Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Nucl Med ; 63(2): 253-258, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34088773

ABSTRACT

The radiation dose to the kidneys should be monitored in prostate cancer patients treated with radioligand therapy (RLT) targeting the prostate-specific membrane antigen (PSMA). We analyzed whether pretherapeutic kidney function is predictive of subsequent kidney dose and to what extent the cumulative kidney dose at the end of multiple therapy cycles can be predicted from a dosimetry based on the first cycle. Methods: Data of 59 patients treated with at least 2 cycles of 177Lu-PSMA-617 (PSMA RLT) were analyzed. Treatment (median, 6 GBq/cycle) was performed at 6- to 8-wk intervals, accompanied by voxel-based 3-dimensional dosimetry (measured kidney dose) with SPECT/CT on each of days 0-3 and once during days 6-9. Pretherapeutic kidney function (estimated glomerular filtration rate, mercaptoacetyltriglycine clearance) was correlated to the kidney doses. Cumulative kidney doses at the end of treatment were compared with a dose estimated from the population-based mean kidney dose, individual first-cycle kidney dose, and mean kidney doses of cycles 1, 3, and 5 per administered activity. Results: In total, 176 PSMA RLT cycles were performed, with a median of 3 cycles per patient. The average kidney dose per administered activity of all 176 cycles was 0.67 ± 0.24 Gy/GBq (range, 0.21-1.60 Gy/GBq). Mercaptoacetyltriglycine clearance and estimated glomerular filtration rate were no reliable predictors of subsequent absorbed kidney dose and showed only small effect sizes (R 2 = 0.080 and 0.014 [P = 0.039 and 0.375], respectively). All simplified estimations of cumulative kidney dose correlated significantly (P < 0.001) with measured kidney doses: estimations based on the individual first-cycle dose were more accurate than the use of the population-based average kidney dose (R 2 = 0.853 vs. 0.560). Dose estimation was best when the doses of cycles 3 and 5 were included as well (R 2 = 0.960). Conclusion: Pretherapeutic renal function was not predictive of subsequent kidney dose during therapy. Extrapolation of individual data from dosimetry of the first cycle was highly predictive of the cumulative kidney dose at the end of treatment. This prediction was further improved by the integration of dose information from every other cycle. In any case, because of a high interindividual variance, an individual dosimetry is advisable.


Subject(s)
Lutetium , Prostatic Neoplasms, Castration-Resistant , Humans , Kidney , Male , Prostate-Specific Antigen , Prostatic Neoplasms, Castration-Resistant/drug therapy , Radiometry , Single Photon Emission Computed Tomography Computed Tomography
2.
Phys Med Biol ; 60(24): 9227-51, 2015 Dec 21.
Article in English | MEDLINE | ID: mdl-26576926

ABSTRACT

PET/CT plays an important role in radiotherapy planning for lung tumors. Several segmentation algorithms have been proposed for PET tumor segmentation. However, most of them do not take into account respiratory motion and are not well validated. The aim of this work was to evaluate a semi-automated contrast-oriented algorithm (COA) for PET tumor segmentation adapted to retrospectively gated (4D) images. The evaluation involved a wide set of 4D-PET/CT acquisitions of dynamic experimental phantoms and lung cancer patients. In addition, segmentation accuracy of 4D-COA was compared with four other state-of-the-art algorithms. In phantom evaluation, the physical properties of the objects defined the gold standard. In clinical evaluation, the ground truth was estimated by the STAPLE (Simultaneous Truth and Performance Level Estimation) consensus of three manual PET contours by experts. Algorithm evaluation with phantoms resulted in: (i) no statistically significant diameter differences for different targets and movements (Δφ = 0.3 ± 1.6 mm); (ii) reproducibility for heterogeneous and irregular targets independent of user initial interaction and (iii) good segmentation agreement for irregular targets compared to manual CT delineation in terms of Dice Similarity Coefficient (DSC = 0.66 ± 0.04), Positive Predictive Value (PPV = 0.81 ± 0.06) and Sensitivity (Sen. = 0.49 ± 0.05). In clinical evaluation, the segmented volume was in reasonable agreement with the consensus volume (difference in volume (%Vol) = 40 ± 30, DSC = 0.71 ± 0.07 and PPV = 0.90 ± 0.13). High accuracy in target tracking position (ΔME) was obtained for experimental and clinical data (ΔME(exp) = 0 ± 3 mm; ΔME(clin) 0.3 ± 1.4 mm). In the comparison with other lung segmentation methods, 4D-COA has shown the highest volume accuracy in both experimental and clinical data. In conclusion, the accuracy in volume delineation, position tracking and its robustness on highly irregular target movements, make this algorithm a useful tool for 4D-PET based volume definition for radiotherapy planning of lung cancer and may help to improve the reproducibility in PET quantification for therapy response assessment and prognosis.


Subject(s)
Algorithms , Carcinoma, Non-Small-Cell Lung/secondary , Contrast Media , Image Processing, Computer-Assisted/methods , Lung Neoplasms/pathology , Phantoms, Imaging , Positron-Emission Tomography/methods , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/surgery , Feasibility Studies , Four-Dimensional Computed Tomography/methods , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/surgery , Motion , Multimodal Imaging , Radiosurgery , Reproducibility of Results , Retrospective Studies
3.
Radiother Oncol ; 115(3): 335-41, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26116339

ABSTRACT

PURPOSE: Evaluation of the effect of co-registered 4D-(18)FDG-PET/CT for SBRT target delineation in patients with central versus peripheral lung tumors. METHODS: Analysis of internal target volume (ITV) delineation of central and peripheral lung lesions in 21 SBRT-patients. Manual delineation was performed by 4 observers in 2 contouring phases: on respiratory gated 4DCT with diagnostic 3DPET available aside (CT-ITV) and on co-registered 4DPET/CT (PET/CT-ITV). Comparative analysis of volumes and inter-reader agreement. RESULTS: 11 cases of peripheral and 10 central lesions were evaluated. In peripheral lesions, average CT-ITV was 6.2 cm(3) and PET/CT-ITV 8.6 cm(3), resembling a mean change in hypothetical radius of 2 mm. For both CT-ITVs and PET/CT-ITVs inter reader agreement was good and unchanged (0.733 and 0.716; p=0.58). All PET/CT-ITVs stayed within the PTVs derived from CT-ITVs. In central lesions, average CT-ITVs were 42.1 cm(3), PET/CT-ITVs 44.2 cm(3), without significant overall volume changes. Inter-reader agreement improved significantly (0.665 and 0.750; p<0.05). 2/10 PET/CT-ITVs exceeded the PTVs derived from CT-ITVs by >1 ml in average for all observers. CONCLUSION: The addition of co-registered 4DPET data to 4DCT based target volume delineation for SBRT of centrally located lung tumors increases the inter-observer agreement and may help to avoid geographic misses.


Subject(s)
Lung Neoplasms/diagnostic imaging , Aged , Aged, 80 and over , Cone-Beam Computed Tomography , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Multimodal Imaging , Positron-Emission Tomography/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...