ABSTRACT
OBJECTIVE: Transbronchial lung cryobiopsy (TBCB) has developed rapidly and has become one of the research hotspots of lung biopsy technology. The present study sought to evaluate the efficacy of TBCB guided by radial-probe EBUS (RP-EBUS) and a guide sheath (GS) without fluoroscopy for peripheral pulmonary lesions. METHODS: In this retrospective study, McNemar's test was used in order to compare TBCB and transbronchial forceps biopsy (TBFB) in terms of diagnostic performance. A multivariate logistic regression model was designed to explore the association between predictive variables and the diagnostic yield of TBCB. RESULTS: A total of 168 patients underwent GS-guided RP-EBUS. Of those, 157 had lesions that were visible and 11 had lesions that were not. Of those 157 patients, 24 were excluded because of missing data or an unclear final diagnosis. Therefore, 133 patients underwent RP-EBUS-GS-guided TBFB and TBCB. The pooled diagnostic yield of RP-EBUS-GS-guided TBCB without fluoroscopy was 71.5% (103/144). In 133 patients, the diagnostic yield of TBCB was significantly higher than that of TBFB (77.4% vs. 59.4%; p < 0.05). Multivariate analysis indicated that lesion size and site were independently associated with the diagnostic yield of TBCB (OR = 2.8, p = 0.03 and OR = 4.1, p = 0.01, respectively), although cryoprobe size was not. There was no significant difference between the 1.1-mm cryoprobe and the 1.9-mm cryoprobe in terms of diagnostic performance (78.4% vs. 76.8%; p > 0.05). CONCLUSIONS: GS-guided RP-EBUS is regarded as a practical option for guiding cryobiopsy, although it may not be able to replace fluoroscopy. Peripheral pulmonary lesions not located in the upper lobes or larger than 30 mm are significantly associated with a higher diagnostic yield of cryobiopsy.
Subject(s)
Lung Diseases , Lung Neoplasms , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Retrospective Studies , Bronchoscopy , Lung/diagnostic imaging , Lung/pathology , Lung Diseases/pathology , Endosonography , BiopsyABSTRACT
ABSTRACT Objective: Transbronchial lung cryobiopsy (TBCB) has developed rapidly and has become one of the research hotspots of lung biopsy technology. The present study sought to evaluate the efficacy of TBCB guided by radial-probe EBUS (RP-EBUS) and a guide sheath (GS) without fluoroscopy for peripheral pulmonary lesions. Methods: In this retrospective study, McNemar's test was used in order to compare TBCB and transbronchial forceps biopsy (TBFB) in terms of diagnostic performance. A multivariate logistic regression model was designed to explore the association between predictive variables and the diagnostic yield of TBCB. Results: A total of 168 patients underwent GS-guided RP-EBUS. Of those, 157 had lesions that were visible and 11 had lesions that were not. Of those 157 patients, 24 were excluded because of missing data or an unclear final diagnosis. Therefore, 133 patients underwent RP-EBUS-GS-guided TBFB and TBCB. The pooled diagnostic yield of RP-EBUS-GS-guided TBCB without fluoroscopy was 71.5% (103/144). In 133 patients, the diagnostic yield of TBCB was significantly higher than that of TBFB (77.4% vs. 59.4%; p < 0.05). Multivariate analysis indicated that lesion size and site were independently associated with the diagnostic yield of TBCB (OR = 2.8, p = 0.03 and OR = 4.1, p = 0.01, respectively), although cryoprobe size was not. There was no significant difference between the 1.1-mm cryoprobe and the 1.9-mm cryoprobe in terms of diagnostic performance (78.4% vs. 76.8%; p > 0.05). Conclusions: GS-guided RP-EBUS is regarded as a practical option for guiding cryobiopsy, although it may not be able to replace fluoroscopy. Peripheral pulmonary lesions not located in the upper lobes or larger than 30 mm are significantly associated with a higher diagnostic yield of cryobiopsy.
RESUMO Objetivo: A criobiópsia transbrônquica (CBTB) desenvolveu-se rapidamente e tornou-se um dos focos de pesquisa de tecnologia de biópsia pulmonar. O presente estudo buscou avaliar a eficácia da CBTB guiada por EBUS radial com bainha guia sem fluoroscopia no diagnóstico de lesões pulmonares periféricas. Métodos: Neste estudo retrospectivo, o teste de McNemar foi usado para comparar a CBTB e a biópsia transbrônquica com pinça (BTB) quanto ao desempenho diagnóstico. Um modelo de regressão logística multivariada foi criado para explorar a relação entre variáveis preditivas e o rendimento diagnóstico da CBTB. Resultados: Um total de 168 pacientes foram submetidos a EBUS radial com bainha guia. Destes, 157 apresentavam lesões que puderam ser visualizadas e 11 apresentavam lesões que não puderam ser visualizadas. Dos 157 pacientes, 24 foram excluídos em virtude de dados incompletos ou diagnóstico final incerto. Portanto, 133 pacientes foram submetidos a BTB e CBTB guiadas por EBUS radial com bainha guia. O rendimento diagnóstico combinado da CBTB guiada por EBUS radial com bainha guia foi de 71,5%. O rendimento diagnóstico da CBTB foi significativamente maior que o da BTB (77,4% vs. 59,4%; p < 0,05). A análise multivariada indicou que o tamanho e o local da lesão apresentaram relação independente com o rendimento diagnóstico da CBTB (OR = 2,8, p = 0,03 e OR = 4,1, p = 0,01, respectivamente); o tamanho da criossonda, por sua vez, não apresentou relação com o rendimento diagnóstico da CBTB. Não houve diferença significativa entre a criossonda de 1,1 mm e a de 1,9 mm no que tange ao desempenho diagnóstico (78,4% vs. 76,8%; p > 0,05). Conclusões: EBUS radial com bainha guia é uma opção prática para guiar a criobiópsia, embora talvez não possa substituir a fluoroscopia. Lesões pulmonares periféricas que não estejam nos lobos superiores ou que tenham mais de 30 mm apresentam relação significativa com maior rendimento diagnóstico da criobiópsia.