Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Neuroeng Rehabil ; 19(1): 131, 2022 12 01.
Article in English | MEDLINE | ID: mdl-36457037

ABSTRACT

BACKGROUND: Exosuits have been shown to reduce metabolic cost of walking and to increase gait performance when used in clinical environment. Currently, these devices are transitioning to private use to facilitate independent training at home and in the community. However, their acceptance in unsupervised settings remains unclear. Therefore, the aim of this study was to investigate end-user perspectives and the adoption of an exosuit in domestic and community settings. METHODS: We conducted a mixed-method study to investigate the usability and user experience of an exosuit, the Myosuit. We leveraged on a cohort of seven expert users, who had the device available at home for at least 28 days. Each participant completed two standardized questionnaires (SUS and QUEST) and one personalized, custom questionnaire. Furthermore, a semi-structured interview with each participant was recorded, verbatim transcribed and analyzed using descriptive thematic analysis. Data collected from device sensors quantified the frequency of use. RESULTS: A mean SUS score of 75.4 out of 100 was reported. Five participants scored above the threshold for above-average usability. Participants also expressed high satisfaction with most of the technical features in the QUEST with an average score of 4.1 (3.86-4.71) out of 5. Participants used the Myosuit mainly for walking outside and exercising at home. However, the frequency of use did not meet the recommendations for physical activity established by the World Health Organization. Five participants used the Myosuit approximately once per week. The two other participants integrated the device in their daily life and used the Myosuit to a greater extent (approx. five times per week). Major factors that prevented an extensive use of the technology were: (i) difficulties in donning that led to (ii) lack of independence and (iii) lack of motivation in exercising. CONCLUSIONS: Although usable for various activities and well perceived, the adoption of the exosuit in domestic and community settings is yet limited. Use outside the clinic poses further challenges that should be considered when developing new wearable robots. Primarily, design should meet the users' claim for independence and increased adjustability of the device.


Subject(s)
Exercise , Walking , Humans , Gait , Motivation , Technology
2.
Front Neurorobot ; 16: 815693, 2022.
Article in English | MEDLINE | ID: mdl-35264940

ABSTRACT

Wearable robotic upper limb orthoses (ULO) are promising tools to assist or enhance the upper-limb function of their users. While the functionality of these devices has continuously increased, the robust and reliable detection of the user's intention to control the available degrees of freedom remains a major challenge and a barrier for acceptance. As the information interface between device and user, the intention detection strategy (IDS) has a crucial impact on the usability of the overall device. Yet, this aspect and the impact it has on the device usability is only rarely evaluated with respect to the context of use of ULO. A scoping literature review was conducted to identify non-invasive IDS applied to ULO that have been evaluated with human participants, with a specific focus on evaluation methods and findings related to functionality and usability and their appropriateness for specific contexts of use in daily life. A total of 93 studies were identified, describing 29 different IDS that are summarized and classified according to a four-level classification scheme. The predominant user input signal associated with the described IDS was electromyography (35.6%), followed by manual triggers such as buttons, touchscreens or joysticks (16.7%), as well as isometric force generated by residual movement in upper-limb segments (15.1%). We identify and discuss the strengths and weaknesses of IDS with respect to specific contexts of use and highlight a trade-off between performance and complexity in selecting an optimal IDS. Investigating evaluation practices to study the usability of IDS, the included studies revealed that, primarily, objective and quantitative usability attributes related to effectiveness or efficiency were assessed. Further, it underlined the lack of a systematic way to determine whether the usability of an IDS is sufficiently high to be appropriate for use in daily life applications. This work highlights the importance of a user- and application-specific selection and evaluation of non-invasive IDS for ULO. For technology developers in the field, it further provides recommendations on the selection process of IDS as well as to the design of corresponding evaluation protocols.

3.
J Neuroeng Rehabil ; 18(1): 170, 2021 12 09.
Article in English | MEDLINE | ID: mdl-34886902

ABSTRACT

BACKGROUND: User-centered design approaches have gained attention over the past decade, aiming to tackle the technology acceptance issues of wearable robotic devices to assist, support or augment human capabilities. While there is a consensus that usability is key to user-centered design, dedicated usability evaluation studies are scarce and clear evaluation guidelines are missing. However, the careful consideration and integration of user needs appears to be essential to successfully develop an effective, efficient, and satisfactory human-robot interaction. It is primarily the responsibility of the developer, to ensure that this users involvement takes place throughout the design process. METHODS: Through an online survey for developers of wearable robotics, we wanted to understand how the design and evaluation in actual daily practice compares to what is reported in literature. With a total of 31 questions, we analyzed the most common wearable robotic device applications and their technology maturity, and how these influence usability evaluation practices. RESULTS: A total of 158 responses from a heterogeneous population were collected and analyzed. The dataset representing contexts of use for augmentation (16.5%), assistance (38.0%), therapy (39.8%), as well as few other specific applications (5.7%), allowed for an insightful analysis of the influence of technology maturity on user involvement and usability evaluation. We identified functionality, ease of use, and performance as the most evaluated usability attributes and could specify which measures are used to assess them. Also, we could underline the frequent use of qualitative measures alongside the expected high prevalence of performance-metrics. In conclusion of the analysis, we derived evaluation recommendations to foster user-centered design and usability evaluation. CONCLUSION: This analysis might serve as state-of-the-art comparison and recommendation for usability studies in wearable robotics. We believe that by motivating for more balanced, comparable and user-oriented evaluation practices, we may support the wearable robotics field in tackling the technology acceptance limitations.


Subject(s)
Robotics , Wearable Electronic Devices , Humans , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL