Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 149
1.
Acta Ophthalmol ; 100(2): 196-202, 2022 Mar.
Article En | MEDLINE | ID: mdl-33629492

PURPOSE: Distinguishing posterior persistent fetal vasculature (PFV) from retinal detachment (RD) may be very challenging clinically and ultrasonographically, as they share common morphological features. However, it is crucial, considering their substantially distinct management and treatment. We aimed to assess the relevance of quantitative colour Doppler flow imaging to distinguish PFV from RD in children. METHODS: This retrospective bi-centre study included 66 children (30 females and 36 males, mean age: 244 ± 257 days) with a clinically suspected diagnosis of RD or posterior PFV. All children underwent systematic and standardized conventional ultrasonography and colour Doppler flow imaging under general anaesthesia with a qualitative and quantitative analysis of the retrolental tissue's vascularization. Peak systolic velocity, end-diastolic velocity and resistive index were recorded for analysis. Whenever available, surgical findings were deemed gold standard for diagnosis. A Mann-Whitney U-test was used to compare quantitative colour Doppler flow imaging data. RESULTS: Peak systolic velocity and end-diastolic velocity were significantly lower in children with PFV versus RD: 2.7 (IQR: 0.5) versus 5.1 (IQR: 2.8), p < 0.001, and 0.0 (IQR: 0.0) versus 2.0 (IQR: 1.2), p < 0.001, respectively. Resistive index was significantly higher in children with PFV versus RD: 1 (IQR: 0) versus 0.6 (IQR: 0.1), p < 0.001. Area under curves (AUCs) were of 0.94, 0.99 and 1, respectively. No differences between PFV and RD were observed on structural ultrasound or qualitative analysis of colour Doppler. CONCLUSION: Quantitative colour Doppler flow imaging has an excellent accuracy in distinguishing PFV from RD in children. It may help to improve management and treatment.


Persistent Hyperplastic Primary Vitreous/diagnostic imaging , Retinal Detachment/diagnostic imaging , Ultrasonography, Doppler, Color/standards , Blood Flow Velocity , Diagnosis, Differential , Female , Humans , Infant , Male , Persistent Hyperplastic Primary Vitreous/pathology , ROC Curve , Retinal Detachment/pathology , Retrospective Studies
2.
Clin Neurophysiol ; 135: 179-187, 2022 03.
Article En | MEDLINE | ID: mdl-34963555

OBJECTIVE: The diagnostic values of measuring median nerve (MN) stiffness and vascularity with shear wave elastography (SWE) and high-definition (HD) color were investigated in carpal tunnel syndrome (CTS). METHODS: Seventy patients (123 wrists) with CTS and thirty-five healthy volunteers (70 wrists) were enrolled. Based on nerve conduction studies (NCS), the patients were subdivided into NCS-negative, mild-to-moderate, and severe CTS groups. MN and abductor pollicis brevis (APB) SWE and MN HD color were performed on a longitudinal plane. RESULTS: The mild-to-moderate and severe CTS groups showed increased MN stiffness at the wrist and MN stiffness ratio (wrist-to forearm) compared with the control (p < 0.001). The NCS-negative CTS group showed increased MN stiffness at the wrist (p = 0.022) and MN stiffness ratio (p = 0.032) compared with the control. The severe CTS group showed increased MN stiffness at the wrist compared with the mild-to-moderate CTS group (p = 0.034). The cutoff-values in diagnosing NCS-confirmed CTS were 50.12 kPa for MN stiffness at the wrist, 1.91 for MN stiffness ratio, and grade 1 for HD color. CONCLUSIONS: SWE and HD color are good supportive tools in diagnosing and assessing severity in CTS. SIGNIFICANCE: SWE and HD color demonstrated that MN in CTS was associated with increased stiffness and hypervascularity.


Carpal Tunnel Syndrome/diagnostic imaging , Elasticity Imaging Techniques/methods , Ultrasonography, Doppler, Color/methods , Adult , Aged , Aged, 80 and over , Blood Vessels/diagnostic imaging , Carpal Tunnel Syndrome/physiopathology , Elasticity Imaging Techniques/standards , Electrodiagnosis/methods , Electrodiagnosis/standards , Female , Humans , Male , Median Nerve/blood supply , Median Nerve/physiopathology , Middle Aged , Neural Conduction , Sensitivity and Specificity , Ultrasonography, Doppler, Color/standards
3.
Int J Gynecol Cancer ; 31(12): 1535-1540, 2021 12.
Article En | MEDLINE | ID: mdl-34711665

INTRODUCTION: Although ultrasonography has been reported to have similar diagnostic accuracy to magnetic resonance imaging, it is not a standard imaging modality for cervical cancer. We aimed to summarize the ultrasonographic features of rare primary cervical cancer. METHODS: This was a retrospective study of patients with cervical cancer who were diagnosed between June 2014 and October 2019. They were divided into common-type cervical cancer (ie, cervical squamous cell carcinoma) and rare-type cervical cancer groups including adenocarcinoma, adenosquamous carcinoma, and small cell carcinoma. All patients were staged according to the tumor, nodes, and metastases criteria. RESULTS: Of the 64 patients, the diagnosis was suspected on ultrasonography in 61 (95.3%) patients and missed on ultrasonography in three patients. The tumor size was smaller in the rare-type cervical cancer group (p<0.05). Hypoechoic lesions in common-type cervical cancer and isoechoic lesions accounted for 74.4% (32/43) and 61.9% (13/21) of patients in the rare-type cervical cancer group, respectively (p<0.001). Meanwhile, 67.4% (29/43) of tumors in common-type cervical cancer were exophytic, while 66.7% (14/21) in rare-type cervical cancer were endophytic (p=0.01). Color Doppler blood signals, as compared with normal cervical tissue, were found in all patients. There was good consistency between ultrasonographic and pathologic diagnosis of rare-type cervical cancer (weighted kappa=0.87). CONCLUSIONS: Most patients with rare-type cervical cancer present with isoechoic lesions. The coincidence rate between ultrasonographic and pathologic diagnosis of rare-type cervical cancer is 87%.


Adenocarcinoma/pathology , Carcinoma, Adenosquamous/pathology , Carcinoma, Squamous Cell/pathology , Uterine Cervical Neoplasms/pathology , Adenocarcinoma/diagnostic imaging , Adult , Carcinoma, Adenosquamous/diagnostic imaging , Carcinoma, Squamous Cell/diagnostic imaging , Female , Humans , Middle Aged , Ultrasonography, Doppler, Color/methods , Ultrasonography, Doppler, Color/standards , Uterine Cervical Neoplasms/diagnostic imaging
4.
Andrology ; 9(5): 1331-1355, 2021 09.
Article En | MEDLINE | ID: mdl-34089245

BACKGROUND: Ultrasonography is the gold standard imaging method for scrotal investigation. Colour Doppler ultrasonography, contrast-enhanced ultrasonography and sonoelastography allow sonographers to assess size, echotexture, vascular features and stiffness of the scrotal organs and abnormalities. Scrotal ultrasonography has been used to investigate male reproductive health, scrotal pain, masses and trauma. However, ultrasonography thresholds/classifications used to distinguish normal and pathologic features of the scrotal organs have changed over time, and have not yet been fully standardized. OBJECTIVES: To evaluate historical trends for the standards in scrotal ultrasonography: what was, what is and what will be normal. METHODS: An extensive Medline search was performed identifying the most relevant studies in the English language from inception to date. RESULTS: We provide here (i) a brief overview of the history of ultrasonography, (ii) current indications for scrotal ultrasonography and (iii) previous and current normal values, cut-offs and classifications of the main colour-Doppler ultrasonography parameters/characteristics of the scrotal organs, as derived from recent guidelines and evidence-based studies. In addition, we report recommendations and the clinical utility of contrast-enhanced ultrasonography and sonoelastography. Finally, we discuss critical issues needing further evidence and future directions to fill in the current gaps. DISCUSSION: Several studies on scrotal ultrasonography are available. However, guidelines/recommendations dealing with specific ultrasonography applications have been published only in recent years. More recently, the European Academy of Andrology published evidence-based scrotal colour-Doppler ultrasonography reference ranges/normative parameters derived from a cohort of healthy, fertile men. In addition, a standardization of the methodology to evaluate qualitative and quantitative colour-Doppler ultrasonography parameters was reported. Other international societies reported indications, methodological standards, clinical utility and limitations of contrast-enhanced ultrasonography and sonoelastography. CONCLUSIONS: To date, colour-Doppler ultrasonography normative values for the scrotal organs are available. However, a wide international consensus on assessment and classification of several ultrasonography parameters is still lacking. An alignment of the world societies on these issues is advocated.


Elasticity Imaging Techniques/trends , Genital Diseases, Male/diagnostic imaging , Practice Guidelines as Topic , Scrotum/diagnostic imaging , Ultrasonography/trends , Elasticity Imaging Techniques/standards , History, 21st Century , Humans , Male , Reference Standards , Reference Values , Ultrasonography/methods , Ultrasonography/standards , Ultrasonography, Doppler, Color/standards , Ultrasonography, Doppler, Color/trends
6.
J Vasc Surg ; 74(5): 1438-1439, 2021 11.
Article En | MEDLINE | ID: mdl-34022379
7.
West J Emerg Med ; 21(4): 871-876, 2020 Jul 10.
Article En | MEDLINE | ID: mdl-32726258

INTRODUCTION: Grayscale ultrasound (US) imaging has been used as an adjunct for confirming endotracheal tube (ETT) placement in recent years. The addition of color Doppler imaging (CDI) has been proposed to improve identification but has not been well studied. The aim of this study was to assess whether CDI improves correct localization of ETT placement. METHODS: A convenience sample of emergency and critical care physicians at various levels of training and experience participated in an online assessment. Participants viewed US video clips of patients, which included either tracheal or esophageal intubations captured in grayscale or with CDI; there were five videos of each for a total of 20 videos. Participants were asked to watch each clip and then assess the location of the ETT. RESULTS: Thirty-eight subjects participated in the online assessment. Levels of training included medical students (13%), emergency medicine (EM) residents (50%), EM attendings (32%), and critical care attendings (5%). The odds ratio of properly assessing tracheal placement using color relative to a grayscale imaging technique was 1.5 (p = 0.21). Regarding the correct assessment of esophageal placement, CDI had 1.4 times the odds of being correctly assessed relative to grayscale (p = 0.26). The relationship between training level and correct assessments was not significant for either tracheal or esophageal placements. CONCLUSION: In this pilot study we found no significant improvement in correct identification of ETT placement using color Doppler compared to grayscale ultrasound; however, there was a trend toward improvement that might be better elucidated in a larger study.


Equipment Safety/methods , Intubation, Intratracheal , Ultrasonography, Doppler, Color , Emergency Service, Hospital , Esophagus/diagnostic imaging , Humans , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Intubation, Intratracheal/standards , Pilot Projects , Quality Improvement/organization & administration , Sensitivity and Specificity , Trachea/diagnostic imaging , Ultrasonography, Doppler, Color/methods , Ultrasonography, Doppler, Color/standards
8.
Int J Cardiovasc Imaging ; 36(10): 1931-1939, 2020 Oct.
Article En | MEDLINE | ID: mdl-32506285

Pulse wave velocity (PWV) measured by ultrafast ultrasound imaging can early evaluate arteriosclerosis. The study aimed to establish normal reference range for ufPWV in healthy adults and explore its influencing factors, and evaluate the ufPWV changes on coronary slow flow (CSF). ufPWV at the beginning and end of systole (ufPWV-BS and ufPWV-ES, respectively) was measured in healthy adults (201 cases). CSF was diagnosed based on thrombolysis in myocardial infarction (TIMI) frame count during coronary angiography. ufPWV-BS and ufPWV-ES were compared between CSF (50 cases) and control groups (50 healthy age-, body mass index-, and blood pressure-matched adults). In healthy adults, average ufPWV-BS and ufPWV-ES was 5.36 ± 1.27 m/s and 6.99 ± 1.93 m/s, respectively. ufPWV-BS and ufPWV-ES positively correlated with age, body mass index, and blood pressure. ufPWV-BS and ufPWV-ES in the CSF group were higher than in the control group (ufPWV-BS, 6.05 ± 1.07 vs. 5.26 ± 0.89 m/s, P < 0.001; ufPWV-ES, 9.07 ± 1.84 vs. 6.84 ± 1.08 m/s, P < 0.001). Receiver operating characteristic curves showed that ufPWV-ES was more sensitive than ufPWV-BS. The normal reference range of ufPWV for healthy adults was established. Age, body mass index, and blood pressure were the main influencing factors. ufPWV was increased in the patients with CSF. The findings indicated that, in addition to reflecting atherosclerosis, ufPWV might also provide a basis for the noninvasive evaluation of microvascular impairment in the patients with CSF.


Cardiovascular Diseases/diagnostic imaging , Carotid Arteries/diagnostic imaging , Carotid Intima-Media Thickness/standards , Coronary Circulation , Pulse Wave Analysis/standards , Ultrasonography, Doppler, Color/standards , Vascular Stiffness , Adult , Age Factors , Aged , Blood Flow Velocity , Cardiovascular Diseases/physiopathology , Carotid Arteries/physiopathology , Case-Control Studies , Coronary Angiography , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reference Values , Reproducibility of Results , Sex Factors , Time Factors , Young Adult
9.
Fetal Diagn Ther ; 47(2): 129-137, 2020.
Article En | MEDLINE | ID: mdl-31280268

OBJECTIVE: Mean uterine artery pulsatility index (meanUAPI) is commonly measured at 11-13+6 weeks to predict adverse pregnancy outcomes including hypertensive disorders and small-for-gestational age. The aims of this study were to establish a population-specific reference range for meanUAPI at <11 weeks, to determine if an abnormal meanUAPI at <11 weeks was associated with adverse pregnancy outcome, and to assess changes in meanUAPI between <11 weeks and 11-13+6 weeks. METHODS: A prospective cohort was examined at <11 weeks and at 11-13+6 weeks to develop reference ranges for meanUAPI. Based on these regression models, meanUAPI Z-scores were compared between outcome groups using a two-sample t test. Longitudinal changes in the meanUAPI between <11 and 11-13+6 weeks were assessed by two-way mixed ANOVA. RESULTS: Prior to 11 weeks, there was no significant difference in meanUAPI between normal (n = 622) and adverse (n = 80) outcomes (mean [95% CI]: 2.62 [2.57-2.67] and 2.67 [2.50-2.84], respectively; p = 0.807). At 11-13+6 weeks, meanUAPI was significantly higher in the adverse (n = 66) compared with the normal (n = 535) outcome group (mean [95% CI]: 1.87 [1.70-2.03] and 1.67 [1.63-1.72], respectively; p = 0.040). There was a statistically significant decrease (p < 0.0001) in meanUAPI between the two time points. CONCLUSION: MeanUAPI measured at <11 weeks' gestation does not appear to be a useful marker for the prediction of placental-related adverse pregnancy outcomes, supporting an argument for the prediction of risk at 11-13+6 weeks' gestation.


Placental Circulation , Pulsatile Flow , Ultrasonography, Doppler, Color , Ultrasonography, Prenatal , Uterine Artery/diagnostic imaging , Adolescent , Adult , Female , Fetal Growth Retardation/diagnostic imaging , Fetal Growth Retardation/physiopathology , Gestational Age , Humans , Infant, Small for Gestational Age , Pre-Eclampsia/diagnostic imaging , Pre-Eclampsia/physiopathology , Predictive Value of Tests , Pregnancy , Pregnancy Outcome , Prospective Studies , Reference Values , Ultrasonography, Doppler, Color/standards , Ultrasonography, Prenatal/standards , Uterine Artery/physiopathology , Young Adult
10.
Neurocrit Care ; 32(2): 502-511, 2020 04.
Article En | MEDLINE | ID: mdl-31264072

BACKGROUND: To report a consensus on the different competency levels for the elaboration of skill recommendations in performing brain ultrasonography within the neurocritical care setting. METHODS: Four brain ultrasound experts, supported by a methodologist, performed a preselection of indicators and skills based on the current literature and clinical expertise. An international panel of experts was recruited and subjected to web-based questionnaires according to a Delphi method presented in three separate rounds. A pre-defined threshold of agreement was established on expert subjective opinions, > 84% of votes was set to support a strong recommendation and > 68% for a weak recommendation. Below these thresholds, no recommendation reached. RESULTS: We defined four different skill levels (basic, basic-plus, pre-advanced, advanced). Twenty-five experts participated to the full process. After four rounds of questions, two items received a strong recommendation in the basic skill category, three in the advanced, twelve in the basic-plus, and seven in the pre-advanced. Two items in the pre-advanced category received a weak recommendation and three could not be collocated and were excluded from the list. CONCLUSIONS: Results from this consensus permitted stratification of the different ultrasound examination skills in four levels with progressively increasing competences. This consensus can be useful as a guide for beginners in brain ultrasonography and for the development of specific training programs within this field.


Clinical Competence , Critical Care/standards , Ultrasonography, Doppler, Color/standards , Ultrasonography, Doppler, Transcranial/standards , Delphi Technique , Echoencephalography/standards , Expert Testimony , Humans
11.
Rev Med Interne ; 41(2): 106-110, 2020 Feb.
Article Fr | MEDLINE | ID: mdl-31732197

Giant cell arteritis is the most common primary vasculitis of large-vessel occurring in subjects over 50 years of age. Many imaging techniques has been evaluated to improve the diagnosis of giant cell arteritis. Among these imaging techniques, ultrasound has shown good performances to detect inflammatory involvement of the temporal arteries as well as branches of the aorta. Several publications and recent EULAR recommendations have emhasized the place of this tool in the diagnosis of giant cell arteritis.


Giant Cell Arteritis/diagnosis , Ultrasonography, Doppler, Color/methods , Diagnostic Imaging/history , Diagnostic Imaging/methods , Diagnostic Imaging/standards , Giant Cell Arteritis/diagnostic imaging , History, 20th Century , History, 21st Century , Humans , Practice Guidelines as Topic , Predictive Value of Tests , Ultrasonography, Doppler, Color/history , Ultrasonography, Doppler, Color/standards
12.
Ultrasound Obstet Gynecol ; 53(2): 245-250, 2019 02.
Article En | MEDLINE | ID: mdl-29917286

OBJECTIVE: To assess the quality of mean uterine artery (UtA) pulsatility index (PI) measurement in a first-trimester pre-eclampsia screening program. METHODS: Consecutive women with a singleton pregnancy attending first-trimester screening for fetal chromosomal abnormalities also had combined screening for pre-eclampsia based on the Fetal Medicine Foundation (FMF) algorithm, at a large practice in Sydney, Australia, from May 2014 to February 2017. Distributions of mean UtA-PI multiples of the median (MoM) on a logarithmic scale were plotted in relation to the normal median with 95% CI for each operator and for each month. Central tendency and dispersion and cumulative sum charts were produced. Mean UtA-PI MoM values between 0.95 and 1.05 were considered ideal and those between 0.90 and 1.10 were considered acceptable. The screen-positive rates for preterm pre-eclampsia in different groups of sonographers according to their mean log10 UtA-PI MoM were calculated and compared using the chi-square test. RESULTS: A total of 21 010 women attended for first-trimester ultrasound and had screening for pre-eclampsia. The overall median UtA-PI MoM was 1.042 (interquartile range (IQR), 0.85-1.26). Of 46 sonographers, 42 (91.3%) performed more than 50 examinations and, of those, 41 (97.6%) measured UtA-PI within the acceptable range. Sonographers measuring UtA-PI MoM on average below 0.95 and those measuring it above 1.05 had, respectively, lower and higher screen-positive rates when compared with those with measurements within the 0.95-1.05 UtA-PI MoM interval (7.2% and 13.2% vs 11.2%, respectively, P < 0.001). CONCLUSION: UtA Doppler is measured well among trained operators when following an established protocol. While slight variations are expected, systematic error in this measurement impacts on the screen-positive rate. Therefore, a quality control process should be in place and retraining of staff may be required. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Pre-Eclampsia/diagnostic imaging , Pulsatile Flow , Ultrasonography, Doppler, Color/standards , Uterine Artery/diagnostic imaging , Adult , Diagnostic Errors/prevention & control , Female , Humans , Mass Screening/standards , Pre-Eclampsia/prevention & control , Pregnancy , Pregnancy Trimester, First , Prospective Studies , Ultrasonography, Prenatal/standards , Uterine Artery/physiopathology
13.
Ultrasound Obstet Gynecol ; 51(6): 818-828, 2018 06.
Article En | MEDLINE | ID: mdl-28944985

OBJECTIVE: To describe the sonographic features of endometrial cancer in relation to tumor stage, grade and histological type, using the International Endometrial Tumor Analysis (IETA) terminology. METHODS: This was a prospective multicenter study of 1714 women with biopsy-confirmed endometrial cancer undergoing standardized transvaginal grayscale and Doppler ultrasound examination according to the IETA study protocol, by experienced ultrasound examiners using high-end ultrasound equipment. Clinical and sonographic data were entered into a web-based database. We assessed how strongly sonographic characteristics, according to IETA, were associated with outcome at hysterectomy, i.e. tumor stage, grade and histological type, using univariable logistic regression and the c-statistic. RESULTS: In total, 1538 women were included in the final analysis. Median age was 65 (range, 27-98) years, median body mass index was 28.4 (range 16-67) kg/m2 , 1377 (89.5%) women were postmenopausal and 1296 (84.3%) reported abnormal vaginal bleeding. Grayscale and color Doppler features varied according to grade and stage of tumor. High-risk tumors, compared with low-risk tumors, were less likely to have regular endometrial-myometrial junction (difference of -23%; 95% CI, -27 to -18%), were larger (mean endometrial thickness; difference of +9%; 95% CI, +8 to +11%), and were more likely to have non-uniform echogenicity (difference of +7%; 95% CI, +1 to +13%), a multiple, multifocal vessel pattern (difference of +21%; 95% CI, +16 to +26%) and a moderate or high color score (difference of +22%; 95% CI, +18 to +27%). CONCLUSION: Grayscale and color Doppler sonographic features are associated with grade and stage of tumor, and differ between high- and low-risk endometrial cancer. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Endometrial Neoplasms/diagnostic imaging , Neoplasm Grading , Ultrasonography, Doppler, Color/standards , Adult , Aged , Aged, 80 and over , Consensus Development Conferences as Topic , Cross-Sectional Studies , Endometrial Neoplasms/classification , Endometrial Neoplasms/pathology , Female , Humans , Middle Aged , Prospective Studies , Reproducibility of Results , Terminology as Topic
14.
Am J Emerg Med ; 36(7): 1166-1169, 2018 Jul.
Article En | MEDLINE | ID: mdl-29223688

INTRODUCTION: Intubation is a frequently performed procedure in emergency medicine that is associated with significant morbidity and mortality when unrecognized esophageal intubation occurs. However, it may be difficult to visualize the endotracheal tube (ETT) in some patients. This study assessed whether the addition of color Doppler was able to improve the ability to visualize the ETT location. METHODS: This study was performed in a cadaver lab using three different cadavers chosen to represent varying neck circumference. Cadavers were randomized to tracheal or esophageal intubation. Blinded sonographers then assessed the location of the ETT using either grayscale or color Doppler imaging. Accuracy of sonographer identification of ETT location, time to identification, and operator confidence were assessed. RESULTS: One hundred and fifty intubations were performed and each was assessed by both standard and color Doppler techniques. There were 78 tracheal intubations and 72 esophageal intubations. The standard technique was 99.3% (95% CI 96.3 to 99.9%) accurate. The color flow technique was also 99.3% (95% CI 96.3 to 99.9%) accurate. The mean operator time to identification was 3.24s (95% CI 2.97 to 3.51s) in the standard approach and 5.75s (95% CI 5.16 to 6.33s) in the color flow technique. The mean operator confidence was 4.99/5.00 (95% CI 4.98 to 5.00) in the standard approach and 4.94/5.00 (95% CI 4.90 to 4.98) in the color flow technique. CONCLUSION: When added to standard ultrasound imaging, color flow did not improve accuracy or operator confidence for identifying ETT location and resulted in a longer examination time.


Intubation, Intratracheal , Cadaver , Clinical Competence/standards , Esophagus/diagnostic imaging , Humans , Intubation , Neck/anatomy & histology , Neck/diagnostic imaging , Observer Variation , Sensitivity and Specificity , Single-Blind Method , Ultrasonography/standards , Ultrasonography, Doppler, Color/standards
15.
Clin Neurol Neurosurg ; 162: 101-107, 2017 Nov.
Article En | MEDLINE | ID: mdl-29017105

OBJECTIVE: The incidence of chronic Subdural hematoma (cSDH) is increasing and its rate of recurrence varies from 5 to 33%. A postoperative brain midline-shift (MLS) on computed tomography (CT) equal or larger than 5mm is a risk factor for recurrence. Transcranial color-coded duplex sonography (TCCDS) is a noninvasive bedside reproducible technique useful to detect MLS. The aim of our study was to compare in patients affected by cSDH, the values of MLS obtained pre- and post-operatively by TCCDS and brain CT. PATIENTS AND METHODS: 32 patients affected by cSDH entered the study between July 2016 and January 2017. MLS values obtained by TCCDS and brain CT were compared using Bland-Altman plot and linear regression analysis. Using the same techniques we also explored if the agreement between the two imaging modes was comparable in pre- and post-operative data pairs. RESULTS: 64 data pairs of MLS values obtained by TCCDS and CT were analysed. Bland-Altman diagrams did not show any systematic bias of the data and linear regression indicated a significant correlation between the two measures both before and after hematoma evacuation. CONCLUSION: In patients affected by cSDH, MLS values obtained before and after surgery by TCCDS are comparable to those obtained by CT; TCCDS might be considered an alternative to CT scan in the management of patients after cSDH evacuation. We suggest that close clinical bedside examination and TCCDS might be appropriate for the post-operative management of cSDH, reserving CT scan only to patients with overt clinical deterioration and/or increasing MLS.


Drainage/adverse effects , Hematoma, Subdural, Chronic/diagnostic imaging , Hematoma, Subdural, Chronic/surgery , Neurosurgical Procedures/adverse effects , Point-of-Care Testing , Postoperative Care/methods , Postoperative Complications/diagnostic imaging , Tomography, X-Ray Computed/methods , Ultrasonography, Doppler, Color/methods , Ultrasonography, Doppler, Transcranial/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Point-of-Care Testing/standards , Postoperative Care/standards , Prospective Studies , Recurrence , Tomography, X-Ray Computed/standards , Ultrasonography, Doppler, Color/standards , Ultrasonography, Doppler, Transcranial/standards
16.
J Orthop Surg Res ; 12(1): 152, 2017 Oct 17.
Article En | MEDLINE | ID: mdl-29041980

BACKGROUND: As an irreversible disease, a treatment delay can negatively affect treatment response in rheumatoid arthritis (RA). Ultrasound and MRI have played an important role in assessing disease progression and response to treatment in RA for many years. The present study was designed to compare the diagnostic efficacy of ultrasound grading and MRI in early RA. METHODS: In this retrospective study, 62 early RA patients within 12 months of symptom onset were included. DAS28, rheumatoid factor (RF), CRP, ESR, and anti-cyclic citrullinated peptide antibody (CCP) of the patients were measured. Bilateral hand joints and wrists were examined by ultrasonography (US) and MRI; diagnosis outcome was compared. Relationship between DAS28 scores, laboratory parameters, and ultrasound findings were analyzed. RESULTS: Ultrasound and MRI had an equivalent diagnosis value in synovitis, joint effusion, and tenosynovitis. The detection rate of synovitis, arthroedema, and tenosynovitis on ultrasound and MRI was very close (P > 0.05). The detection rate of bone erosion was lower in ultrasonography than that in MRI (P < 0.05). There were significant differences between power Doppler ultrasonography (PDUS) and gray-scale ultrasonography (GSUS) in the diagnosis of synovitis (χ 2 = 3.92, P < 0.05); the sensitivity of GSUS was better than that of PDUS (P < 0.05). PDUS was positively correlated with DAS28, ESR, CRP, and CCP (P < 0.01), but not correlated with RF and disease duration (P > 0.05). GSUS was positively correlated with RF and CRP (P < 0.01), but not correlated with DAS28, CCP, ESR, and disease duration (P > 0.05). Bone erosion was positively correlated with disease duration, CCP, and RF (P < 0.01) and was not correlated with DAS28, ESR, and CRP (P > 0.05). CONCLUSION: Ultrasonography has a high reliability in the diagnosis of early RA in synovitis, joint effusion, tenosynovitis, and bone erosion. Ultrasonography and clinical and laboratory parameters had a great correlativity. Both ultrasound and MRI are effective techniques. In view of the advantages of low cost and convenience, ultrasound may be a better choice during early RA diagnosis.


Arthritis, Rheumatoid/diagnostic imaging , Magnetic Resonance Imaging/standards , Severity of Illness Index , Ultrasonography, Doppler, Color/standards , Adult , Arthritis, Rheumatoid/therapy , Early Diagnosis , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Treatment Outcome
17.
Curr Neurovasc Res ; 14(4): 316-322, 2017.
Article En | MEDLINE | ID: mdl-28982329

BACKGROUND: High prevalence of valve absence was found in the internal jugular vein (IJV) of healthy volunteers by means of M-mode high-resolution Echo Colour Doppler (ECD). However, the prevalence of valve in neurovascular disorders linked to Chronic Cerebrospinal Venous Insufficiency (CCSVI) is still unknown. METHODS: A cohort of 83 Healthy Controls (HC), 71 Multiple Sclerosis (MS), 99 Inner Ear Disorders (IED) underwent ECD investigation of the IJV valve, including M-mode evaluation and related hemodynamics. The primary outcome measure was characterization of valve presence, morphology and motility, whereas the secondary outcome was the rate of flow alteration. RESULTS: Bilateral valve presence was found in 38% of HC, 58% of MS and 25% of IED, whereas, bilateral valve absence was recorded in 16% of HC, 10% of MS and 31% of IED (p<0.003). Bicuspid morphology was more prevalent in HC 56%, while monocusp was more prevalent in patients: 75% MS and 57% IED (p<0.0001). The main finding was the presence of mobile valve leaflets in 98% of HC, contrarily fixed valve leaflets were recorded in 82% of MS and in 41% of IED, p< 0.0001. Finally, by stratifying the entire cohort according to the presence of mobile and not mobile valve leaflets, normal monodirectional and phasic flow were commonly found in the mobile leaflets subgroup, p<0.0001. CONCLUSION: In patients with miscellaneous neurological disorders, a significant higher rate of defective valves was found with respect to HC. The latter condition is strongly associated to brain outflow abnormalities described in CCSVI condition.


Jugular Veins/diagnostic imaging , Labyrinth Diseases/diagnostic imaging , Multiple Sclerosis/diagnostic imaging , Ultrasonography, Doppler, Color/methods , Venous Insufficiency/diagnostic imaging , Venous Valves/diagnostic imaging , Adolescent , Adult , Aged , Cohort Studies , Female , Humans , Jugular Veins/abnormalities , Labyrinth Diseases/epidemiology , Male , Middle Aged , Multiple Sclerosis/epidemiology , Single-Blind Method , Ultrasonography, Doppler, Color/standards , Venous Insufficiency/epidemiology , Venous Valves/abnormalities , Young Adult
18.
J Ultrasound Med ; 36(7): 1347-1354, 2017 Jul.
Article En | MEDLINE | ID: mdl-28449311

OBJECTIVES: To estimate intraobserver and interobserver reproducibility for assigning an International Endometrial Tumor Analysis (IETA) group color score for endometrial vascularization on color Doppler imaging. METHODS: Sixty-eight endometrial 3-dimensional volumes from endometrial color Doppler assessments of women with different endometrial disorders were evaluated by 8 different examiners (4 skilled examiners and 4 obstetric and gynecologic trainees). One skilled examiner who did not participate in the assessments selected the 68 volumes from a database to select a balanced number of each IETA score. Each examiner evaluated the 68 endometrial volumes to assign the IETA color score (1, absence of vascularization; 2, low vascularization; 3, moderate vascularization; or 4, abundant vascularization) using tomographic ultrasound imaging. The analysis was repeated 4 weeks later, and interobserver and intraobserver reproducibility was analyzed by calculating the weighted κ index. The second of the measurements made by each observer was used to estimate interobserver reproducibility. RESULTS: The intraobserver reproducibility was very good for all examiners, with a weighted κ index ranging from 0.84 to 0.91. The interobserver reproducibility was good or very good for all estimated comparisons, with a weighted κ index ranging from 0.77 to 0.96, regardless of experience level. CONCLUSIONS: The reproducibility of assigning the IETA color score for assessing endometrial vascularization using 3-dimensional volumes is good or very good regardless of the experience of the examiner.


Blood Flow Velocity/physiology , Endometrium/diagnostic imaging , Endometrium/physiology , Image Interpretation, Computer-Assisted/standards , Imaging, Three-Dimensional/standards , Ultrasonography, Doppler, Color/standards , Adult , Female , Humans , Internationality , Observer Variation , Organ Size , Practice Guidelines as Topic , Reproducibility of Results , Sensitivity and Specificity , Young Adult
19.
J Cardiothorac Vasc Anesth ; 31(3): 973-979, 2017 Jun.
Article En | MEDLINE | ID: mdl-28366714

OBJECTIVES: To assess the feasibility and reliability of transthoracic echocardiography to measure inferior vena cava (IVC) diameter variation using a transhepatic view. DESIGN: Prospective cohort study. SETTING: Single-center hospital. PATIENTS: Forty consecutive patients undergoing elective cardiac surgery. INTERVENTIONS: Bedside transthoracic echocardiography. MEASUREMENTS AND MAIN RESULTS: Correlation between the two views was measured using Pearson R, while agreement was measured using the intraclass correlation coefficient (ICC). In a nested sub-study of 16 randomly selected participants, all images were re-rated by the same rater, who was blinded to the original measurement results, and by a second blinded operator. Correlation between the subcostal and transhepatic views was moderate when assessing maximum (R 0.46; 95% confidence interval [CI], 0.18-0.68), and minimum (R 0.55; CI, 0.29-0.74) IVC diameter. Correlation when measuring IVC diameter variation was higher (R 0.70; CI, 0.49-0.83). Agreement between the two views for IVC diameter variation measurement was substantial (ICC 0.73; CI, 0.49-0.85). Intra-rater reliability was excellent (ICC 0.95-0.99). CONCLUSIONS: Agreement between subcostal and transhepatic views was substantial for the assessment of IVC diameter variation; however, the magnitude of agreement was less than anticipated. Further research is needed to determine if the transhepatic view can be used reliably in the assessment of fluid responsiveness.


Echocardiography/methods , Hepatic Veins/diagnostic imaging , Ultrasonography, Doppler, Color/methods , Vena Cava, Inferior/diagnostic imaging , Aged , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/standards , Cohort Studies , Echocardiography/standards , Female , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Random Allocation , Single-Blind Method , Ultrasonography, Doppler, Color/standards
20.
Vascular ; 25(6): 612-617, 2017 Dec.
Article En | MEDLINE | ID: mdl-28423999

Introduction To investigate the diagnostic accuracy of an automated toe blood pressure device for detecting peripheral arterial disease in older people. Methods Ninety participants underwent toe and brachial blood pressure measurements and colour duplex ultrasonography of the right lower limb. Peripheral arterial disease was diagnosed if > 50% arterial obstruction was identified in any lower limb vessel using colour duplex ultrasonography. A receiver operating characteristic curve was analysed and the sensitivity and specificity of commonly used toe brachial index and toe blood pressure values were determined. Results The optimum toe brachial index threshold value for diagnosing peripheral arterial disease was 0.72 (sensitivity 76.2%, specificity 75%). The area under the curve was 0.829 (95% CI 0.743 to 0.915, p < 0.0001) suggesting fair diagnostic accuracy. A toe blood pressure of 70 mmHg was found to have excellent specificity (97.92%) for detecting PAD but poor sensitivity (42.86%). Conclusions The accuracy of automated toe blood pressure and TBI measurements was determined to be good when using colour duplex ultrasound as the reference standard for the non-invasive diagnosis of peripheral arterial disease. Results should be interpreted in the context of all clinical signs and symptoms.


Ankle Brachial Index/instrumentation , Hemodynamics , Peripheral Arterial Disease/diagnosis , Ultrasonography, Doppler, Color , Age Factors , Aged , Aged, 80 and over , Ankle Brachial Index/standards , Area Under Curve , Automation , Female , Humans , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Predictive Value of Tests , ROC Curve , Reference Standards , Reproducibility of Results , Ultrasonography, Doppler, Color/standards
...