Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
J Cardiothorac Surg ; 19(1): 59, 2024 Feb 05.
Article En | MEDLINE | ID: mdl-38317185

BACKGROUNDS: The internal fixation for rib fracture with single-operation-port (two ports) complete video-assisted thoracoscopic surgery (VATS) is a promising surgical approach for treating multiple rib fractures. The study aimed to investigate the minimally invasive surgical procedure's clinical effect in treating multiple rib fractures. METHODS: Seventy-three patients with multiple rib fractures were divided into two groups according to surgical procedure. In the study group, 42 patients were operated on with the internal fixation of rib fracture with single-operation-port complete VATS. In the control group, this study performed the open operative internal fixation for rib fracture with traditional thoracotomy on 31 patients. The surgical-related indexes were retrospectively analyzed. These included the operative time, the intraoperative blood loss, the drainage amount of the chest tube, the placement time of the chest tube, the postoperative hospital stay, the incidence of postoperative complications, the imaging efficacy of rib fixation of rib fractures, and visual analog scale of pain scoring (VAS scoring). RESULTS: There was no difference in the operative time between the study and control groups (P = 0.806). The intraoperative blood loss, the chest tube drainage amount, the chest tube placement time, the postoperative hospital stay, and the incidence of postoperative complications in the study group were lower than those in the control group (P < 0.05). There was no significant difference in the imaging efficacy of rib fixation of rib fractures between the two groups (P = 0.806). VAS scores in the study group on the seventh postoperative day were significantly reduced compared with the control group (P = 0.026). CONCLUSION: The internal fixation for rib fractures with single-operation-port complete VATS is a feasible, safe, simple, and minimally invasive surgical procedure to treat multiple rib fractures, which is worthy of clinical application.


Rib Fractures , Thoracic Surgery, Video-Assisted , Humans , Thoracic Surgery, Video-Assisted/methods , Rib Fractures/surgery , Retrospective Studies , Blood Loss, Surgical , Fracture Fixation, Internal/methods , Postoperative Complications
2.
Sensors (Basel) ; 20(2)2020 Jan 10.
Article En | MEDLINE | ID: mdl-32284514

Magnetic rings are the most widely used magnetic material product in industry. The existing manual defect detection method for magnetic rings has high cost, low efficiency and low precision. To address this issue, a magnetic ring multi-defect stereo detection system based on multi-camera vision technology is developed to complete the automatic inspection of magnetic rings. The system can detect surface defects and measure ring height simultaneously. Two image processing algorithms are proposed, namely, the image edge removal algorithm (IERA) and magnetic ring location algorithm (MRLA), separately. On the basis of these two algorithms, connected domain filtering methods for crack, fiber and large-area defects are established to complete defect inspection. This system achieves a recognition rate of 100% for defects such as crack, adhesion, hanger adhesion and pitting. Furthermore, the recognition rate for fiber and foreign matter defects attains 92.5% and 91.5%, respectively. The detection speed exceeds 120 magnetic rings per minutes, and the precision is within 0.05 mm. Both precision and speed meet the requirements of real-time quality inspection in actual production.

...