Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Orthop Surg ; 16(4): 570-577, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39092300

ABSTRACT

Background: Increased load bearing across the patellofemoral and tibiofemoral articulations has been associated with total knee arthroplasty (TKA) complications. Therefore, the purpose of this study was to quantify the biomechanical characteristics of the patellofemoral and tibiofemoral joints and simulate varying weight-bearing demands after posterior cruciate ligament-retaining (CR) and posterior-stabilized (PS) TKAs. Methods: Eight fresh-frozen cadaveric knees (average age, 68.4 years; range, 40-86 years) were tested using a custom knee system with muscle-loading capabilities. The TKA knees were tested with a CR and then a PS TKA implant and were loaded at 6 different flexion angles from 15° to 90° with progressively increasing loads. The independent variables were the implant types (CR and PS TKA), progressively increased loading, and knee flexion angle (KFA). The dependent variables were the patellofemoral and tibiofemoral kinematics and contact characteristics. Results: The results showed that at higher KFAs, the position of the femur translated significantly more posterior in CR implants than in PS implants (36.6 ± 5.2 mm and 32.5 ± 5.7 mm, respectively). The patellofemoral contact force and contact area were significantly greater in PS than in CR implants at higher KFAs and loads (102.4 ± 12.5 N and 88.1 ± 10.9 N, respectively). Lastly, the tibiofemoral contact force was significantly greater in the CR than the PS implant at flexion angles of 45°, 60°, 75°, and 90° KFA, the average at these flexion angles for all loads tested being 246.1 ± 42.1 N and 192.8 ± 54.8 N for CR and PS implants, respectively. Conclusions: In this biomechanical study, CR TKAs showed less patellofemoral contact force, but more tibiofemoral contact force than PS TKAs. For higher loads across the joint and at increased flexion angles, there was significantly more posterior femur translation in the CR design with a preserved posterior cruciate ligament and therefore significantly less patellofemoral contact area and force than in the PS design. The different effects of loading on implants are an important consideration for physicians as patients with higher load demands should consider the significantly greater patellofemoral contact force and area of the PS over the CR design.


Subject(s)
Arthroplasty, Replacement, Knee , Posterior Cruciate Ligament , Weight-Bearing , Humans , Aged , Biomechanical Phenomena , Aged, 80 and over , Weight-Bearing/physiology , Middle Aged , Posterior Cruciate Ligament/surgery , Adult , Male , Female , Cadaver , Knee Joint/surgery , Knee Joint/physiology , Knee Prosthesis , Patellofemoral Joint/surgery , Patellofemoral Joint/physiology , Range of Motion, Articular
2.
J Addict Dis ; : 1-6, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38913072

ABSTRACT

Nitrous oxide is used medically as an anesthetic agent; in the food industry as a propellant for condiments; and recreationally for its euphoric and dissociative effects. We report three cases of nitrous oxide misuse causing severe, symptomatic cobalamin (vitamin B12) deficiency in which signs of nitrous oxide use per se, as well as signs of toxicity, were observed, including characteristic palmar calluses over the metacarpal heads, and frostbite. These signs may assist clinicians in the recognition of nitrous oxide use and the timely diagnosis of nitrous oxide toxicity.

SELECTION OF CITATIONS
SEARCH DETAIL