscopic Surgery/methods , Natural Orifice Endoscopic Surgery/instrumentation , Colectomy/methods , Colectomy/instrumentation , Colon/surgery , Surgical Instruments , Vagina/surgery , Surgical Staplers , Surgical Stapling/methods , Surgical Stapling/instrumentation , Rectum/surgery , Operative Time
18.
Colorectal Dis ; 26(4): 772-775, 2024 Apr.
Article En | MEDLINE | ID: mdl-38372032

AIM: Total mesorectal excision with adequate free margins is the gold standard for rectal surgery. Applying a linear stapler in a narrow pelvis can be challenging and the proper distal margin difficult to assess. In selected cases the colorectal eversion technique combined with single-stapled double-purse-string anastomosis (SSDP) can be a practical solution. METHOD: Eleven patients, six men and five women, mean body mass index 27 ± 1.3 kg/m2, underwent total mesorectal excision with the colorectal eversion technique combined with modified SSDP between September 2022 and January 2023. RESULTS: The mean operative time was 190 min. The mean hospital stay was 4 days. There were no postoperative complications. The final histology showed complete mesorectal resection, circumferential resection margin negative, free distal resection margin, anastomotic doughnuts negative. At 7 ± 3 months follow-up there was no evidence of local recurrence or distant metastasis. CONCLUSION: The colorectal eversion technique combined with modified SSDP is a reproducible and safe technique in selected patients. Prospective randomized trials with large patient series are needed to confirm our preliminary results.


Anastomosis, Surgical , Colon , Operative Time , Proctectomy , Rectal Neoplasms , Rectum , Surgical Stapling , Humans , Male , Female , Anastomosis, Surgical/methods , Middle Aged , Surgical Stapling/methods , Rectum/surgery , Aged , Colon/surgery , Proctectomy/methods , Rectal Neoplasms/surgery , Treatment Outcome , Suture Techniques , Margins of Excision , Length of Stay/statistics & numerical data , Adult
20.
Obes Surg ; 34(3): 985-996, 2024 Mar.
Article En | MEDLINE | ID: mdl-38261137

Various staple line reinforcement (SLR) techniques in sleeve gastrectomy, including oversewing/suturing (OS/S), gluing, and buttressing, have emerged to mitigate postoperative complications such as bleeding and leaks. A meta-analysis of randomized controlled trials has demonstrated OS/S as an efficacious strategy for preventing postoperative complications, encompassing leaks, bleeding, and reoperations. Given that OS/S is the sole SLR technique not incurring additional costs during surgery, our study aimed to compare postoperative outcomes associated with OS/S versus alternative SLR methods. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we reviewed the literature and conducted fifteen pairwise meta-analyses of comparative studies, each evaluating an outcome between OS/S and another SLR technique. Thirteen of these analyses showed no statistically significant differences, whereas two revealed notable distinctions.


Laparoscopy , Obesity, Morbid , Humans , Surgical Stapling/methods , Obesity, Morbid/surgery , Laparoscopy/methods , Gastrectomy/methods , Postoperative Complications/prevention & control , Postoperative Complications/surgery , Treatment Outcome
...