Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 50
1.
Int J Cardiol Heart Vasc ; 49: 101303, 2023 Dec.
Article En | MEDLINE | ID: mdl-38076346

Background: Spontaneous coronary artery dissection (SCAD) is a relatively rare condition affecting predominantly young adults, with a prevalence of female sex. The best management of SCAD is still unclear and not adequately evidence-based both in the acute phase but especially over the long-term. We therefore aimed to evaluate the impact of medical therapy usually adopted for coronary artery disease on long-term outcome in SCAD patients. Methods: We performed a meta-regression analysis including all the studies evaluating the long-term outcome of patients affected by SCAD. We used long-term mortality, recurrent SCAD, admission for angina and major adverse cardio-vascular events (MACE) as dependent variables and the rates of discharge drug rates (beta-blockers, statins, renin-angiotensin-aldosterone system inhibitors, aspirin, dual antiplatelet therapy (DAPT)) as independent variables. Results: Fourteen observational studies were included with a long-term follow-up of 3.5 ± 1.7 years. No statistically significant correlations between drug therapy (beta-blockers, statins, calcium channel blockers, nitrates, renin-angiotensin-aldosterone inhibitors) and mortality, MACE, admission for angina, and SCAD recurrence were found. Higher aspirin use rates were significantly correlated with lower admission rates for angina (p < 0.05); DAPT, however, showed a borderline correlation with higher rates of SCAD recurrence (p = 0.068). Conclusions: In a meta-regression analysis including observational studies aspirin use rates correlated with lower long-term rates of admission for angina, while a borderline correlation between DAPT and rates of SCAD recurrence was found. Other drugs usually used for the treatment of coronary artery disease do not seem to impact long-term outcome of SCAD patients.

2.
Vaccine X ; 14: 100291, 2023 Aug.
Article En | MEDLINE | ID: mdl-37091728

Introduction: We sought to assess the impact of SarsCov-2 vaccination on admission12-lead electrocardiogram of hospitalized patients. Methods: We retrospectively analyzed and compared admission 12-lead electrocardiograms of all patients hospitalized in dedicated Internal Medicine Unit for Covid-19 both in pre-vaccination period (PV) and after vaccination (V). Results: 667 consecutive Covid-19 in-patients were enrolled in the study: PV hospitalized patients were older (68vs57 years, p < 0.01), had higher rates of atrial fibrillation/flutter (13%vs2.5%, p < 0.01), any arrhythmia (26%vs8%, p < 0.01), and ST-T abnormalities (22%vs7.4%, p < 0.01). Mortality rates in hospitalized Covid-19 patients were higher before vaccination period (20%vs4%, p < 0.01). Minimal vaccination coverage of population (V period) was inversely and independently associated with in-hospital mortality (odds ratio 0.09, 95%CI 0.01-0.68, p < 0.05). Conclusions: SarsCov-2 vaccination campaign and even partial coverage of local population was associated with less frequent abnormalities at admission ECG in hospitalized non-critically hill Covid-19 patients and lower mortality.

3.
Int J Cardiovasc Imaging ; 39(1): 43-50, 2023 Jan.
Article En | MEDLINE | ID: mdl-36598687

The renal resistance index (RRI) has been demonstrated to be a useful parameter that can detect patients at a high risk of worsening of renal function (WRF). This study was designed to evaluate the role of the RRI in predicting WRF mediated by the intravascular administration of contrast media. We enrolled patients who were referred for coronary angiography. Renal arterial echo-color Doppler was performed to calculate the RRI. WRF was defined as an increase of > 0.3 mg/dL and at least 25% of the baseline value in creatinine concentration 24-48 h after coronary angiography. Among the 148 patients enrolled in this study, 18 (12%) had WRF. In the multivariate logistic analysis, the RRI was independently associated with WRF (odds ratio [OR]: 1.22; 95% confidence interval [CI]: 1.09-1.36; p = 0.001). After angiography, the RRI significantly increased in both patients with and without WRF. In the receiver operating characteristic curve analyses for WRF, the RRI at baseline and after angiography showed similar accuracy, and the best cutoff value for predicting WRF was 70%. In patients undergoing coronary angiography, the RRI is independently associated with WRF, probably because it provides more accurate information about cardiorenal pathophysiological factors and reflects kidney hemodynamic status and flow reserve.


Acute Kidney Injury , Heart Failure , Humans , Coronary Angiography/adverse effects , Predictive Value of Tests , Kidney , Acute Kidney Injury/diagnosis , Contrast Media/adverse effects , Creatinine , Prognosis
4.
J Vasc Access ; : 11297298221145752, 2022 Dec 27.
Article En | MEDLINE | ID: mdl-36573696

BACKGROUND: Trans-radial access is considered the best approach for cardiac catheterization. The choice of an alternative access route may be complex and trans-femoral access (TFA) is generally preferred. However, trans-brachial approach (TBA) may represent another feasible alternative. We therefore aimed to compare TBA and TFA in terms of access site bleeding and complications in a meta-analysis study. METHODS: We systematically searched principal databases for studies comparing femoral and brachial approach in terms of in-hospital vascular complications in patients undergoing cardiac catheterization (coronary angiography or percutaneous coronary intervention). RESULTS: Five retrospective studies and one randomized study were identified for the meta-analysis; 2756 patients undergoing a TBA and 331.208 patients undergoing a TFA for cardiac catheterization were included in the final study. No significant differences between access routes were found in terms of risk of any vascular complications (relative risk 1.18; 95% CI: 0.91-1.53; p n.s.). Brachial access was associated with a significantly lower risk of access site bleeding (relative risk 0.46; 95% CI 0.24-0.88, p = 0.02). CONCLUSIONS: TBA for cardiac catheterization was associated with a lower risk of access site bleeding and a comparable risk of any vascular complications compared with TFA. TBA may be considered a reasonable alternative access route for cardiac catheterization, at least as femoral approach.

6.
Cardiovasc Revasc Med ; 30: 1-8, 2021 09.
Article En | MEDLINE | ID: mdl-33077393

AIM: To compare the long-term outcomes of patients implanted with Absorb bioresorbable scaffold (BRS) with optimal versus suboptimal technique. METHODS AND RESULTS: All patients who received an Absorb between March 2012 and January 2016 were selected from 19 Italian centers databases to assess the impact of an optimal implantation technique (CIAO criteria) on long-term device-oriented composite end-point (DOCE) - including cardiac death (CD), target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) - on its single components and on scaffold thrombosis (ScT). CIAO criteria consist of predilation (balloon/vessel ratio 1:1), correct sizing (BRS/proximal reference vessel diameter -RVD- ratio 0.8-1.2) and high-pressure postdilation with non-compliant (NC) balloon (≥20 atm for balloon/BRS ratio 1:1 or ≥16 atm for a 0.25-0.5 mm oversized balloon). Among the 1.434 patients analyzed, 464 (32.4%) fulfilled all CIAO criteria for every BRS implanted (CIAO 3 group), while 970 (67.6%) did not in at least one of the received BRS (CIAO 0-1-2 group). At 31.0 (interquartile range -IQR- 24.8-38.5) months follow-up, CIAO criteria did not impact on DOCE (8.2% vs. 8.0%, p = 0.92), ID-TLR (6.9% vs. 7.1%, p = 0.72) or ScT (1.9% vs. 1.8%, p = 0.80) in the overall population. At multivariate analysis overall BRS length (p = 0.001), severely calcified lesions (p = 0.03) and absence of CIAO criteria (CIAO 0, p = 0.005) were independent predictors of DOCE in long-term follow-up. CONCLUSION: Our data suggest that strict application of an optimal Absorb implantation technique doesn't improve long-term DOCE or ScT but may mitigate the worse outcome of patients with calcific lesions.


Coronary Artery Disease , Percutaneous Coronary Intervention , Absorbable Implants , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Humans , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Registries , Time Factors , Treatment Outcome
7.
J Cardiovasc Echogr ; 29(2): 65-67, 2019.
Article En | MEDLINE | ID: mdl-31392122

Anomalous coronary arteries (ACAs) are rare but potentially life-threatening abnormalities of coronary circulation. Most of the variants are benign; however, some may lead to myocardial ischemia and/or sudden cardiac arrest. We report the case of a 75-year-old male complaining of exertion chest discomfort. Admission electrocardiogram on presentation showed sinus bradycardia with a slight elevation of ST-T in inferior leads. Troponin levels, however, were normal. Coronary angiography showed an anomalous right coronary artery (RCA) originating from the left main stem without significant stenosis. Cardio-CT confirmed the anomalous origin of the RCA from the left main stem and showed its anomalous course between the aorta and the pulmonary artery. The patient was deemed a candidate for surgery and transferred to a cardiac surgery center. Only the exact definition of the anatomic and clinical features of ACAs may allow the identification of the most appropriate and effective treatment. Multislice computed tomography may play a fundamental role in the diagnosis and treatment of ACAs.

8.
J Cardiovasc Echogr ; 29(1): 23-25, 2019.
Article En | MEDLINE | ID: mdl-31008035

Congenital coronary-pulmonary fistulas (CPFs) are defined as an abnormal direct communication between one or more coronary arteries, with a cardiac or thoracic structure bypassing the capillary network. We report the case of a 73-year-old male, with a history of hypertension, asymptomatic for angina and dyspnea, who was referred for routine clinical control. Echocardiogram unexpectedly showed the presence of diastolic flow from the pulmonary trunk in parasternal short-axis view. Pulsed-wave Doppler confirmed the presence of diastolic flow and displayed the typical coronary flow pattern. Coronary angiography hence showed the presence of dual CPFs originating from the second segment of the left anterior descending coronary and the right coronary arteries. Careful routine Doppler echocardiograph examination may raise the suspicion of CPF in case of otherwise unexplained symptoms and may represent a simple, easy, repeatable tool for the first suspected diagnosis and follow-up of CPFs.

9.
Ann Noninvasive Electrocardiol ; 23(6): e12581, 2018 11.
Article En | MEDLINE | ID: mdl-29984535

BACKGROUND: Persistent ST-segment elevation in acute coronary syndrome is associated with both short and long-term complications. By contrast, there is limited information about ST-elevation and its evolution during takotsubo (stress) cardiomyopathy (TTC). AIM: To evaluate whether persistent downsloping ST-elevation in the early stages of TTC might correlate with short and long-term clinical events. METHODS: One-hundred fifty-eight consecutive subjects with TTC were prospectively enrolled and assessed by electrocardiogram. Patients were classified in two groups according to the presence of downsloping ST-elevation ≥5 mm lasting at least 24 hr ("lambda-wave" ST-elevation group vs. without downsloping ST-elevation) in at least one/two contiguous leads. RESULTS: Five (3.2%) patients, all female with a mean left ventricular ejection fraction 32 ± 5%, were included in the lambda-wave ST-elevation group. These patients were characterized by a higher prevalence of physical stressor (100% vs. 49%, p = 0.04) and higher admission and peak levels of troponin-I levels during hospitalization. Peak of ST-elevation in the lambda-wave ST-elevation group was reached 6 hr after admission and gradually decreased after 24 hr. In-hospital complications were observed in all the patients presenting lambda ST-elevation (100% vs. 23%, p = 0.03, OR: 29.1, p = 0.04); one patient presented endoventricular thrombosis and two died of cardiogenic shock. At long-term follow-up (mean 443 days), adverse events were observed in 80% of patients with lambda-wave ST-elevation (RR of adverse events at follow-up 32, p < 0.01). CONCLUSION: Persistent downsloping lambda-wave ST-elevation during the acute phase of stress cardiomyopathy may be associated with a higher risk of adverse events at short and long-term follow-up.


Cause of Death , Electrocardiography/methods , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/epidemiology , Takotsubo Cardiomyopathy/diagnostic imaging , Takotsubo Cardiomyopathy/epidemiology , Acute Coronary Syndrome/epidemiology , Acute Coronary Syndrome/etiology , Acute Coronary Syndrome/physiopathology , Aged , Cohort Studies , Comorbidity , Echocardiography, Doppler/methods , Female , Hospitals, University , Humans , Italy , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Severity of Illness Index , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Survival Analysis
10.
J Invasive Cardiol ; 30(4): 133-137, 2018 Apr.
Article En | MEDLINE | ID: mdl-29610443

BACKGROUND: Long coronary lesions still remain a challenge, with poor immediate results and suboptimal outcomes when compared to class A/B1 lesions. The presence of overlapped segments of metal struts and polymer might trigger an abnormal inflammatory reaction, resulting in a higher restenosis rate. The aim of our study was to evaluate the safety, feasibility, and cost effectiveness of a 48 mm everolimus-eluting stent (EES) during treatment of very long coronary lesions. METHODS AND RESULTS: The FREIUS study is a prospective data collection of consecutive patients undergoing 48 mm EES implantation in six high-volume European centers. Each patient was matched through a propensity score to a comparable patient treated with two or more second-generation overlapped drug-eluting stents. The primary endpoint was the combined incidence of cardiac death, target-vessel myocardial infarction, and target-lesion revascularization (device-oriented composite endpoint [DOCE]). The secondary endpoints were all-cause death, each individual component of the primary endpoint, and definite/probable stent thrombosis. From January 2014 to April 2015, a total of 218 patients were treated with at least one 48 mm EES and were compared with 218 matched controls. Overall, 9% of patients reached the primary endpoint. Cumulative survival free from DOCE incidence did not differ between the two groups (7% in the cases vs 10.5% in the controls; P=.10). After multivariable analysis, only clinical presentation with myocardial infarction (hazard ratio [HR], 1.8; 95% confidence interval [CI], 1.5-2.1; P=.01) and stent number (HR, 1.4; 95% CI, 1.1-1.8; P=.02) emerged as independent predictors of DOCE. CONCLUSION: The use of 48 mm EES offers a safe and effective strategy for the treatment of very long coronary lesions.


Coronary Thrombosis/surgery , Drug-Eluting Stents , Everolimus/pharmacology , Percutaneous Coronary Intervention/methods , Propensity Score , Aged , Coronary Angiography , Coronary Thrombosis/diagnosis , Coronary Thrombosis/mortality , Europe/epidemiology , Female , Humans , Male , Prospective Studies , Prosthesis Design , Risk Factors , Survival Rate/trends , Treatment Outcome
11.
J Cardiovasc Echogr ; 28(4): 236-238, 2018.
Article En | MEDLINE | ID: mdl-30746328

Papillary fibroelastoma is a rare benign cardiac tumor, second after cardiac myxoma as more frequent cardiac valvular tumor. The therapy is usually based on surgery according to size, mobility, symptoms, and risks of surgery. We report the case of a 67-year old female with transient ischemic attack. Echocardiography showed the presence of a round mobile formation localized on the atrial side of septal leaflets of tricuspid valve, first identified as an endocarditis vegetation. Cardiac magnetic resonance (cMRI) confirmed the presence of the mass and showed an isointense signal in T1-turbo spin echo sequences, hypointense in cine steady-state free precession and in first-pass sequences, and hyperintense in T2 and phase-sensitive inversion recovery with central hypointense core, with a suspected diagnosis of fibroelastoma. The patient underwent cardiac surgery and histology confirmed the presence of fibroelastic tissue with papillary extroflexions compatible with diagnosis of fibroelastoma. The use of cMRI may be useful in the evaluation of the exact position, dimensions, and nature of cardiac masses and fibroelastomas, diagnostic workup, and preliminary assessment before surgery.

12.
Int J Cardiol ; 230: 136-141, 2017 Mar 01.
Article En | MEDLINE | ID: mdl-28038806

BACKGROUND: The study aimed to report the results from an all-comers registry of patients undergoing coronary angioplasty and treated with bioresorbable vascular scaffold (BVS). METHODS: Fifty-five consecutive patients with type B/C coronary lesions according to the AHA classification and treated with BVS were enrolled in the study. The clinical and procedural characteristics of enrolled patients were recorded. Fifty-five consecutive subjects with coronary lesions type B/C treated with everolimus eluting stent (EES) were used as control group. RESULTS: The incidence of adverse events was not statistically significant comparing subjects treated with BVS with those treated with EES. Non significant differences were also found in the follow-up considering the presence of diabetes, multivessel disease, use of more than one stent at the same time, diagnosis (STEMI vs UA/NSTEMI), use of coronary stents in overlapping. The differences were significant considering the type of lesion (Log-Rank p<0.05), stenoses treated in correspondence of a coronary bifurcation (p<0.05), the SYNTAX score (cut off 22) (p<0.001); after multivariable correction for age and gender, however, differences remained significant only for SYNTAX score. CONCLUSIONS: The use of BVS in an all-comers registry of patients undergoing coronary angioplasty on complex coronary lesions is associated with a safety profile comparable to that obtained with EES; the use of BVS in particular conditions, such as very high SYNTAX score, should be further assessed.


Absorbable Implants , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Drug-Eluting Stents , Postoperative Complications/epidemiology , Registries , Aged , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Female , Follow-Up Studies , Humans , Incidence , Italy/epidemiology , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Survival Rate/trends , Treatment Outcome
16.
G Ital Cardiol (Rome) ; 17(10 Suppl 1): 28S-44, 2016 Oct.
Article It | MEDLINE | ID: mdl-27729667

Drug-eluting stents (DES) are the current gold standard for percutaneous treatment of coronary artery disease. However, DES are associated with a non-negligible risk of long-term adverse events related to persistence of foreign material in the coronary artery wall. In addition, DES implantation causes permanent caging of the native vessel, thus impairing normal vasomotricity and the possibility of using non-invasive coronary imaging or preforming subsequent bypass surgery. On the contrary, coronary bioresorbable stents (BRS) may provide temporary mechanical support to coronary wall without compromising the subsequent recovery of normal vascular physiology, and have the potential to prevent late adverse events related to permanent elements. Several types of BRS have been introduced into clinical practice in Europe or are being tested. However, most of available clinical data relate to a single BRS, the Absorb bioresorbable Vascular Scaffold (Absorb BVS) (Abbott Vascular, Santa Clara, CA). Despite encouraging clinical results, no societal guidelines are available on the use of BRS in clinical practice.A panel of Italian expert cardiologists assembled under the auspices of the Italian Society of Interventional Cardiology (SICI-GISE) for comprehensive discussion and consensus development, with the aim to provide recommendations on the use of bioresorbable stents in terms of clinical indications, procedural aspects, post-percutaneous coronary angioplasty pharmacologic treatment and follow-up. Based on current evidence and BRS availability in Italian cath-labs, the panel decided unanimously to provide specific recommendations for the Absorb BVS device. These recommendations do not necessarily extend to other BRS, unless specified, although significant overlap may exist with Absorb BVS, particularly in terms of clinical rationale.


Absorbable Implants , Cardiology , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Italy , Risk Assessment , Risk Factors , Societies, Medical , Time Factors , Tissue Scaffolds
18.
Am J Ther ; 23(4): e1057-9, 2016.
Article En | MEDLINE | ID: mdl-26291591

The Brugada electrocardiogram pattern is characterized by coved-type ST-elevation (>2 mm) in the right precordial leads. We report the case of a 62-year-old man, with bipolar disorder, admitted to the emergency department because of dyspnea and chest discomfort. The patient was on treatment with pregabalin and quetiapine. Unexpectedly, electrocardiogram at admission showed diffuse ST-elevation, more evident in inferior leads, where a Brugada-like pattern was present. The patient underwent coronary angiography with a diagnosis of suspected acute coronary syndrome. Coronary angiography, however, showed mild coronary artery disease not requiring coronary angioplasty. Echocardiography did not reveal left ventricular dysfunction or pericardial effusion. Troponin levels remained normal over serial controls. Eventually, chest radiography showed lung opacities and consolidation suggestive for pneumonia. To the best of our knowledge, this is one of the first cases showing a transient Brugada-like electrocardiogram pattern in inferior leads, probably amplified by the administration of pregabalin and quetiapine.


Anti-Anxiety Agents/adverse effects , Antipsychotic Agents/adverse effects , Electrocardiography/drug effects , Pregabalin/adverse effects , Quetiapine Fumarate/adverse effects , Anti-Anxiety Agents/therapeutic use , Antipsychotic Agents/therapeutic use , Bipolar Disorder/drug therapy , Brugada Syndrome/diagnostic imaging , Coronary Angiography , Echocardiography , Humans , Male , Middle Aged , Pregabalin/therapeutic use , Quetiapine Fumarate/therapeutic use , ST Elevation Myocardial Infarction/diagnostic imaging , Troponin/blood
19.
Am J Cardiol ; 116(5): 705-10, 2015 Sep 01.
Article En | MEDLINE | ID: mdl-26100584

Objective of this study was to assess the clinical performance of bioresorbable vascular scaffold (BVS) compared to everolimus-eluting stent (EES) in subjects with ST-segment elevation myocardial infarction (STEMI). We included all consecutive patients with STEMI who underwent percutaneous coronary intervention (PCI) with BVS implantation in centers participating to the Italian ABSORB Prospective Registry (BVS-RAI) and PCI with EES in the same centers during the same period. The 2 groups were compared. The primary end point was patient-oriented composite end point (POCE) including cardiac death, myocardial infarction, and target lesion revascularization (TLR) at the longest available follow-up. BVS or EES thrombosis at follow-up was also evaluated. Of the 563 patients with STEMI included, 122 received BVS and 441 EES. Procedural success was obtained in 549 (97.5%) cases without significant differences between the 2 groups (BVS 99.3% vs EES 97.0%, p = 0.2). At a median of 220-day (interquartile range 178 to 369) follow-up, no significant differences were observed in terms of POCE (BVS 4.9% vs EES 7.0%, p = 0.4); death (BVS 0.8%, EES 2.0%, p = 0.4), MI (BVS 4.1%, EES 2.0%, p = 0.2), TLR (BVS 4.1%, EES 4.5%, p = 0.8), device thrombosis (BVS 2.5%, EES 1.4%, p = 0.4). All TLR cases were successfully managed with re-PCI in both groups. A propensity matching of the study populations showed no significant differences regarding POCE at the longest available follow-up (odds ratio 0.53, 0.1 to 4.3). In conclusion, in this direct prospective comparison, BVS was associated with similar clinical results compared to EES in the STEMI setting. Larger and adequately powered randomized trials are needed to fully assess the potential clinical benefit of BVS versus the current standard of care in patients with STEMI.


Absorbable Implants , Drug-Eluting Stents , Myocardial Infarction/surgery , Percutaneous Coronary Intervention/methods , Sirolimus/analogs & derivatives , Tissue Scaffolds , Aged , Antineoplastic Agents , Coronary Angiography , Electrocardiography , Everolimus , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/pharmacology , Incidence , Italy/epidemiology , Male , Middle Aged , Myocardial Infarction/diagnosis , Postoperative Complications/epidemiology , Prospective Studies , Prosthesis Design , Sirolimus/pharmacology , Time Factors , Treatment Outcome
...