Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Ayub Med Coll Abbottabad ; 32(3): 413-415, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32829563

RESUMEN

Patients with ischemic heart disease and left ventricular dysfunction need evaluation for myocardial viability. Two cases of myocardial perfusion imaging for viability study are discussed. Viability imaging is performed with 99mTc-Sestamibi (99mTc-MIBI), acquiring images with and without nitrate enhancement. Improvement in perfusion in nitrate enhanced images is suggestive of myocardial viability. In these cases, there was paradox effect showing reduced uptake on nitrate enhanced images than on resting images. Technical factors of equal radiotracer dose in both studies, pre-imaging time and processing were considered. Since no such contributing factor was delineated, it is postulated that phenomena can occur due to differential effects of oral glyceryl triglyceryl trinitrate (GTN) on normal and diseased vessels.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Nitroglicerina/uso terapéutico , Radiofármacos/uso terapéutico , Tecnecio Tc 99m Sestamibi/uso terapéutico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Miocardio/metabolismo , Disfunción Ventricular Izquierda/diagnóstico por imagen
2.
Clin Hemorheol Microcirc ; 75(1): 35-46, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31868660

RESUMEN

OBJECTIVE: The aim of our study was to evaluate the role of preoperative US, CEUS, and 99mTc-MIBI scanning with SPECT/CT in localizing diseased parathyroid glands in cases of refractory secondary hyperparathyroidism (SHPT). MATERIAL AND METHODS: Using pathological results as the gold standard, we compared the operative findings with the preoperative localization of each modality in 73 nodules and evaluated the accuracy, and sensitivity of each modality and combinations of the four modalities. RESULTS: The sensitivity of US, CEUS, 99mTc-MIBI and SPECT/CT was 98.59%, 94.37%, 50.70% and 78.87%, respectively. US had the highest sensitivity of the four imaging methods and the diagnostic sensitivity of US and CEUS was superior to that of 99mTc-MIBI (p < 0.001 and p < 0.001) and SPECT/CT (p = 0.001 and p = 0.012). In addition, we found that the sensitivity of the combination of US with CEUS, US with 99mTc-MIBI and/or SPECT/CT, CEUS with 99mTc-MIBI and/or SPECT/CT, US with CEUS and two other imaging modalities (99mTc-MIBI and/or SPECT/CT) was 98.59%, 100%, 95.77%, and 100%, respectively. CONCLUSIONS: The combination of US with SPECT/CT is the best choice for the comprehensive preoperative localization of glands in refractory SHPT. CEUS can elevate the accuracy of US in differential diagnosis via the interpretation of dynamic microvascular features.


Asunto(s)
Hiperparatiroidismo Secundario/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi/uso terapéutico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos , Femenino , Humanos , Hiperparatiroidismo Secundario/patología , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Estudios Retrospectivos , Tecnecio Tc 99m Sestamibi/farmacología
3.
Innovations (Phila) ; 13(6): 451-454, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30547899

RESUMEN

We report a case of 53-year-old woman with the parathyroid adenoma (PA) located in the aortopulmonary window with an aberrant right subclavian artery. Her preoperative calcium level was 11.3 mg/dL (reference range = 8.8-10.6 mg/dL). The parathyroid hormone level was significantly elevated at 127.4 pg/mL (reference range = 12-88 pg/mL) as measured on immunoradiometric assay. Dual-phase technetium-99m-labeled sestamibi parathyroid scintigraphy and fluorine-18 F-fluorocholine positron emission tomography/computed tomography revealed a mediastinal tumor measuring 3 × 5 × 6 mm located anterolateral to the aortopulmonary window. Minimally invasive removal of PA was performed through 3.5-cm reverse J-shaped partial upper sternotomy to the third intercostal space. Postoperative recovery was uneventful, and serum calcium and parathyroid hormone levels normalized within 24 hours of surgery. Our case represents the rare occurrence of a mediastinal PA associated with aberrant right subclavian artery treated with targeted minimally invasive approach using different imaging modalities including technetium-99m-sestamibi scintigraphy and fluorine-18 F-fluorocholine positron emission tomography/computed tomography, and intraoperative use of gamma probe for precise localization PA.


Asunto(s)
Adenoma , Enfermedades de la Aorta , Neoplasias de las Paratiroides , Paratiroidectomía/métodos , Adenoma/diagnóstico por imagen , Adenoma/cirugía , Aorta/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Femenino , Humanos , Hiperparatiroidismo Primario , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Neoplasias de las Paratiroides/diagnóstico por imagen , Neoplasias de las Paratiroides/cirugía , Tomografía Computarizada por Tomografía de Emisión de Positrones , Arteria Subclavia/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi/uso terapéutico
4.
Medicine (Baltimore) ; 97(40): e12578, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30290620

RESUMEN

This study aimed to evaluate the characteristics of parathyroid carcinoma and to validate the diagnostic value of Tc-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography/x-ray computed tomography (SPECT/CT) for differentiating between parathyroid carcinoma and hyperparathyroidism. Four consecutive patients with suspected primary hyperparathyroidism were enrolled in this study and underwent Tc-MIBI SPECT/CT, ultrasonography, enhanced CT, and MRI. Serum parathyroid hormone (PTH) and calcium were measured. All primary and recurrent lesions showed high focal uptake on Tc-MIBI image, whereas metastatic lymph nodes gave false negative results. The serum PTH was 165.14 ±â€Š90.26 pmol/L, which declined rapidly after surgery. One patient with a persistently high PTH (147.5 pmol/L) after surgery presented with multiple lymphadenopathy in the neck. Higher expression of chromogranin A (CgA) further confirmed parathyroid carcinoma as a rare endocrine tumor. Parathyroid carcinoma is thus usually diagnosed incidentally based on nonspecific multiorgan symptoms of hypercalcemia and hyperparathyroidism. Tc-MIBI SPECT/CT may help to localize the parathyroid carcinoma, while MRI is valuable for detecting metastasis. Serum PTH and CgA serve as circulating biomarkers in parathyroid carcinoma, and raised levels of PTH and CgA together with locoregional lymphadenopathy may indicate parathyroid carcinoma. Further studies are needed.


Asunto(s)
Neoplasias de las Paratiroides/diagnóstico por imagen , Neoplasias de las Paratiroides/patología , Radiofármacos/uso terapéutico , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tecnecio Tc 99m Sestamibi/uso terapéutico , Biomarcadores de Tumor , Calcio/sangre , Cromogranina A/sangre , Diagnóstico Diferencial , Reacciones Falso Negativas , Femenino , Humanos , Hiperparatiroidismo/diagnóstico , Metástasis Linfática/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Imagen Multimodal , Estadificación de Neoplasias , Hormona Paratiroidea/sangre , Neoplasias de las Paratiroides/diagnóstico , Radiofármacos/farmacocinética , Tecnecio Tc 99m Sestamibi/farmacocinética
5.
Isr Med Assoc J ; 19(4): 216-220, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28480673

RESUMEN

BACKGROUND: Four-dimensional parathyroid computed tomography (4DCT) is a relatively new parathyroid imaging technique that provides functional and highly detailed anatomic information about parathyroid tumors. OBJECTIVES: To assess the accuracy of 4DCT for the preoperative localization of parathyroid adenomas (PTAs) in patients with biochemically confirmed primary hyperparathyroidism (PHPT) and a history of failed surgery or unsuccessful localization using 99mTc-sestamibi scanning and ultrasonography. METHODS: Between January 2013 and January 2015, 55 patients with PHPT underwent 4DCT at Hillel Yaffe Medical Center, Hadera, Israel. An initial unenhanced scan was followed by an IV contrast injection of nonionic contrast material (120 ml of at 4 ml/s). Scanning was repeated 25, 60, and 90 seconds after the initiation of IV contrast administration. An experienced radiologist blinded to the earlier imaging results reviewed the 4DCT for the presence and location (quadrant) of the suspected PTAs. At the time of the study, 28 patients had undergone surgical exploration following 4DCT and we compared their scans with the surgical findings. RESULTS: 4DCT accurately localized 96% (27/28) of abnormal glands, all of which were hypervascular and showed characteristic rapid enhancement on 4DCT that could be distinguished from Level II lymph nodes. Surgery found hypovascular cystic PTA in one patient who produced a negative 4DCT scan. All patients had solitary PTAs. The scan at 90 seconds provided no additional information and was abandoned during the study. CONCLUSIONS: 4DCT accurately localized hypervascular parathyroid lesions and distinguished them from other tissues. A three-phase scanning protocol may suffice.


Asunto(s)
Adenoma/cirugía , Tomografía Computarizada Cuatridimensional , Glándulas Paratiroides , Neoplasias de las Paratiroides/cirugía , Paratiroidectomía , Complicaciones Posoperatorias , Adenoma/patología , Adenoma/fisiopatología , Precisión de la Medición Dimensional , Femenino , Tomografía Computarizada Cuatridimensional/métodos , Tomografía Computarizada Cuatridimensional/normas , Humanos , Hiperparatiroidismo Primario/diagnóstico , Hiperparatiroidismo Primario/etiología , Masculino , Persona de Mediana Edad , Neoplasia Residual , Evaluación de Procesos y Resultados en Atención de Salud , Glándulas Paratiroides/diagnóstico por imagen , Glándulas Paratiroides/patología , Glándulas Paratiroides/cirugía , Neoplasias de las Paratiroides/patología , Neoplasias de las Paratiroides/fisiopatología , Paratiroidectomía/efectos adversos , Paratiroidectomía/métodos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Cuidados Preoperatorios/métodos , Cuidados Preoperatorios/normas , Cintigrafía/métodos , Radiofármacos/uso terapéutico , Reoperación/métodos , Tecnecio Tc 99m Sestamibi/uso terapéutico
6.
Turk Kardiyol Dern Ars ; 44(5): 380-8, 2016 Jul.
Artículo en Turco | MEDLINE | ID: mdl-27439923

RESUMEN

OBJECTIVE: Myocardial perfusion scintigraphy (MPS) is a diagnostic tool commonly used to detect significant coronary lesion. However equivocal, false negative or positive results can be yielded. Controversial findings regarding the role of ischemia-modified albumin (IMA) in MPS evaluation persist. The aim of the present study was to examine the role of serum IMA in the assessment of MPS results. METHODS: MPS using technetium (99mTc) sestamibi and transthoracic echocardiography was performed on 62 consecutive subjects prospectively enrolled. Exercise treadmill test (ETT) with modified Bruce protocol was used to induce coronary ischemia. During MPS performance, blood samples for serum IMA were obtained at 3 times: at pre-exercise, at the peak of ETT, and 6 hours after ETT. Patients were classified into 3 groups according to MPS results (normal, equivocal, and ischemia). RESULTS: Sixty-two patients (23 normal, 20 equivocal, 19 with ischemia) were included. Pre- and peak-exercise IMA values were similar among the groups (p=0.706 and 0.904). Post-exercise IMA values of the normal and equivocal groups were similar (p=0.733), while that of the ischemia group was significantly higher than the values of either the normal (p<0.001) or equivocal groups (p<0.001). ΔIMA (the difference between post-exercise and peak-exercise IMA) of the ischemia group was significantly higher than that of either the normal (p<0.001) or equivocal groups (p<0.001). CONCLUSION: Serum IMA was found to be significantly increased in cases of ischemia on MPS. Subjects with normal and equivocal MPS had a similar pattern during the test. IMA may be used in differentiation of equivocal results from false positive results.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Imagen de Perfusión/métodos , Adulto , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Albúmina Sérica , Albúmina Sérica Humana , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adulto Joven
7.
Int J Radiat Biol ; 92(11): 698-706, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27117205

RESUMEN

PURPOSE: In addition to gamma radiation, 99mTc emits low-energy Auger electrons with path-lengths of nanometers to micrometers that cannot be utilized for diagnostic procedures; however, they have frequently been discussed for therapeutic applications. We compared radiotoxicity of three 99mTc-labeled radiopharmaceuticals with differences in the subcellular distribution. MATERIALS AND METHODS: The intracellular radionuclide uptake and subcellular distribution of [99mTc]-pertechnetate (99mTc-pertechnetate), [99mTc]Tc-hexamethyl-propylene-aminoxime (99mTc-HMPAO) and [99mTc]Tc-hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) were quantified in rat thyroid FRTL-5 cells. Radiotoxicity was compared using late phosphorylated histone H2AX (γH2AX) foci as a marker for unrepaired DNA double-strand breaks (DNA-DSB) and clonogenic cell survival. RESULTS: 99mTc-HMPAO showed a substantially higher uptake into the nucleus and the membrane/organelles than 99mTc-pertechnetate or 99mTc-MIBI. The colony-forming assay showed that 99mTc-pertechnetate and 99mTc-HMPAO caused a similar reduction in cell survival. 99mTc-MIBI is less radiotoxic in terms of the estimated nucleus dose and induced the fewest number of γH2AX foci compared with the other 99mTc-tracers, and 99mTc-HMPAO induced a fewer number of γH2AX foci than 99mTc-pertechnetate. CONCLUSIONS: Our findings reveal that clonogenic cellular survival is not solely determined by the DNA-DSB response. This finding may suggest the involvement of extra-nuclear radiosensitive targets in cell inactivation. For example, the mitochondria or the cell membrane could be affected by 99mTc-HMPAO.


Asunto(s)
Compuestos de Tecnecio/farmacocinética , Compuestos de Tecnecio/uso terapéutico , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/radioterapia , Animales , Línea Celular Tumoral , Supervivencia Celular/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Marcaje Isotópico , Radiofármacos/farmacocinética , Radiofármacos/uso terapéutico , Dosificación Radioterapéutica , Ratas , Pertecnetato de Sodio Tc 99m/farmacocinética , Pertecnetato de Sodio Tc 99m/uso terapéutico , Exametazima de Tecnecio Tc 99m/farmacocinética , Exametazima de Tecnecio Tc 99m/uso terapéutico , Tecnecio Tc 99m Sestamibi/farmacocinética , Tecnecio Tc 99m Sestamibi/uso terapéutico , Neoplasias de la Tiroides/patología
8.
Biomed Res Int ; 2014: 684383, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24800247

RESUMEN

Introduction. Early signs of response after applying wafers of carmustine-loaded polymers (gliadel) are difficult to assess with imaging because of time-related imaging changes. (99m)Tc-sestamibi (MIBI) brain single-photon emission tomography (SPET) has reportedly been used to reveal areas of cellularity distinguishing recurrent neoplasm from radionecrosis. Our aim was to explore the role of MIBI SPET in assessing response soon after gliadel application in glioblastoma multiforme (GBM). Methods. We retrospectively reviewed the charts on 28 consecutive patients with a radiological diagnosis of GBM who underwent MIBI SPET/CT before surgery (with intracavitary gliadel placement in 17 patients), soon after surgery, and at 4 months. The area of uptake was selected using a volume of interest that was then mirrored contralaterally to obtain a semiquantitative ratio. Results. After adjusting for ratio at the baseline, the effect of treatment (gliadel versus non-gliadel) was not statistically significant. Soon after surgery, however, 100% of patients treated with gliadel had a decreased ratio, as opposed to 62.5% of patients in the non-gliadel group (P = 0.0316). The difference between ratios of patients with radical versus partial resection reached statistical significance by a small margin (P = 0.0528). Conclusions. These data seem to suggest that the MIBI ratio could be a valuable tool for monitoring the effect of gliadel early after surgery.


Asunto(s)
Antineoplásicos/uso terapéutico , Carmustina/uso terapéutico , Glioblastoma/epidemiología , Glioblastoma/terapia , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Antineoplásicos/administración & dosificación , Carmustina/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Tecnecio Tc 99m Sestamibi/administración & dosificación , Resultado del Tratamiento
9.
Eur J Nucl Med Mol Imaging ; 41(6): 1224-31, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24577949

RESUMEN

PURPOSE: The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. METHODS: This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of (99m)Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. RESULTS: The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ~0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. CONCLUSION: The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy.


Asunto(s)
Arritmia Sinusal/terapia , Terapia de Resincronización Cardíaca/métodos , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca , Imagen de Perfusión Miocárdica , Anciano , Arritmia Sinusal/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos/uso terapéutico , Tecnecio Tc 99m Sestamibi/uso terapéutico , Función Ventricular Izquierda , Función Ventricular Derecha
10.
Cancer Biother Radiopharm ; 19(5): 621-6, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15650455

RESUMEN

The aim of this study was to assess the utility of 99mTc-sestamibi scintimammography (SM) in patients with suspected primary or recurrent breast cancer. Forty-four (44) breast lesions (17 with suspected recurrence of disease) in 40 patients were included into the study. In these patients, the results of conventional diagnostic methods were equivocal or inconclusive. Twenty-one (21) lesions were palpable and 23 lesions were not. Histological examinations performed during the follow-up revealed malignancy in 24 specimens. SM correctly identified 21 of them, as well as 12 true negatives. There were 8 false-positive studies; therefore, the sensitivity of SM was 87.5%, specificity was 60%, positive predictive value (PPV) was 72.4%, and the negative predictive value (NPV) was 80%. The sensitivity in palpable lesions was 100%; three (3) false negatives, 1 recurrence, and 2 cancers, all of them nonpalpable. In conclusion, SM is useful in equivocal palpable lesions for resolving diagnostic uncertainty after conventional examination, and can limit the number of surgical interventions for benign disease. However, its use in nonpalpable tumors is not recommended.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/terapia , Mamografía/métodos , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adulto , Anciano , Reacciones Falso Negativas , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cintigrafía , Recurrencia , Sensibilidad y Especificidad
11.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 25(3): 280-4, 2003 Jun.
Artículo en Chino | MEDLINE | ID: mdl-12905740

RESUMEN

OBJECTIVE: To evaluate the sensitivity and usefulness of 99mTc-sestamibi scintigraphy (SS) and neck ultrasonography (US) as preoperative localization procedures in patients with primary hyperparathyroidism (pHPT). METHODS: 160 patients with proved pHPT in Peking Union Medical College Hospital from June 1983 to June 2002 were studied. There were 107 women(66.9%) and 53 men (33.1%), with a mean age of 38.9 years (10-73 years). 100 patients were underwent SS and 148 patients were underwent US prior to surgery, and the results were compared with operative and histological findings. RESULTS: The sensitivity of SS and US in localization of the enlarged parathyroid glands was 94.0% and 85.1% respectively, and the positive predictive value of SS and US was 100% and 89.1% respectively, the overall sensitivity was 98.9% by combination of SS and US. In solitary parathyroid adenomas group (n = 145), the sensitivity of SS and US was 93.3% and 84.7% respectively; There was no significant difference (P = 0.428) in sensitivity of SS between the parathyroid glands correctly identified and undetected in classical neck location as compared with ectopic parathyroid glands, whereas significantly (P = 0.026) influenced by the US sensitivity. CONCLUSIONS: Different sensitivity exit between SS and VS in preoperative localization in patients with pHPT undergoing parathyroidectomy. The combined use of SS and US could increase the sensitivity of localization technique. Ectopic parathyroid had no influence on the sensitivity of 99mTc-MIBI scanning, but decreased the sensitivity of ultrasonography. The size of parathyroid tumors had effects on the sensitivity of ultrasonography. Otherwise, various conditions causing SS false negative were observed. Some interfere factors should be excluded when SS negative results were encountered in clinical practice.


Asunto(s)
Hiperparatiroidismo/patología , Glándulas Paratiroides/patología , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Hiperparatiroidismo/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Cuello/diagnóstico por imagen , Glándulas Paratiroides/diagnóstico por imagen , Cuidados Preoperatorios , Cintigrafía , Sensibilidad y Especificidad , Ultrasonografía
12.
Hematol Oncol ; 21(1): 17-24, 2003 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12605419

RESUMEN

Urinary cross-linked N-telopeptide of type I collagen (NTx) has been reported to be a sensitive and specific marker of bone resorption in multiple myeloma (MM). In this study, we measured the levels of NTx in 30 newly diagnosed MM patients and 25 controls. We examined its association with the overall score of skeletal involvement measured by Tc-99m-MIBI scintigraphy and other biochemical markers of bone disease (tumour necrosis factor a (TNF-a), serum calcium and creatinine). We further studied the correlation of NTx with the stage of disease (according to Durie-Salmon criteria) and bone marrow infiltration by plasma cells. High levels of NTx, bone marrow infiltration, TNF-alpha, calcium and creatinine were noted at advanced stages of disease (p < 0.05). NTx and TNF-a were found at significantly higher concentrations in patients with a high overall score (3 and 4) in Tc-99m-sestaMIBI in comparison to a low score (0, 1 and 2; p < 0.05). Positive correlations were found between NTx and TNF-a, as well as between bone infiltration and TNF-a or calcium. In conclusion, NTx is a useful marker for the monitoring of bone resorption in MM and correlates with imaging findings on Tc-99m-sestaMIBI and other biochemical markers of disease activity.


Asunto(s)
Colágeno/sangre , Colágeno/orina , Mieloma Múltiple/sangre , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/orina , Péptidos/sangre , Péptidos/orina , Radiofármacos , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Huesos/efectos de la radiación , Calcio/sangre , Colágeno Tipo I , Creatinina/sangre , Femenino , Humanos , Inmunoglobulina A/metabolismo , Inmunoglobulina G/metabolismo , Modelos Logísticos , Masculino , Persona de Mediana Edad , Cintigrafía , Cráneo/diagnóstico por imagen , Factores de Tiempo
13.
J Med Assoc Thai ; 84(3): 307-13, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11460930

RESUMEN

BACKGROUND: The detection of myocardial ischemia after percutaneous transluminal coronary angioplasty (PTCA) is important because 30-50 per cent of the patients will develop restenosis within 6 months. Symptoms of chest pain and exercise stress test (EST) have shown to be less sensitive for detection of ischemia than exercise Technetium-99m Sestamibi (Tc-99m MIBI). The purpose of this study was to compare the sensitivity and specificity of chest pain, EST and Tc-99m MIBI with coronary angiography (CAG). METHOD: Tc-99m MIBI with SPECT imaging was performed at months 1, 3 and 6 and CAG was repeated 6 months after successful PTCA. Earlier Tc-99m MIBI and CAG were performed in patients with recurrent angina pectoris or suspected restenosis. RESULTS: Forty six patients (M 29, F 17) who had undergone successful angioplasty were prospectively enrolled. Their mean age was 61 +/- 19 yrs. Eighty eight lesions (LAD63%, LCX34%, RCA19%) were performed. Lesion characteristics were type A in 9 per cent, type in B 30 per cent and type C in 61 per cent. Fifty four per cent of PTCA were performed for single vessel disease and 46 per cent for multivessel disease. The mean duration of time between PTCA and follow-up CAG was 6.1 +/- 2.7 months. We detected restenosis from CAG in 58 per cent of the cases. The Tc-99m MIBI had higher sensitivity to detect restenosis than anginal pain (85.0% vs 39.4% p < 0.005) or EST (85.0% vs 63.6% p < 0.05) when compared with CAG. The overall accuracy of Tc-99m MIBI for the detection of restenosis was 80 per cent. CONCLUSION: Tc-99m MIBI with SPECT imaging constitutes a better means than symptoms or exercise test to detect restenosis after successful coronary angioplasty.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad Coronaria/diagnóstico , Radiofármacos , Tecnecio Tc 99m Sestamibi/uso terapéutico , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
14.
J Exp Clin Cancer Res ; 20(1): 91-4, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11370836

RESUMEN

Aim of this study was to verify existing correlations between breast cancer 99mTc-sestaMIBI cells uptake and their cytological characteristics. Forty-five patients with clinically and/or mammographically suspect breast cancer were enrolled. In all patients 99mTc-sestaMIBI scintimammography was performed and malignant lesions were detected in 44 cases and benign in one case. In positive uptake (PU) lesions with diameter <1.5cm, 85.7% showed a high tumor grade (II-III degrees) while in negative uptake (NU) lesions with diameter <1.5cm, 100% showed a low tumor grade (I degrees). In PU lesions, 70% had expressed a high value of Ki 67, while 100% of the NU lesions showed normal values. In this series, tumor diameter does not play a basic role, while the correlations between uptake and the histological grade (G) and/or cellular kinetics (Ki67) seem to be more important. Further studies are needed to confirm our present results.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , División Celular , Femenino , Humanos , Persona de Mediana Edad , Índice Mitótico , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Radiografía , Cintigrafía , Radiofármacos/uso terapéutico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Q J Nucl Med ; 43(3): 195-206, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10568135

RESUMEN

With respect to further therapeutic options, whole-body 131I scintigraphy (WBS) is the most important functional imaging technique during treatment and follow-up of differentiated thyroid cancer. But in many patients, thyroid cancer tissue does not concentrate 131I and can therefore not be localized using WBS. In addition to morphologic techniques, which have a low specificity in many cases, other methods are necessary to localize tumor tissue in these patients. Besides 201Tl, which has been used initially as a tumor-seeking agent, sestamibi, tetrofosmin and 18F-DG for PET imaging have been evaluated in differentiated thyroid carcinoma. This paper summarizes the clinical impact of functional imaging with tracers besides 131I. In direct comparison, 18F-DG-PET has the highest sensitivity, which exceeds 80% in cases with negative WBS. If available, this method should be considered in all patients suffering from differentiated thyroid cancer with suspected recurrence and/or metastases, particularly in cases with elevated thyroglobulin values and negative WBS. But also 99mTc-labeled tracers can be used to detect tumor tissue with a sufficient sensitivity. In medullary thyroid cancer, which presents frequently with diagnostic difficulties, 111In-octreotide, 99mTc-(V)-DMSA, 131I/123I-mIBG, and anti-CEA can be used, in addition.


Asunto(s)
Fluorodesoxiglucosa F18 , Radiofármacos/uso terapéutico , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/radioterapia , Tomografía Computarizada de Emisión , Humanos , Metástasis de la Neoplasia , Cuidados Posoperatorios , Cuidados Preoperatorios , Recurrencia , Tecnecio Tc 99m Sestamibi/uso terapéutico , Radioisótopos de Talio , Neoplasias de la Tiroides/patología
16.
Arch. Inst. Cardiol. Méx ; 68(3): 253-5, mayo-jun 1998. ilus
Artículo en Inglés | LILACS | ID: lil-227570

RESUMEN

Se describe el caso de una mujer de 26 años de edad, con dolor torácico y origen anómalo de la arteria coronaria izquierda, la cual emerge de la arteria pulmonar. El diagnóstico se realizó por arteriografía coronaria y se complementó con Eco-Doppler y contraste miocárdico transesofágico


Asunto(s)
Humanos , Femenino , Anomalías de los Vasos Coronarios/diagnóstico , Corazón , Angiografía Coronaria , Vasos Coronarios , Ecocardiografía Transesofágica , Electrocardiografía , Arteria Pulmonar , Arteria Pulmonar , Tecnecio Tc 99m Sestamibi/uso terapéutico
18.
J Nucl Med ; 38(1): 58-62, 1997 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8998151

RESUMEN

UNLABELLED: Scintimammography using 99mTc-sestamibi and contrast-enhanced MRI were performed to determine the diagnostic accuracy of either method in the diagnostic workup of patients suspicious for breast tumors. METHODS: Fifty-six patients (42 with indeterminate mammograms) underwent preoperative prone planar scintimammography and pre- and postcontrast-enhanced MRI. Visually determined signal increase after application of Gd-DTPA was compared with visually scored sestamibi uptake, and the diagnoses of both methods were correlated with the final histopathologic results. RESULTS: Overall, sensitivity and specificity of scintimammography for diagnosing breast cancer were 88% and 83%, respectively. In the subgroup of patients with indeterminate mammograms, sensitivity was 79% and specificity was 83%. MRI readings provided a higher sensitivity (91% with respect to all patients and 89% with respect to patients with indeterminate mammograms), but a considerably lower specificity (52% in both groups) due to contrast-enhancement in different benign lesions. CONCLUSION: Due to its considerably higher specificity, scintimammography rather than MRI may be suitable to reduce the number of breast biopsies which yield benign results. Thus, this method may be suggested as the preferable tool in the diagnostic workup of patients with indeterminate mammographic findings.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/diagnóstico por imagen , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Tecnecio Tc 99m Sestamibi/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Cintigrafía
19.
Nucl Med Commun ; 17(6): 459-62, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8822742

RESUMEN

The clinical outcome of 68 patients with unexplained chest pain triaged with emergency centre (EC) SPET myocardial perfusion imaging (MPI) was assessed at 9 month follow-up. Based on clinical presentation and EC-MPI, 63% (43/68) of patients were discharged from the EC; 84% (36/43) of these patients reported no further symptoms at follow-up. There were no adverse clinical events in patients with totally normal EC-MPI.


Asunto(s)
Dolor en el Pecho/diagnóstico por imagen , Corazón/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Dolor en el Pecho/terapia , Puente de Arteria Coronaria , Urgencias Médicas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Selección de Paciente , Tecnecio Tc 99m Sestamibi/uso terapéutico , Resultado del Tratamiento , Triaje
20.
Clin Radiol ; 50(6): 404-8, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7789026

RESUMEN

Popliteal artery entrapment is difficult to diagnose even at surgery. Early diagnosis is important as the prognosis is better if detected before the onset of complications. There is no sensitive method for the evaluation of this condition. We describe three cases detected by a new technique using 99mTc methoxy isobutyl isonitrile (MIBI) with single photon emission tomography. The scintigraphic features of entrapment and the advantage of MIBI leg scintigraphy over other methods are discussed.


Asunto(s)
Arteriopatías Oclusivas/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi/uso terapéutico , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Constricción Patológica/diagnóstico por imagen , Humanos , Masculino , Músculo Esquelético/diagnóstico por imagen , Enfermedades Vasculares Periféricas/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...