Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
Eur J Cancer ; 88: 48-56, 2018 01.
Article in English | MEDLINE | ID: mdl-29190506

ABSTRACT

BACKGROUND: Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. AIM: To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. METHODS: The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). RESULTS: All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. CONCLUSIONS: Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging.


Subject(s)
Breast Density , Breast Neoplasms/diagnosis , Breast/pathology , Early Detection of Cancer/methods , Aged , Body Mass Index , Female , Humans , Logistic Models , Mammography/methods , Middle Aged , Predictive Value of Tests , Prognosis , Risk Factors , United Kingdom
2.
Radiology ; 277(3): 697-706, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26176654

ABSTRACT

PURPOSE: To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. MATERIALS AND METHODS: In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29-85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. RESULTS: Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50-59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). CONCLUSION: The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. (©) RSNA, 2015.


Subject(s)
Breast Neoplasms/diagnosis , Early Detection of Cancer/methods , Imaging, Three-Dimensional/methods , Mammography/methods , Adult , Aged , Diagnostic Errors , Female , Humans , Middle Aged , ROC Curve , Retrospective Studies , United Kingdom
3.
Radiology ; 275(2): 356-65, 2015 May.
Article in English | MEDLINE | ID: mdl-25559234

ABSTRACT

PURPOSE: To evaluate the results from two software tools for measurement of mammographic breast density and compare them with observer-based scores in a large cohort of women. MATERIALS AND METHODS: Following written informed consent, a data set of 36 281 mammograms from 8867 women were collected from six United Kingdom centers in an ethically approved trial. Breast density was assessed by one of 26 readers on a visual analog scale and with two automated density tools. Mean differences were calculated as the mean of all the individual percentage differences between each measurement for each case (woman). Agreement in total breast volume, fibroglandular volume, and percentage density was assessed with the Bland-Altman method. Association with observer's scores was calculated by using the Pearson correlation coefficient (r). RESULTS: Correlation between the Quantra and Volpara outputs for total breast volume was r = 0.97 (P < .001), with a mean difference of 43.5 cm(3) for all cases representing 5.0% of the mean total breast volume. Correlation of the two measures was lower for fibroglandular volume (r = 0.86, P < .001). The mean difference was 30.3 cm(3) for all cases representing 21.2% of the mean fibroglandular tissue volume result. Quantra gave the larger value and the difference tended to increase with volume. For the two measures of percentage volume density, the mean difference was 1.61 percentage points (r = 0.78, P < .001). Comparison of observer's scores with the area-based density given by Quantra yielded a low correlation (r = 0.55, P < .001). Correlations of observer's scores with the volumetric density results gave r values of 0.60 (P < .001) and 0.63 (P < .001) for Quantra and Volpara, respectively. CONCLUSION: Automated techniques for measuring breast density show good correlation, but these are poorly correlated with observer's scores. However automated techniques do give different results that should be considered when informing patient personalized imaging. (©) RSNA, 2015 Clinical trial registration no. ISRCTN 73467396.


Subject(s)
Breast/pathology , Mammography , Software , Aged , Evaluation Studies as Topic , Female , Humans , Mammography/statistics & numerical data , Middle Aged , Observer Variation
4.
Health Technol Assess ; 19(4): i-xxv, 1-136, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25599513

ABSTRACT

BACKGROUND: Digital breast tomosynthesis (DBT) is a three-dimensional mammography technique with the potential to improve accuracy by improving differentiation between malignant and non-malignant lesions. OBJECTIVES: The objectives of the study were to compare the diagnostic accuracy of DBT in conjunction with two-dimensional (2D) mammography or synthetic 2D mammography, against standard 2D mammography and to determine if DBT improves the accuracy of detection of different types of lesions. STUDY POPULATION: Women (aged 47-73 years) recalled for further assessment after routine breast screening and women (aged 40-49 years) with moderate/high of risk of developing breast cancer attending annual mammography screening were recruited after giving written informed consent. INTERVENTION: All participants underwent a two-view 2D mammography of both breasts and two-view DBT imaging. Image-processing software generated a synthetic 2D mammogram from the DBT data sets. RETROSPECTIVE READING STUDY: In an independent blinded retrospective study, readers reviewed (1) 2D or (2) 2D + DBT or (3) synthetic 2D + DBT images for each case without access to original screening mammograms or prior examinations. Sensitivities and specificities were calculated for each reading arm and by subgroup analyses. RESULTS: Data were available for 7060 subjects comprising 6020 (1158 cancers) assessment cases and 1040 (two cancers) family history screening cases. Overall sensitivity was 87% [95% confidence interval (CI) 85% to 89%] for 2D only, 89% (95% CI 87% to 91%) for 2D + DBT and 88% (95% CI 86% to 90%) for synthetic 2D + DBT. The difference in sensitivity between 2D and 2D + DBT was of borderline significance (p = 0.07) and for synthetic 2D + DBT there was no significant difference (p = 0.6). Specificity was 58% (95% CI 56% to 60%) for 2D, 69% (95% CI 67% to 71%) for 2D + DBT and 71% (95% CI 69% to 73%) for synthetic 2D + DBT. Specificity was significantly higher in both DBT reading arms for all subgroups of age, density and dominant radiological feature (p < 0.001 all cases). In all reading arms, specificity tended to be lower for microcalcifications and higher for distortion/asymmetry. Comparing 2D + DBT to 2D alone, sensitivity was significantly higher: 93% versus 86% (p < 0.001) for invasive tumours of size 11-20 mm. Similarly, for breast density 50% or more, sensitivities were 93% versus 86% (p = 0.03); for grade 2 invasive tumours, sensitivities were 91% versus 87% (p = 0.01); where the dominant radiological feature was a mass, sensitivities were 92% and 89% (p = 0.04) For synthetic 2D + DBT, there was significantly (p = 0.006) higher sensitivity than 2D alone in invasive cancers of size 11-20 mm, with a sensitivity of 91%. CONCLUSIONS: The specificity of DBT and 2D was better than 2D alone but there was only marginal improvement in sensitivity. The performance of synthetic 2D appeared to be comparable to standard 2D. If these results were observed with screening cases, DBT and 2D mammography could benefit to the screening programme by reducing the number of women recalled unnecessarily, especially if a synthetic 2D mammogram were used to minimise radiation exposure. Further research is required into the feasibility of implementing DBT in a screening setting, prognostic modelling on outcomes and mortality, and comparison of 2D and synthetic 2D for different lesion types. STUDY REGISTRATION: Current Controlled Trials ISRCTN73467396. FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 4. See the HTA programme website for further project information.


Subject(s)
Breast Neoplasms/diagnosis , Early Detection of Cancer/methods , Imaging, Three-Dimensional/instrumentation , Mammography/methods , Adult , Aged , Breast Neoplasms/pathology , Female , Humans , Middle Aged , Retrospective Studies , Risk Factors , Sensitivity and Specificity
5.
Radiology ; 276(2): 618-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26783576
SELECTION OF CITATIONS
SEARCH DETAIL