Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Clin Neurol Neurosurg ; 244: 108412, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38986364

ABSTRACT

BACKGROUND: Catheter shaping is vital in cerebral aneurysm coil embolization; however, understanding three-dimensional (3D) vascular structures on two-dimensional screens is challenging. Although 3D-printed vascular models are helpful, they demand time, effort, and sterility. This study explores whether mixed-reality (MR) devices displaying 3D computer graphics (3D-CG) can address these issues. METHODS: This study focused on magnetic resonance imaging (MRI) of seven cases of cerebral aneurysms. Head-mounted display (HMD) and spatial reality display (SRD) MR devices were used, and applications for 3D-CG display at a 1:1 scale and a 3D-CG control panel were developed. Catheters shaped using a 3D printer, HMD, and SRD were inserted into hollow models to assess their accessibility and positioning. RESULTS: The concordance rate of the 3D printer and HMD groups in terms of accessibility to the aneurysm was 71.4 %, while that of the 3D printer and SRD group was 85.7 %, and that of the HMD and SRD group was 85.7 %. The concordance rates of positioning in the 3D printer and HMD groups, 3D printer and SRD groups, and HMD and SRD groups were 85.7 %, 85.7 %, and 100 %, respectively. CONCLUSIONS: MR devices facilitate catheter shaping in cerebral aneurysm coil embolization and offer a time-efficient, precise, and sterile alternative to traditional 3D printing methods.


Subject(s)
Catheters , Embolization, Therapeutic , Intracranial Aneurysm , Printing, Three-Dimensional , Humans , Intracranial Aneurysm/therapy , Intracranial Aneurysm/diagnostic imaging , Embolization, Therapeutic/methods , Embolization, Therapeutic/instrumentation , Male , Female , Middle Aged , Aged , Magnetic Resonance Imaging , Adult
2.
In Vivo ; 38(2): 944-948, 2024.
Article in English | MEDLINE | ID: mdl-38418122

ABSTRACT

BACKGROUND/AIM: Transient pain enhancement or flare pain, is observed following the administration of immune checkpoint inhibitors (ICIs). However, the detailed mechanism of this phenomenon remains unclear. In this report, we present our experience of documenting the course of flare pain following ICI administration in six cases. PATIENTS AND METHODS: Six patients with advanced solid tumors received ICI monotherapy between July 2017 and November 2019. Their pain increased within hours of ICI administration despite being stable before ICI administration. We evaluated the changes in the numerical rating scale (NRS) score over 72 h after ICI administration. RESULTS: Four non-small cell lung cancer patients, one gastric cancer patient, and one renal cell cancer patient were included. Four patients experienced an increase in NRS, as evidenced by scores on two or more scales compared to the day before administration, whereas two patients showed an increase only on one scale. The NRS score decreased to almost the same level as that on the day before administration. Flare pain is observed in the same area as the primary site. Most of the pain was alleviated without the need for rescue analgesics, although one patient experienced a 4-point increase in the NRS scale. CONCLUSION: Flare pain may occur following ICI administration. Healthcare providers should be aware of these events and provide patients with suitable information and coping techniques.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Kidney Neoplasms , Lung Neoplasms , Humans , Immune Checkpoint Inhibitors/adverse effects , Carcinoma, Non-Small-Cell Lung/drug therapy , Lung Neoplasms/drug therapy , Pain/chemically induced , Pain/diagnosis , Pain/drug therapy , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL