Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
PLoS One ; 19(5): e0298919, 2024.
Article in English | MEDLINE | ID: mdl-38805442

ABSTRACT

BACKGROUND: A simple treated fabric device for passively emanating the volatile pyrethroid transfluthrin was recently developed in Tanzania that protected against nocturnal Anopheles and Culex mosquitoes for several months. Here these transfluthrin emanators were assessed in Port-au-Prince, Haiti against outdoor-biting Aedes. METHODS: Transfluthrin emanators were distributed to participating households in poor-to-middle class urban neighbourhoods and evaluated once every two months in terms of their effects on human landing rates of wild Aedes populations. A series of three such entomological assessment experiments were conducted, to examine the influence of changing weather conditions, various transfluthrin formulations and emanator placement on protective efficacy measurements. Laboratory experiments assessed resistance of local Aedes aegypti to transfluthrin and deltamethrin, and the irritancy and repellency of the transfluthrin-treated fabric used in the field. RESULTS: Across all three entomological field assessments, little evidence of protection against wild Ae. aegypti was observed, regardless of weather conditions, transfluthrin formulation or emanator placement: A generalized linear mixed model fitted to the pooled data from all three assessment rounds (921 females caught over 5129 hours) estimated a relative landing rate [95% Confidence interval] of 0.87 [0.73, 1.04] for users of treated versus untreated emanators (P = 0.1241). Wild Ae. aegypti in this setting were clearly resistant to transfluthrin when compared to a fully susceptible colony. CONCLUSIONS: Transfluthrin emanators had little if any apparent effect upon Aedes landing rates by wild Ae. aegypti in urban Haiti, and similar results have been obtained by comparable studies in Tanzania, Brazil and Peru. In stark contrast, however, parallel sociological assessments of perspectives among these same end-users in urban Haitian communities indicate strong satisfaction in terms of perceived protection against mosquitoes. It remains unclear why the results obtained from these complementary entomological and sociological assessments in Haiti differ so much, as do those from a similar set of studies in Brazil. It is encouraging, however, that similar contrasts between the entomological and epidemiological results of a recent large-scale assessment of another transfluthrin emanator product in Peru, which indicate they provide useful protection against Aedes-borne arboviral infections, despite apparently providing only modest protection against Aedes mosquito bites.


Subject(s)
Aedes , Cyclopropanes , Fluorobenzenes , Insecticides , Mosquito Control , Animals , Aedes/drug effects , Cyclopropanes/pharmacology , Haiti , Mosquito Control/methods , Humans , Insecticides/pharmacology , Female , Pyrethrins/pharmacology , Mosquito Vectors/drug effects , Insecticide Resistance , Insect Bites and Stings/prevention & control , Nitriles/pharmacology , Family Characteristics , Insect Repellents/pharmacology
2.
PLoS One ; 19(5): e0299722, 2024.
Article in English | MEDLINE | ID: mdl-38809841

ABSTRACT

BACKGROUND: A low technology emanator device for slowly releasing vapour of the volatile pyrethroid transfluthrin was recently developed in Tanzania that provides robust protection against night biting Anopheles and Culex vectors of malaria and filariasis for several months. Here these same emanator devices were assessed in Dar es Salaam city, as a means of protection against outdoor-biting Aedes (Stegomia) aegypti, the most important vector of human arboviruses worldwide, in parallel with similar studies in Haiti and Brazil. METHODS: A series of entomological experiments were conducted under field and semi-field conditions, to evaluate whether transfluthrin emanators protect against wild Ae. aegypti, and also compare the transfluthrin responsiveness of Ae. aegypti originating from wild-caught eggs to established pyrethroid-susceptible Ae. aegypti and Anopheles gambiae colonies. Preliminary measurements of transfluthrin vapour concentration in air samples collected near treated emanators were conducted by gas chromatography-mass spectrometry. RESULTS: Two full field experiments with four different emanator designs and three different transfluthrin formulations consistently indicated negligible reduction of human landing rates by wild Ae. aegypti. Under semi-field conditions in large cages, 50 to 60% reductions of landing rates were observed, regardless of which transfluthrin dose, capture method, emanator placement position, or source of mosquitoes (mildly pyrethroid resistant wild caught Ae. aegypti or pyrethroid-susceptible colonies of Ae. aegypti and An. gambiae) was used. Air samples collected immediately downwind from an emanator treated with the highest transfluthrin dose (15g), contained 12 to 19 µg/m3 transfluthrin vapour. CONCLUSIONS: It appears unlikely that the moderate levels of pyrethroid resistance observed in wild Ae. aegypti can explain the modest-to-undetectable levels of protection exhibited. While potential inhalation exposure could be of concern for the highest (15g) dose evaluated, 3g of transfluthrin appears sufficient to achieve the modest levels of protection that were demonstrated entomologically. While the generally low levels of protection against Aedes reported here from Tanzania, and from similar entomological studies in Haiti and Brazil, are discouraging, complementary social science studies in Haiti and Brazil suggest end-users perceive valuable levels of protection against mosquitoes. It therefore remains unclear whether transfluthrin emanators have potential for protecting against Aedes vectors of important human arboviruses.


Subject(s)
Aedes , Cyclopropanes , Fluorobenzenes , Insecticides , Mosquito Control , Animals , Tanzania , Aedes/drug effects , Cyclopropanes/pharmacology , Mosquito Control/methods , Insecticides/pharmacology , Mosquito Vectors/drug effects , Humans , Anopheles/drug effects , Insect Bites and Stings/prevention & control , Pyrethrins
3.
Commun Med (Lond) ; 4(1): 15, 2024 Feb 05.
Article in English | MEDLINE | ID: mdl-38316912

ABSTRACT

BACKGROUND: Chronic kidney disease (CKD) affects 10% of the global population costing over a hundred billion dollars per annum and leading to increased risk of cardiovascular disease. Many patients with CKD require regular haemodialyses. Synthetic arteriovenous grafts (AVG) are increasingly used to provide rapid vascular connection for dialysis. Initially, they have excellent patency rates but are critically limited by neointimal hyperplasia at the venous anastomosis, which drives subsequent thrombosis, graft failure and death. METHODS: Here, we describe a system in which electrical impedance spectroscopy sensors are incorporated circumferentially into the wall of a synthetic arteriovenous graft. This is combined with an implantable radiotelemetry system for data transmission outside the patient. The system was tested using monolayers of endothelial and smooth muscle cells as well as swine blood and clots with explanted human carotid artery plaques. Sensor testing was then performed in vitro and the device was implanted in vivo in female swine. RESULTS: The device can wirelessly report the accumulation of biological material, both cells and blood. Differences are also detected when comparing controls with pathological atheroma. In swine differences between blockage formation in a graft were remotely obtained and wireless reported. CONCLUSIONS: Combining electrical impedance spectroscopy and an implantable radiotelemetry system enables graft surveillance. This has the potential to be used for early detection of venous stenosis and blood clot formation in real-time in vivo. In principle, the concept could apply to other cardiovascular diseases and vascular implantable devices.


Chronic kidney disease is common throughout the world and required treatments are expensive. People with chronic kidney disease require frequent blood dialysis treatment to filter their blood and remove waste products and toxic substances circulating in the blood. For some patients, implantable tubular structures called AV grafts are used for providing access to dialysis. These grafts frequently block sometimes without warning leading to patients not being able to undergo dialysis. Through a series of laboratory experiments looking at cells that block the graft, fatty deposits and blood clots, we evaluated whether sensors could detect blockages in an AV graft. We also tested the device in an animal model. From these results we were able to show that our device could detect blockages within a graft. In the future we hope that introduction to the clinic of an optimized version of our device will reduce costs to healthcare systems and improve patient outcomes.

4.
Adv Sci (Weinh) ; 11(21): e2304748, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38342628

ABSTRACT

Many cardiovascular problems stem from blockages that form within the vasculature and often treatment includes fitting a stent through percutaneous coronary intervention. This offers a minimally invasive therapy but re-occlusion through restenosis or thrombosis formation often occurs post-deployment. Research is ongoing into the creation of smart stents that can detect the occurrence of further problems. In this study, it is shown that selectively metalizing a non-conductive stent can create a set of electrodes that are capable of detecting a build-up of material around the stent. The associated increase in electrical impedance across the electrodes is measured, testing the stent with blood clot to mimic thrombosis. It is shown that the device is capable of sensing different amounts of occlusion. The stent can reproducibly sense the presence of clot showing a 16% +/-3% increase in impedance which is sufficient to reliably detect the clot when surrounded by explanted aorta (one sample t-test, p = 0.009, n = 9). It is demonstrated that this approach can be extended beyond the 3D printed prototypes by showing that it can be applied to a commercially available stent and it is believed that it can be further utilized by other types of medical implants.


Subject(s)
Biosensing Techniques , Stents , Thrombosis , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Thrombosis/diagnosis , Humans , Animals , Electric Impedance
5.
Mar Pollut Bull ; 192: 115105, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37290299

ABSTRACT

Artificial Light at Night (ALAN) is a common environmental pollutant which affects >22 % of the world's coastlines. However, the impact of ALAN wavelengths on coastal organisms is under-investigated. Here, we tested the impact of red, green, and white ALAN on the gaping activity and phytoplankton consumption of Mytilus edulis mussels and compared these to dark night. Mussels exhibited a semi-diel activity pattern. Although ALAN did not significantly affect the time open nor the phytoplankton consumption, it did have a colour-specific effect on the gaping frequency with red and white ALAN resulting in lower activity compared to the dark night. Green ALAN caused higher gaping frequency and a negative relationship between consumption and proportion of time open compared to the other treatments. Our findings suggest colour-specific ALAN effects on mussels and call for further investigation on the associated physiological mechanisms and potential ecological consequences.


Subject(s)
Bivalvia , Light Pollution , Animals , Seafood , Light
7.
Parasit Vectors ; 15(1): 420, 2022 Nov 11.
Article in English | MEDLINE | ID: mdl-36369172

ABSTRACT

BACKGROUND: Estimating human exposure to mosquito vectors is crucial for the prediction of malaria transmission and intervention impact. The human landing catch method is frequently used to directly measure estimate exposure rates; however, there has been an increasing shift from this method to exposure-free alternatives, such as the mosquito electrocuting traps (MET) and other approaches. While these latter methods can provide robust and representative values of human exposure and mosquito density, they often still require a human volunteer, which poses logistical challenges. Additionally, in the case of the MET, the early MET prototype (METe) required human volunteers to wear protective clothing that could be uncomfortable. We investigated two alternative trapping approaches to address these challenges by comparing the performance of the METe prototype to: (i) a modified caged MET prototype that offers full protection to users (METc) and (ii) a barrier screen trap (BST) designed to passively sample (host-seeking and blood-fed) mosquitoes outdoors without requiring a human participant. METHODS: The relative performance of the METe, METc and BST were evaluated in a 3 × 3 Latin square field experiment design conducted in south-eastern Tanzania over 12 nights of sampling. The outcomes of interest were the nightly catch of mosquitoes and biting time estimates. RESULTS: The METc and BST caught similar numbers of An. arabiensis as the METe (relative ratio [RR] = 0.76, 95% confidence interval [CI]: 0.42-1.39, P = 0.38 and RR = 1.13, 95% CI: 0.63-2.04, P = 0.69, respectively). Similarly, the METc and BST caught similar numbers of Culex spp. as the METe (RR = 0.87, 95% CI: 0.62-1.22, P = 0.42 and RR = 0.80, 95% CI: 0.57-1.12, P = 0.199, respectively). All three trapping methods indicated a similar pattern of biting activity by An. arabiensis and Culex spp., characterized by biting starting in the early evening (18:00-22:00), peaking when people are typically sleeping (22:00-05:00) and dropping off drastically toward the morning (05:00-07:00). CONCLUSIONS: The modifications made to the METe design to improve user comfort and remove the need for protective clothing did not result in an underestimation of mosquito vector abundance nor misrepresentation of their biting time pattern. We recommend the METc for use over the METe design. Similarly, the BST demonstrated potential for monitoring malaria and filariasis vector densities in Tanzania.


Subject(s)
Anopheles , Culex , Filariasis , Malaria , Nematode Infections , Animals , Humans , Tanzania , Mosquito Vectors , Malaria/prevention & control , Phenotype , Mosquito Control/methods
8.
Adv Sci (Weinh) ; 9(15): e2105285, 2022 05.
Article in English | MEDLINE | ID: mdl-35322587

ABSTRACT

Self-reporting implantable medical devices are the future of cardiovascular healthcare. Cardiovascular complications such as blocked arteries that lead to the majority of heart attacks and strokes are frequently treated with inert metal stents that reopen affected vessels. Stents frequently re-block after deployment due to a wound response called in-stent restenosis (ISR). Herein, an implantable miniaturized sensor and telemetry system are developed that can detect this process, discern the different cell types associated with ISR, distinguish sub plaque components as demonstrated with ex vivo samples, and differentiate blood from blood clot, all on a silicon substrate making it suitable for integration onto a vascular stent. This work shows that microfabricated sensors can provide clinically relevant information in settings closer to physiological conditions than previous work with cultured cells.


Subject(s)
Biosensing Techniques , Coronary Restenosis , Myocardial Infarction , Plaque, Atherosclerotic , Coronary Restenosis/etiology , Coronary Restenosis/metabolism , Coronary Restenosis/therapy , Humans , Myocardial Infarction/complications , Plaque, Atherosclerotic/complications , Stents/adverse effects
9.
IEEE Rev Biomed Eng ; 15: 260-272, 2022.
Article in English | MEDLINE | ID: mdl-34520361

ABSTRACT

Cardiovascular disease (CVD) is a group of heart and vasculature conditions which are the leading form of mortality worldwide. Blood vessels can become narrowed, restricting blood flow, and drive the majority of hearts attacks and strokes. Reactive surgical interventions are frequently required; including percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG). Despite successful opening of vessels and restoration of blood flow, often in-stent restenosis (ISR) and graft failure can still occur, resulting in subsequent patient morbidity and mortality. A new generation of cardiovascular implants that have sensors and real-time monitoring capabilities are being developed to combat ISR and graft failure. Self-reporting stent/graft technology could enable precision medicine-based and predictive healthcare by detecting the earliest features of disease, even before symptoms occur. Bringing an implantable medical device with wireless electronic sensing capabilities to market is complex and often obstructive undertaking. This critical review analyses the obstacles that need to be overcome for self-reporting stents/grafts to be developed and provide a precision-medicine based healthcare for cardiovascular patients. Here we assess the latest research and technological advancement in the field, the current devices; including smart cardiovascular implantable biosensors and associated wireless data and power transfer solutions. We include an evaluation of devices that have reached clinical trials and the market potential for their end-user implementation.


Subject(s)
Cardiovascular Diseases , Percutaneous Coronary Intervention , Cardiovascular Diseases/surgery , Coronary Artery Bypass , Heart , Humans , Stents
10.
Proc Biol Sci ; 288(1953): 20210525, 2021 06 30.
Article in English | MEDLINE | ID: mdl-34157871

ABSTRACT

Artificial light at night (ALAN) is a disruptive form of pollution, impacting physiological and behavioural processes that may scale up to population and community levels. Evidence from terrestrial habitats show that the severity and type of impact depend on the wavelength and intensity of ALAN; however, research on marine organisms is still limited. Here, we experimentally investigated the effect of different ALAN colours on marine primary producers. We tested the effect of green (525 nm), red (624 nm) and broad-spectrum white LED ALAN, compared to a dark control, on the green microalgae Tetraselmis suesica and a diatom assemblage. We show that green ALAN boosted chlorophyll production and abundance in T. suesica. All ALAN wavelengths affected assemblage biomass and diversity, with red and green ALAN having the strongest effects, leading to higher overall abundance and selective dominance of specific diatom species, some known to cause harmful algal blooms. Our findings show that green and red ALAN should be used with caution as alternative LED colours in coastal areas, where there might be a need to strike a balance between the effects of green and red light on marine primary producers with the benefit they appear to bring to other organisms.


Subject(s)
Environmental Pollution , Phytoplankton , Ecosystem , Light
11.
Adv Sci (Weinh) ; 7(18): 1902999, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32999823

ABSTRACT

Cardiovascular diseases remain a significant global burden with 1-in-3 of all deaths attributable to the consequences of the disease. The main cause is blocked arteries which often remain undetected. Implantable medical devices (IMDs) such as stents and grafts are often used to reopen vessels but over time these too will re-block. A vascular biosensor is developed that can report on cellularity and is amenable to being mounted on a stent or graft for remote reporting. Moreover, the device is designed to also receive currents that can induce a controlled form of cell death, apoptosis. A combined diagnostic and therapeutic biosensor would be transformational for the treatment of vascular diseases such as atherosclerosis and central line access. In this work, a cell sensing and cell apoptosing system based on the same interdigitated electrodes (IDEs) is developed. It is shown that the device is scalable and that by miniaturizing the IDEs, the detection sensitivity is increased. Apoptosis of vascular smooth muscle cells is monitored using continuous impedance measurements at a frequency of 10 kHz and rates of cell death are tracked using fluorescent dyes and live cell imaging.

12.
Parasit Vectors ; 13(1): 31, 2020 Jan 15.
Article in English | MEDLINE | ID: mdl-31941536

ABSTRACT

BACKGROUND: Entomological monitoring of Aedes vectors has largely relied on surveillance of larvae, pupae and non-host-seeking adults, which have been poorly correlated with human disease incidence. Exposure to mosquito-borne diseases can be more directly estimated using human landing catches (HLC), although this method is not recommended for Aedes-borne arboviruses. We evaluated a new method previously tested with malaria vectors, the mosquito electrocuting trap (MET) as an exposure-free alternative for measuring landing rates of Aedes mosquitoes on people. Aims were to (i) compare the MET to the BG-sentinel (BGS) trap gold standard approach for sampling host-seeking Aedes vectors; and (ii) characterize the diel activity of Aedes vectors and their association with microclimatic conditions. METHODS: The study was conducted over 12 days in Quinindé (Ecuador) in May 2017. Mosquito sampling stations were set up in the peridomestic area of four houses. On each day of sampling, each house was allocated either a MET or a BGS trap, which were rotated amongst the four houses daily in a Latin square design. Mosquito abundance and microclimatic conditions were recorded hourly at each sampling station between 7:00-19:00 h to assess variation between vector abundance, trapping methods, and environmental conditions. All Aedes aegypti females were tested for the presence of Zika (ZIKV), dengue (DENV) and chikungunya (CHIKV) viruses. RESULTS: A higher number of Ae. aegypti females were found in MET than in BGS collections, although no statistically significant differences in mean Ae. aegypti abundance between trapping methods were found. Both trapping methods indicated female Ae. aegypti had bimodal patterns of host-seeking, being highest during early morning and late afternoon hours. Mean Ae. aegypti daily abundance was negatively associated with daily temperature. No infection by ZIKV, DENV or CHIKV was detected in any Aedes mosquitoes caught by either trapping method. CONCLUSION: We conclude the MET performs at least as well as the BGS standard and offers the additional advantage of direct measurement of per capita human-biting rates. If detection of arboviruses can be confirmed in MET-collected Aedes in future studies, this surveillance method could provide a valuable tool for surveillance and prediction on human arboviral exposure risk.


Subject(s)
Aedes/physiology , Arbovirus Infections/transmission , Flavivirus/isolation & purification , Insect Bites and Stings/epidemiology , Mosquito Vectors/physiology , Adult , Aedes/virology , Animals , Chikungunya Fever/transmission , Chikungunya virus/isolation & purification , Culex/physiology , Dengue/transmission , Dengue Virus/isolation & purification , Ecuador/epidemiology , Female , Humans , Male , Middle Aged , Mosquito Vectors/virology , Zika Virus/isolation & purification , Zika Virus Infection/transmission
13.
Malar J ; 18(1): 386, 2019 Dec 02.
Article in English | MEDLINE | ID: mdl-31791336

ABSTRACT

BACKGROUND: Measuring human exposure to mosquito bites is a crucial component of vector-borne disease surveillance. For malaria vectors, the human landing catch (HLC) remains the gold standard for direct estimation of exposure. This method, however, is controversial since participants risk exposure to potentially infected mosquito bites. Recently an exposure-free mosquito electrocuting trap (MET) was developed to provide a safer alternative to the HLC. Early prototypes of the MET performed well in Tanzania but have yet to be tested in West Africa, where malaria vector species composition, ecology and behaviour are different. The performance of the MET relative to HLC for characterizing mosquito vector population dynamics and biting behaviour in Burkina Faso was evaluated. METHODS: A longitudinal study was initiated within 12 villages in Burkina Faso in October 2016. Host-seeking mosquitoes were sampled monthly using HLC and MET collections over 14 months. Collections were made at 4 households on each night, with METs deployed inside and outside at 2 houses, and HLC inside and outside at another two. Malaria vector abundance, species composition, sporozoite rate and location of biting (indoor versus outdoor) were recorded. RESULTS: In total, 41,800 mosquitoes were collected over 324 sampling nights, with the major malaria vector being Anopheles gambiae sensu lato (s.l.) complex. Overall the MET caught fewer An. gambiae s.l. than the HLC (mean predicted number of 0.78 versus 1.82 indoors, and 1.05 versus 2.04 outdoors). However, MET collections gave a consistent representation of seasonal dynamics in vector populations, species composition, biting behaviour (location and time) and malaria infection rates relative to HLC. As the relative performance of the MET was somewhat higher in outdoor versus indoor settings, this trapping method slightly underestimated the proportion of bites preventable by LLINs compared to the HLC (MET = 82.08%; HLC = 87.19%). CONCLUSIONS: The MET collected proportionately fewer mosquitoes than the HLC. However, estimates of An. gambiae s.l. density in METs were highly correlated with HLC. Thus, although less sensitive, the MET is a safer alternative than the HLC. Its use is recommended particularly for sampling vectors in outdoor environments where it is most sensitive.


Subject(s)
Anopheles , Mosquito Control/instrumentation , Mosquito Vectors , Animals , Burkina Faso , Female , Longitudinal Studies , Malaria
14.
Adv Sci (Weinh) ; 6(20): 1900856, 2019 Oct 16.
Article in English | MEDLINE | ID: mdl-31637160

ABSTRACT

Cardiovascular disease is the greatest cause of death worldwide. Atherosclerosis is the underlying pathology responsible for two thirds of these deaths. It is the age-dependent process of "furring of the arteries." In many scenarios the disease is caused by poor diet, high blood pressure, and genetic risk factors, and is exacerbated by obesity, diabetes, and sedentary lifestyle. Current pharmacological anti-atherosclerotic modalities still fail to control the disease and improvements in clinical interventions are urgently required. Blocked atherosclerotic arteries are routinely treated in hospitals with an expandable metal stent. However, stented vessels are often silently re-blocked by developing "in-stent restenosis," a wound response, in which the vessel's lumen renarrows by excess proliferation of vascular smooth muscle cells, termed hyperplasia. Herein, the current stent technology and the future of biosensing devices to overcome in-stent restenosis are reviewed. Second, with advances in nanofabrication, new sensing methods and how researchers are investigating ways to integrate biosensors within stents are highlighted. The future of implantable medical devices in the context of the emerging "Internet of Things" and how this will significantly influence future biosensor technology for future generations are also discussed.

15.
Malar J ; 18(1): 83, 2019 Mar 18.
Article in English | MEDLINE | ID: mdl-30885205

ABSTRACT

BACKGROUND: Mosquito biting rates and host preferences are crucial determinants of human exposure to vector-borne diseases and the impact of vector control measures. The human landing catch (HLC) is a gold standard method for measuring human exposure to bites, but presents risks to participants by requiring some exposure to mosquito vectors. Mosquito electrocuting traps (METs) represent an exposure-free alternative to HLCs for measuring human exposure to malaria vectors. However, original MET prototypes were too small for measuring whole-body biting rates on humans or large animals like cattle. Here a much larger MET capable of encompassing humans or cattle was designed, and its performance was evaluated relative to both the original small MET and HLC and for quantifying malaria vector host preferences. METHODS: Human landing catch, small human-baited METs (MET-SH), and large METs baited with either a human (MET-LH) or calves (MET-LC) were simultaneously used to capture wild malaria vectors outdoors in rural southern Tanzania. The four capture methods were compared in a Latin-square design over 20 nights. Malaria vector host preferences were estimated through comparison of the number of mosquitoes caught by large METs baited with either humans or cattle. RESULTS: The MET-LH caught more than twice as many Anopheles arabiensis than either the MET-SH or HLC. It also caught higher number of Anopheles funestus sensu lato (s.l.) compared to the MET-SH or HLC. Similar numbers of An. funestus sensu stricto (s.s.) were caught in MET-LH and MET-SH collections. Catches of An. arabiensis with human or cattle-baited large METs were similar, indicating no clear preference for either host. In contrast, An. funestus s.s. exhibited a strong, but incomplete preference for humans. CONCLUSIONS: METs are a sensitive, practical tool for assessing mosquito biting rates and host preferences, and represent a safer alternative to the HLC. Additionally these findings suggest the HLC underestimate whole-body human exposure. MET collections indicated the An. funestus s.s. population in this setting had a higher than expected attack rate on cattle, potentially making eliminating of this species more difficult with human-targetted control measures. Supplementary vector control tools targetted at livestock may be required to effectively tackle this species.


Subject(s)
Anopheles/physiology , Entomology/methods , Feeding Behavior , Host Specificity , Adult , Animals , Cattle , Entomology/instrumentation , Female , Humans , Male , Rural Population , Tanzania , Young Adult
16.
Mol Ecol Resour ; 18(2): 240-250, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29091345

ABSTRACT

This study sets out a novel method to determine dispersal distances in lichens. Direct measurement of dispersal often remains difficult for lichens and other small inconspicuous species because of the need to track microscopic reproductive propagules, which even if they can be captured, cannot be identified using traditional morphological approaches. A low-cost device (<£200) was developed to trap the reproductive propagules of lichens, capable of sampling around 0.1 m3 of air per minute. In parallel, molecular techniques were developed to enable species-specific detection of propagules caught by the devices, with identification using novel species-specific primers and optimization of a standard DNA extraction and nested PCR protocol. The methods were tested for both their sensitivity and specificity against a suite of lichen epiphytes, differing in their reproductive mechanisms, dispersal structures and rarity. Sensitivity tests showed that the molecular techniques could detect a single asexual propagule (soredium or isidium), or as few as 10 sexual spores. As proof of concept, propagule traps were deployed into a wooded landscape where the target epiphytes were present. Extractions from deployed propagule traps were sequenced, showing that the method was able to detect the presence of the target species in the atmosphere. As far as we are aware, this is the first attempt to use mechanized propagule traps in combination with DNA diagnostics to detect dispersal of lichens. The tests carried out here point the way for future dispersal studies of lichen epiphytes and other passively dispersed microscopic organisms including fungi or bryophytes.


Subject(s)
Fungi/genetics , Genetics, Population/methods , Lichens/genetics , Plant Dispersal , DNA, Fungal/genetics , DNA, Fungal/isolation & purification , DNA, Plant/genetics , DNA, Plant/isolation & purification , Polymerase Chain Reaction/methods , Sensitivity and Specificity
17.
Malar J ; 15: 465, 2016 Sep 13.
Article in English | MEDLINE | ID: mdl-27618941

ABSTRACT

BACKGROUND: Reliable quantification of mosquito host-seeking behaviours is required to determine the efficacy of vector control methods. For malaria, the gold standard approach remains the risky human landing catch (HLC). Here compare the performance of an improved prototype of the mosquito electrocuting grid trap (MET) as a safer alternative with HLC for measuring malaria vector behaviour in Dar es Salaam, Tanzania. METHODS: Mosquito trapping was conducted at three sites within Dar es Salaam representing a range of urbanicity over a 7-month period (December 2012-July 2013, 168 sampling nights). At each site, sampling was conducted in a block of four houses, with two houses being allocated to HLC and the other to MET on each night of study. Sampling was conducted both indoors and outdoors (from 19:00 to 06:00 each night) at all houses, with trapping method (HLC and MET) being exchanged between pairs of houses at each site using a crossover design. RESULTS: The MET caught significantly more Anopheles gambiae sensu lato than the HLC, both indoors (RR [95 % confidence interval (CI)]) = 1.47 [1.23-1.76], P < 0.0001 and outdoors = 1.38 [1.14-1.67], P < 0.0001). The sensitivity of MET compared with HLC did not detectably change over the course of night for either An. gambiae s.l. (OR [CI]) = 1.01 [0.94-1.02], P = 0.27) or Culex spp. (OR [CI]) = 0.99 [0.99-1.0], P = 0.17) indoors and declined only slightly outdoors: An. gambiae s.l. (OR [CI]) = 0.92 [0.86-0.99], P = 0.04), and Culex spp. (OR [CI]) = 0.99 [0.98-0.99], P = 0.03). MET-based estimates of the proportions of mosquitoes caught indoors (P i ) or during sleeping hours (P fl ), as well as the proportion of human exposure to bites that would otherwise occurs indoors (π i ), were statistically indistinguishable from those based on HLC for An. gambiae s.l. (P = 0.43, 0.07 and 0.48, respectively) and Culex spp. (P = 0.76, 0.24 and 0.55, respectively). CONCLUSIONS: This improved MET prototype is highly sensitive tool that accurately quantifies epidemiologically-relevant metrics of mosquito biting densities, behaviours and human exposure distribution.


Subject(s)
Anopheles/physiology , Culex/physiology , Entomology/methods , Feeding Behavior , Adult , Animals , Cross-Over Studies , Electricity , Female , Humans , Male , Tanzania , Volunteers
19.
Malar J ; 14: 502, 2015 Dec 15.
Article in English | MEDLINE | ID: mdl-26670881

ABSTRACT

BACKGROUND: The human landing catch (HLC) is the gold standard method for sampling host-seeking malaria vectors. However, the HLC is ethically questionable because it requires exposure of humans to potentially infectious mosquito bites. METHODS: Two exposure-free methods for sampling host-seeking mosquitoes were evaluated using electrocuting surfaces as potential replacements for HLC: (1) a previously evaluated, commercially available electrocuting grid (CA-EG) designed for killing flies, and (2) a custom-made mosquito electrocuting trap (MET) designed to kill African malaria vectors. The MET and the CA-EG were evaluated relative to the HLC in a Latin Square experiment conducted in the Kilombero Valley, Tanzania. The sampling consistency of the traps across the night and at varying mosquito densities was investigated. Estimates of the proportion of mosquitoes caught indoors (P(i)), proportion of human exposure occurring indoors (π(i)), and proportion of mosquitoes caught when most people are likely to be indoors (P(fl)) were compared for all traps. RESULTS: Whereas the CA-EG performed poorly (<10% of catch of HLC), sampling efficiency of the MET for sampling Anopheles funestus s.l. was indistinguishable from HLC indoors and outdoors. For Anopheles gambiae s.l., sampling sensitivity of MET was 20.9% (95% CI 10.3-42.2) indoors and 58.5% (95% CI 32.2-106.2) outdoors relative to HLC. There was no evidence of density-dependent sampling by the MET or CA-EG. Similar estimates of P(i) were obtained for An. gambiae s.l. and An. funestus s.l. from all trapping methods. The proportion of mosquitoes caught when people are usually indoors (P(fl)) was underestimated by the CA-EG and MET for An. gambiae s.l., but similar to the HLC for An. funestus. Estimates of the proportion of human exposure occurring indoors (π(i)) obtained from the CA-EG and MET were similar to the HLC for An. gambiae s.l., but overestimated for An. funestus. CONCLUSIONS: The MET showed promise as an outdoor sampling tool for malaria vectors where it achieved >50% sampling sensitivity relative to the HLC. The CA-EG had poor sampling sensitivity outdoors and inside. With further modification, the MET could provide an efficient and safer alternative to the HLC for the surveillance of mosquito vectors outdoors.


Subject(s)
Anopheles/physiology , Electricity , Entomology/instrumentation , Entomology/methods , Animals , Female , Male , Sensitivity and Specificity , Tanzania
SELECTION OF CITATIONS
SEARCH DETAIL
...