Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 83(10): 10E106, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126928

ABSTRACT

Ultra fast x-ray streak cameras are a staple for time resolved x-ray measurements. There is a need for a ten inch manipulator (TIM) based streak camera that can be fielded in a newer large scale laser facility. The Lawrence Livermore National Laboratory ultra fast streak camera's drive electronics have been upgraded and redesigned to fit inside a TIM tube. The camera also has a new user interface that allows for remote control and data acquisition. The system has been outfitted with a new sensor package that gives the user more operational awareness and control.

2.
Rev Sci Instrum ; 79(10): 10E303, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044465

ABSTRACT

A novel time, space, and energy-resolved x-ray spectrometer has been developed which produces, in a single snapshot, a broadband and relatively calibrated spectrum of the x-ray emission from a high-energy density laboratory plasma. The opacity zipper spectrometer (OZSPEC-1) records a nearly continuous spectrum for x-ray energies from 240 to 5800 eV in a single shot. The second-generation OZSPEC-2, detailed in this work, records fully continuous spectra on a single shot from any two of these three bands: 270-650, 660-1580, and 1960-4720 eV. These instruments thus record thermal and line radiation from a wide range of plasmas. These instruments' single-shot bandwidth is unmatched in a time-gated spectrometer; conversely, other broadband instruments are either time-integrated (using crystals or gratings), lack spectral resolution (diode arrays), or cover a lower energy band (gratings). The OZSPECs are based on the zipper detector, a large-format (100x35 mm) gated microchannel plate detector, with spectra dispersed along the 100 mm dimension. OZSPEC-1 and -2 both use elliptically bent crystals of OHM, RAP, and/or PET. Individual spectra are gated in 100 ps. OZSPEC-2 provides one-dimensional spatial imaging with 30-50 microm resolution over a 1500 microm field of view at the source. The elliptical crystal design yields broad spectral coverage with resolution E/DeltaE>500, strong rejection of hard x-ray backgrounds, and negligible source broadening for extended sources. Near-term applications include plasma opacity measurements, detailed spectra of inertial fusion Hohlraums, and laboratory astrophysics experiments.

3.
Rev Sci Instrum ; 79(10): 10F550, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044692

ABSTRACT

We present a platform for producing long plasma channels suitable for guiding lasers over several centimeters by applying magnetic fields to limit the radial heat flux from a preforming laser beam. The resulting density gradient will be used as an optical plasma waveguide. The plasma conditions have been chosen to be consistent with the requirements for laser wakefield acceleration where multi-GeV electrons are predicted. A detailed description of the system used to produce the high (5 T) magnetic fields and initial results that show a 5 cm long plasma column are discussed.

4.
Percept Mot Skills ; 58(2): 591-601, 1984 Apr.
Article in English | MEDLINE | ID: mdl-6739249

ABSTRACT

40 schizophrenic subjects, divided into paranoid/non-paranoid categories and 14 normal controls were presented a task which involved making "same-different" judgments during random presentations of a series of visual comparison stimuli with a standard which represented the midpoint of the stimulus continuum. Using Sternberg's Choice RT paradigm for studying the locus of cognitive deficit, difficulty at the response-selection stage was manipulated while holding other stages constant. It was predicted that paranoids would have shorter RTs at easy decision points and longer RTs at difficult decision points relative to non-paranoids. The directions of the differences were as predicted but did not attain statistical significance. Both schizophrenic groups, compared to normals, made significantly fewer "same" responses on those trials where the comparison and standard were most similar.


Subject(s)
Decision Making , Schizophrenia, Paranoid/psychology , Schizophrenic Psychology , Color Perception , Female , Humans , Male , Reaction Time
5.
Percept Mot Skills ; 50(1): 331-6, 1980 Feb.
Article in English | MEDLINE | ID: mdl-7367186

ABSTRACT

15 autistic children were matched with normals on the Beery-Buktenica Developmental Test of Visual-motor Integration. The two groups were subsequently compared on ability to (1) increase geometric figure-copying performance using additional information provided during subsequent trials, (2) make figure-ground resolutions, (3) perform a fine motor integration task, and (4) cope with background interference while responding on the Developmental Test of Visual-motor Integration. The primary deficit observed in the autistic subjects appeared to be defective monitoring of the motor response.


Subject(s)
Autistic Disorder/complications , Cognition , Motor Skills , Visual Perception , Adolescent , Attention , Child , Child, Preschool , Form Perception , Humans
6.
Percept Mot Skills ; 47(3 Pt 2): 1191-4, 1978 Dec.
Article in English | MEDLINE | ID: mdl-745896

ABSTRACT

To assess the relative influence of decisional ambiguity and response uncertainty on task difficulty, a pattern discrimination task was presented to 60 college undergraduates. The comparison stimuli were nine 20 X 20 matrices of randomly assigned black and white squares, with percent of black squares varying evenly from 10% to 90%. The standard contained 50% black squares. In a low-response uncertainty condition there were two response categories, and five in a high uncertainty condition. It was hypothesized that decisional ambiguity should be greatest at the boundaries between categories. The results suggested that decisional ambiguity was the critical factor determining judgment difficulty.


Subject(s)
Decision Making , Form Perception , Pattern Recognition, Visual , Reaction Time , Humans , Judgment
8.
Imprint ; 18(3): 11 passim, 1971.
Article in English | MEDLINE | ID: mdl-5207535

Subject(s)
California , Disasters , Nursing
SELECTION OF CITATIONS
SEARCH DETAIL