Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
3.
Transl Androl Urol ; 12(5): 898-917, 2023 May 31.
Article in English | MEDLINE | ID: mdl-37305622

ABSTRACT

Background and Objective: The artificial urinary sphincter (AUS) remains the gold standard for treatment of stress urinary incontinence (SUI). However, highly complex patients such as those with bulbar urethral compromise, bladder pathology, and lower urinary complications pose a particular challenge for the surgeon. In this article, we will address critical risk factors and synthesize existent data across relevant disease states to support surgeons in successful management of SUI in high-risk patients. Methods: A comprehensive review of current literature was performed utilizing the search term "artificial urinary sphincter" in conjunction with any of the following additional terms: "radiation", "urethral stricture", "posterior urethral stenosis", "vesicourethral anastomotic stenosis", "bladder neck contracture", "pelvic fracture urethral injury", "penile revascularization", "inflatable penile prosthesis", and "erosion". Guidance is provided based upon expert opinion where existing literature was sparse or nonexistent. Key Content and Findings: Several known patient risk factors are associated with AUS failure and can ultimately lead to device explantation. Each risk factor requires careful consideration and investigation, or intervention as appropriate, prior to device placement. Optimization of urethral health, confirmation of anatomic and functional stability of the lower urinary tract, and thorough patient counseling are a necessity for these high-risk patients. Several surgical strategies to decrease device complications can be considered: optimization of testosterone, avoidance of 3.5 cm AUS cuff, transcorporal AUS cuff placement, relocation of AUS cuff site, use of lower pressure-regulating balloon, penile revascularization, and intermittent nocturnal deactivation. Conclusions: A number of patient risk factors are associated with AUS failure and can ultimately lead to device explantation. We present an algorithm for management of high-risk patients. Optimization of urethral health, confirmation of anatomic and functional stability of the lower urinary tract, and thorough patient counseling are a necessity for these high-risk patients.

4.
Urology ; 152: 35-41, 2021 06.
Article in English | MEDLINE | ID: mdl-33647306

ABSTRACT

OBJECTIVES: To describe outcomes of reservoir placement, exchange, and extraction from the lateral retroperitoneum (LR) in complex patients with a three-piece inflatable penile prosthesis (IPP). METHODS: A retrospective chart review was performed on all patients that underwent placement of an IPP from 2009 to 2019. Patients with placement of the reservoir in the LR were identified. Intraoperative complications during reservoir placement, exchange, or removal, reservoir-related outcomes, and secondary device-related outcomes were collated and compared to patients who underwent traditional Space of Retzius reservoir placement. RESULTS: A total of 587 men underwent primary IPP placement with 321 patients undergoing reservoir placement in the SOR and 266 in the LR. No significant differences were found in intra-operative reservoir-related outcomes (P=.272) between the 2 groups during placement, replacement, or extraction. Bowel injury occurred in 1 patient in the LR group during placement. No significant differences were found in postoperative reservoir complications (P= .534). Both groups each had one instance of patient reported bulge and pain at reservoir site (P= .6777). Two (0.6%) patients in the SOR group and 3 (1.1%) patients in the LR group had a reservoir failure or leak. There was a trend towards a lower rate of device infections in the LR group (1.9%) compared to the SOR group (4.7%) (P= .063). There were no significant differences in overall device mechanical failure rates between both groups (P= .919). CONCLUSIONS: Reservoir placement in the LR is safe in patients with complex pelvic anatomy with equivalent device durability and no difference in surgical outcomes compared to standard retropubic reservoir placement.


Subject(s)
Erectile Dysfunction/surgery , Penile Implantation/methods , Penile Prosthesis , Aged , Humans , Male , Middle Aged , Prosthesis Design , Retroperitoneal Space , Retrospective Studies , Treatment Outcome
5.
PLoS One ; 6(1): e16317, 2011 Jan 21.
Article in English | MEDLINE | ID: mdl-21283700

ABSTRACT

An ancestral polymorphic allele of the human autophagy-related gene IRGM1 is associated with altered gene expression and a genetic risk for Crohn's Disease (CD). We used the single nucleotide polymorphism rs10065172C/T as a marker of this polymorphic allele and genotyped 370 African American and 177 Caucasian tuberculosis (TB) cases and 180 African American and 110 Caucasian controls. Among African Americans, the TB cases were more likely to carry the CD-related T allele of rs10065172 (odds ratio of 1.54; 95% confidence interval, 1.17-2.02; P<0.01) compared to controls. Our finding suggests that this CD-related IRGM1 polymorphic allele is also associated with human susceptibility to TB disease among African Americans.


Subject(s)
Black or African American/genetics , GTP-Binding Proteins/genetics , Genetic Predisposition to Disease/ethnology , Polymorphism, Single Nucleotide , Tuberculosis/ethnology , Tuberculosis/genetics , Alleles , Crohn Disease/genetics , GTP-Binding Proteins/physiology , Genetic Markers , Genetic Predisposition to Disease/genetics , Humans , White People/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...