Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
Biomater Transl ; 5(2): 157-174, 2024.
Article in English | MEDLINE | ID: mdl-39351163

ABSTRACT

Peripheral nerve injury poses a great threat to neurosurgery and limits the regenerative potential of sacral nerves in the neurogenic bladder. It remains unknown whether electrical stimulation can facilitate sacral nerve regeneration in addition to modulate bladder function. The objective of this study was to utilise electrical stimulation in sacra nerve crush injury with newly constructed electroconductive scaffold and explore the role of macrophages in electrical stimulation with crushed nerves. As a result, we generated a polypyrrole-coated polycaprolactone/silk fibroin scaffold through which we applied electrical stimulation. The electrical stimulation boosted nerve regeneration and polarised the macrophages towards the M2 phenotype. An in vitro test using bone marrow derived macrophages revealed that the pro-regenerative polarisation of M2 were significantly enhanced by electrical stimulation. Bioinformatics analysis showed that the expression of signal transducer and activator of transcriptions (STATs) was differentially regulated in a way that promoted M2-related genes expression. Our work indicated the feasibility of electricals stimulation used for sacral nerve regeneration and provided a firm demonstration of a pivotal role which macrophages played in electrical stimulation.

2.
J Xray Sci Technol ; 2024 Sep 18.
Article in English | MEDLINE | ID: mdl-39302409

ABSTRACT

BACKGROUND: Dynamic cerebral perfusion CT (DCPCT) can provide valuable insight into cerebral hemodynamics by visualizing changes in blood within the brain. However, the associated high radiation dose of the standard DCPCT scanning protocol has been a great concern for the patient and radiation physics. Minimizing the x-ray exposure to patients has been a major effort in the DCPCT examination. A simple and cost-effective approach to achieve low-dose DCPCT imaging is to lower the x-ray tube current in data acquisition. However, the image quality of low-dose DCPCT will be degraded because of the excessive quantum noise. OBJECTIVE: To obtain high-quality DCPCT images, we present a statistical iterative reconstruction (SIR) algorithm based on penalized weighted least squares (PWLS) using adaptive prior image constrained total generalized variation (APICTGV) regularization (PWLS-APICTGV). METHODS: APICTGV regularization uses the precontrast scanned high-quality CT image as an adaptive structural prior for low-dose PWLS reconstruction. Thus, the image quality of low-dose DCPCT is improved while essential features of targe image are well preserved. An alternating optimization algorithm is developed to solve the cost function of the PWLS-APICTGV reconstruction. RESULTS: PWLS-APICTGV algorithm was evaluated using a digital brain perfusion phantom and patient data. Compared to other competing algorithms, the PWLS-APICTGV algorithm shows better noise reduction and structural details preservation. Furthermore, the PWLS-APICTGV algorithm can generate more accurate cerebral blood flow (CBF) map than that of other reconstruction methods. CONCLUSIONS: PWLS-APICTGV algorithm can significantly suppress noise while preserving the important features of the reconstructed DCPCT image, thus achieving a great improvement in low-dose DCPCT imaging.

3.
Biosens Bioelectron ; 263: 116578, 2024 Nov 01.
Article in English | MEDLINE | ID: mdl-39038398

ABSTRACT

Peripheral nerve injury (PNI) poses a significant public health issue, often leading to muscle atrophy and persistent neuropathic pain, which can drastically impact the quality of life for patients. Electrical stimulation represents an effective and non-pharmacological treatment to promote nerve regeneration. Yet, the postoperative application of electrical stimulation remains a challenge. Here, we propose a fully biodegradable, self-powered nerve guidance conduit (NGC) based on dissolvable zinc-molybdenum batteries. The conduit can offer topographic guidance for nerve regeneration and deliver sustained electrical cues between both ends of a transected nerve stump, extending beyond the surgical window. Schwann cell proliferation and adenosine triphosphate (ATP) production are enhanced by the introduction of the zinc-molybdenum batteries. In rodent models with 10-mm sciatic nerve damage, the device effectively enhances nerve regeneration and motor function recovery. This study offers innovative strategies for creating biodegradable and electroactive devices that hold important promise to optimize therapeutic outcomes for nerve regeneration.


Subject(s)
Nerve Regeneration , Peripheral Nerve Injuries , Sciatic Nerve , Zinc , Animals , Peripheral Nerve Injuries/therapy , Zinc/chemistry , Sciatic Nerve/physiology , Sciatic Nerve/injuries , Rats , Electric Power Supplies , Molybdenum/chemistry , Schwann Cells , Rats, Sprague-Dawley , Humans , Guided Tissue Regeneration/instrumentation , Guided Tissue Regeneration/methods , Biosensing Techniques , Absorbable Implants
4.
Phys Med Biol ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38588674

ABSTRACT

The x-ray radiation dose in computed tomography (CT) examination has been a major concern for patients. Lowing the tube current and exposure time in data acquisition is a straightforward and cost-effective strategy to reduce the x-ray radiation dose. However, this will inevitably increase the noise fluctuations in measured projection data, and the corresponding CT image quality will be severely degraded if noise suppression is not performed during image reconstruction. To reconstruct high-quality low-dose CT image, we present a spatial-radon domain total generalized variation (SRDTGV) regularization for statistical iterative reconstruction (SIR) based on penalized weighted least-squares (PWLS) principle, which is called PWLS-SRDTGV for simplicity. The presented PWLS-SRDTGV model can simultaneously reconstruct high-quality CT image in space domain and its corresponding projection in radon domain. An efficient split Bregman algorithm was applied to minimize the cost function of the proposed reconstruction model. Qualitative and quantitative studies were performed to evaluate the effectiveness of the PWLS-SRDTGV image reconstruction algorithm using a digital 3D XCAT phantom and an anthropomorphic torso phantom. The experimental results demonstrate that PWLS-SRDTGV algorithm achieves notable gains in noise reduction, streak artifact suppression, and edge preservation compared with competing reconstruction approaches.

5.
Adv Healthc Mater ; 13(3): e2302128, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37922434

ABSTRACT

Peripheral nerve injuries (PNI) can lead to mitochondrial dysfunction and energy depletion within the affected microenvironment. The objective is to investigate the potential of transplanting mitochondria to reshape the neural regeneration microenvironment. High-purity functional mitochondria with an intact structure are extracted from human umbilical cord-derived mesenchymal stem cells (hUCMSCs) using the Dounce homogenization combined with ultracentrifugation. Results show that when hUCMSC-derived mitochondria (hUCMSC-Mitos) are cocultured with Schwann cells (SCs), they promote the proliferation, migration, and respiratory capacity of SCs. Acellular nerve allografts (ANAs) have shown promise in nerve regeneration, however, their therapeutic effect is not satisfactory enough. The incorporation of hUCMSC-Mitos within ANAs has the potential to remodel the regenerative microenvironment. This approach demonstrates satisfactory outcomes in terms of tissue regeneration and functional recovery. Particularly, the use of metabolomics and bioenergetic profiling is used for the first time to analyze the energy metabolism microenvironment after PNI. This remodeling occurs through the enhancement of the tricarboxylic acid cycle and the regulation of associated metabolites, resulting in increased energy synthesis. Overall, the hUCMSC-Mito-loaded ANAs exhibit high functionality to promote nerve regeneration, providing a novel regenerative strategy based on improving energy metabolism for neural repair.


Subject(s)
Mesenchymal Stem Cells , Nerve Tissue , Peripheral Nerve Injuries , Humans , Sciatic Nerve , Schwann Cells , Peripheral Nerve Injuries/therapy , Extracellular Matrix , Nerve Regeneration/physiology
6.
Chempluschem ; 84(4): 382-386, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31939221

ABSTRACT

Developing highly efficient and stable noble-metal-free catalysts toward catalytic hydrolysis of ammonia borane (AB) for hydrogen storage is highly desirable, but still remains challenging. We report a simple and in situ co-reduction approach to synthesize bimetallic NiCoP nanoparticles (NPs) supported on reduced graphene oxide (rGO). Thanks to the strong electronic interaction between Ni, Co, and P, the as-synthesized Co89.8 Ni10.2 P11.7 /rGO catalyst exhibits superior catalytic performance towards hydrolysis of AB, with the turnover frequency value (TOF) of 18.6 min-1 , which is about 2.5 times higher than that of NiCo/rGO.

7.
Curr Genomics ; 8(6): 370-8, 2007 Sep.
Article in English | MEDLINE | ID: mdl-19412437

ABSTRACT

Nucleotide insertions and deletions (indels) are responsible for gaps in the sequence alignments. Indel is one of the major sources of evolutionary change at the molecular level. We have examined the patterns of insertions and deletions in the 19 mammalian genomes, and found that deletion events are more common than insertions in the mammalian genomes. Both the number of insertions and deletions decrease rapidly when the gap length increases and single nucleotide indel is the most frequent in all indel events. The frequencies of both insertions and deletions can be described well by power law.

SELECTION OF CITATIONS
SEARCH DETAIL