Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Magn Reson ; 265: 197-9, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26927028

ABSTRACT

Recently the spin-lattice relaxation time T1 of hyperpolarized (HP)-(129)Xe was significantly improved by using uncoated and Rb-free storage vessels of GE180 glass. For these cells, a simple procedure was established to obtain reproducible wall relaxation times of about 18 h. Then the limiting relaxation mechanism in pure Xe is due to the coupling between the nuclear spins and the angular momentum of the Xe-Xe van-der-Waals-molecules. This mechanism can be significantly reduced by using different buffer gases of which CO2 was discovered to be the most efficient so far. From these values, it was estimated that for a 1:1 mixture of HP-Xe with CO2 a longitudinal relaxation time of about 7 h can be expected, sufficient to transport HP-Xe from a production to a remote application site. This prediction was verified for such a mixture at a total pressure of about 1 bar in a 10 cm glass cell showing a storage time of T1≈9 h (for T1(wall)=(34±9) h) which was transported inside a magnetic box over a distance of about 200 km by car.

2.
Magn Reson Med ; 74(3): 884-93, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25213218

ABSTRACT

PURPOSE: MRI of lung airspaces using gases with MR-active nuclei ((3) He, (129) Xe, and (19) F) is an important area of research in pulmonary imaging. The volume-controlled administration of gas mixtures is important for obtaining quantitative information from MR images. State-of-the-art gas administration using plastic bags (PBs) does not allow for a precise determination of both the volume and timing of a (3) He bolus. METHODS: A novel application unit (AU) was built according to the requirements of the German medical devices law. Integrated spirometers enable the monitoring of the inhaled gas flow. The device is particularly suited for hyperpolarized (HP) gases (e.g., storage and administration with minimal HP losses). The setup was tested in a clinical trial (n = 10 healthy volunteers) according to the German medicinal products law using static and dynamic ventilation HP-(3) He MRI. RESULTS: The required specifications for the AU were successfully realized. Compared to PB-administration, better reproducibility of gas intrapulmonary distribution was observed when using the AU for both static and dynamic ventilation imaging. CONCLUSION: The new AU meets the special requirements for HP gases, which are storage and administration with minimal losses. Our data suggest that gas AU-administration is superior to manual modes for determining the key parameters of dynamic ventilation measurements.


Subject(s)
Contrast Media/administration & dosage , Helium/administration & dosage , Isotopes/administration & dosage , Lung/physiology , Magnetic Resonance Imaging/methods , Pulmonary Ventilation/physiology , Adult , Contrast Media/chemistry , Contrast Media/therapeutic use , Equipment Design , Helium/chemistry , Helium/therapeutic use , Humans , Isotopes/chemistry , Isotopes/therapeutic use , Magnetic Resonance Imaging/instrumentation , Male
3.
Phys Rev Lett ; 113(18): 188902, 2014 Oct 31.
Article in English | MEDLINE | ID: mdl-25396399
4.
Phys Rev Lett ; 112(11): 110801, 2014 Mar 21.
Article in English | MEDLINE | ID: mdl-24702343

ABSTRACT

We report on the search for a CPT- and Lorentz-invariance-violating coupling of the He3 and Xe129 nuclear spins (each largely determined by a valence neutron) to posited background tensor fields that permeate the Universe. Our experimental approach is to measure the free precession of nuclear spin polarized He3 and Xe129 atoms in a homogeneous magnetic guiding field of about 400 nT using LTC SQUIDs as low-noise magnetic flux detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the colocated spin samples. As a result we obtain an upper limit on the equatorial component of the background field interacting with the spin of the bound neutron b(⊥)(n)<8.4 × 10(-34) GeV (68% C.L.). Our result improves our previous limit (data measured in 2009) by a factor of 30 and the world's best limit by a factor of 4.

5.
Phys Rev Lett ; 111(10): 100801, 2013 Sep 06.
Article in English | MEDLINE | ID: mdl-25166647

ABSTRACT

We search for a spin-dependent P- and T-violating nucleon-nucleon interaction mediated by light pseudoscalar bosons such as axions or axionlike particles. We employ an ultrasensitive low-field magnetometer based on the detection of free precession of colocated 3He and 129Xe nuclear spins using SQUIDs as low-noise magnetic flux detectors. The precession frequency shift in the presence of an unpolarized mass was measured to determine the coupling of pseudoscalar particles to the spin of the bound neutron. For boson masses between 2 and 500 µeV (force ranges between 3×1(-4) m and 10(-1) m) we improved the laboratory upper bounds by up to 4 orders of magnitude.

6.
Magn Reson Med ; 67(6): 1758-63, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22135249

ABSTRACT

We have developed the means to recycle (3) He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized (3) He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1-2% of (3) He, depending on the amount administered and the number of breaths collected to wash out the (3) He gas from the lungs. (3) He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled (3) He gas features high purity, which is required for repolarization by metastability exchange optical pumping. At present, we achieve a collection efficiency of 80-84% for exhaled gas from healthy volunteers and cryogenic separation efficiency of 95%.


Subject(s)
Contrast Media/isolation & purification , Helium/isolation & purification , Lung/physiology , Magnetic Resonance Imaging/instrumentation , Recycling/methods , Administration, Inhalation , Equipment Design , Equipment Failure Analysis , Exhalation , Helium/administration & dosage , Humans , Isotopes/administration & dosage , Isotopes/isolation & purification , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/isolation & purification
7.
J Magn Reson ; 204(1): 37-49, 2010 May.
Article in English | MEDLINE | ID: mdl-20211572

ABSTRACT

We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1T. With fields of about 1mT, such boxes are being used for shipping spin-polarized (3)He worldwide for MRI purposes. For current powered boxes, we present concepts and realizations of uniaxial and tri-axial shielded magnetic fields which are homogeneous on the level of 10(-4) within the entire shielded volume. This is achieved by inserting tightly fitting solenoids into a box from soft-magnetic material. The flexible tri-axial solution suits in particular laboratory applications, e.g. for establishing a spin quantization axis.


Subject(s)
Electromagnetic Fields , Magnetics , Models, Theoretical , Computer Simulation , Spin Labels
8.
Phys Rev Lett ; 91(19): 190403, 2003 Nov 07.
Article in English | MEDLINE | ID: mdl-14611572

ABSTRACT

An improved test of time dilation in special relativity has been performed using laser spectroscopy on fast ions at the heavy-ion storage-ring TSR in Heidelberg. The Doppler-shifted frequencies of a two-level transition in 7Li+ ions at v=0.064c have been measured in the forward and backward direction to an accuracy of Deltanu/nu=1 x 10(-9) using collinear saturation spectroscopy. The result confirms the relativistic Doppler formula and sets a new limit of 2.2 x 10(-7) for deviations from the time dilation factor gamma(SR)=(1-v2/c2)(-1/2).

SELECTION OF CITATIONS
SEARCH DETAIL
...