Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Mater Interfaces ; 13(16): 19476-19486, 2021 Apr 28.
Article in English | MEDLINE | ID: mdl-33852293

ABSTRACT

Novel ways to track and verify items of a high value or security is an ever-present need. Taggants made from deoxyribonucleic acid (DNA) have several advantageous properties, such as high information density and robust synthesis; however, existing methods require laboratory techniques to verify, limiting applications. Here, we leverage DNA nanotechnology to create DNA taggants that can be validated in the field in seconds to minutes with a simple equipment. The system is driven by toehold-mediated strand-displacement reactions where matching oligonucleotide sequences drive the generation of a fluorescent signal through the potential energy of base pairing. By pooling different "input" oligonucleotide sequences in a taggant and spatially separating "reporter" oligonucleotide sequences on a paper ticket, unique, sequence-driven patterns emerge for different taggant formulations. Algorithmically generated oligonucleotide sequences show no crosstalk and ink-embedded taggants maintain activity for at least 99 days at 60 °C (equivalent to nearly 2 years at room temperature). The resulting fluorescent signals can be analyzed by the eye or a smartphone when paired with a UV flashlight and filtered glasses.


Subject(s)
DNA/genetics , Nanotechnology/methods , Base Sequence , Paper , Reproducibility of Results , Time Factors
2.
Biotechnol Lett ; 28(11): 823-9, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16786248

ABSTRACT

Staphylococcal enterotoxin A (SEA) is among the most potent of the growing list of known enterotoxins produced by Staphylococcus aureus. SEA, a 27 kDa monomeric protein, is encoded by the entA gene. We have developed two real-time fluorogenic PCR assays for the detection of nucleic acid sequences in entA. The assays are useful in detecting and identifying strains of S. aureus that produce SEA and can serve a confirmatory role in determining the presence of SEA in food samples. The assays were tested in two real-time PCR formats, using either dye-labeled DNA probes corresponding to each primer set that are degraded by the 5' exonuclease activity of Taq polymerase, or a PCR master mix that contains the DNA-binding dye SYBR Green. In both formats the assays have a limit of detection of between 1 and 13 copies of a S. aureus genome that contains a copy of entA. Neither assay cross-reacted with genomic DNA isolated from other strains of S. aureus or other species.


Subject(s)
Bacteriological Techniques/methods , Enterotoxins/genetics , Polymerase Chain Reaction/methods , Staphylococcus aureus/genetics , Enterotoxins/isolation & purification , Fluorescent Dyes , Food Microbiology , Molecular Sequence Data , Sensitivity and Specificity
3.
Appl Environ Microbiol ; 72(1): 478-83, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16391081

ABSTRACT

Bacteriophage MS2 is used in place of pathogenic viruses in a wide variety of studies that range from testing of compounds for disinfecting surfaces to studying environmental transport and fate of pathogenic viruses in groundwater. MS2 is also used as a pathogen simulant in the research, development, and testing (including open air tests) of methods, systems, and devices for the detection of pathogens in both the battlefield and homeland defense settings. PCR is often used as either an integral part of such detection systems or as a reference method to assess the sensitivity and specificity of microbial detection. To facilitate the detection of MS2 by PCR, we describe here a set of real-time fluorogenic reverse transcription-PCR assays. The sensitivity of the assays (performed with primer pairs and corresponding dye-labeled probes) ranged from 0.4 to 40 fg of MS2 genomic RNA (200 to 20,000 genome equivalents). We also demonstrate the usefulness of the primer pairs in assays without dye-labeled probe that included the DNA-binding dye SYBR green. None of the assays gave false-positive results when tested against 400 pg of several non-MS2 nucleic acid targets.


Subject(s)
Fluorescent Dyes/metabolism , Levivirus/isolation & purification , Reverse Transcriptase Polymerase Chain Reaction/methods , DNA Primers , Levivirus/genetics , RNA, Viral/analysis , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...