Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 1396: 148-52, 2015 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-25895731

RESUMEN

This paper reports the development of a sub-minute separation method by capillary zone electrophoresis for the determination of aspartame, cyclamate, acesulfame-K and saccharin in food products and pharmaceutical samples. Separations were performed in a fused uncoated silica capillary with UV detection at 220nm. Samples and standards were injected hydrodynamically using the short-end injection procedure. The electrophoretic system was operated under constant voltage of -30kV. The background electrolyte was composed of 45mmolL(-1) 2-amino-2-(hydroxymethyl)-1,3-propanediol and 15mmolL(-1) benzoic acid at pH 8.4. The separation time for all analytes was less than 1min. Evaluation of analytical parameters of the method showed good linearity (r(2)>0.9972), limit of detection of 3.3-6.4mgL(-1), intermediate precision better than 9.75% (peak area of sample) and recovery in the range of 91-117%.


Asunto(s)
Aspartame/análisis , Ciclamatos/análisis , Análisis de los Alimentos , Preparaciones Farmacéuticas/análisis , Sacarina/análisis , Edulcorantes/análisis , Tiazinas/análisis , Electrólitos , Electroforesis Capilar/métodos
2.
J Pharm Biomed Anal ; 46(2): 219-25, 2008 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-17961953

RESUMEN

A simple and reliable reversed-phase high-perfomance liquid chromatographic method has been developed and validated for the simultaneous determination of meloxicam and pridinol mesylate in their synthetic mixtures and combined tablet formulations. Both drugs were separated on a 250 mm x 4.6mm C18 column packed with 5 microm particles. The mobile phase, optimized through an experimental design, was a 51:9:40 (v/v/v) mixture of methanol, isopropanol and 50mM potassium phosphate buffer (pH 5.9), pumped at a flow rate of 1.0 ml min(-1). UV detection was performed at 225 nm. The method was validated in the sample concentration ranges of 33.7-61.8 mg l(-1) for meloxicam and 8.8-16.8 mg l(-1) for pridinol mesylate, where it demonstrated good linearity with r=0.9989 and 0.9987 (n=15), respectively. The assay was shown to be repeatable at concentration levels of 70%, 100% and 130%, with relative standard deviation values of 1.09% and 0.82% for meloxicam and pridinol, respectively. For independent 100% level samples, the intra-day precision was 0.4% and 1.0% while the intermediate precision was 0.7% and 1.0% for the drugs. The method demonstrated to be robust, resisting to small deliberate changes in pH, flow rate and composition (organic:aqueous ratio) of the mobile phase. The LOD values were 0.22 and 0.20 mg l(-1), while the LOQ were 1.7 and 1.1 mg l(-1), for meloxicam and pridinol, respectively. The applicability of the method was demonstrated by determining the drug content of two commercial pharmaceutical formulations, where it exhibited good performance.


Asunto(s)
Antiinflamatorios no Esteroideos/análisis , Química Farmacéutica , Antagonistas Colinérgicos/análisis , Cromatografía Líquida de Alta Presión/métodos , Inhibidores de la Ciclooxigenasa/análisis , Piperidinas/análisis , Tiazinas/análisis , Tiazoles/análisis , Meloxicam , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA