Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
PLoS One ; 19(6): e0303397, 2024.
Article in English | MEDLINE | ID: mdl-38848334

ABSTRACT

A novel powered ankle-foot prosthesis is designed. The effect of wearing the novel prosthesis and an energy-storage-and-return (ESAR) foot on lower-limb biomechanics is investigated to preliminarily evaluate the design. With necessary auxiliary materials, a non-amputated subject (a rookie at using prostheses) is recruited to walk on level ground with an ESAR and the novel powered prostheses separately. The results of the stride characteristics, the ground reaction force (GRF) components, kinematics, and kinetics in the sagittal plane are compared. Wearing the powered prosthesis has less prolongation of the gait cycle on the unaffected side than wearing the ESAR foot. Wearing ESAR or proposed powered prostheses influences the GRF, kinematics, and kinetics on the affected and unaffected sides to some extent. Thereinto, the knee moment on the affected side is influenced most. Regarding normal walking as the reference, among the total of 15 indexes, the influences of wearing the proposed powered prosthesis on six indexes on the affected side (ankle's/knee's/hip's angles, hip's moment, and Z- and X-axis GRF components) and five indexes on the unaffected side (ankle's/knee's/hip's angles and ankle's/hip's moments) are slighter than those of wearing the ESAR foot. The influences of wearing the powered prosthesis on two indexes on the unaffected side (knee's moment and X-axis GRF component) are similar to those of wearing the ESAR foot. The greatest improvement of wearing the powered prosthesis is to provide further plantarflexion after reaching the origin of the ankle joint before toe-off, which means that the designed powered device can provide further propulsive power for the lifting of the human body's centre of gravity during walking on level ground. The results demonstrate that wearing the novel powered ankle-foot prosthesis benefits the rookie in recovering the normal gait more than wearing the ESAR foot.


Subject(s)
Artificial Limbs , Foot , Prosthesis Design , Humans , Biomechanical Phenomena , Foot/physiology , Gait/physiology , Walking/physiology , Male , Ankle/physiology , Ankle Joint/physiology , Adult , Lower Extremity/physiology
2.
Polymers (Basel) ; 15(2)2023 Jan 04.
Article in English | MEDLINE | ID: mdl-36679135

ABSTRACT

3D printing is the most suitable method to manufacture the frame parts of powered ankle-foot prostheses but the compressive strength of the 3D-printed part needs to be ensured. According to the compression test standard ASTM D695, the effect of infill pattern and density, which is transferred to the mass of the standard specimen, on the compressive strength is investigated with a carbon fiber-reinforced nylon material. With the same infill pattern, specimens with more mass have a higher compressive strength. With the same mass, specimens with triangular fill have a higher compressive strength than those with rectangular and gyroid fills. Compared with specimens with a solid fill, specimens with a triangular fill can also provide more compressive strength in a unit mass. According to the results of standard specimens, following the requirement of strength and lightweight, 41% triangular fill is selected to manufacture the supporting part of a powered ankle-foot prosthesis. Under a compressive load of 1225 N, the strain of the assembly of the standard adaptor and the 3D-printed part is 1.32 ± 0.04%, which can meet the requirement of the design. This study can provide evidence for other 3D-printed applications with the requirement of compressive strength.

3.
Sci Rep ; 12(1): 11217, 2022 Jul 02.
Article in English | MEDLINE | ID: mdl-35780242

ABSTRACT

Planar spiral spring is important for the dimensional miniaturisation of motor-based elastic actuators. However, when the stiffness calculation of the spring arm is based on simple beam bending theory, the results possess substantial errors compared with the stiffness obtained from finite-element analysis (FEA). It deems that the errors arise from the spiral length term in the calculation formula. Two Gaussian process regression models are trained to amend this term in the stiffness calculation of spring arm and complete spring. For the former, 216 spring arms' data sets, including different spiral radiuses, pitches, wrap angles and the stiffness from FEA, are employed for training. The latter engages 180 double-arm springs' data sets, including widths instead of wrap angles. The simulation of five spring arms and five planar spiral springs with arbitrary dimensional parameters verifies that the absolute values of errors between the predicted stiffness and the stiffness from FEA are reduced to be less than 0.5% and 2.8%, respectively. A planar spiral spring for a powered ankle-foot prosthesis is designed and manufactured to verify further, of which the predicted value possesses a 3.25% error compared with the measured stiffness. Therefore, the amendment based on the prediction of trained models is available.

4.
Sports Biomech ; 21(9): 1065-1081, 2022 Oct.
Article in English | MEDLINE | ID: mdl-32138608

ABSTRACT

Service is assumed important in table tennis because an effective service may allow the serving player to control over the game; hence, the aim of this study was to determine the contribution of arm segment rotations towards ball impact during forehand service. Sixteen shake-hand grip collegiate table tennis athletes had participated in the study. It was revealed that by increasing the radial deviation angular velocity will increase the ball and racket velocities during drop shot service. Furthermore, it was revealed that increasing the wrist palmar flexion and radial deviation will enhance the racket velocity at impact during long shot service. However, it was recommended to the players not to concern on racket speed and arm segment rotations during contact phase as it could not accelerate the ball at impact during long shot service. Although it was the same forehand service, different length of flight ball lead to different contributions of arm segment rotations towards ball impact. The present findings highlight several better postures to increase racket and ball speed at impact during forehand long shot and drop shot services among advanced and intermediate players. Other ranked players may find this study useful as a fundamental understanding on kinematics serving arm.


Subject(s)
Tennis , Arm , Biomechanical Phenomena , Hand Strength , Humans , Range of Motion, Articular
5.
J Biomed Opt ; 22(8): 1-8, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28822140

ABSTRACT

This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers between which 12 FBG sensors were embedded at locations of clinical interest. The sensors were then calibrated using a custom calibration platform that mimics a real-life situation. Afterward, a custom gait simulating machine was built to test the liner performance during an amputee's simulated gait. To validate the findings, the results were compared to those obtained by the commonly used F-socket mats. As the statistical findings reveal, both pressure mapping methods measured the interface pressure in a consistent way, with no significant difference (P-values ≥0.05). This pressure mapping technique in the form of a prosthetic liner will allow prosthetics professionals to quickly and accurately create an overall picture of the interface pressure distribution inside sockets in research and clinical settings, thereby improving the socket fit and amputee's satisfaction.


Subject(s)
Amputees , Artificial Limbs , Pressure , Protective Devices , Silicones , Humans , Leg , Optical Fibers , Prosthesis Design
6.
Malays J Med Sci ; 24(5): 106-111, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29386978

ABSTRACT

The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved.

7.
Prosthet Orthot Int ; 40(4): 509-16, 2016 Aug.
Article in English | MEDLINE | ID: mdl-25583929

ABSTRACT

BACKGROUND: This article describes a total surface bearing prosthetic socket for a patient (25-year-old female) with a bulbous stump. CASE DESCRIPTION AND METHODS: The subject had unstable excessive soft tissue at the distal end of the residuum. After 2 years of prosthetic use, she experienced several problems, including pain in the residual limb and knee joint. Pressure distribution was evaluated during ambulation. We also designed a total surface bearing socket with Velcro as suspension system to distribute the load evenly on the residual limb, and to facilitate donning procedure. FINDINGS AND OUTCOMES: The main site of weight bearing in the old prosthesis (patellar tendon bearing) was anterior proximal region of the residual limb, especially the patellar tendon. The pressure was almost 10 times higher than the distal region during level walking. Pressures were distributed more evenly with the total surface bearing socket design, and the donning was much easier. CONCLUSION: Pressure distribution within the socket could be affected by socket design and suspension system. Using the total surface bearing socket and Velcro as suspension system might facilitate donning of prosthesis and reduce traction at the end of residual limb during the swing phase of gait. CLINICAL RELEVANCE: Proper socket design and suspension system based on the amputees' need can facilitate rehabilitation process and lead to the amputee's satisfaction. The pressure is distributed more uniformly over the residual limb by the total surface bearing socket compared to the patellar tendon bearing socket for lower limb amputees with unusual stump shape.


Subject(s)
Artificial Limbs , Prosthesis Design , Walking/physiology , Weight-Bearing/physiology , Adult , Amputation, Surgical , Amputation Stumps , Female , Humans , Tibia
8.
Proc Inst Mech Eng H ; 229(7): 491-8, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26019139

ABSTRACT

In recent years, computerized posturography has become an essential tool in quantitative assessment of postural steadiness in the clinical settings. The purpose of this study was to explore the ability of the Biodex(®) Stability System (BSS) to quantify postural steadiness in below-knee amputees. A convenience sample of 10 below-knee amputees participated in the study. The overall (OSI), anterior-posterior (APSI) and medial-lateral (MLSI) stability indexes as well as the percentage of time spent in left and right quadrants and four concentric zones were measured under altered sensory conditions while standing with solid ankle cushion heel (SACH), single-axis (SA) and energy storage and release (ESAR) feet. Significant difference was found between sensory conditions in SACH and ESAR feet for OSI (SACH, p = 0.002; ESAR, p = 0.005), APSI (SACH, p = 0.036; ESAR, p = 0.003) and MLSI (SACH, p = 0.008; ESAR, p = 0.05) stability indexes. The percentage of time spent in Zone A (0°-5°) was significantly greater than the other three concentric zones (p < 0.01). The loading time percentage on their intact limb (80%-94%) was significantly longer than the amputated limb (20%-6%) in all conditions for all three prosthetic feet. Below-knee amputees showed compromised postural steadiness when visual, proprioceptive or vestibular sensory input was altered. The findings highlight that the characteristics of postural stability in amputees can be clinically assessed by utilizing the outcomes produced by the BSS.


Subject(s)
Amputees/rehabilitation , Artificial Limbs , Foot/physiology , Postural Balance/physiology , Adult , Biomedical Engineering , Humans , Male , Middle Aged , Young Adult
9.
ScientificWorldJournal ; 2014: 769810, 2014.
Article in English | MEDLINE | ID: mdl-25184154

ABSTRACT

PURPOSE: This study aimed to compare the effect of satisfaction and perceived problems between Pelite, Dermo with shuttle lock, and Seal-In X5 liners on the transtibial amputees. MATERIAL AND METHODS: A total of thirty transtibial amputees (17 male, 13 female) volunteered to take part in this research. Two prostheses were fabricated for each participant. Prosthetic Evaluation Questionnaire (PEQ) was filled in by the participants with the three liners. RESULTS: The statistics highlight that Dermo liner showed significantly higher score (P = 0.05) in walking, walking on uneven surfaces, stairs walking, fitting, donning/doffing, sitting, suspension, and overall satisfaction with Dermo liner compared with Seal-In X5 and Pelite liners. Overall satisfaction was 34% higher with Dermo liner than Seal-In X5 liner and 28% higher than Pelite liner. Participants reported less problems with Dermo liner and significant differences (P < 0.05) were recorded between the three liners in sweating, skin irritation, frustration, and pain compared with Seal-In X5 and Pelite liners. CONCLUSION: Participants experienced high level of satisfaction and practiced fewer problems with Dermo liner. These results showed that there is good indication to believe that Dermo liner might be a good choice for transtibial users and might help the clinicians and prosthetic practitioners in selection criteria of prosthetic liners.


Subject(s)
Amputees/psychology , Patient Satisfaction/statistics & numerical data , Prosthesis Design , Adult , Female , Humans , Male , Middle Aged , Surveys and Questionnaires
10.
ScientificWorldJournal ; 2014: 856279, 2014.
Article in English | MEDLINE | ID: mdl-25003155

ABSTRACT

PURPOSE: This study aimed to evaluate the effects of prosthetic foot types on the postural stability among transtibial amputees when standing on different support surfaces. MATERIALS AND METHODS: The postural stability of 10 transtibial amputees wearing solid ankle cushion heel (SACH) foot, single-axis (SA) foot, and energy-saving and return (ESAR) foot was assessed. Results were compared with able-bodied participants. Anterior-posterior stability index (APSI), mediolateral stability index (MLSI), and overall stability index (OSI) were measured by computed posturography in an upright stance on firm, foam, and unstable support surfaces. RESULTS: The mean OSI score of SACH foot was significantly lower than that of an ESAR foot when the participants were standing on a compliant surface. When compared to able-bodied group, MLSI score was significantly higher for each of the prosthetic foot groups while OSI score was significantly higher for ESAR foot only in foam condition. CONCLUSIONS: Differences between prosthetic foot types and groups (amputees versus able-bodied) can only be distinguished when individuals were standing on a compliant surface. Amputees exhibited an increased postural instability in the mediolateral direction than able-bodied individuals. Hence, the restoration of stability in the frontal plane and the enhancement of proprioception at the residual limb should be the basis of rehabilitation programs.


Subject(s)
Amputees/rehabilitation , Artificial Limbs , Postural Balance , Adult , Case-Control Studies , Humans , Male , Middle Aged
11.
Biomed Eng Online ; 13(1): 23, 2014 Mar 05.
Article in English | MEDLINE | ID: mdl-24597518

ABSTRACT

BACKGROUND: Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet. METHODS: Ten male below-knee amputees were instructed to stand quietly on the Biodex® balance platform while wearing solid ankle cushion heel (SACH), single axis (SA) and energy storage and release (ESAR) prosthetic foot under different visual input conditions (eyes-opened and eyes-closed). The overall stability index (OSI), anterior- posterior stability index (APSI), and medial-lateral stability index (MLSI) were computed. Perceived balance assessment of each foot was evaluated using Activities-specific Balance Confidence (ABC) score. RESULTS: The findings highlights that SACH showed lowest overall stability index (indicating less body sway) during eyes-opened (OSI: SACH = 1.09, SA = 1.58, ESAR = 1.59) and SA showed lowest overall stability index during eyes-closed (OSI: SACH = 2.52, SA = 2.30, ESAR = 2.76) condition. However, overall stability indexes between foot types did not differ significantly during eyes-opened or eyes-closed (p = 0.651). There was a trend of instability which occurred more in medial-lateral compared to anterior-posterior direction for all foot types, with significant result in ESAR foot(eyes-opened: MLSI = 1.59, APSI = 0.65, p = 0.034; eyes-closed: MLSI = 2.76, APSI = 1.80, p = 0.017, respectively). When comparing between visual conditions, stability score was significantly higher during eyes-closed compared to eyes-opened situations for SACH and ESAR foot (eyes-closed vs opened; SACH OSI: 3.43 vs 1.71, p = 0.018 and MLSI: 3.43 vs 1.71, p = 0.018; ESAR OSI: 3.58 vs 1.86, p = 0.043 and APSI: 1.80 vs 0.65, p = 0.027). CONCLUSIONS: The results of this study suggested postural steadiness in below-knee amputees was not affected by the types of prosthetic foot during quiet upright standing, but was significantly affected when visual cues was absent.


Subject(s)
Artificial Limbs , Foot/physiology , Postural Balance , Adult , Amputees , Ankle/physiology , Female , Humans , Male , Middle Aged , Prosthesis Design , Young Adult
12.
Biomed Eng Online ; 13: 1, 2014 Jan 10.
Article in English | MEDLINE | ID: mdl-24410918

ABSTRACT

BACKGROUND: Good prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems). METHODS: All the suspension systems were tested (tensile testing machine) in terms of the degree of the shear strength and the patient's comfort. Nine transtibial amputees participated in this study. The patients were asked to use four different suspension systems. Afterwards, each participant completed a questionnaire for each system to evaluate their comfort. Furthermore, the systems were compared in terms of the cost. RESULTS: The maximum tensile load that the new system could bear was 490 N (SD, 5.5) before the system failed. Pin/lock, magnetic and suction suspension systems could tolerate loads of 580 N (SD, 8.5), 350.9 (SD, 7) and 310 N (SD, 8.4), respectively. Our subjects were satisfied with the new hook and loop system, particularly in terms of easy donning and doffing. Furthermore, the new system is considerably cheaper (35 times) than the current locking systems in the market. CONCLUSIONS: The new suspension system could successfully retain the prosthesis on the residual limb as a good alternative for lower limb amputees. In addition, the new system addresses some problems of the existing systems and is more cost effective than its counterparts.


Subject(s)
Artificial Limbs , Materials Testing/methods , Mechanical Phenomena , Adult , Humans , Male , Materials Testing/instrumentation , Movement , Prosthesis Design , Shear Strength
13.
J Appl Biomech ; 30(2): 300-4, 2014 Apr.
Article in English | MEDLINE | ID: mdl-23878204

ABSTRACT

The measurements of postural balance often involve measurement error, which affects the analysis and interpretation of the outcomes. In most of the existing clinical rehabilitation research, the ability to produce reliable measures is a prerequisite for an accurate assessment of an intervention after a period of time. Although clinical balance assessment has been performed in previous study, none has determined the intrarater test-retest reliability of static and dynamic stability indexes during dominant single stance. In this study, one rater examined 20 healthy university students (female=12, male=8) in two sessions separated by 7 day intervals. Three stability indexes--the overall stability index (OSI), anterior/posterior stability index (APSI), and medial/ lateral stability index (MLSI) in static and dynamic conditions--were measured during single dominant stance. Intraclass correlation coefficient (ICC), standard error measurement (SEM) and 95% confidence interval (95% CI) were calculated. Test-retest ICCs for OSI, APSI, and MLSI were 0.85, 0.78, and 0.84 during static condition and were 0.77, 0.77, and 0.65 during dynamic condition, respectively. We concluded that the postural stability assessment using Biodex stability system demonstrates good-to-excellent test-retest reliability over a 1 week time interval.


Subject(s)
Postural Balance/physiology , Biomechanical Phenomena , Female , Humans , Male , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...