Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters











Publication year range
1.
Biomed Opt Express ; 15(9): 5180-5198, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39296403

ABSTRACT

The skin, being the body's largest organ, plays a pivotal role in protecting the body against dangerous external factors. The maintenance of adequate hydration levels is essential for the skin to fulfill this protective function. However, skin hydration depends upon different biophysical factors and lifestyles, such as ethnicity, sex, age, water consumption, and many more. Consequently, methods to assess skin hydration in a precise and non-invasive manner are in high demand. In this paper, using a portable and handheld terahertz (THz) probe, we systematically examine the correlation between diverse biophysical factors and skin hydration profile in a population exceeding 300 participants. Through comparative analysis of THz light reflected from the skin against a dielectric model, we successfully extracted the thickness and hydration percentage of the outermost layer of the epidermis, the stratum corneum (SC). Our findings indicate that SC hydration and thickness are associated with variables such as daily water consumption, age, drinking coffee, and exercise. Additionally, our measurements reveal distinctions in the skin's hydration properties concerning susceptibility to UV-induced effects by bringing in the Fitzpatrick skin types. This THz-based technique holds the potential for facile integration into clinical settings for the evaluation and diagnosis of various skin-related conditions.

2.
Biomed Opt Express ; 14(3): 1146-1158, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36950242

ABSTRACT

Transdermal drug delivery (TDD) has been widely used in medical treatments due to various advantages, including delivering drugs at a consistent rate. However, variations in skin hydration can have a significant effect on the permeability of chemicals. Therefore, it is essential to study the changes in skin hydration induced by TDD patches for better control of the delivery rate. In this work, in vivo terahertz (THz) spectroscopy is conducted to quantitatively monitor human skin after the application of patches with different backing materials and propylene glycol concentrations. Changes in skin hydration and skin response to occlusion induced by other patches are investigated and compared. Our work demonstrates the potential application of in vivo THz measurements in label-free, non-invasive evaluation of transdermal patches on human skin and further reveals the mechanism behind the effect.

3.
Opt Express ; 30(11): 18079-18089, 2022 May 23.
Article in English | MEDLINE | ID: mdl-36221615

ABSTRACT

Terahertz time-domain spectroscopy (THz-TDS) has shown promise in biomedical sample characterization and high characterization sensitivity is in demand due to the thin-film (TF) feature of the sample. This paper proposes an optimized multilayer structure for sensitive characterization of TF aqueous solutions in reflection THz-TDS. Theoretical simulations are conducted for structural optimization and the 75 µm window-sample-mirror structure displays the best sensitivity compared to other sandwich structures and traditional THz measurement geometries. 0-20% TF glucose solutions are then measured; and a spectral peak introduced by the proposed structure is observed to result in the high sensitivity. Our work provides a new way of customizing multilayer structure for THz thin-film characterization.


Subject(s)
Terahertz Spectroscopy , Glucose , Terahertz Spectroscopy/methods , Water
4.
Sci Rep ; 11(1): 3005, 2021 Feb 04.
Article in English | MEDLINE | ID: mdl-33542299

ABSTRACT

In this work we demonstrate a triangular surface lens (axicon) operating at frequencies between 350 and 450 GHz using parallel-plate-waveguide technology. The proposed axicon offers longer focal depth characteristics compared to conventional plastic lenses, surpassing common TPX lenses by one order of magnitude. Additionally, due to the triangular surface of the axicon, this device is able to focus THz radiation onto smaller areas than TPX lenses, enhancing the resolution characteristics of THz imaging systems. The frequency range of operation of the proposed axicon can be easily tuned by changing the space between plates, making this approach a very attractive candidate for low-cost, robust and easy to assemble solutions for the next generation of active THz devices.

5.
Opt Lett ; 45(5): 1208-1211, 2020 Mar 01.
Article in English | MEDLINE | ID: mdl-32108807

ABSTRACT

In this Letter, we report a broadband frequency/polarization demultiplexer based on parallel-plate waveguides (PPWGs) for terahertz (THz) frequencies. The fabrication and experimental validation of this polarization sensitive demultiplexer is demonstrated for the range from 0.2 to 1 THz. Upgrading the demultiplexer by adding a second demultiplexer stage, a fifty-fifty amplitude splitter is also demonstrated in the same frequency range. The multiplexer is based on a stainless-steel traveling-wave antenna, exhibiting strong mechanical robustness. This unique device exhibits three splitting mechanisms in the same device: amplitude, polarization, and frequency splitting. This is a significant improvement for the next generation of THz passive components for communication purposes.

6.
Opt Lett ; 44(9): 2149-2152, 2019 May 01.
Article in English | MEDLINE | ID: mdl-31042170

ABSTRACT

We propose a multilayer geometry to characterize thin-film samples in reflection terahertz time domain spectroscopy. Theory indicates that this geometry has higher sensitivity compared to ordinary transmission or reflection geometries when characterizing both low- and high-absorption samples. Pure water and water-ethanol mixtures are measured to verify the characterization accuracy of the proposed geometry and its capability to measure trace liquids. Paraffin-embedded oral cancer tissue is imaged to further show how the proposed geometry enhances the sensitivity for solid low-absorptive films.


Subject(s)
Histocytological Preparation Techniques , Mouth Neoplasms/pathology , Terahertz Spectroscopy/methods , Water , Humans , Paraffin Embedding
7.
Opt Express ; 27(8): 11635-11641, 2019 Apr 15.
Article in English | MEDLINE | ID: mdl-31053006

ABSTRACT

In this paper, we numerically and experimentally demonstrate the inverse polarization effect in three-dimensional (3-D) printed polarizers for the frequency range of 0.5 - 2.7 THz. The polarizers simply consist of 3-D printed strip lines of conductive polylactic acid (CPLA, Proto-Pasta) and do not require a substrate or any further metallic deposition. The experimental and numerical results show that the proposed structure acts as a broadband polarizer between the range of 0.3 THz to 2.7 THz, in which the inverse polarization effect is clearly seen for frequencies above 0.5 THz. In the inverse polarization effect, the transmission of the transverse electric (TE) component exceeds that of the TM component, in contrast to the behavior of a typical wire-grid polarizer. We show how the performance of the polarizers depends on the spacing and thickness of the CPLA structure; extinction ratios higher than 20 dB are achieved. This is the first report using CPLA to fabricate THz polarizers, demonstrating the potential of using conductive polymers to design THz components efficiently and robustly.

8.
Opt Express ; 26(3): 3702-3708, 2018 Feb 05.
Article in English | MEDLINE | ID: mdl-29401897

ABSTRACT

In this paper we theoretically and experimentally demonstrate a stepped-refractive-index convergent lens made of a parallel stack of metallic plates for terahertz frequencies based on artificial dielectrics. The lens consist of a non-uniformly spaced stack of metallic plates, forming a mirror-symmetric array of parallel-plate waveguides (PPWGs). The operation of the device is based on the TE1 mode of the PPWG. The effective refractive index of the TE1 mode is a function of the frequency of operation and the spacing between the plates of the PPWG. By varying the spacing between the plates, we can modify the local refractive index of the structure in every individual PPWG that constitutes the lens producing a stepped refractive index profile across the multi stack structure. The theoretical and experimental results show that this structure is capable of focusing a 1 cm diameter beam to a line focus of less than 4 mm for the design frequency of 0.18 THz. This structure shows that this artificial-dielectric concept is an important technology for the fabrication of next generation terahertz devices.

9.
Sci Rep ; 7: 42124, 2017 02 06.
Article in English | MEDLINE | ID: mdl-28165050

ABSTRACT

Most people with diabetes suffer some deterioration of the feet. Diabetic foot syndrome causes ulceration in about 15% of cases and such deterioration leads to amputation in about 2.5% of diabetic patients, diminishing their quality of life and generating extraordinary costs for patients and public health systems. Currently, there is no objective method for the detection of diabetic foot syndrome in its early stages. We propose terahertz imaging as a method for the evaluation of such deterioration. This screening method could aid the prevention and medical treatment of this condition in the future.


Subject(s)
Diabetic Foot/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Terahertz Imaging/methods , Adult , Amputation, Surgical/statistics & numerical data , Case-Control Studies , Diabetic Foot/economics , Diabetic Foot/psychology , Diabetic Foot/surgery , Female , Health Care Costs , Humans , Male , Middle Aged , Prognosis , Quality of Life/psychology , Risk Factors , Syndrome , Terahertz Imaging/instrumentation
10.
Appl Opt ; 53(33): 7872-6, 2014 Nov 20.
Article in English | MEDLINE | ID: mdl-25607861

ABSTRACT

We use terahertz time-domain spectroscopy, combined with effective-medium theory, to measure the moisture content and thickness of leather simultaneously. These results demonstrate that this method could become a standard quality control test for the industrial tanning process.

SELECTION OF CITATIONS
SEARCH DETAIL