Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Am J Respir Crit Care Med ; 203(2): 211-220, 2021 01 15.
Article in English | MEDLINE | ID: mdl-32721166

ABSTRACT

Rationale: Usual interstitial pneumonia (UIP) is the defining morphology of idiopathic pulmonary fibrosis (IPF). Guidelines for IPF diagnosis conditionally recommend surgical lung biopsy for histopathology diagnosis of UIP when radiology and clinical context are not definitive. A "molecular diagnosis of UIP" in transbronchial lung biopsy, the Envisia Genomic Classifier, accurately predicted histopathologic UIP.Objectives: We evaluated the combined accuracy of the Envisia Genomic Classifier and local radiology in the detection of UIP pattern.Methods: Ninety-six patients who had diagnostic lung pathology as well as a transbronchial lung biopsy for molecular testing with Envisia Genomic Classifier were included in this analysis. The classifier results were scored against reference pathology. UIP identified on high-resolution computed tomography (HRCT) as documented by features in local radiologists' reports was compared with histopathology.Measurements and Main Results: In 96 patients, the Envisia Classifier achieved a specificity of 92.1% (confidence interval [CI],78.6-98.3%) and a sensitivity of 60.3% (CI, 46.6-73.0%) for histology-proven UIP pattern. Local radiologists identified UIP in 18 of 53 patients with UIP histopathology, with a sensitivity of 34.0% (CI, 21.5-48.3%) and a specificity of 96.9% (CI, 83.8-100%). In conjunction with HRCT patterns of UIP, the Envisia Classifier results identified 24 additional patients with UIP (sensitivity 79.2%; specificity 90.6%).Conclusions: In 96 patients with suspected interstitial lung disease, the Envisia Genomic Classifier identified UIP regardless of HRCT pattern. These results suggest that recognition of a UIP pattern by the Envisia Genomic Classifier combined with HRCT and clinical factors in a multidisciplinary discussion may assist clinicians in making an interstitial lung disease (especially IPF) diagnosis without the need for a surgical lung biopsy.


Subject(s)
Genomics/methods , Idiopathic Pulmonary Fibrosis/diagnosis , Idiopathic Pulmonary Fibrosis/genetics , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Female , Genetic Markers , Humans , Idiopathic Pulmonary Fibrosis/classification , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
3.
Lancet Respir Med ; 7(6): 487-496, 2019 06.
Article in English | MEDLINE | ID: mdl-30948346

ABSTRACT

BACKGROUND: In the appropriate clinical setting, the diagnosis of idiopathic pulmonary fibrosis (IPF) requires a pattern of usual interstitial pneumonia to be present on high-resolution chest CT (HRCT) or surgical lung biopsy. A molecular usual interstitial pneumonia signature can be identified by a machine learning algorithm in less-invasive transbronchial lung biopsy samples. We report prospective findings for the clinical validity and utility of this molecular test. METHODS: We prospectively recruited 237 patients for this study from those enrolled in the Bronchial Sample Collection for a Novel Genomic Test (BRAVE) study in 29 US and European sites. Patients were undergoing evaluation for interstitial lung disease and had had samples obtained by clinically indicated surgical or transbronchial biopsy or cryobiopsy for pathology. Histopathological diagnoses were made by experienced pathologists. Available HRCT scans were reviewed centrally. Three to five transbronchial lung biopsy samples were collected from all patients specifically for this study, pooled by patient, and extracted for transcriptomic sequencing. After exclusions, diagnostic histopathology and RNA sequence data from 90 patients were used to train a machine learning algorithm (Envisia Genomic Classifier, Veracyte, San Francisco, CA, USA) to identify a usual interstitial pneumonia pattern. The primary study endpoint was validation of the classifier in 49 patients by comparison with diagnostic histopathology. To assess clinical utility, we compared the agreement and confidence level of diagnosis made by central multidisciplinary teams based on anonymised clinical information and radiology results plus either molecular classifier or histopathology results. FINDINGS: The classifier identified usual interstitial pneumonia in transbronchial lung biopsy samples from 49 patients with 88% specificity (95% CI 70-98) and 70% sensitivity (47-87). Among 42 of these patients who had possible or inconsistent usual interstitial pneumonia on HRCT, the classifier showed 81% positive predictive value (95% CI 54-96) for underlying biopsy-proven usual interstitial pneumonia. In the clinical utility analysis, we found 86% agreement (95% CI 78-92) between clinical diagnoses using classifier results and those using histopathology data. Diagnostic confidence was improved by the molecular classifier results compared with histopathology results in 18 with IPF diagnoses (proportion of diagnoses that were confident or provisional with high confidence 89% vs 56%, p=0·0339) and in all 48 patients with non-diagnostic pathology or non-classifiable fibrosis histopathology (63% vs 42%, p=0·0412). INTERPRETATION: The molecular test provided an objective method to aid clinicians and multidisciplinary teams in ascertaining a diagnosis of IPF, particularly for patients without a clear radiological diagnosis, in samples that can be obtained by a less invasive method. Further prospective clinical validation and utility studies are planned. FUNDING: Veracyte.


Subject(s)
Algorithms , Biopsy/statistics & numerical data , Idiopathic Pulmonary Fibrosis/diagnosis , Machine Learning/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Aged , Biopsy/methods , Diagnosis, Differential , Female , Humans , Lung/diagnostic imaging , Lung/pathology , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
5.
Ann Thorac Surg ; 104(5): 1501-1508, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28669505

ABSTRACT

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. METHODS: In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. RESULTS: Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. CONCLUSIONS: Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation.


Subject(s)
Bioprosthesis , Prosthesis Design/methods , Prosthesis Failure , Shear Strength/physiology , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Equipment Failure Analysis , Heart Valve Prosthesis , Humans , Materials Testing , Models, Cardiovascular , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
6.
Innovations (Phila) ; 11(2): 138-41, 2016.
Article in English | MEDLINE | ID: mdl-26938172

ABSTRACT

Vascular access for large endovascular devices has evolved as patients have become more complicated and device indications have expanded. As the benefits of catheter-based treatments for aortic aneurysm repair and aortic valve replacement become mainstream, there is a need to address difficult vascular access by developing not only smaller-diameter devices but also creative options for vascular access. We describe direct descending thoracic aortic access during endovascular aneurysm repair, transcatheter aortic valve replacement, and redo mesenteric revascularization in three patients who did not have traditional access options.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Abdominal/surgery , Aortic Valve Stenosis/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Aged , Aged, 80 and over , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Treatment Outcome
8.
Ann Thorac Surg ; 100(2): 723-7, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26234852

ABSTRACT

Vascular complications remain an important consideration when selecting access for delivery of large endovascular devices. With the advent of transcatheter aortic valve replacement, transapical access has become an acceptable technique when transfemoral or direct transaortic access is contraindicated. We report the use of the transapical approach during thoracic aortic endovascular repair in 2 patients, one of which included concomitant delivery of a transcatheter aortic valve replacement device. To our knowledge, this is the first reported case of a hybrid single-stage transcatheter aortic valve replacement and thoracic aortic endovascular repair using transapical access.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Endovascular Procedures/methods , Heart Valve Diseases/surgery , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Aneurysm, Thoracic/complications , Female , Heart Valve Diseases/complications , Humans , Middle Aged
9.
Ann Thorac Surg ; 100(2): 728-30, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26234853

ABSTRACT

Primary cardiac tumors are extremely rare. Although complete surgical resection of malignant primary cardiac tumors results in an improved survival compared with no intervention, the overall prognosis is generally poor, with treatable recurrent primary cardiac sarcomas being extremely rare. We report a patient with a recurrent primary cardiac sarcoma obstructing the left atrium managed with radical cardiac resection, including right pneumonectomy, with 21-month postprocedural survival.


Subject(s)
Heart Neoplasms/surgery , Neoplasm Recurrence, Local/surgery , Sarcoma/surgery , Cardiac Surgical Procedures , Humans , Male , Middle Aged , Pneumonectomy
10.
Catheter Cardiovasc Interv ; 86(4): 768-72, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25640823

ABSTRACT

Thoracic endovascular aortic repair (TEVAR) of acute ascending aortic pathology is feasible; however, the unique features of this aortic segment in addition to access challenges restricts its use to a select, high-risk subset of patients. With the advent of TAVR, large device delivery using transapical access has become a well-defined technique. We report a patient with critical aortic stenosis and an acute ascending aortic penetrating ulcer with tamponade managed successfully utilizing transapical TAVR and TEVAR. To our knowledge, this is the first reported case of a hybrid single-stage TAVR and ascending aortic TEVAR using transapical access.


Subject(s)
Aorta/surgery , Aortic Diseases/surgery , Aortic Valve Stenosis/surgery , Blood Vessel Prosthesis Implantation/methods , Transcatheter Aortic Valve Replacement/methods , Ulcer/surgery , Aged, 80 and over , Aortic Diseases/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortography/methods , Blood Vessel Prosthesis , Cardiac Catheterization/methods , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/surgery , Combined Modality Therapy , Critical Illness , Echocardiography, Transesophageal/methods , Endovascular Procedures/methods , Female , Fluoroscopy/methods , Follow-Up Studies , Humans , Imaging, Three-Dimensional , Prosthesis Design , Tomography, X-Ray Computed/methods , Treatment Outcome , Ulcer/diagnostic imaging
11.
Ann Vasc Surg ; 29(2): 362.e3-4, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25462540

ABSTRACT

Radial artery pseudoaneurysms occur infrequently and are most commonly associated with medical interventions such as arterial lines or cardiac catheterization procedures. Animal bites, particularly cat bites, as a cause for radial artery pseudoaneurysms are extremely rare with only 1 previously reported case in the literature. A unique case of digital micro emboli from a radial artery pseudoaneurysm caused by a cat bite to the wrist is presented.


Subject(s)
Aneurysm, False/surgery , Bites and Stings/complications , Radial Artery/injuries , Aneurysm, False/etiology , Animals , Cats , Female , Humans , Middle Aged , Radial Artery/surgery , Wrist Injuries/etiology
SELECTION OF CITATIONS
SEARCH DETAIL