Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Biosens Bioelectron ; 262: 116546, 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-38968774

ABSTRACT

Electronic communication in natural systems makes use, inter alia, of molecular transmission, where electron transfer occurs within networks of redox reactions, which play a vital role in many physiological systems. In view of the limited understanding of redox signaling, we developed an approach and an electrochemical-optical lab-on-a-chip to observe cellular responses in localized redox environments. The developed fluidic micro-system uses electrogenetic bacteria in which a cellular response is activated to electrically and chemically induced stimulations. Specifically, controlled environments for the cells are created by using microelectrodes to generate spatiotemporal redox gradients. The in-situ cellular responses at both single-cell and population levels are monitored by optical microscopy. The elicited electrogenetic fluorescence intensities after 210 min in response to electrochemical and chemical activation were 1.3 × 108±0.30 × 108 arbitrary units (A.U.) and 1.2 × 108±0.30 × 108 A.U. per cell population, respectively, and 1.05 ± 0.01 A.U. and 1.05 ± 0.01 A.U. per-cell, respectively. We demonstrated that redox molecules' mass transfer between the electrode and cells - and not the applied electrical field - activated the electrogenetic cells. Specifically, we found an oriented amplified electrogenetic response on the charged electrodes' downstream side, which was determined by the location of the stimulating electrodes and the flow profile. We then focused on the cellular responses and observed distinct subpopulations that were attributed to electrochemical rather than chemical stimulation, with the distance between the cells and the stimulating electrode being the main determinant. These observations provide a comprehensive understanding of the mechanisms by which diffusible redox mediators serve as electron shuttles, imposing context and activating electrogenetic responses.


Subject(s)
Biosensing Techniques , Oxidation-Reduction , Biosensing Techniques/methods , Single-Cell Analysis/methods , Lab-On-A-Chip Devices , Microelectrodes , Electrochemical Techniques/methods , Equipment Design , Electron Transport
2.
Mol Ther Nucleic Acids ; 33: 713-732, 2023 Sep 12.
Article in English | MEDLINE | ID: mdl-37662967

ABSTRACT

Mitochondrial anti-viral signaling protein (MAVS) plays an important role in host defense against viral infection via coordinating the activation of NF-κB and interferon regulatory factors. The mitochondrial-bound form of MAVS is essential for its anti-viral innate immunity. Recently, tumor cells were proposed to mimic a viral infection by activating RNA-sensing pattern recognition receptors. Here, we demonstrate that MAVS is overexpressed in a panel of viral non-infected cancer cell lines and patient-derived tumors, including lung, liver, bladder, and cervical cancers, and we studied its role in cancer. Silencing MAVS expression reduced cell proliferation and the expression and nuclear translocation of proteins associated with transcriptional regulation, inflammation, and immunity. MAVS depletion reduced expression of the inflammasome components and inhibited its activation/assembly. Moreover, MAVS directly interacts with the mitochondrial protein VDAC1, decreasing its conductance, and we identified the VDAC1 binding site in MAVS. Our findings suggest that MAVS depletion, by reducing cancer cell proliferation and inflammation, represents a new target for cancer therapy.

3.
Talanta ; 181: 57-64, 2018 May 01.
Article in English | MEDLINE | ID: mdl-29426541

ABSTRACT

In vivo monitoring of the neurotransmitter dopamine can potentially improve the diagnosis of neurological disorders and elucidate their underlying biochemical mechanisms. While electrochemical sensors can detect unlabeled dopamine molecules, their sensing performance is dramatically reduced by electrochemical currents generated by other, interfering molecules (e.g., uric acid) in the biological environment. To overcome this caveat, the surface of the sensor is often modified with electrocatalytic materials, which are encapsulated inside a polymeric film; however, the effect of the encapsulating film on the sensing performance of the electrode has not been systematically studied. This study characterizes the effect of loading carbon nanotubes (CNTs) onto a chitosan film on the electrochemical sensing performance of dopamine in the presence of uric acid. Higher CNT loading increases the diffusion and electron transfer rate coefficients of the sensor and, in the presence of uric acid, provides better sensitivity (3.00µALµmol-1 for 1.75% CNT loading, vs 0.01µALµmol-1 for 1% loading) but a poorer limit-of-detection (2.00µmolL-1vs 1.00, respectively), as reported here for the first time. These findings can help optimize the sensitivity and the limit-of-detection of electrochemical sensors in complex biofluids to enable an in vivo monitoring of dopamine and other redox-active molecules.


Subject(s)
Biosensing Techniques/methods , Chitosan/chemistry , Dopamine/analysis , Electrochemical Techniques/methods , Nanotubes, Carbon/chemistry , Dopamine/cerebrospinal fluid , Electrochemical Techniques/instrumentation , Electrodes , Humans , Membranes, Artificial , Microscopy, Atomic Force , Microscopy, Electron, Scanning , Nanotubes, Carbon/ultrastructure , Reproducibility of Results
4.
Oncotarget ; 8(62): 105492-105509, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-29285267

ABSTRACT

Adenocarcinoma (AC) and squamous cell carcinoma (SCC), sub-types of non-small cell lung cancer (NSCLC), both present unique features at the genome, epigenome, transcriptome and proteome levels, as well as shared clinical and histopathological characteristics, but differ in terms of treatment. To ensure proper treatment, one must be able to distinguish between these sub-types. Here, we identify novel biomarker proteins in NSCLC, allowing for distinguishing between the AC and SCC sub-types. Proteomics analysis distinguished between healthy and tumor tissues, with the expression level of 1,494 proteins being altered, 378 of which showed a ≥|100|-fold change. Enrichment of proteins related to protein synthesis and degradation, and of proteins associated with mitochondria, metabolism, and apoptosis, was found. Network analysis defined groups of proteins, such as those associated with cell metabolic processes or with fatty acid/lipid metabolism and transport. Several biomarkers that enable for distinguishing between AC and SCC were identified here for the first time, and together with previous reports confirmed here, led us to propose a list of proteins differentially expressed in SCC and AC. Some of these biomarkers are clear signatures for AC or SCC and four of them are secreted proteins. The presence of the mitochondrial protein SMAC/Diablo in the nucleus was found to be a signature for SCC. Precise diagnosis of AC and SCC is essential for selecting appropriate treatment and thus, increasing patient life expectancy. Finally, the search for drugs that target some of these biomarkers may lead to new treatments for lung cancer.

SELECTION OF CITATIONS
SEARCH DETAIL