Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 24
1.
Neuropsychopharmacol Hung ; 26(1): 30-38, 2024 03.
Article Hu | MEDLINE | ID: mdl-38603551

BACKGROUND/OBJECTIVES: David P. Bernstein's model of personal strengths was born out of the interaction of schema theory and positive psychology. According to Bernstein, the strengths of a healthy adult self can be described along four dimensions: self-directedness, self-regulation, connectedness, and transcendence. Previous research has shown that attention- deficit/hyperactivity disorder (ADHD) in adults is associated with higher levels of perceived stress, but the role of personal strengths in this context has not yet been investigated. The aim of our study was to explore the role of Bernstein's strength dimensions in the relationship between adult ADHD symptoms and perceived stress, using a dimensional approach in a non-clinical sample. METHOD: Our online questionnaire, which included the Bernstein Strengths Scale (BSS), the Adult ADHD Self-Report Scale (ASRS), and a shortened version of the Perceived Stress Scale (PSS4), was completed by 100 adults (mean age 38.25 years, standard deviation 5.73 years) after informed consent. RESULTS: In the bivariate analysis, the ASRS showed a significant negative association with the BSS dimensions, with a large effect size for self-regulation and a medium effect size for the other dimensions. On the other hand, the PSS4 scale showed significant negative correlations with all four strength dimensions, with effect sizes large for self-direction and self-regulation and medium for the connection and transcendence dimensions. Personal strengths mediated the relationship between ADHD symptoms and perceived stress. DISCUSSION: Our results suggest that ADHD symptoms may be associated with a deficit in personal strengths, which may contribute to negative outcomes. Psychotherapeutic interventions that support the recognition, cultivation and mobilization of strengths may be useful in the treatment of adults diagnosed with ADHD.


Attention Deficit Disorder with Hyperactivity , Psychological Tests , Adult , Humans , Self Report , Surveys and Questionnaires , Stress, Psychological
2.
Carbohydr Polym ; 335: 122065, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38616089

This study aimed to optimize the synthesis of trimethyl chitosan (TMC) with a high degree of N,N,N-trimethylation (DTM) through a one-step procedure, minimizing reagent use, reaction time, and avoiding O-methylation, using the Design of Experiments (DoE) approach. Initially, sequential designs were done. Following the determination of the initial conditions a Fractional Factorial Design was used, investigating methyl iodide (MeI) and NaHCO3 molar ratios, temperature, and reaction time on DTM. MeI and NaHCO3 molar ratios were found to be significant (p-values equal to 0.02 and 0.02, respectively), the reaction temperature (p = 0.04) displayed a non-linear effect, while the reaction time was found to be non-significant (p = 0.93). Finally, a Full Factorial Design was done to optimize temperature and base addition methods. Incremental addition of the base was determined to be feasible without affecting the DTM, thereby preventing any viscosity-related problems. DTM was achieved up to 72 % in a one-step procedure, with no O-methylation. These optimized conditions offer a cost-effective, one-step synthesis method for TMC production, holding significant promise for industrial applications by avoiding multistep reactions, ensuring minimal reagent use, and preventing O-methylation. The findings mark a substantial advancement in TMC synthesis, presenting a streamlined and efficient approach with substantial practical implications for process development.

3.
Circ Arrhythm Electrophysiol ; 17(2): e012402, 2024 02.
Article En | MEDLINE | ID: mdl-38284286

BACKGROUND: High-power short-duration ablation has shown impressive efficacy and safety for pulmonary vein isolation (PVI); however, initial efficacy results with very high power short-duration ablation were discouraging. This study compared the long-term durability of PVI performed with a 90- versus 50-W power setting. METHODS: Patients were randomized 1:1 to undergo PVI with the QDOT catheter using a power setting of 90 or 50 W. Three months after the index procedure, patients underwent a repeat electrophysiology study to identify pulmonary vein reconnections. Patients were followed for 12 months to detect AF recurrences. RESULTS: We included 46 patients (mean age, 64 years; women, 48%). Procedure (76 versus 84 minutes; P =0.02), left atrial dwell (63 versus 71 minutes; P =0.01), and radiofrequency (303 versus 1040 seconds; P <0.0001) times were shorter with 90- versus 50-W procedures, while the number of radiofrequency applications was higher with 90 versus 50 W (77 versus 67; P =0.01). There was no difference in first-pass isolation (83% versus 82%; P =1.0) or acute reconnection (4% versus 14%; P =0.3) rates between 90 and 50 W. Forty patients underwent a repeat electrophysiology study. Durable PVI on a per PV basis was present in 72/78 (92%) versus 68/77 (88%) PVs in the 90- and 50-W energy setting groups, respectively; effect size: 72/78-68/77=0.040, lower 95% CI=-0.051 (noninferiority limit=-0.1, ie, noninferiority is met). No complications occurred. There was no difference in 12-month atrial fibrillation-free survival between the 90- and 50-W groups (P =0.2). CONCLUSIONS: Similarly high rates of durable PVI and arrhythmia-free survival were achieved with 90 and 50 W. Procedure, left atrial dwell, and radiofrequency times were shorter with 90 W compared with 50 W. The sample size is too small to conclude the safety and long-term efficacy of the high and very high-power short-duration PVI; further studies are needed to address this topic. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05459831.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Humans , Middle Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria/surgery , Pulmonary Veins/surgery , Recurrence , Treatment Outcome , Male , Aged
4.
Life (Basel) ; 14(1)2024 Jan 17.
Article En | MEDLINE | ID: mdl-38255747

BACKGROUND: Safety, efficacy, and patient comfort are the expectations during pulmonary vein isolation (PVI). We aimed to validate the combined advantages of pre- and periprocedural anticoagulation with non-vitamin K anticoagulants (NOACs) and rigorous left atrial appendage thrombus (LAAT) exclusion with computed tomography (CT). METHODS: This study included a population of consecutive patients, between March 2018 and June 2020, who underwent cardiac CT within 24 h before PVI to guide the ablation and rule out LAAT. NOAC was omitted 24 h before the ablation. RESULTS: A total of 187 patients (63% male) underwent CT before PVI. None of the patients experienced stroke during or after the procedure. The complication rate was low, with no thromboembolic events and 2.1% of patients experiencing a major bleeding event. CONCLUSIONS: Omitting NOAC 24 h before the ablation might be safe if combined with left atrial thrombus exclusion with computed tomography.

5.
Front Cardiovasc Med ; 10: 1185187, 2023.
Article En | MEDLINE | ID: mdl-37560116

Purpose: Our purpose was to compare the procedural characteristics, success rate, and complication rate of the conventional fluoroscopic (CF) and the zero-fluoroscopic (ZF) approach in patients undergoing catheter ablation of AVNRT or typical atrial flutter (Aflu). Methods: 186 consecutive patients with an indication for AVNRT or Aflu ablation were enrolled. Based on the operator's preference, the patients were assigned to either CF or ZF group. In the ZF group EnSite NavX, Carto3, or Rhythmia EAMS were used for catheter guidance. Results: The median age was 56 (IQR = 42-68) years, 144 patients had AVNRT, and 42 had Aflu ablation. CF approach was chosen in 123 cases, while ZF in 63 cases. ZF approach was used more often in case of AVNRT patients [56 (39%) vs. 7 (17%), p = 0.006] and in the case of female patients [43 (68%) vs. 20 (32%), p = 0.008]. Acute procedural success was obtained in all cases. There was no difference in the complication rate (1 vs. 1, p > 0.99) between the two groups. No difference was found regarding the procedure time between the CF and ZF groups [CF: 55 (46-60) min, ZF 60 (47-65) min; p = 0.487] or in the procedure time for the different EAMS [EnSite NavX: 58 (50-63) min, Carto3: 60 (44.5-66.3) min, Rhythmia: 55 (35-69) min; p = 0.887]. A similar success rate was seen at the 3-month follow-up in the two groups [41 (100%) vs. 96 (97%); p = 0.55]. Discussion: The ZF approach demonstrated non-inferiority in safety and efficacy compared with CF for the AVNRT and Aflu ablations.

6.
J Arrhythm ; 39(4): 539-545, 2023 Aug.
Article En | MEDLINE | ID: mdl-37560278

Background: The efficiency of pulmonary vein isolation (PVI) depends on the durability of RF lesions. Recent studies documented sustained continuity of ablation lines, improvements in durability, and expected clinical outcomes through altered settings in duration and power. However, the ablation strategy has not been adapted to this new approach and different biophysics of lesion formation. Purpose: The aim of this study was to demonstrate that by adjusting the ablation approach to the broader geometry of lesions by increasing the minimal spacing between adjacent RF, a further significant reduction of procedural time while maintaining sufficient long-term outcomes is achievable. Methods: The presented study was a prospective, observational multi-center trial. The periprocedural data were compared with data from a consecutively collected historical cohort. Results: In total, 196 patients were included (mean age 62 ± 11 years, male 64.3%). Procedural duration, RF time, and LA dwelling time were significantly shorter in the HPSD group compared with the standard group (73 ± 26 min vs. 98 ± 36 min, p < .001; 14 ± 7 min vs. 33 ± 12 min, p < .001; and 59 ± 21 min vs. 77 ± 32 min, p < .001, respectively). Mean AF-free survival in the first year of follow-up was 304 ± 14 days in the HPSD group versus 340 ± 10 days in the standard group (log-rank p = .403). There were no statistically significant differences in the complication rates between the groups. Conclusion: Increasing the minimal distance between individual application points simplifies AF ablation and further reduces procedure time without negative effects on efficacy and safety. Larger studies are needed to optimally utilize this approach.

7.
Coron Artery Dis ; 34(1): 18-23, 2023 01 01.
Article En | MEDLINE | ID: mdl-36484216

BACKGROUND: Cardiac computed tomography (CT) is often performed before catheter ablation of atrial fibrillation to map atrial and pulmonary anatomy. Incident coronary artery disease (CAD) may also be diagnosed during cardiac CT angiography (CTA). Our aim was to assess whether coronary CTA might be able to identify a significant proportion of patients with obstructive CAD prior to their catheter ablation procedure event, even in asymptomatic patients. METHODS: Consecutive patients undergoing pre-ablation coronary CTA for atrial fibrillation between 2013 and 2020 were retrospectively selected. Patients with previously diagnosed CAD were excluded. Obstructive CAD was defined as ≥50% luminal stenosis. We analyzed the relationship between obstructive CAD, any chest pain, and traditional risk factors. RESULTS: Overall, 2321 patients [median age 63.0 (54.4-69.2), 1052/2321 (45.3%) female] underwent coronary CTA and 488/2321 (21.0%) were diagnosed with obstructive CAD. There was no difference regarding the rate of obstructive CAD in patients with any chest pain compared to patients without any chest pain [91/404 (22.5%) vs. 397/1917 (20.7%), P = 0.416, respectively). The following parameters were associated with obstructive CAD: age > 65 years [odds ratio (OR) = 2.51; 95% confidence interval (CI), 2.02-3.13; P < 0.001), male sex (OR = 1.59; 95% CI, 1.28-1.98; P < 0.001), hypertension (OR = 1.40; 95% CI, 1.08-1.81; P = 0.012), diabetes (OR = 1.50; 95% CI, 1.13-1.99; P = 0.006), dyslipidaemia (OR = 1.33; 95% CI, 1.07-1.66; P = 0.011) and history of smoking (OR = 1.34; 95% CI, 1.07-1.68; P = 0.011). CONCLUSIONS: The high prevalence of obstructive CAD even in patients without chest pain highlights the importance of additional coronary artery diagnostics in patients undergoing left atrial CTA awaiting catheter ablation for atrial fibrillation. These patients regardless of chest pain thus may require further risk modification to decrease their potential ischemic and thromboembolic risk.


Atrial Fibrillation , Coronary Artery Disease , Humans , Female , Male , Middle Aged , Aged , Computed Tomography Angiography , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Artery Disease/surgery , Retrospective Studies , Chest Pain
8.
Physiol Int ; 109(4): 511-523, 2022 Dec 14.
Article En | MEDLINE | ID: mdl-36480168

Background: Organization of mass sport events in the COVID-19 era is utterly complicated. Containments measures, required to avoid a virus outbreak, force athletes to compete under circumstances they never experienced before, most likely having a deleterious effect on their performance. Purpose: We aimed to design a so-called athlete-friendly bubble system for the International Swimming League 2020 event, which is strict enough to avoid a COVID-19 outbreak, but still provides a supportive environment for the athletes. Methods: To avoid the feeling of imprisonment, athletes were permitted to spend a certain amount of time in the parks surrounding the hotels. Such alleviations were possible to apply with strict adherence to the hygienic and social distancing protocols and regular COVID-19 testing. Evaluation of every COVID-19 positive case was key, and if prolonged PCR positivity or false positive PCR result was identified, the unnecessary quarantine was planned to be lifted. Return to play protocol (RTP) was planned, in case of a COVID-19 infection of an athlete inside the bubble. To test, if the athlete-friendly system provided a supportive environment, we evaluated athlete performance. Results: 11,480 PCR tests were performed for 1,421 individuals. 63 COVID-19 positive cases were detected, of which 5 turned out to be clinically insignificant, either because of prolonged PCR positivity or because of a false positive result. 93.1% of the positive cases were detected in the local crew, while no athlete got infected inside the bubble, as the two infected athletes were tested positive upon arrival. RTP was provided for two athletes. 85% of the athletes showed improvement during the bubble and 8 world records were broken. Conclusion: The applied protocol proved to be effective, as no athlete got infected inside the bubble, moreover, the athlete-friendly system supported the athletes to improve their performance.


Athletic Performance , COVID-19 , Humans , Swimming , COVID-19 Testing , COVID-19/diagnosis , COVID-19/epidemiology , Athletes
9.
Eur Heart J Cardiovasc Imaging ; 23(4): 515-523, 2022 03 22.
Article En | MEDLINE | ID: mdl-33693618

AIMS: Controversial results have been published regarding the influence of pulmonary vein (PV) anatomical variations on outcomes after pulmonary vein isolation (PVI). However, no data are available on the impact of PV orientation on the long-term success rates of point-by-point PVI. We sought to determine the impact of PV anatomy and orientation on atrial fibrillation (AF)-free survival in patients undergoing PVI using the radiofrequency point-by-point technique. METHODS AND RESULTS: We retrospectively included 448 patients who underwent initial point-by-point radiofrequency ablation for AF at our department. Left atrial computed tomography angiography was performed before each procedure. PV anatomical variations, ostial parameters (area, effective diameter, and eccentricity), orientation, and their associations with 24-month AF-free survival were analysed. PV anatomical variations and ostial parameters were not predictive for AF-free survival (all P > 0.05). Univariate analysis showed that female sex (P = 0.025) was associated with higher rates of AF recurrence, ventral-caudal (P = 0.002), dorsal-cranial (P = 0.034), and dorsal-caudal (P = 0.042) orientation of the right superior PV (RSPV), on the other hand, showed an association with lower rates of AF recurrence, when compared with the reference ventral-cranial orientation. On multivariate analysis, both female sex [odds ratio (OR) 1.83, 95% CI 1.15-2.93, P = 0.011] and ventral-caudal RSPV orientation, compared with ventral-cranial orientation, proved to be independent predictors of 24-month AF recurrence (OR 0.37, 95% CI 0.19-0.71, P = 0.003). CONCLUSION: Female sex and ventral-caudal RSPV orientation have an impact on long-term arrhythmia-free survival. Assessment of PV orientation may be a useful tool in predicting AF-free survival and may contribute to a more personalized management of AF.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
10.
Carbohydr Polym ; 277: 118896, 2022 Feb 01.
Article En | MEDLINE | ID: mdl-34893298

A new synthesis method was developed and optimized by a full factorial design for conjugating hydroxycinnamic acids (HCA-s) to chitosan. Cinnamic acid and tert-butyldimethylsilyl protected HCA-s were converted to their corresponding acyl chlorides and reacted with 3,6-di-O-tert-butyldimethylsilyl-chitosan to selectively form amide linkages, resulting in water-soluble conjugates after deprotection. Nineteen conjugates were obtained with various degrees of substitution (DS) ranging from 3% to 60%. The conjugates were found to be bactericidal against Staphylococcus aureus and Escherichia coli, with their activities equal to chitosan at low DS but an increase in the DS correlated with reduced activity. DPPH (2,2-diphenyl-1-picrylhydrazyl) scavenging assay was performed to determine the EC50 values. Chitosan only exhibited low antioxidant activity, whereas the HCA-chitosan conjugates exhibited higher antioxidant activities correlating with the DS. One caffeic acid conjugate (21%) was 4000 times more active than chitosan and more active than free caffeic acid.

11.
PLoS One ; 16(9): e0257050, 2021.
Article En | MEDLINE | ID: mdl-34529678

INTRODUCTION: Our pilot study aimed to evaluate the role of local impedance drop in lesion formation during pulmonary vein isolation with a novel contact force sensing ablation catheter that records local impedance as well and to find a local impedance cut-off value that predicts successful lesion formation. MATERIALS AND METHODS: After completing point-by-point radiofrequency pulmonary vein isolation, the success of the applications was evaluated by pacing along the ablation line at 10 mA, 2 ms pulse width. Lesions were considered successful if loss of local capture was achieved. RESULTS: Out of 645 applications, 561 were successful and 84 were unsuccessful. Compared to the unsuccessful ablation points, the successful applications were shorter (p = 0.0429) and had a larger local impedance drop (p<0.0001). There was no difference between successful and unsuccessful applications in terms of mean contact force (p = 0.8571), force-time integral (p = 0.0699) and contact force range (p = 0.0519). The optimal cut-point for the local impedance drop indicating successful lesion formation was 21.80 Ohms on the anterior wall [AUC = 0.80 (0.75-0.86), p<0.0001], and 18.30 Ohms on the posterior wall [AUC = 0.77 (0.72-0.83), p<0.0001]. A local impedance drop larger than 21.80 Ohms on the anterior wall and 18.30 Ohms on the posterior wall was associated with an increased probability of effective lesion creation [OR = 11.21, 95%CI 4.22-29.81, p<0.0001; and OR = 7.91, 95%CI 3.77-16.57, p<0.0001, respectively]. CONCLUSION: The measurement of the local impedance may predict optimal lesion formation. A local impedance drop > 21.80 Ohms on the anterior wall and > 18.30 Ohms on the posterior wall significantly increases the probability of creating a successful lesion.


Catheters , Electric Impedance , Pulmonary Veins/surgery , Adult , Biomechanical Phenomena , Female , Humans , Logistic Models , Male , Middle Aged , Pilot Projects , Predictive Value of Tests
12.
Europace ; 23(1): 149-156, 2021 01 27.
Article En | MEDLINE | ID: mdl-33503658

The aim of this European Heart Rhythm Association (EHRA) survey was to assess the utilization of same-day discharge (SDD) in electrophysiology (EP). An online-based questionnaire was shared with the EHRA community between 12 and 30 June 2020 and recorded institutional information, complication assessment, recent experiences, and opinions regarding possible advantages or concerns with SDD. In total, 218 responses from 49 countries provided information on current SDD management. Overall, SDD was implemented in 77.5%, whereas this proportion was significantly higher in tertiary and high-volume centres (83.8% and 85.3%, both P < 0.01). The concept of SDD was most commonly used following implantations of cardiac event recorders (97%), diagnostic EP procedures (72.2%), and implantations of pacemakers with one or two intracardiac leads (50%), while the lowest SDD utilization was observed after catheter ablations of left atrial or ventricular arrhythmias. Within SDD-experienced centres, ∼90% respondents stated that this discharge concept is recommendable or highly recommendable and reported that rates of increased rehospitalization and complication rates were low. Most respondents assumed a better utilization of hospital resources (78.2%), better cost effectiveness (77.3%), and an improved patients' comfort but were concerned about possible impairment of detection (72.5%) and management (78.7%) of late complications. In conclusion, >75% of respondents already implement SDD following EP interventions with a large heterogeneity with regard to specific procedures. Further research is needed to confirm or disprove existing and expected benefits and obstacles.


Catheter Ablation , Patient Discharge , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Europe , Humans , Perception , Surveys and Questionnaires
13.
Eur Heart J Digit Health ; 1(1): 10-19, 2020 Nov.
Article En | MEDLINE | ID: mdl-36713964

Social media increasingly impact both the private and professional lives of the majority of the population, including individuals engaged in cardiovascular healthcare and research. Healthcare providers across the world use social media platforms such as Twitter or Facebook to find medical and scientific information, to follow scientific meetings, to discuss individual clinical cases with colleagues, and to engage with patients. While social media provide a means for fast, interactive and accessible communication without geographic boundaries, their use to obtain and disseminate information has limitations and the potential threats are not always clearly understood. Governance concerns include a lack of rigorous quality control, bias due to the pre-selection of presented content by filter algorithms, and the risk of inadvertent breach of patient confidentiality. This article provides information and guidance regarding the role and use of social media platforms in cardiovascular medicine, with an emphasis on the new opportunities for the dissemination of scientific information and continuing education that arise from their responsible use.

14.
Europace ; 21(5): 732-737, 2019 May 01.
Article En | MEDLINE | ID: mdl-30689857

AIMS: Atrial fibrillation (AF) ablation has made huge progress with respect to innovation, efficacy, and safety, however, complications are still present. Recent studies examined various predictors of complications. However, limited data exist regarding the role of a repeat procedure. Our aim was the prospective evaluation of the incidence and predictors of complications related to AF ablation procedures in consecutive patients, including repeat procedures. METHODS AND RESULTS: All ablation procedures for AF between January 2013 and December 2015 were analysed in our electrophysiology laboratory. During the study period 1243 procedures were analysed [394 female, median age 62 (55-69)]. Overall complication rate was 6.84%, major complication rate was 2.82%. Major complications were the following: 18 pericardial tamponades; 5 pseudoaneurysms; 1 arteriovenous fistula; 6 thromboembolic cerebrovascular events; 3 pulmonary vein stenosis; and 2 atrioventricular blocks. No atrio-oesophageal fistula or procedure related death occurred. Univariate analysis for overall complications showed that age ≥ 65 years (P = 0.0231), female gender (P = 0.0438), hypertension (P = 0.0488), CHA2DS2-VASc score ≥ 2 (P = 0.0156), and previous AF ablation procedure (P < 0.0001) is associated with higher risk for adverse events. Multivariate analysis showed that the only independent predictor of overall complications was previous AF ablation procedure (P < 0.0001). Similarly, the only predictor of major complications was previous AF ablation procedure (P < 0.0001). CONCLUSION: Incidence of complications associated with AF ablation in our high volume electrophysiology laboratory is similar to other cohorts. The only independent predictor of complications was previous AF ablation procedure in our series.


Aneurysm, False , Atrial Fibrillation , Cardiac Tamponade , Catheter Ablation/adverse effects , Intracranial Embolism , Intraoperative Complications , Retreatment , Aged , Aneurysm, False/epidemiology , Aneurysm, False/etiology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Catheter Ablation/methods , Female , Humans , Intracranial Embolism/epidemiology , Intracranial Embolism/etiology , Intraoperative Complications/diagnosis , Intraoperative Complications/epidemiology , Male , Outcome Assessment, Health Care , Prognosis , Retreatment/adverse effects , Retreatment/methods , Retreatment/statistics & numerical data , Risk Assessment , Risk Factors
15.
JACC Clin Electrophysiol ; 4(11): 1410-1420, 2018 11.
Article En | MEDLINE | ID: mdl-30466845

OBJECTIVES: The authors aimed to evaluate the association of left ventricular (LV) lead location and long-term outcomes in MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy). BACKGROUND: There is limited data on the association of lead location with long-term clinical outcomes in patients with cardiac resynchronization therapy with defibrillator (CRT-D). METHODS: The LV lead location was classified in 797 patients with CRT-D, in 569 patients with left bundle branch block (LBBB), in 228 patients with non-LBBB, and in 505 patients with an implantable cardioverter-defibrillator (ICD) only. Leads were classified into apical (n = 83) and non-apical (n = 486); with the non-apical LV leads further categorized into anterior (n = 99) and posterior/lateral (n = 387) within LBBB. All-cause mortality and heart failure (HF) events were assessed using Kaplan-Meier and Cox analyses. RESULTS: In CRT-D patients with LBBB and posterior/lateral LV lead location, there was an association with a significant reduction in long-term all-cause mortality (hazard ratio [HR]: 0.54, 95% confidence interval [CI]: 0.37 to 0.79; p = 0.001), and HF events (HR: 0.44, 95% CI: 0.33 to 0.60; p < 0.001) compared to an ICD only, accompanied with better LV reverse remodeling. CRT-D patients with LBBB and an anterior LV lead location were shown to be associated with a significant reduction in HF events compared to an ICD only (anterior HR: 0.50, 95% CI: 0.30 to 0.82; p = 0.006); however, no association with mortality reduction was observed from CRT-D versus an ICD only. CRT-D was not associated with improved outcomes in non-LBBB patients, regardless of LV lead location. CONCLUSIONS: In mild HF patients with LBBB and an implanted CRT-D, lateral/posterior, and anterior LV lead locations are similarly associated with reduction in the risk of HF or death events compared to ICD alone. Mortality benefit derived from CRT-D is associated only with patients with lateral/posterior LV lead location. An apical LV lead location should be avoided due to the early risk of death whenever possible. (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy [MADIT-CRT], NCT00180271; Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy Post Approval Registry [MADIT-CRT-PAR], NCT01294449; and MADIT-CRT Long-Term International Follow-Up Registry - Europe, NCT02060110).


Cardiac Resynchronization Therapy , Defibrillators, Implantable , Aged , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/mortality , Cardiac Resynchronization Therapy/statistics & numerical data , Defibrillators, Implantable/adverse effects , Defibrillators, Implantable/statistics & numerical data , Female , Heart Failure/epidemiology , Heart Failure/etiology , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Treatment Outcome , Ventricular Remodeling
16.
ESC Heart Fail ; 4(4): 520-526, 2017 11.
Article En | MEDLINE | ID: mdl-28960867

AIMS: There are limited data on whether clinical presentation at first heart failure (HF) hospitalization predicts recurrent HF events. We aimed to assess predictors of recurrent HF hospitalizations in mild HF patients with an implantable cardioverter defibrillator or cardiac resynchronization therapy with defibrillator. METHODS AND RESULTS: Data on HF hospitalizations were prospectively collected for patients enrolled in MADIT-CRT. Predictors of recurrent HF hospitalization (HF2) after the first HF hospitalization were assessed using Cox proportional hazards regression models including baseline covariates and clinical presentation or management at first HF hospitalization. There were 193 patients with first HF hospitalization, and 156 patients with recurrent HF events. Recurrent HF rate after the first HF hospitalization was 43% at 1 year, 52% at 2 years, and 55% at 2.5 years. Clinical signs and symptoms, medical treatment, or clinical management of HF at first HF admission was not predictive for HF2. Baseline covariates predicting recurrent HF hospitalization included prior HF hospitalization (HR = 1.59, 95% CI: 1.15-2.20, P = 0.005), digitalis therapy (HR = 1.58, 95% CI: 1.13-2.20, P = 0.008), and left ventricular end-diastolic volume >240 mL (HR = 1.62, 95% CI: 1.17-2.25, P = 0.004). CONCLUSIONS: Recurrent HF events are frequent following the first HF hospitalization in patients with implanted implantable cardioverter defibrillator or cardiac resynchronization therapy with defibrillator. Neither clinical presentation nor clinical management during first HF admission was predictive of recurrent HF. Prior HF hospitalization, digitalis therapy, and left ventricular end-diastolic volume at enrolment predicted recurrent HF hospitalization, and these covariates could be used as surrogate markers for identifying a high-risk cohort.


Cardiac Resynchronization Therapy , Heart Failure/therapy , Hospitalization/trends , Risk Assessment , Aged , Female , Heart Failure/mortality , Humans , Male , Patient Readmission/trends , Prognosis , Prospective Studies , Recurrence , Risk Factors , Survival Rate/trends , United States/epidemiology
17.
Europace ; 18(4): 550-9, 2016 Apr.
Article En | MEDLINE | ID: mdl-26116830

AIMS: Data on longer right to left ventricular activation delay (RV-LV AD) predicting clinical outcome after cardiac resynchronization therapy (CRT) by left bundle branch block (LBBB) are limited. We aimed to evaluate the impact of RV-LV AD on N-terminal pro-B-type natriuretic peptide (NT-proBNP), ejection fraction (EF), and clinical outcome in patients implanted with CRT, stratified by LBBB at baseline. METHODS AND RESULTS: Heart failure (HF) patients undergoing CRT implantation with EF ≤ 35% and QRS ≥ 120 ms were evaluated based on their RV-LV AD at implantation. Baseline and 6-month clinical parameters, EF, and NT-proBNP values were assessed. The primary endpoint was HF or death, the secondary endpoint was all-cause mortality. A total of 125 patients with CRT were studied, 62% had LBBB. During the median follow-up of 2.2 years, 44 (35%) patients had HF/death, 36 (29%) patients died. Patients with RV-LV AD ≥ 86 ms (lower quartile) had significantly lower risk of HF/death [hazard ratio (HR): 0.44; 95% confidence interval (95% CI): 0.23-0.82; P = 0.001] and all-cause mortality (HR: 0.48; 95% CI: 0.23-1.00; P = 0.05), compared with those with RV-LV AD < 86 ms. Patients with RV-LV AD ≥ 86 ms and LBBB showed the greatest improvement in EF (28-36%; P<0.001), NT-proBNP (2771-1216 ng/mL; P < 0.001), and they had better HF-free survival (HR: 0.23, 95% CI: 0.11-0.49, P < 0.001) and overall survival (HR: 0.35, 95% CI: 0.16-0.75; P = 0.007). There was no difference in outcome by RV-LV AD in non-LBBB patients. CONCLUSION: Left bundle branch block patients with longer RV-LV activation delay at CRT implantation had greater improvement in NT-proBNP, EF, and significantly better clinical outcome.


Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/methods , Heart Conduction System/physiopathology , Heart Failure/therapy , Heart Ventricles/physiopathology , Ventricular Function, Left , Ventricular Function, Right , Action Potentials , Aged , Biomarkers/blood , Bundle-Branch Block/diagnosis , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/mortality , Chronic Disease , Disease-Free Survival , Echocardiography , Electrocardiography , Female , Heart Failure/diagnosis , Heart Failure/mortality , Heart Failure/physiopathology , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Predictive Value of Tests , Prospective Studies , Recovery of Function , Risk Factors , Stroke Volume , Time Factors , Treatment Outcome
18.
PLoS One ; 10(12): e0143907, 2015.
Article En | MEDLINE | ID: mdl-26700308

BACKGROUND: Right ventricular (RV) dysfunction has been associated with poor prognosis in chronic heart failure (HF). However, less data is available about the role of RV dysfunction in patients with cardiac resynchronization therapy (CRT). We aimed to investigate if RV dysfunction would predict outcome in CRT. DESIGN: We enrolled prospectively ninety-three consecutive HF patients in this single center observational study. All patients underwent clinical evaluation and echocardiography before CRT and 6 months after implantation. We assessed RV geometry and function by using speckle tracking imaging and calculated strain parameters. We performed multivariable Cox regression models to test mortality at 6 months and at 24 months. RESULTS: RV dysfunction, characterized by decreased RVGLS (RV global longitudinal strain) [10.2 (7.0-12.8) vs. 19.5 (15.0-23.9) %, p<0.0001] and RVFWS (RV free wall strain) [15.6 (10.0-19.3) vs. 17.4 (10.5-22.2) %, p = 0.04], improved 6 months after CRT implantation. Increasing baseline RVGLS and RVFWS predicted survival independent of other parameters at 6 months [hazard ratio (HR) = 0.37 (0.15-0.90), p = 0.02 and HR = 0.42 (0.19-0.89), p = 0.02; per 1 standard deviation increase, respectively]. RVGLS proved to be a significant independent predictor of mortality at 24 months [HR = 0.53 (0.32-0.86), p = 0.01], and RVFWS showed a strong tendency [HR = 0.64 (0.40-1.00), p = 0.05]. The 24-month survival was significantly impaired in patients with RVGLS below 10.04% before CRT implantation [area under the curve = 0.72 (0.60-0.84), p = 0.002, log-rank p = 0.0008; HR = 5.23 (1.76-15.48), p = 0.003]. CONCLUSIONS: Our findings indicate that baseline RV dysfunction is associated with poor short-term and long-term prognosis after CRT implantation.


Cardiac Resynchronization Therapy/mortality , Ventricular Dysfunction, Right/mortality , Aged , Echocardiography , Female , Humans , Male , Middle Aged , Multivariate Analysis , Prognosis , Prospective Studies , Treatment Outcome , Ventricular Dysfunction, Right/diagnostic imaging
19.
Eur J Heart Fail ; 16(12): 1323-30, 2014 Dec.
Article En | MEDLINE | ID: mdl-25379962

AIMS: There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P). METHODS AND RESULTS: We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-volume single-centre experience. Data on all-cause mortality were derived from clinic visits and the Hungarian National Healthcare Fund Death Registry. Kaplan-Meier survival analyses and multivariate Cox regression models were used to evaluate all-cause mortality in patients with CRT-D vs. CRT-P, stratified by the aetiology of cardiomyopathy. From 2000 to 2011, 1122 CRT devices, 693 CRT-P (LVEF 28.2 ± 7.4%) and 429 CRT-D (LVEF 27.6 ± 6.4%), were implanted at our centre. During the median follow-up of 28 months, 379 patients died from any cause, 250 patients (36%) with an implanted CRT-P and 129 patients (30%) with an implanted CRT-D. There was no evidence of mortality benefit in patients implanted with a CRT-D compared with a CRT-P in the total cohort [hazard ratio (HR) 0.98, 95% confidence interval (CI) 0.73-1.32, P = 0.884]. In patients with ischaemic cardiomyopathy, CRT-D treatment was associated with a significant 30% risk reduction in all-cause mortality compared with an implanted CRT-P (HR 0.70, 95% CI 0.51-0.97, P = 0.03). In non-ischaemic patients, there was no mortality benefit of CRT-D over CRT-P (HR 0.98, 95% CI 0.73-1.32, P = 0.894, interaction P-value = 0.15). CONCLUSIONS: In heart failure patients with ischaemic cardiomyopathy, CRT-D was associated with a mortality benefit compared with CRT-P, but no benefit of CRT-D over CRT-P in mortality was observed in non-ischaemic cardiomyopathy.


Cardiac Resynchronization Therapy/methods , Defibrillators, Implantable , Heart Failure/therapy , Pacemaker, Artificial , Cardiomyopathy, Dilated/diagnostic imaging , Cardiomyopathy, Dilated/mortality , Cardiomyopathy, Dilated/therapy , Cause of Death , Female , Heart Failure/diagnostic imaging , Heart Failure/mortality , Humans , Male , Ultrasonography , Ventricular Function, Left/physiology
20.
RNA ; 19(9): 1266-78, 2013 Sep.
Article En | MEDLINE | ID: mdl-23882113

Group II introns are self-splicing, retrotransposable ribozymes that contribute to gene expression and evolution in most organisms. The ongoing identification of new group II introns and recent bioinformatic analyses have suggested that there are novel lineages, which include the group IIE and IIF introns. Because the function and biochemical activity of group IIE and IIF introns have never been experimentally tested and because these introns appear to have features that distinguish them from other introns, we set out to determine if they were indeed self-splicing, catalytically active RNA molecules. To this end, we transcribed and studied a set of diverse group IIE and IIF introns, quantitatively characterizing their in vitro self-splicing reactivity, ionic requirements, and reaction products. In addition, we used mutational analysis to determine the relative role of the EBS-IBS 1 and 2 recognition elements during splicing by these introns. We show that group IIE and IIF introns are indeed distinct active intron families, with different reactivities and structures. We show that the group IIE introns self-splice exclusively through the hydrolytic pathway, while group IIF introns can also catalyze transesterifications. Intriguingly, we observe one group IIF intron that forms circular intron. Finally, despite an apparent EBS2-IBS2 duplex in the sequences of these introns, we find that this interaction plays no role during self-splicing in vitro. It is now clear that the group IIE and IIF introns are functional ribozymes, with distinctive properties that may be useful for biotechnological applications, and which may contribute to the biology of host organisms.


Introns , RNA, Catalytic/metabolism , Base Sequence , Catalysis , Chlorobium/genetics , Chlorobium/metabolism , Hydrolysis , Models, Genetic , Molecular Sequence Data , Nucleic Acid Conformation , Photorhabdus/genetics , Photorhabdus/metabolism , RNA Splicing , RNA, Catalytic/chemistry , RNA, Catalytic/genetics , RNA, Untranslated/chemistry , RNA, Untranslated/genetics , RNA, Untranslated/metabolism
...