Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 503
Filter
1.
Circulation ; 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39101203

ABSTRACT

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year (P<0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4-8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital (P=0.0005), 30-day (P=0.004), and 1-year mortality rates (P=0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.

2.
J Am Coll Cardiol ; 84(9): 848-861, 2024 Aug 27.
Article in English | MEDLINE | ID: mdl-39168571

ABSTRACT

Transcatheter aortic valve (TAV) thrombosis may manifest as subclinical leaflet thrombosis (SLT) and clinical valve thrombosis. SLT is relatively common (10%-20%) after transcatheter aortic valve replacement, but clinical implications are uncertain. Clinical valve thrombosis is rare (1.2%) and associated with bioprosthetic valve failure, neurologic or thromboembolic events, heart failure, and death. Treatment for TAV thrombosis has been understudied. In principle, anticoagulation may prevent TAV thrombosis. Non-vitamin K oral anticoagulants, as compared to antiplatelet therapy, are associated with reduced incidence of SLT, although at the cost of higher bleeding and all-cause mortality risk. We present an overview of existing literature for management of TAV thrombosis and propose a rational treatment algorithm. Vitamin K antagonists or non-vitamin K oral anticoagulants are the cornerstone of antithrombotic treatment. In therapy-resistant or clinically unstable patients, ultraslow, low-dose infusion of thrombolytics seems effective and safe and may be preferred over redo-transcatheter aortic valve replacement or explant surgery.


Subject(s)
Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Thrombosis/prevention & control , Thrombosis/etiology , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Fibrinolytic Agents/therapeutic use , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects
3.
JACC Cardiovasc Interv ; 17(16): 1936-1945, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39197992

ABSTRACT

BACKGROUND: Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited. OBJECTIVES: This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned. METHODS: The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs ≥55 mm). RESULTS: The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to ≤2+ and ≤1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices ≥55 mm) with well-sustained results at 1-month follow-up (TR ≤2+ in 95.0% and ≤1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size. CONCLUSIONS: Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies.


Subject(s)
Cardiac Catheterization , Compassionate Use Trials , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Registries , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Female , Male , Retrospective Studies , Aged , Treatment Outcome , Time Factors , Aged, 80 and over , Tricuspid Valve/surgery , Tricuspid Valve/physiopathology , Tricuspid Valve/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/mortality , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Risk Factors , Hospital Mortality , Postoperative Complications/etiology , Jugular Veins
4.
JACC Cardiovasc Interv ; 17(16): 1916-1931, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39197990

ABSTRACT

BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Hospital Mortality , Prosthesis Design , Recovery of Function , Registries , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Treatment Outcome , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Aged , United States/epidemiology , Risk Factors , Time Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Risk Assessment , Prevalence , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Retrospective Studies , Centers for Medicare and Medicaid Services, U.S. , Hemodynamics
5.
Radiology ; 312(2): e240229, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39136569

ABSTRACT

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (r = 0.92; P < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; P = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm3 [95% LoA: -0.27 cm3, 0.19 cm3] and 0.02 cm3 [95% LoA: -0.14 cm3, 0.19 cm3], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almeida in this issue.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Computed Tomography Angiography , Fibrosis , Humans , Male , Prospective Studies , Female , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Middle Aged , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/surgery , Calcinosis/diagnostic imaging , Calcinosis/pathology , Fibrosis/diagnostic imaging , Computed Tomography Angiography/methods , Aged
7.
JACC Cardiovasc Interv ; 17(13): 1559-1573, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986655

ABSTRACT

BACKGROUND: The impact of intraprocedural results following transcatheter edge-to-edge repair (TEER) in primary mitral regurgitation (MR) is controversial. OBJECTIVES: This study sought to investigate the prognostic impact of intraprocedural residual mitral regurgitation (rMR) and mean mitral valve gradient (MPG) in patients with primary MR undergoing TEER. METHODS: The PRIME-MR (Outcomes of Patients Treated With Mitral Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation) registry included consecutive patients with primary MR undergoing TEER from 2008 to 2022 at 27 international sites. Clinical outcomes were assessed according to intraprocedural rMR and mean MPG. Patients were categorized according to rMR (optimal result: ≤1+, suboptimal result: ≥2+) and MPG (low gradient: ≤5 mm Hg, high gradient: > 5 mm Hg). The prognostic impact of rMR and MPG was evaluated in a Cox regression analysis. The primary endpoint was 2-year all-cause mortality or heart failure hospitalization. RESULTS: Intraprocedural rMR and mean MPG were available in 1,509 patients (median age = 82 years [Q1-Q3: 76.0-86.0 years], 55.1% male). Kaplan-Meier analysis according to rMR severity showed significant differences for the primary endpoint between rMR ≤1+ (29.1%), 2+ (41.7%), and ≥3+ (58.0%; P < 0.001), whereas there was no difference between patients with a low (32.4%) and high gradient (42.1%; P = 0.12). An optimal result/low gradient was achieved in most patients (n = 1,039). The worst outcomes were observed in patients with a suboptimal result/high gradient. After adjustment, rMR ≥2+ was independently linked to the primary endpoint (HR: 1.87; 95% CI: 1.32-2.65; P < 0.001), whereas MPG >5 mm Hg was not (HR: 0.78; 95% CI: 0.47-1.31; P = 0.35). CONCLUSIONS: Intraprocedural rMR but not MPG independently predicted clinical outcomes following TEER for primary MR. When performing TEER in primary MR, optimal MR reduction seems to outweigh the impact of high transvalvular gradients.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Hemodynamics , Mitral Valve Insufficiency , Mitral Valve , Recovery of Function , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Male , Female , Aged , Treatment Outcome , Mitral Valve/surgery , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Risk Factors , Time Factors , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Heart Failure/physiopathology , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/diagnostic imaging , Heart Failure/etiology , Risk Assessment
8.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38866455

ABSTRACT

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
9.
Am J Cardiol ; 224: 46-54, 2024 08 01.
Article in English | MEDLINE | ID: mdl-38844194

ABSTRACT

Residual significant mitral regurgitation (MR) can increase the risk of adverse events after transcatheter aortic valve replacement (TAVR). The clinical benefits of staged transcatheter edge-to-edge repair (TEER) after TAVR remain underexplored. This study aimed to investigate the clinical outcomes of staged TEER for residual significant MR after TAVR. This observational study included 314 consecutive patients with chronic residual grade 3+ or 4+ MR at the 30-day follow-up after TAVR, with 104 patients (33.1%) treated with staged TEER (TEER group) and 210 (66.9%) with medical therapy alone. The primary composite outcomes were all-cause mortality and heart failure hospitalization at 2 years. Additional analysis, including changes in MR grade and the New York Association functional classification, and subgroup outcome comparisons based on MR etiology were also conducted. In our study, the rate of primary composite outcome was lower in the TEER group than in the medical therapy alone group (33.7% vs 48.1%, p = 0.015). Significant improvement in MR grade and New York Association class was observed in the TEER group after 2 years. The subgroup analysis demonstrated that in patients with degenerative MR, a lower incidence of composite outcome and heart failure hospitalization was observed in the TEER group (hazard ratio 0.35, 95% confidence interval 0.23 to 0.53, p <0.001). In conclusion, staged TEER after TAVR was associated with reduced MR and improved clinical outcomes. The clinical significance of MR after TAVR should be carefully evaluated, and TEER should be considered for patients with significant residual MR, particularly, those with degenerative MR.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Mitral Valve Insufficiency/surgery , Aged, 80 and over , Aortic Valve Stenosis/surgery , Treatment Outcome , Aged , Follow-Up Studies , Postoperative Complications/epidemiology , Retrospective Studies , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Heart Failure , Time Factors
10.
Arch. cardiol. Méx ; 94(2): 219-239, Apr.-Jun. 2024. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1556919

ABSTRACT

resumen está disponible en el texto completo


Abstract This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.

11.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Risk Factors , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Treatment Outcome , Aged, 80 and over , Incidence , Time Factors , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/physiopathology , Europe , Risk Assessment , Prosthesis Design , Odds Ratio , Stroke/etiology , Stroke/diagnosis , Heart Failure/physiopathology , Heart Failure/etiology , Heart Failure/diagnosis , Retrospective Studies
12.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726720

ABSTRACT

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Subject(s)
Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
13.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Male , Aged , Prospective Studies , Aortic Valve Stenosis/surgery , Prosthesis Failure , Prosthesis Design , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Treatment Outcome , Coronary Occlusion/surgery , Postoperative Complications/epidemiology
14.
Eur Heart J Cardiovasc Imaging ; 25(9): 1276-1286, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-38693866

ABSTRACT

AIMS: Evaluation of left and right ventricular (RV) longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and RV longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30 days and 1 year after AVR. METHODS AND RESULTS: Left ventricular (LV) longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER 2A surgical AVR (SAVR) arm (n = 985) and from the PARTNER 2 SAPIEN 3 registry (n = 719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline was associated with increased risk of the composite of death, hospitalization, and stroke at 5 years [adjusted hazard ratios (HRs) for LV LS < 15%: 1.24, 95% confidence interval (CI) 1.05-1.45, P = 0.001; TAPSE < 14 mm: 1.44, 95% CI 1.21-1.73, P < 0.001; RV-PA coupling < 0.55 mm/mmHg: 1.32, 95% CI 1.07-1.63, P = 0.011]. Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5 years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95% CI 1.08-1.68, P = 0.009) but not with TAVR (HR: 1.12, 95% CI 0.88-1.42). Lower RV-PA coupling at 30 days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30 days were associated with inferior clinical outcomes at 5 years. In patients with LVEF < 50%, TAVR was associated with superior 5-year outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Registries , Humans , Male , Female , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Risk Assessment , Systole , Aged, 80 and over , Treatment Outcome , Stroke Volume/physiology , Echocardiography , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology
16.
EuroIntervention ; 20(10): e630-e642, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38776146

ABSTRACT

BACKGROUND: A short dual antiplatelet therapy (DAPT) duration has been proposed for patients at high bleeding risk (HBR) undergoing drug-eluting coronary stent (DES) implantation. Whether this strategy is safe and effective after a non-ST-segment elevation acute coronary syndrome (NSTE-ACS) remains uncertain. AIMS: We aimed to compare the impact of 1-month versus 3-month DAPT on clinical outcomes after DES implantation among HBR patients with or without NSTE-ACS. METHODS: This is a prespecified analysis from the XIENCE Short DAPT programme involving three prospective, international, single-arm studies evaluating the safety and efficacy of 1-month (XIENCE 28 USA and Global) or 3-month (XIENCE 90) DAPT among HBR patients after implantation of a cobalt-chromium everolimus-eluting stent. Ischaemic and bleeding outcomes associated with 1- versus 3-month DAPT were assessed according to clinical presentation using propensity score stratification. RESULTS: Of 3,364 HBR patients (1,392 on 1-month DAPT and 1,972 on 3-month DAPT), 1,164 (34.6%) underwent DES implantation for NSTE-ACS. At 12 months, the risk of the primary endpoint of death or myocardial infarction was similar between 1- and 3-month DAPT in patients with (hazard ratio [HR] 1.09, 95% confidence interval [CI]: 0.71-1.65) and without NSTE-ACS (HR 0.88, 95% CI: 0.63-1.23; p-interaction=0.34). The key secondary endpoint of Bleeding Academic Research Consortium (BARC) Type 2-5 bleeding was consistently reduced in both NSTE-ACS (HR 0.57, 95% CI: 0.37-0.88) and stable patients (HR 0.84, 95% CI: 0.61-1.15; p-interaction=0.15) with 1-month DAPT. CONCLUSIONS: Among HBR patients undergoing implantation of an everolimus-eluting stent, 1-month, compared to 3-month DAPT, was associated with similar ischaemic risk and reduced bleeding at 1 year, irrespective of clinical presentation.


Subject(s)
Acute Coronary Syndrome , Drug-Eluting Stents , Dual Anti-Platelet Therapy , Hemorrhage , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/instrumentation , Acute Coronary Syndrome/therapy , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Male , Middle Aged , Aged , Female , Hemorrhage/chemically induced , Treatment Outcome , Dual Anti-Platelet Therapy/methods , Prospective Studies , Time Factors , Risk Factors , Non-ST Elevated Myocardial Infarction/therapy , Non-ST Elevated Myocardial Infarction/mortality
17.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599690

ABSTRACT

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
18.
Front Cardiovasc Med ; 11: 1374078, 2024.
Article in English | MEDLINE | ID: mdl-38566964

ABSTRACT

Introduction: Paravalvular leak (PVL) is a severe complication of transcatheter aortic valve replacement (TAVR) that can lead to poor outcomes. TAVR-in-TAVR is a promising treatment for PVL; however, reports on its safety or efficacy are limited. In this study, we aimed to investigate the clinical outcomes of TAVR-in-TAVR using balloon-expandable prostheses for PVLs after TAVR. Methods: We retrospectively analyzed data from patients who underwent TAVR-in-TAVR using balloon-expandable Sapien prostheses for PVL after an initial TAVR at our institution. The procedural success, in-hospital complications, all-cause mortality, and echocardiographic data for up to 2 years post-surgery were evaluated. Results: In total, 31 patients with a mean age of 81.1 ± 7.9 years and mean Society of Thoracic Surgeons score of 8.8 ± 5.4% were identified. The procedural success rate of TAVR-in-TAVR was 96.8% (30/31). No in-hospital deaths, cardiac tamponade, or conversion to sternotomy occurred. Re-intervention was performed in only one patient (3.2%) during hospitalization. The all-cause mortality rates at 30 days and 2 years were 0% and 16.1%, respectively. A significant reduction in the PVL rate was observed at 30 days compared with that at baseline (p < 0.01). Discussion: Our findings suggest that TAVR-in-TAVR using balloon-expandable prostheses is safe and effective for PVL after TAVR with low complication rates and acceptable long-term outcomes. Further studies with larger sample sizes are needed to confirm our findings.

19.
Eur Heart J Cardiovasc Imaging ; 25(8): 1164-1176, 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-38531070

ABSTRACT

AIMS: Left ventricular global longitudinal strain (LVGLS) is a known outcome predictor in transcatheter edge-to-edge repair (TEER) for functional mitral regurgitation (MR). We aimed to assess its prognostic yield in the setting of TEER for chronic primary MR. METHODS AND RESULTS: We conducted a single-centre, retrospective analysis of 323 consecutive patients undergoing isolated, first-time procedures. Stratified by baseline LVGLS quartiles (≤-19%, -18.9% to -16%, -15.9% to -12%, >-12%), the cohort was evaluated for the primary composite outcome of all-cause mortality or heart failure hospitalizations, as well as secondary endpoints consisting of mitral reinterventions and the persistence of significant residual MR and/or functional disability-all along the first year after intervention. Subjects with worse (i.e. less negative) LVGLS exhibited higher comorbidity, more advanced HF, and elevated procedural risk. Post-TEER, those belonging to the worst LVGLS quartile group sustained increased mortality (16.9% vs. 6.3%, Log-Rank P = 0.005, HR 1.75, 95% CI 1.08-4.74, P = 0.041) and, when affected by LV dysfunction/dilatation, more primary outcome events (21.1% vs. 11.5%, Log-Rank P = 0.037, HR 1.68, 95% CI 1.02-5.46, P = 0.047). No association was demonstrated between baseline LVGLS and other endpoints. Upon exploratory analysis, 1-month post-procedural LVGLS directly correlated with and was worse than its baseline counterpart by 1.6%, and a more impaired 1-month value-but not the presence/extent of deterioration-conferred heightened risk for the primary outcome. CONCLUSION: TEER for chronic primary MR is feasible, safe, and efficacious irrespective of baseline LVGLS. Yet, worse baseline LVGLS forecasts a less favourable post-procedural course, presumably reflecting a higher-risk patient profile.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Retrospective Studies , Aged , Prognosis , Cardiac Catheterization/methods , Chronic Disease , Cohort Studies , Treatment Outcome , Risk Assessment , Middle Aged , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology , Aged, 80 and over , Echocardiography , Heart Valve Prosthesis Implantation/methods , Severity of Illness Index , Global Longitudinal Strain
20.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38456883

ABSTRACT

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Hemodynamics , Postoperative Complications/etiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
SELECTION OF CITATIONS
SEARCH DETAIL