Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Obes Surg ; 32(2): 273-283, 2022 02.
Article in English | MEDLINE | ID: mdl-34811645

ABSTRACT

INTRODUCTION: Argon plasma coagulation (APC) alone is effective and safe at treating weight regain following Roux-en-Y gastric bypass (RYGB). However, technical details of the treatment vary widely among studies. Therefore, we aimed to create good clinical practice guidelines through a modified Delphi consensus, including experts from the collaborative Bariatric Endoscopy Brazilian group. METHODS: Forty-one locally renowned experts were invited to the consensus by email. Experiences of > 150 APC-treated cases or authorship of relevant articles were the eligibility criteria. An initial questionnaire with short-answer questions was distributed to the experts. The organizing committee converted the responses into statements for an online 2-day voting webinar. Consensus was defined as more than 67% of positive answers. Three consecutive voting rounds were planned with discussion and statement refinements between rounds. RESULTS: Thirty-seven experts fulfilled eligibility criteria and attended the live webinar voting. The total number of patients treated by the panel was 12,349. By the third round, all 79 statements reached consensus. The recommendations include the definition of dilated gastrojejunal anastomosis as ≥ 15 mm, minimum regain of 20% of the lost weight to indicate the APC therapy, 6 to 8 weeks as the ideal interval between ablation sessions, and stopping treatment when the stoma reaches < 12 mm of breadth. CONCLUSIONS: This consensus provides several recommendations based on a highly experienced panel of endoscopists. Although it covers most aspects of the treatment, the level of evidence is low for the majority of the statements. Therefore, bariatric endoscopists should be constantly attentive to new evidence on APC treatment.


Subject(s)
Gastric Bypass , Obesity, Morbid , Argon Plasma Coagulation/adverse effects , Brazil , Consensus , Delphi Technique , Dilatation, Pathologic/surgery , Endoscopy, Gastrointestinal , Gastric Bypass/adverse effects , Humans , Obesity, Morbid/surgery , Reoperation , Treatment Outcome , Weight Gain
2.
Obes Surg ; 31(1): 70-78, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32815105

ABSTRACT

PURPOSE: Bariatric endoscopy is a less invasive approach for obesity management, with better efficacy than pharmacological treatment and low morbidity. Endoscopic sleeve gastroplasty (ESG) is the remodeling of the stomach using a suturing device showing technical feasibility, safety, and sustained weight loss. With growing numbers of procedures worldwide, there is a need to standardize the procedure. MATERIALS AND METHODS: A consensus meeting was held in São Caetano do Sul-SP, Brazil, in June 2019, bringing together 47 Brazilian endoscopists with experience in ESG from all regions of the country. Topics on indications and contraindications of the procedure, pre-procedure evaluation and multidisciplinary follow-up, technique and post-procedure follow-up, and training requirements were discussed. An electronic voting was carried, and a consensus was defined as ≥ 70% agreement. RESULTS: The panel's experience consisted of 1828 procedures, with a mean percentage total body weight loss (TBWL) of 18.2% in 1 year. Adverse events happened in 0.8% of the cases, the most common being hematemesis. The selected experts discussed and reached a consensus on several questions concerning patient selection, contraindications for the procedure, technical details such as patient preparation, procedure technique, and patient follow-up. CONCLUSIONS: This consensus establishes practical guidelines for performance of ESG. The experience of 1828 procedures shows the expertise of the selected specialists participating in this consensus statement. The group's experience has a satisfactory weight loss with low adverse events rate. The main points discussed in this paper may serve as a guide for endoscopists performing ESG. Practical recommendations and technique standardization are described.


Subject(s)
Gastroplasty , Obesity, Morbid , Brazil , Consensus , Endoscopy , Humans , Obesity/surgery , Obesity, Morbid/surgery , Treatment Outcome
3.
Surg Obes Relat Dis ; 15(8): 1241-1251, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31262650

ABSTRACT

BACKGROUND: The management of laparoscopic sleeve gastrectomy leaks remains a challenge. This can be treated with placement of self-expandable metal stents, which are most effective in the acute and early settings. However, migration is a frequent adverse event (AE). Novel, fully covered stents with a larger proximal flare to limit migration designed specifically to treat postsleeve leaks were recently introduced. OBJECTIVES: The aim of this study was to evaluate the safety and efficacy of a novel stent specifically designed for postsleeve leaks treatment. SETTING: Multicenter retrospective study. METHODS: This is a multicenter study, including patients with acute and early post laparoscopic sleeve gastrectomy leaks, treated with a large bariatric stent. The outcomes include technical success, clinical success, and safety profile. A multivariable regression was performed to assess predictors of success. RESULTS: Thirty-seven patients were included (10 acute and 27 early leaks), with 30 stents in the postpyloric (POST) and 7 in the prepyloric position. Technical success was 100%. Mean stent dwell time was 29.08 days. Clinical success was achieved in 78.37%. Leak duration, leak size, and stent dwell time did not correlate with clinical success. During follow-up, 8 patients had stent migration (21.62%) and all were in a POST position. AE poststent removal were also evaluated (prepyloric: 57.14% vs POST: 33.3%, P = .45). There was no difference between prepyloric and POST position in the severe AE analysis. CONCLUSIONS: This novel, large-caliber, fully covered stent specifically designed for sleeve leaks appears to be effective at treating acute and early leaks. However, the large flanges and long stent length do not appear to reduce migration rate and may be associated with higher overall severe AE rates. Avoiding placement in the POST position may help mitigate migration risk; however, owing to the risk profile this stent should be used with caution.


Subject(s)
Anastomotic Leak/epidemiology , Bariatric Surgery , Gastrectomy , Adult , Bariatric Surgery/adverse effects , Bariatric Surgery/instrumentation , Bariatric Surgery/statistics & numerical data , Female , Gastrectomy/adverse effects , Gastrectomy/instrumentation , Gastrectomy/statistics & numerical data , Humans , Male , Middle Aged , Obesity, Morbid/surgery , Retrospective Studies , Treatment Outcome
4.
Obes Surg ; 28(12): 4034-4038, 2018 12.
Article in English | MEDLINE | ID: mdl-30117049

ABSTRACT

BACKGROUND: Complications after bariatric procedures including leaks and strictures can be difficult to treat. Endoscopic treatment may be preferable due to its less invasiveness. The aim of this study is to describe usage of stents in treating complications after bariatric procedures, along with its indications, methods, and outcome. MATERIAL AND METHODS: A total of 87 patients underwent endoscopic stenting after a bariatric procedure from January 1, 2013, and December 31, 2016, in four bariatric centers. Previous bariatric procedures included Roux-en-Y gastric bypass (RYGB) (n = 33), sleeve gastrectomy (n = 50), duodenal switch (DS, n = 2), and vertical banded gastroplasty (VBG, n = 2). RESULTS: Mean age at intervention was 42.6 ± 10.0 years old, and mean body mass index was 41.6 ± 4.0 kg/m2 at the time of bariatric procedure. Reasons for stenting included sleeve leakage (n = 48), gatrojejunostomy (GJ) leakage (n = 21), stricture (n = 8), staple-line disruption (n = 7), and obstruction at the site of ring (n = 2). Migration occurred in 19.5% (n = 17) of patients undergoing stent placement and required repositioning or replacement of stents. Stenosis occurred in 13.8% of patients, which required endoscopic dilatation after stent removal. CONCLUSION: Stents may be useful and effective in managing complications after different bariatric procedures, including RYGB and LSG.


Subject(s)
Bariatric Surgery , Endoscopy , Obesity, Morbid/surgery , Postoperative Complications/therapy , Stents , Adult , Bariatric Surgery/methods , Endoscopy/instrumentation , Endoscopy/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
5.
Obes Surg ; 28(9): 2737-2744, 2018 09.
Article in English | MEDLINE | ID: mdl-29627948

ABSTRACT

BACKGROUND: Endoscopic approaches exist for targeting weight regain after Roux-en-Y gastric bypass (RYGB), including endoscopic suturing, clipping, and sclerotherapy. Argon plasma coagulation (APC) is a noncontact electrocoagulation method, and when used in RYGB patients, it has shown reduction in the diameter of the gastrojejunal anastomosis. OBJECTIVES: To study the effectiveness of APC for weight regain in terms of weight loss for RYGB patients, from eight bariatric centers. METHODS: A retrospective chart review was performed for 558 patients at eight bariatric centers in the USA (1) and Brazil (7) who underwent APC procedure between 31st July 2009 and 29th March 2017. APC was performed on patients who regained weight after RYGB procedure. RESULTS: Upon exploratory analysis of the individual BMI data, the mean BMI decreased slightly during the first 24 months and increased slightly afterwards following the APC intervention. The mean weight was 94.5 ± 18.6 kg and the mean BMI was 34.0 kg/m2 at APC. Where data were available, the mean of lowest weight was 67.0 ± 23.0 kg and the mean of lowest BMI was 24.1 kg/m2 following gastric bypass. The mean weight loss was 6.5, 7.7, and 8.3 kg at 6, 12, and 24 months, respectively, and the changes in weight over time was statistically significant (p < 0.0001). Multi-level for change model showed the low body mass index (BMI) group (BMI < 30 kg/m2) to have greater TWL than the high BMI (BMI ≥ 30 kg/m2) group at 6, 12, and 24 months. In the low BMI group, the mean TWL was 4.7, 6.1, 6.9, and 2.4%, at 6, 12, and 24 months, respectively. In the high BMI group, the mean TWL was 7.5, 10.4, 13.4, and 3.7%, at 6, 12, 24, and 36 months, respectively. Of the 333 patients in four centers who provided complication information, complications after APC included stenosis (n = 9), GJ ulcer (n = 3), vomiting (n = 3), GJ leakage (n = 2), and melena (n = 1). CONCLUSION: APC can be useful in reducing the regained weight after RYGB, and patients showed 6-10% total weight loss at 12 months. Randomized trials would be needed to validate the findings.


Subject(s)
Argon Plasma Coagulation , Gastric Bypass , Obesity, Morbid , Weight Gain/physiology , Body Mass Index , Humans , Obesity, Morbid/epidemiology , Obesity, Morbid/physiopathology , Obesity, Morbid/surgery , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...