Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Article in English | MEDLINE | ID: mdl-36173328

ABSTRACT

OBJECTIVES: Aortic root aneurysms often affect younger patients in whom valve-sparing surgery is challenging. Among current techniques, aortic valve-sparing root replacement described by Tirone David has shown encouraging results. The AORTLANTIC registry was instituted for a multicentre long-term evaluation of this procedure. The current initial study evaluates the hospital outcomes of the procedure. METHODS: This is a retrospective study of patients operated between 1 January 2004 and 31 December 2020 in 6 hospitals in western France. All study data were recorded in the national digital database of the French Society of Cardiac Surgery: EPICARD. RESULTS: A total of 524 consecutive patients with a mean age of 53 (15.1) years underwent surgery. 13% (n = 68) of patients presented with acute aortic dissection, 16.5% (n = 86) had associated connective tissue pathology and 7.3% (n = 37) had bicuspid aortic valves. Preoperative aortic regurgitation (AR) ≥2/4 was present in 65.3% (n = 341) of patients. Aortic valvuloplasty was required in 18.6% (n = 95) of patients. At discharge, 92.8% (n = 461) of patients had no or 1/4 AR. The stroke rate was 1.9% (n = 10). Intra-hospital mortality was 1.9% (n = 10). CONCLUSIONS: The AORTLANTIC registry includes 6 centres in western France with >500 patients. Despite numerous complex cases (acute aortic dissections, bicuspid aortic valves, preoperative AR), aortic valve-sparing root replacement has a low intra-hospital mortality. The initial encouraging results of this multicentre study warrant further long-term evaluation by future studies.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Bicuspid Aortic Valve Disease , Blood Vessel Prosthesis Implantation , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Blood Vessel Prosthesis Implantation/methods , Humans , Middle Aged , Registries , Retrospective Studies , Time Factors , Treatment Outcome
2.
Thromb Haemost ; 115(5): 1056-63, 2016 05 02.
Article in English | MEDLINE | ID: mdl-26843425

ABSTRACT

Vitamin K antagonists are currently recommended in patients with 'valvular' atrial fibrillation (AF), e. g. those having mitral stenosis or artificial heart valves. We compared thromboembolic risk in patients with 'non valvular' AF and in those with AF and biological valve replacement (valve bioprosthesis). Among 8962 AF patients seen between 2000 and 2010, a diagnosis of 'non-valvular AF' was found in 8053 (94 %). Among patients with 'valvular' AF, 549 (6 %) had a biological prosthesis. The patients with bioprosthesis were older and had a higher CHA2DS2-VASc score than those with non valvular AF. After a follow-up of 876 ± 1048 days (median 400 days, interquartile range 12-1483), the occurrence of thromboembolic events was similar in AF patients with bioprosthesis compared to those with 'non valvular' AF (hazard ratio [HR] 1.10 95 % confidence interval [CI] 0.83-1.45, p=0.52, adjusted HR 0.93, 95 %CI 0.68-1.25, p=0.61). Factors independently associated with increased risk of stroke/TE events were older age (HR 1.25, 95 %CI 1.16-1.34 per 10-year increase, p< 0.0001) and higher CHA2DS2-VASc score (HR 1.35, 95 %CI 1.24-1.46, p< 0.0001) whilst female gender (HR 0.75, 95 %CI 0.62-0.90, p=0.002), use of vitamin K antagonist (HR 0.83, 95 %CI 0.71-0.98, p=0.03) were independently associated with a lower risk of stroke/TE. Neither the presence of bioprosthesis nor the location of bioprosthesis was independent predictor for TE events. In conclusion, AF patients with bioprosthesis had a non-significantly higher risk of stroke/TE events compared to patients with non-valvular AF. Second, the CHA2DS2-VASc score was independently associated with an increased risk of TE events, and was a valuable determinant of TE risk both in AF patients with non-valvular AF as well as those with bioprosthesis, whether treated or not treated with OAC.


Subject(s)
Anticoagulants/administration & dosage , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Stroke/etiology , Thromboembolism/etiology , Administration, Oral , Aged , Aged, 80 and over , Female , France , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Vitamin K/antagonists & inhibitors
4.
Eur J Cardiothorac Surg ; 49(5): 1462-8, 2016 May.
Article in English | MEDLINE | ID: mdl-26530269

ABSTRACT

OBJECTIVES: Aortic valve replacement (AVR) using a bioprosthesis remains controversial for patients aged 50-65 years. This cohort study reports the very long-term outcomes of AVR using Carpentier-Edwards Perimount pericardial bioprosthesis in this age group. METHODS: From 1984 to 2008, 522 Carpentier-Edwards Perimount pericardial aortic bioprostheses were implanted in 516 patients aged 50-65 years (mean age, 60 ± 4 years; 19% female). Multiple valve replacements were excluded fro m our cohort. Baseline demographic, perioperative and follow-up data were recorded prospectively. Mean follow-up was 9 ± 6 years, for a total of 4428 valve-years. Follow-up was complete for 97% of patients included. RESULTS: Operative mortality rate was 2%. One hundred and forty-six late deaths occurred for a linearized rate of 3%/valve-year. Actuarial survival rates averaged 73 ± 2, 59 ± 3 and 35 ± 5% after 10, 15 and 20 years of follow-up, respectively. Mortality rate associated with reoperation was 2%. Actuarial freedom from reoperation rates due to structural valve deterioration (SVD) at 10, 15 and 20 years was respectively of 91 ± 2, 76 ± 3 and 50 ± 6%. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 30 ± 3%. Expected valve durability was 19 years for this age group. Age was not a significant risk factor for SVD in this middle-aged population. CONCLUSIONS: In patients aged 50-65 years undergoing AVR with the Carpentier-Edwards Perimount bioprosthesis, the expected valve durability was 19 years. Age was not a significant risk factor for SVD within this age group. Patient selection and attention to timing of reintervention may be determinants of long-term outcomes.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Female , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Retrospective Studies
5.
Ann Thorac Surg ; 100(3): 853-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26187006

ABSTRACT

BACKGROUND: Aortic valve replacement using a bioprosthesis remains controversial for patients younger than 60 years because of missing data on long-term outcomes in this age group. METHODS: From 1984 to 2008, 383 Carpentier-Edwards Perimount pericardial aortic bioprostheses were implanted in 373 patients 60 years or younger (mean age, 51.0 ± 9.2 years; 19% female). Multiple valve replacements were excluded from our cohort. Baseline clinical, perioperative, and follow-up data were recorded prospectively. The mean follow-up was 8.6 ± 5.9 years, for a total of 3,299 valve-years. Follow-up was complete for 95.3% of patients included. RESULTS: Operative mortality rate was 1.3%. Eighty-five late deaths occurred, for a linearized rate of 2.6%/valve-year. Actuarial survival rates averaged 78.1% ± 2.6%, 65.6% ± 3.5%, and 46.8% ± 6.0% after 10, 15, and 20 years of follow-up, respectively. Mortality rate associated with reoperation was 2.3%. Actuarial freedom from reoperation rates attributable to structural valve deterioration at 10, 15, and 20 years were, respectively, 88.3% ± 2.4%, 70.8% ± 4.1%, and 38.1% ± 5.6%. Competing risk analysis demonstrated an actual risk of explantation secondary to structural valve deterioration at 20 years of 41.6% ± 4.1%. Expected valve durability was 17.6 years for this age group. CONCLUSIONS: In selected patients 60 years or younger undergoing aortic valve replacement with the Carpentier-Edwards Perimount bioprosthesis, the expected valve durability was 17.6 years. Reoperation for structural valve deterioration was associated with a low risk of mortality.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Adolescent , Adult , Age Factors , Female , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Retrospective Studies , Time Factors , Treatment Outcome , Young Adult
6.
Eur Heart J ; 36(28): 1822-30, 2015 Jul 21.
Article in English | MEDLINE | ID: mdl-25994754

ABSTRACT

AIMS: The CHA2DS2VASc score is a clinical risk stratification tool which estimates the risk of stroke and thromboembolism in non-valvular atrial fibrillation (AF). We aimed to establish the value of this score for risk evaluation in patients with non-valvular AF and valvular heart disease. METHODS AND RESULTS: Among 8053 patients with non-valvular AF (ESC guidelines definition), patients were categorized into Group 1 (no valve disease, n = 6851; 85%) and Group 2 (valve disease with neither rheumatic mitral stenosis nor valve prothesis, n = 1202; 15%). After follow-up of 868 ± 1043 days, 627 stroke/ thromboembolic (TE) events were recorded. Group 2 was significantly older, had a higher CHA2DS2VASc score and had a higher risk of thromboembolic events [hazard ratio (HR) 1.39; 95% CI 1.14-1.69, P = 0.001] compared with Group 1. Severe valve disease was not associated with worse prognosis for stroke/TE events. In the two groups, stroke/TE risk increased with a higher CHA2DS2VASc score. Factors independently associated with increased risk of stroke/TE events were older age (HR 1.25, 95% CI 1.14-1.36 per 10-year increase, P < 0.0001) and higher CHA2DS2VASc score (HR 1.33, 95% CI 1.23-1.45, P < 0.0001). The predictive value (c-statistic) of the CHA2DS2VASc score was similar in the two groups. CONCLUSION: In patients with non-valvular AF, left-sided valvular heart disease (excluding mitral stenosis and protheses) was associated with an increased risk of stroke/TE events. A higher CHA2DS2VASc score in these patients is likely to explain these results.


Subject(s)
Atrial Fibrillation/mortality , Heart Valve Diseases/mortality , Severity of Illness Index , Aged , Atrial Fibrillation/complications , Female , Heart Valve Diseases/complications , Humans , Kaplan-Meier Estimate , Male , Prognosis , Risk Assessment/methods , Stroke/etiology , Stroke/mortality , Thromboembolism/etiology , Thromboembolism/mortality
7.
Ann Thorac Surg ; 99(3): 831-7, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25583467

ABSTRACT

BACKGROUND: The Carpentier-Edwards Perimount pericardial bioprosthesis (Edwards Lifesciences, Irvine, CA) has demonstrated good long-term outcomes, but its durability remains unclear depending on age at implantation. We report our 20-year experience with the Perimount valve implanted in the aortic position, with particular attention to the probability and time to reoperation required due to bioprosthesis deterioration. METHODS: From 1984 to 2008 at our center, 2,659 patients (mean age, 70.7 ± 10.4 years) underwent aortic valve replacement using the Perimount pericardial bioprostheses. Patients were prospectively followed on an annual basis (mean 6.7 ± 4.8 years, range 0 to 24.6 years) with an echocardiogram at the time of follow-up. Cumulative follow-up was 18,404 valve-years. Bioprosthesis structural valve deterioration was determined by strict echocardiographic assessment. RESULTS: Overall operative mortality was 2.8%. Actuarial survival rates including early deaths averaged 52.4% ± 1.2%, 31.1% ± 1.4%, and 14.4% ± 1.7% after 10, 15, and 20 years of follow-up, respectively. Age-stratified freedom from reoperation due to structural valve deterioration at 15 and 20 years was 70.8% ± 4.1% and 38.1% ± 5.6%, respectively, for the group aged 60 years or less, 82.7% ± 2.9% and 59.6% ± 7.6% for those 60 to 70 years, and 98.1% ± 0.8% at 15 years and above for the oldest group. Expected valve durability is 19.7 years for the entire cohort. CONCLUSIONS: With a low rate of valve-related events at 20 years, and particularly a low rate of structural valve deterioration, the Carpentier-Edwards Perimount pericardial bioprosthesis remains a reliable choice for a tissue valve in the aortic position, especially in patients over 60 years of age.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Prosthesis Failure , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prosthesis Design , Reoperation/statistics & numerical data , Retrospective Studies , Time Factors , Treatment Outcome , Young Adult
8.
Ann Vasc Surg ; 28(7): 1796.e5-7, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24911804

ABSTRACT

Radiation-induced stenosis of the carotid artery is considered a challenging entity for direct revascularization. We performed a carotid artery stenting for a radiation-induced stenosis using a transapical approach on an asymptomatic 63-year-old male patient. Transapical approach, which is often used for cardiac surgery, was not yet described for the endovascular treatment of carotid stenosis. The transapical approach could be an attractive alternative path for patients presenting significant supra-aortic trunks lesions and unfit for direct approach or peripheral access. This case reports the feasibility and the safety of carotid artery stenting using the transapical approach in well-trained teams.


Subject(s)
Carotid Arteries/radiation effects , Carotid Stenosis/etiology , Carotid Stenosis/therapy , Laryngeal Neoplasms/radiotherapy , Stents , Carotid Stenosis/diagnostic imaging , Humans , Male , Middle Aged , Tomography, X-Ray Computed , Tracheostomy
9.
J Thorac Cardiovasc Surg ; 148(5): 2004-2011.e1, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24667021

ABSTRACT

OBJECTIVE: The aim of the present study was to evaluate the very-long-term results of the Carpentier-Edwards pericardial bioprosthesis in the mitral position. METHODS: From 1984 to 2011, 450 Carpentier-Edwards PERIMOUNT pericardial mitral bioprostheses were implanted in 404 consecutive patients (mean age, 68 years; 53% female). Patients undergoing multiple valve replacements were excluded. The clinical, operative, and follow-up data were prospectively recorded. The mean follow-up was 7.2±5.1 years, for a total of 3258 valve-years. The follow-up data were 97.8% complete. RESULTS: The operative mortality rate was 3.3%. A total of 188 late deaths occurred, for a linearized rate of 5.8%/valve-year. At 20 years, the overall actuarial survival rate was 16.9%±3.9%. Age at implantation, preoperative New York Heart Association class III or IV, and redo procedure were significant risk factors affecting late survival. The actuarial freedom from complications at 20 years was thromboembolism, 83.9%±7.6%; hemorrhage, 80.2%±10.8%; endocarditis, 94.8%±1.4%; structural valve deterioration, 23.7%±6.9%; and explantation owing to structural valve deterioration, 40.5%±8.0%. The competing risk analysis demonstrated an actual risk of explantation owing to structural valve deterioration at 20 years of 25.5%±2.9%. The expected valve durability was 16.6 years for the entire cohort (11.4, 16.6, and 19.4 years for patients aged <60, 60 to 70, and >70 years, respectively). CONCLUSIONS: With a low rate of valve-related events at 20 years and, in particular, a low rate of structural valve deterioration, the Carpentier-Edwards PERIMOUNT pericardial bioprosthesis remains a reliable choice for a mitral tissue valve, especially in patients >60 years old.


Subject(s)
Bioprosthesis , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve/surgery , Adult , Age Factors , Aged , Aged, 80 and over , Female , Heart Valve Diseases/diagnosis , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hospital Mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Patient Selection , Postoperative Complications/mortality , Postoperative Complications/surgery , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Young Adult
11.
Ann Thorac Surg ; 93(1): 331-3, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22186467

ABSTRACT

We propose a complete surgical approach by left retropectoral transaxillary implantation with no vein puncture to improve the aesthetic and psychological tolerance of the implantable cardioverter defibrillator and avoid the pneumothorax and the subclavian crush syndrome.


Subject(s)
Axilla/surgery , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Heart Diseases/therapy , Adult , Female , Follow-Up Studies , Humans
12.
Asian Cardiovasc Thorac Ann ; 19(1): 14-9, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21357312

ABSTRACT

Data of 401 patients who underwent mitral valve replacement with the Carpentier-Edwards Perimount bioprosthesis between 1984 and 2009 were evaluated. Their mean age was 68.1 ± 10.4 years (range, 22-90 years) and 54.9% were female. The most common etiology was degenerative disease (33.2%) and 62.1% of patients had mitral insufficiency. Follow-up was 3,178 patient-years, and 96.8% complete; the mean follow-up was 8.9 ± 3.1 years. Overall survival at 25 years was 10.2% ± 3%. Late mortality was 2.48% per patient-year, and valve-related deaths occurred at 1.62% per patient-year. The actuarial freedom from reoperation due to structural valve deterioration at 20 years was 24.3% ± 2% for degenerative disease and 15% ± 1.4% for non-degenerative disease. For degenerative valve disease, the freedom from structural valve deterioration at 18-years was 39% ± 1% for recipients <60-years old and 66% ± 2% for those ≥60-years old. Our data confirm the excellent durability and low mortality associated with the Carpentier-Edwards Perimount for mitral valve replacement. The rate of calcification of the valve was unrelated to degenerative valve disease, but our findings suggest that this prosthesis gives better results in recipients ≥60-years old than in younger patients.


Subject(s)
Bioprosthesis , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve/surgery , Adult , Age Factors , Aged , Aged, 80 and over , Chi-Square Distribution , Disease-Free Survival , Female , France , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Design , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Survival Rate , Time Factors , Treatment Outcome , Young Adult
13.
J Heart Valve Dis ; 20(6): 673-80, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22655498

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: Currently, valve thrombosis, thromboembolic events and bleeding events account for 75% of all complications that occur after mechanical heart valve replacement. The study aim was to determine the main risk factors for valve-related complications in patients undergoing mechanical heart valve replacement. METHODS: Data were available from the systematic follow up of patients who had received a CarboMedics bileaflet mechanical heart valve replacement at the authors' institution. Follow up examinations were conducted prospectively at two-year intervals, via questionnaires sent to the patients' general practitioners, or by telephone calls. RESULTS: Between January 1988 and December 2005, a total of 505 consecutive patients (300 males, 205 females; mean age 52 years; range: 5 to 77 years) underwent heart valve replacement using a CarboMedics mechanical prosthesis. Aortic valve replacement (AVR) was performed in 308 patients, mitral valve replacement (MVR) in 134 patients, and double-valve replacement (DVR) in 62 patients. The follow up was 95.4% complete; the mean follow up was 7.5 years, and the total follow up 3,718 patient-years. Thromboembolic and bleeding complications represented the leading cause of valve-related events (104/195), of valve-related mortality (15/25), and of the need for repeat surgery (9/16). Valve thrombosis occurred in 12 patients. Implantation in the mitral position was identified as a risk factor (HR = 15.07; CI: 8.41-23.07; p 0.0001). Thromboembolism occurred in 32 patients; the use of antiplatelet agents was found to be a protective factor (HR = 0.23; CI: 0.08-0.70; p = 0.01). Bleeding events occurred in 52 patients; risk factors for bleeding events included a history of thromboembolic or bleeding complications (HR = 2.70; CI: 1.33-5.26; p = 0.006) and an unstable International Normalized Ratio (INR) (HR = 2.86; CI: 1.01-8.08; p = 0.05). CONCLUSION: After mechanical heart valve replacement, the only risk factors for bleeding complications were an unstable INR and a history of thromboembolic or bleeding events. The use of antiplatelet agents proved to be a protective factor against thromboembolic events.


Subject(s)
Heart Valve Prosthesis Implantation , Postoperative Complications/mortality , Adolescent , Adult , Aged , Child , Child, Preschool , Female , Follow-Up Studies , France/epidemiology , Hemorrhage/epidemiology , Humans , Male , Middle Aged , Reoperation , Risk Factors , Thrombosis/epidemiology , Young Adult
14.
Stem Cells Dev ; 17(6): 1131-40, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19006452

ABSTRACT

Previous studies have suggested that mesenchymal stem cells (MSCs) can differentiate into smooth muscle-like cells. However their functionalities remain questionable. The aim of this study was to investigate the functionality of MSCs differentiated into smooth muscle (SM) in vitro by SM-inducing medium. MSCs have been isolated from rat bone marrow and cultured in SM-inducing medium. After 21 days in culture, messenger RNA and specific SM proteins such as myosin heavy chain and myosin light chain 2 were expressed in the in vitro differentiated MSCs to a similar level of that in freshly isolated SM cells (SMCs). At the electrophysiological level, MSCs presented an outward K+ current with an IK(DR) component and IK(Ca) component. In vitro differentiation induced an enhancement of the IK(Ca) current to a level similar to that observed in aortic SMCs. Calcium homeostasis measurements revealed that both differentiated and undifferentiated MSCs responded to extracellular adenosine triphosphate (ATP) in a similar fashion to SMCs. However MSCs failed to contract in response to ATP. This data shows that despite specific SM protein expression and modification of electrophysiological properties similar to that of aortic SMCs, MSCs cultured in differentiation medium failed to display contractile properties. These results underline the necessity to find the ideal cultured conditions to induce complete SMC function.


Subject(s)
Cell Differentiation/physiology , Membrane Potentials/physiology , Mesenchymal Stem Cells/metabolism , Muscle, Smooth, Vascular/metabolism , Myocytes, Smooth Muscle/metabolism , Adenosine Triphosphate/pharmacology , Animals , Calcium/metabolism , Cardiac Myosins/biosynthesis , Cell Differentiation/drug effects , Cells, Cultured , Homeostasis/physiology , Membrane Potentials/drug effects , Mesenchymal Stem Cells/cytology , Muscle, Smooth, Vascular/cytology , Myocytes, Smooth Muscle/cytology , Myosin Heavy Chains/biosynthesis , Myosin Light Chains/biosynthesis , Rats , Time Factors
15.
J Vasc Surg ; 47(6): 1313-21, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18329228

ABSTRACT

BACKGROUND: We evaluated the possibility of restoring a physiologic vascular wall using undifferentiated mesenchymal stem cells (MSCs) seeded on a polyurethane vascular prosthesis. METHODS: Undifferentiated MSCs were seeded on a vascular prosthesis and implanted into Wistar male rats (weight, 350 g) to investigate differentiation into smooth muscle cells and to determine graft endothelialization in vivo. RESULTS: Seeded or nonseeded grafts were surgically implanted. Undifferentiated MSCs were first labelled for green fluorescent protein. After 2 weeks in vivo, MSC that were initially self-expanded on the graft in a monolayer were organized in a multicellular layer mimicking media of aortic adjacent wall. They coexpressed green fluorescent protein and smooth muscle proteins that were not present before the in vivo engraftment, indicating that in vivo conditions induced smooth muscle protein maturation. Undifferentiated MSC showed an electrophysiologic profile quite different than mature smooth muscle cells. In both in vitro- and in vivo-differentiated MSCs, adenosine triphosphate, an IP(3)-dependent agonist, induced an increase in calcium similar to that which occurred in mature smooth muscle cells. However, MSCs failed to respond to caffeine, a ryanodine receptor activator, indicating the absence of mature calcium signaling, and finally, contraction was absent. Endothelialization attested by immunohistology and scanning electron microscopy was greater in MSC-seeded grafts that prevent thrombosis. CONCLUSION: Only partial smooth muscle cell differentiation of MSCs resulted when seeded on vascular grafts, but MSCs spontaneously restore a media-like thick wall. Mesenchymal stem cells have a positive impact on in vivo endothelialization in rats that supports their potential for use in vascular surgery. CLINICAL RELEVANCE: Thrombosis of vascular prostheses is a major complication of surgery. We showed on rat aorta that mesenchymal stem cells seeded on polyurethane patch restore endothelium. It also induced incomplete smooth muscle differentiation. In the future, stem cell could prevent thrombosis of vascular prostheses.


Subject(s)
Aorta/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Cell Differentiation , Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/metabolism , Adenosine Triphosphate/metabolism , Animals , Aorta/drug effects , Aorta/metabolism , Aorta/ultrastructure , Caffeine/pharmacology , Calcium Signaling , Cell Proliferation , Cells, Cultured , Endothelium, Vascular/metabolism , Endothelium, Vascular/surgery , Green Fluorescent Proteins/genetics , Green Fluorescent Proteins/metabolism , Male , Membrane Potentials , Mesenchymal Stem Cells/drug effects , Mesenchymal Stem Cells/ultrastructure , Muscle Proteins/metabolism , Muscle, Smooth, Vascular/metabolism , Muscle, Smooth, Vascular/surgery , Phenotype , Polyurethanes , Prosthesis Design , Rats , Rats, Wistar , Time Factors , Transfection , Vasoconstriction
16.
J Heart Valve Dis ; 15(6): 768-75; discussion 775-6, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17152784

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: Aortic stenosis (AS) is the most important cause of aortic valve disease, its prevalence increasing with patient age. The present study formed part of a long-term evaluation on use of the Perimount pericardial valve for aortic calcified stenosis. METHODS: A total of 1133 consecutive patients who underwent aortic valve replacement (AVR) with a Perimount pericardial bioprosthesis for degenerative AS between July 1984 and December 2003 at the authors' institution, was followed up in 2004. Among the patients (716 males, 417 females; mean age 72.6 years), 997 were in sinus rhythm, and the mean NYHA functional class was 2.3. Preoperative echocardiography indicated a mean gradient of 56 mmHg, a peak gradient of 89 mmHg, and an effective orifice area of 0.6 cm2. Associated procedures were required in 336 patients. RESULTS: All patients but 18 (1.5%) were followed up for an average of 5.5 years postoperatively; thus, the total follow up was 6,180 patient-years. Operative mortality was 2.8% (n=32), and there were 330 late deaths. At 18 years the actuarial survival rate was 22 +/- 4%. Among the 725 patients followed, 80% were in sinus rhythm and 98% in NYHA classes I or II. Valve-related complications included 39 thromboembolic episodes, 24 endocarditis, 22 anticoagulant-related hemorrhage, 28 reoperations, and 19 structural valve failures. A total of 54 patients died from valve-related causes (13 embolic events, two endocarditis, two hemorrhage, one structural failure, 36 unknown causes), and 57 died from cardiac failure. Neither thrombosis nor hemolysis was observed. At 18 years, freedom from embolism was 92 +/- 2%, from endocarditis 93 +/- 4%, from hemorrhage 95 +/- 2%, from reoperation 62 +/- 11%, from valve failure 68 +/- 12%, and from all complications 47 +/- 8%. Among patients aged >60 years, the 18-year actuarial freedom from reoperation was 76 +/- 14%, and from valve failure 85 +/- 8%. CONCLUSION: With a low rate of valve-related events at 18 years, and an especially low rate of structural failure, the Perimount pericardial prosthesis is a reliable choice for patients with aortic calcified stenosis.


Subject(s)
Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis/statistics & numerical data , Calcinosis/mortality , Calcinosis/surgery , Heart Valve Prosthesis/statistics & numerical data , Adult , Aged , Aged, 80 and over , Equipment Failure Analysis , Female , France/epidemiology , Humans , Longitudinal Studies , Male , Middle Aged , Prosthesis Design , Risk Assessment/methods , Risk Factors , Survival Analysis , Survival Rate , Treatment Outcome
17.
Toxicol Sci ; 85(2): 976-82, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15746005

ABSTRACT

We hypothesized that inhalation of carbon monoxide (CO) (500 ppm), similar to that in tobacco smoke, disturbs the cardiovascular adaptation after myocardial infarction by increasing remodeling. Four groups of rats were assessed. Two groups had myocardial infarction induced by the ligation of the left coronary artery: the first group was exposed to air (infarcted air group, n = 12), and the second was exposed to CO (infarcted CO group, n = 11). They were compared to two sham-operated groups, a control air group (n = 10), and a control CO group (n = 7) exposed (3 weeks) to CO. Aerobic endurance capacity was assessed in both the infarct CO and infarct air group (endurance capacity = 0.043 +/- 0.006 m.min(-1).g(-1) vs. 0.042 +/- 0.005 m.min(-1).g(-1), not significant). In the infarcted CO group compared to the infarcted air group, the dilatation of the left ventricle observed 3 weeks after infarction was increased, (left ventricular diastolic (LVD) diameter (D) = 9 +/- 0.4 vs. 7 +/- 0.4 mm, p < 0.05; left ventricular systolic (LVS) diameter (D) = 6 +/- 0.6 vs. 4.1 +/- 0.4, p < 0.05), and the diastolic posterior wall thickness was augmented (posterior wall diastolic thickness = 1.7 +/- 0.1 vs. 1.3 +/- 0.1 mm, p < 0.05). Hemodynamic pressure measurements in both ventricles and pulmonary artery showed elevated diastolic pressure after CO exposure compared to air exposure (LVD pressure = 32 +/- 1.6 vs. 19 +/- 2.3 mm Hg, p < 0.05; right ventricular diastolic pressure = 16 +/- 1.6 vs. 8.6 +/- 1.6 mm Hg, p < 0.05; pulmonary arterial pressure in diastole (PAD) = 27 +/- 1.6 vs. 20 +/- 2.3 mm Hg, p < 0.05). In the infarcted CO group, the infarct size increased. Echocardiography and histology showed hypertrophy of the contralateral wall similar to that observed in the noninfarcted control CO group. In conclusion, chronic CO inhalation worsens heart failure in rats with myocardial infarction by an increase in the infarct size and hypertrophy remodeling.


Subject(s)
Carbon Monoxide/toxicity , Myocardial Infarction/pathology , Myocardium/pathology , Smoking/pathology , Ventricular Remodeling/drug effects , Administration, Inhalation , Animals , Blood Pressure/physiology , Cardiomegaly/physiopathology , Echocardiography , Heart/physiopathology , Heart Failure/pathology , Heart Failure/physiopathology , Heme Oxygenase (Decyclizing)/biosynthesis , Hemodynamics/drug effects , Immunohistochemistry , Male , Myocardial Infarction/physiopathology , Physical Endurance/drug effects , Rats , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL