Sci Rep ; 14(1): 10252, 2024 05 04.
Article En | MEDLINE | ID: mdl-38704459

About one in three critically ill patients requires mechanical ventilation (MV). Prolonged MV, however, results in diaphragmatic weakness, which itself is associated with delayed weaning and increased mortality. Inducing active diaphragmatic contraction via electrical phrenic nerve stimulation (PNS) not only provides the potential to reduce diaphragmatic muscular atrophy but also generates physiological-like ventilation and therefore offers a promising alternative to MV. Reasons why PNS is not yet used in critical care medicine are high procedural invasiveness, insufficient evidence, and lack of side-by-side comparison to MV. This study aims to establish a minimal-invasive percutaneous, bilateral electrode placement approach for sole PNS breathing and thereby enable, for the first time, a breath-by-breath comparison to MV. Six juvenile German Landrace pigs received general anesthesia and orotracheal intubation. Following the novel ultrasound-guided, landmark-based, 4-step approach, two echogenic needles per phrenic nerve were successfully placed. Stimulation effectiveness was evaluated measuring tidal volume, diaphragmatic thickening and tomographic electrical impedance in a breath-by-breath comparison to MV. Following sufficient bilateral phrenic nerve stimulation in all pigs, PNS breaths showed a 2.2-fold increase in diaphragmatic thickening. It induced tidal volumes in the lung-protective range by negative pressure inspiration and improved dorso-caudal regional ventilation in contrast to MV. Our study demonstrated the feasibility of a novel ultrasound-guided, percutaneous phrenic nerve stimulation approach, which generated sufficient tidal volumes and showed more resemblance to physiological breathing than MV in a breath-by-breath comparison.


Diaphragm , Phrenic Nerve , Respiration, Artificial , Animals , Phrenic Nerve/physiology , Respiration, Artificial/methods , Swine , Pilot Projects , Diaphragm/innervation , Diaphragm/physiology , Tidal Volume , Electric Stimulation Therapy/methods , Transcutaneous Electric Nerve Stimulation/methods , Electric Stimulation/methods
2.
Animals (Basel) ; 13(22)2023 Nov 15.
Article En | MEDLINE | ID: mdl-38003149

The development of biomedical soft- or hardware frequently includes testing in animals. However, large efforts have been made to reduce the number of animal experiments, according to the 3Rs principle. Simultaneously, a significant number of surplus animals are euthanized without scientific necessity. The primary aim of this study was to establish a post-mortem rat perfusion model using extracorporeal membrane oxygenation (ECMO) in surplus rat cadavers and generate first post vivo results concerning the oxygenation performance of a recently developed ECMO membrane oxygenator. Four rats were euthanized and connected post-mortem to a venous-arterial ECMO circulation for up to eight hours. Angiographic perfusion proofs, blood gas analyses and blood oxygenation calculations were performed. The mean preparation time for the ECMO system was 791 ± 29 s and sufficient organ perfusion could be maintained for 463 ± 26 min, proofed via angiographic imaging and a mean femoral arterial pressure of 43 ± 17 mmHg. A stable partial oxygen pressure, a 73% rise in arterial oxygen concentration and an exponentially increasing oxygen extraction ratio up to 4.75 times were shown. Considering the 3Rs, the established post-mortal ECMO perfusion rat model using surplus animals represents a promising alternative to models using live animals. Given the preserved organ perfusion, its use could be conceivable for various biomedical device testing.

3.
Sci Rep ; 13(1): 11303, 2023 07 12.
Article En | MEDLINE | ID: mdl-37438391

Diaphragm atrophy is a common side effect of mechanical ventilation and results in prolonged weaning. Electric phrenic nerve stimulation presents a possibility to avoid diaphragm atrophy by keeping the diaphragm conditioned in sedated patients. There is a need of further investigation on how to set stimulation parameters to achieve sufficient ventilation. A prototype system is presented with a systematic evaluation for stimulation pattern adjustments. The main indicator for efficient stimulation was the tidal volume. The evaluation was performed in two pig models. As a major finding, the results for biphasic pulses were more consistent than for alternating pulses. The tidal volume increased for a range of pulse frequency and pulse width until reaching a plateau at 80-120 Hz and 0.15 ms. Furthermore, the generated tidal volume and the stimulation pulse frequency were significantly correlated (0.42-0.84, [Formula: see text]). The results show which stimulation parameter combinations generate the highest tidal volume. We established a guideline on how to set stimulation parameters. The guideline is helpful for future clinical applications of phrenic nerve stimulation.


Phrenic Nerve , Respiration, Artificial , Animals , Swine , Respiration, Artificial/adverse effects , Pilot Projects , Respiration , Atrophy
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 135-138, 2022 07.
Article En | MEDLINE | ID: mdl-36085952

While mechanical ventilation (MV) can lead to ventilator-induced diaphragmatic atrophy due to diaphragm inactivity, electrical phrenic nerve stimulation (PNS) can keep the diaphragm active and therefore prevent diaphragmatic weakness. To quantify the effectivity of PNS, an identification experiment during PNS is presented, and its data is used in Gaussian process regression (GPR) of the tidal volume based on the constant voltage amplitude of the stimulation pulses. The measurements were split into training data of variable size and test data for cross validation. For variable training sizes and different PNS settings, the GPR had a root mean square deviation (RMSD) between 0.39 and 0.91 mL/kg. An identification experiment as short as one and a half minutes was able to characteristically capture the relationship between tidal volume and voltage amplitude. The proposed method needs to be validated in further experiments.


Phrenic Nerve , Respiration Disorders , Diaphragm/physiology , Humans , Phrenic Nerve/physiology , Respiration, Artificial , Tidal Volume
...