Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
ASAIO J ; 70(1): 53-61, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-37934718

A restrictive fluid strategy is recommended in patients with acute respiratory distress syndrome (ARDS) managed with venovenous extracorporeal membrane oxygenation (VV ECMO). However, there are no established predictors for preload responsiveness in these patients. In 20 ARDS patients managed with VV ECMO, transesophageal echocardiography was used to repeatedly evaluate dynamic parameters of the left (velocity and stroke volume variation) and right ventricular outflow tract (velocity [respiratory variations of the maximal Doppler velocity in the truncus pulmonalis {ΔV max TP}] and velocity time integral [respiratory variation of the velocity time integral measured in the truncus pulmonalis {ΔVTI_TP}] variation in the truncus pulmonalis), the diameter variation in the superior and inferior vena cava and stroke volume variation measured by pulse contour analysis (SVV_PCA). Patients were categorized as responders and nonresponders according to an increase in stroke volume measured by echocardiography during a Passive Leg Raise Test with a cutoff value ≥10%. The final analysis includes 86 measurements. Predictive values for preload responsiveness were found for ΔV max TP (area under the curve [AUC] of 0.64), ΔVTI_TP (AUC 0.67), and SVV_PCA (AUC 0.74). In conclusion, SVV_PCA and, to a lesser extent, ΔV max TP and ΔVTI_TP are the most accurate parameters to predict preload responsiveness in ARDS patients managed with VV ECMO. Transesophageal echocardiography offers no advantages over pulse contour analysis for predicting preload responsiveness and provides only intermittent monitoring and assessment.


Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Humans , Hemodynamics , Prospective Studies , Fluid Therapy , Stroke Volume , Respiratory Distress Syndrome/diagnostic imaging , Respiratory Distress Syndrome/therapy
2.
Ann Intensive Care ; 11(1): 101, 2021 Jul 02.
Article En | MEDLINE | ID: mdl-34213674

BACKGROUND: We tested the effect of different blood flow levels in the extracorporeal circuit on the measurements of cardiac stroke volume (SV), global end-diastolic volume index (GEDVI) and extravascular lung water index derived from transpulmonary thermodilution (TPTD) in 20 patients with severe acute respiratory distress syndrome (ARDS) treated with veno-venous extracorporeal membrane oxygenation (ECMO). METHODS: Comparative SV measurements with transesophageal echocardiography and TPTD were performed at least 5 times during the treatment of the patients. The data were interpreted with a Bland-Altman analysis corrected for repeated measurements. The interchangeability between both measurement modalities was calculated and the effects of extracorporeal blood flow on SV measurements with TPTD was analysed with a linear mixed effect model. GEDVI and EVLWI measurements were performed immediately before the termination of the ECMO therapy at a blood flow of 6 l/min, 4 l/min and 2 l/min and after the disconnection of the circuit in 7 patients. RESULTS: 170 pairs of comparative SV measurements were analysed. Average difference between the two modalities (bias) was 0.28 ml with an upper level of agreement of 40 ml and a lower level of agreement of -39 ml within a 95% confidence interval and an overall interchangeability rate between TPTD and Echo of 64%. ECMO blood flow did not influence the mean bias between Echo and TPTD (0.03 ml per l/min of ECMO blood flow; p = 0.992; CI - 6.74 to 6.81). GEDVI measurement was not significantly influenced by the blood flow in the ECMO circuit, whereas EVLWI differed at a blood flow of 6 l/min compared to no ECMO flow (25.9 ± 10.1 vs. 11.0 ± 4.2 ml/kg, p = 0.0035). CONCLUSIONS: Irrespectively of an established ECMO therapy, comparative SV measurements with Echo and TPTD are not interchangeable. Such caveats also apply to the interpretation of EVLWI, especially with a high blood flow in the extracorporeal circulation. In such situations, the clinician should rely on other methods of evaluation of the amount of lung oedema with the haemodynamic situation, vasopressor support and cumulative fluid balance in mind. TRIAL REGISTRATION: German Clinical Trials Register (DRKS00021050). Registered 03/30/2020 https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00017237.

...