Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Radiat Prot Dosimetry ; 167(1-3): 223-7, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26065703

ABSTRACT

In order to explain the distribution of natural radiation level in the Asia, in situ measurements of dose rate in air due to terrestrial gamma radiation have been conducted in a total of 21 islands that belong to Ryukyu Islands (Ryukyu Archipelago), subtropical rejoin of southwest Japan. Car-borne surveys have also been carried out in Okinawa-jima, the biggest island of the archipelago. Based on the results for these measurements, arithmetic mean, the maximum and the minimum of the dose rates at 1 m in height from the unpaved soil ground in the archipelago were estimated to be 47, 165 and 8 nGy h(-1), respectively. A comparative study of car-borne data obtained prior to and subsequent to the 2011 Fukushima nuclear accident, as for Okinawa-jima, indicated that the nuclear accident has no impact on the environmental radiation at the present time.


Subject(s)
Fukushima Nuclear Accident , Gamma Rays , Radiation Monitoring/methods , Radioactive Fallout/analysis , Soil Pollutants, Radioactive/administration & dosage , Background Radiation , Islands , Japan , Radiation Dosage , Radiation Monitoring/instrumentation , Scintillation Counting , Tropical Climate
2.
Clin Chem ; 40(11 Pt 1): 2006-12, 1994 Nov.
Article in English | MEDLINE | ID: mdl-7955369

ABSTRACT

We have developed a flow-injection system with colorimetric detection to measure 1,5-anhydro-D-glucitol in serum. Serum samples are directly and serially injected into a clean-up column every 3.5 min to remove interferences before the enzymatic reaction. 1,5-Anhydro-D-glucitol, after being passed through the column, is oxidized by immobilized pyranose oxidase (EC 1.1.3.10), and the hydrogen peroxide produced reacts with the chromogen substrate in the presence of immobilized horseradish peroxidase (EC 1.11.1.7) to form Bindshedler's Green. The detection limit was 1.2 mumol/L (1.2 pmol). The correlation between results obtained with the present system (y) and gas chromatography-mass spectrometry (GC-MS) (x) in samples containing < 30 mumol/L 1,5-anhydro-D-glucitol, including many samples from patients with diabetes mellitus, was y = 0.975x-0.111 mumol/L (r = 0.997), which was superior to that obtained between the enzymatic and GC-MS methods. Our system needs only to be set up; it runs without any manual pretreatment, assays 17 samples/h, and shows imprecision (CV) of < 2%.


Subject(s)
Autoanalysis/methods , Deoxyglucose/blood , Flow Injection Analysis/methods , Autoanalysis/statistics & numerical data , Carbohydrate Dehydrogenases/metabolism , Colorimetry/methods , Colorimetry/statistics & numerical data , Diabetes Mellitus/blood , Flow Injection Analysis/statistics & numerical data , Gas Chromatography-Mass Spectrometry , Horseradish Peroxidase , Humans , Hydrogen Peroxide/metabolism , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL