Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 120
Filter
1.
Am J Cardiol ; 223: 156-164, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38797196

ABSTRACT

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Postoperative Complications , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Retrospective Studies , Aortic Valve Stenosis/surgery , Aged, 80 and over , Postoperative Complications/epidemiology , Cause of Death/trends , Aged , Propensity Score , Incidence , Aortic Valve/surgery , Follow-Up Studies , Heart Failure , Treatment Outcome , Risk Factors
2.
Circ J ; 88(7): 1187-1197, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38763735

ABSTRACT

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients.Methods and Results: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Registries , Humans , Aged , Atrial Appendage/surgery , Male , Female , Aged, 80 and over , Atrial Fibrillation/surgery , Japan , Stroke/etiology , Stroke/prevention & control , Treatment Outcome , Middle Aged , Left Atrial Appendage Closure
3.
Heart Vessels ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38710808

ABSTRACT

BACKGROUND: Severe aortic valve stenosis (AS) and atrial fibrillation (AF) are risk factors of hemodynamic instability in heart failure (HF) management due to low cardiac output, respectively. Therefore, the treatment of HF due to severe AS complicated with AF is anticipated to be difficult. Tolvaptan, a vasopressin V2 receptor inhibitor, is effective in controlling acute decompensated heart failure (ADHF) with hemodynamic stability. However, its clinical efficacy against ADHF caused by AS with AF remains to be determined. METHODS: Clinical information (from September 2014 to December 2017) of 59 patients diagnosed with ADHF due to severe AS (20 patients with AF; 39 patients with sinus rhythm [SR]) was obtained from the LOHAS registry. The registry collected data from seven hospitals and assessed the short-term effects of tolvaptan in patients hospitalized for ADHF with severe AS. We attempted to identify clinical differences from baseline up to 4 days, comparing patients with AF (AF group) versus those with SR (SR group). RESULTS: There were no significant differences between the groups in age (83.7 ± 4.5 vs. 85.8 ± 6.9 years, respectively; p = 0.11) and aortic valve area (0.60 [0.46-0.73] vs. 0.56 [0.37-0.70] cm2, respectively; p = 0.50). However, left atrial volume was larger (104 [85-126] vs. 87 [64-103] mL, respectively; p < 0.01), whereas stroke volume was lower (51.6 ± 14.8 vs. 59.0 ± 18.7 mL, respectively; p = 0.08) in the AF group versus the SR group. Body weight decreased daily from baseline up to day 4 in both groups (from 55.4 to 53.2 kg [p < 0.01] and from 53.5 to 51.0 kg [p < 0.01], respectively) without change in heart rate. Notably, the systolic blood pressure decreased slightly in the AF group after 2 days of treatment with tolvaptan. CONCLUSIONS: Short-term treatment with tolvaptan improved HF in patients hospitalized for severe AS, regardless of the presence of AF or SR. After achieving sufficient diuresis, a slight decrease in blood pressure was observed in the AF group, suggesting an appropriate timeframe for safe and effective use of tolvaptan.

4.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
5.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726720

ABSTRACT

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Subject(s)
Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
6.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38660100

ABSTRACT

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

7.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38629311

ABSTRACT

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Male , Female , Aged , Mitral Valve/surgery , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , Japan , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Treatment Outcome , Time Factors , Prospective Studies , Risk Factors , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Risk Assessment , Recovery of Function , Heart Injuries/mortality , Heart Injuries/etiology , Heart Injuries/therapy , Heart Injuries/diagnostic imaging
8.
Circ J ; 88(4): 539-548, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38447968

ABSTRACT

BACKGROUND: The introduction of transcatheter edge-to-edge repair for moderate-to-severe or severe mitral regurgitation (MR) utilizing the MitraClip system became reimbursed and clinically accessible in Japan in April 2018. This study presents the 2-year clinical outcomes of all consecutively treated patients who underwent MitraClip implantation in Japan and were prospectively enrolled in the Japanese Circulation Society-oriented J-MITRA registry.Methods and Results: Analysis encompassed 2,739 consecutive patients enrolled in the J-MITRA registry with informed consent (mean age: 78.3±9.6 years, 1,550 males, STS risk score 11.7±8.9), comprising 1,999 cases of functional MR, 644 of degenerative MR and 96 in a mixed group (DMR and FMR). The acute procedure success rate was 88.9%. After MitraClip implantation, >80% exhibited an MR grade ≤2+ and the trend was sustained over the 2 years. Within this observation period, the mortality rate was 19.3% and the rate of heart failure readmissions was 20.6%. The primary composite endpoint, inclusive of cardiovascular death and heart failure readmission, was significantly higher in patients with functional MR than in with degenerative MR (32.0% vs. 17.5%, P<0.001). CONCLUSIONS: The 2-year clinical outcomes after MitraClip implantation were deduced from comprehensive data within an all-Japan registry.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Male , Humans , Aged , Aged, 80 and over , Mitral Valve/surgery , Routinely Collected Health Data , Treatment Outcome , Cardiac Catheterization/adverse effects
9.
J Clin Med ; 13(3)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38337545

ABSTRACT

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

10.
J Cardiol Cases ; 29(2): 78-81, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38362582

ABSTRACT

A 66-year-old female was diagnosed with combined post- and pre-capillary pulmonary hypertension due to heart failure with reduced ejection fraction (47 %) and functional mitral regurgitation [mean pulmonary arterial wedge pressure: 27 mmHg; pulmonary arterial pressure: 91/30 (56) mmHg; pulmonary vascular resistance: 12.9 Wood units; and cardiac index: 1.77 L/min/m2]. Following treatment with vericiguat (a novel oral soluble guanylate cyclase stimulator), hemodynamics improved [mean pulmonary arterial wedge pressure: 27 mmHg; pulmonary arterial pressure: 54/26 (35) mmHg; pulmonary vascular resistance: 2.2 Wood units; and cardiac index: 2.80 L/min/m2]. Therefore, transcatheter edge-to-edge repair for functional mitral regurgitation was performed. One month later, further improvement in hemodynamics was confirmed. Learning objective: Vericiguat (a novel oral soluble guanylate cyclase stimulator) and transcatheter edge-to-edge mitral valve repair may improve combined post- and pre-capillary pulmonary hypertension due to low ejection fraction of the left ventricle and functional mitral regurgitation.

11.
J Cardiol ; 83(5): 298-305, 2024 May.
Article in English | MEDLINE | ID: mdl-37802202

ABSTRACT

BACKGROUND: Percutaneous left atrial appendage closure (LAAC) has increased for those who need alternative to long-term anticoagulation with non-valvular atrial fibrillation (NVAF). METHODS AND RESULTS: From September 2019, after initiating WATCHMAN (Boston Scientific, Maple Grove, MN, USA) device implantation, we established Transcatheter Modification of Left Atrial Appendage by Obliteration with Device in Patients from the NVAF (TERMINATOR) registry. Utilizing 729 patients' data until January 2022, we analyzed percutaneous LAAC data regarding this real-world multicenter prospective registry. A total of 729 patients were enrolled. Average age was 74.9 years and 28.5 % were female. Paroxysmal AF was 37.9 % with average CHADS2 3.2, CHA2DS2-VASc 4.7, and HAS-BLED score of 3.4. WATCHMAN implantation was successful in 99.0 %. All-cause deaths were 3.2 %, and 1.2 % cardiovascular or unexplained deaths occurred during follow-up [median 222, interquartile range (IQR: 93-464) days]. Stroke occurred in 2.2 %, and the composite endpoint which included cardiovascular or unexplained death, stroke, and systemic embolism were counted as 3.4 % [median 221, (IQR: 93-464) days]. Major bleeding defined as BARC type 3 or 5 was seen in 3.7 %, and there was 8.6 % of all bleeding events in total [median 219, (IQR: 93-464) days]. CONCLUSIONS: These preliminary data demonstrated percutaneous LAAC with WATCHMAN device might have a potential to reduce stroke and bleeding events for patients with NVAF. Further investigation is mandatory to confirm the long-term results of this strategy using this transcatheter local therapy instead of life-long systemic anticoagulation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Female , Aged , Male , Atrial Fibrillation/complications , Atrial Fibrillation/therapy , Atrial Appendage/surgery , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Anticoagulants , Registries , Treatment Outcome
12.
JACC Asia ; 3(5): 766-773, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38094997

ABSTRACT

Background: Transcatheter edge-to-edge repair (TEER) is a less invasive treatment for patients with mitral regurgitation (MR). Limited safety and efficacy data of TEER with MitraClip, including the fourth-generation (G4) system, in a large cohort, are available. Objectives: This study aimed to summarize the initial experience of the TEER system in patients with MR from a large registry in Japan. Methods: The OCEAN (Optimized CathEter vAlvular iNtervention)-Mitral Registry is an ongoing, prospective, investigator-initiated, multicenter, observational registry for patients with primary and secondary MR undergoing transcatheter mitral valve therapies. A total of 21 centers participated in the registry. Patients undergoing TEER were enrolled, and their characteristics, procedural details, and clinical outcomes were recorded. Results: In total, 2,150 patients including 1,605 patients (75.0%) with secondary MR, were enrolled between April 2018 and June 2021. The median age was 80 years, and 43.7% were women. The median device and fluoroscopy times were 60 and 26 minutes, respectively. Those with the G4 system (618/2,150 [28.7%]) were significantly shorter than those with the second generation (G2) system (1,532/2,150 [71.3%]). Overall, 94.6% met acute procedural success without significant differences between the 2 systems (G2 94.7% vs G4 94.6%; P = 0.961). Conclusions: The OCEAN-Mitral registry has demonstrated the short-term outcomes of TEER systems, including the G4 system, in symptomatic patients with primary and secondary MR. The acute procedural success rate in the G2 system was excellent, and that in the G4 system was expected to improve with the multidisciplinary heart valve team approach. (Japanese Registry study of valvular heart diseases treatment and prognosis; UMIN000023653).

13.
J Clin Med ; 12(23)2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38068484

ABSTRACT

BACKGROUND: Individuals with heart failure displaying supra-normal left ventricular ejection fraction (snLVEF) may exhibit less favorable clinical outcomes in contrast to their counterparts with normal left ventricular ejection fraction (nLVEF). The distinctive characteristics and mid-term prognosis of individuals with severe aortic stenosis and snLVEF following transcatheter aortic valve replacement (TAVR) remain enigmatic. METHODS: Among 7393 patients diagnosed with severe aortic stenosis who underwent TAVR between 2013 and 2019 and were enlisted in the optimized transcatheter valvular intervention (OCEAN-TAVI) multicenter registry (UMIN000020423), we selected patients with left ventricular ejection fraction (LVEF) ≥ 50%. snLVEF was defined as LVEF exceeding 65%. We compared the baseline characteristics and assessed three-year post-TAVR mortality and heart failure readmission rates between the snLVEF (LVEF > 65%) and nLVEF cohorts (LVER 50-65%). RESULTS: Our study cohort comprised 5989 patients (mean age 84.4 ± 5.1 years and 1783 males). Among these, 2819 patients were categorized within the snLVEF cohort, while the remaining 3170 were allocated to the nLVEF group. Individuals within the snLVEF cohort were more likely to be female and displayed lower levels of natriuretic peptides, as well as smaller left ventricular dimensions in comparison to their nLVEF counterparts (p < 0.05 for all). The presence of snLVEF emerged as an independent predictor of the three-year composite endpoint relative to nLVEF, with an adjusted hazard ratio of 1.16 (95% confidence interval 1.02-1.31, p = 0.023) after accounting for several potential confounding factors. CONCLUSIONS: snLVEF was relatively common among candidates for TAVR with preserved ejection fraction. Patients harboring snLVEF appear to manifest a distinctive clinical profile and encounter less favorable clinical outcomes following TAVR in contrast to those characterized by nLVEF.

14.
JACC Asia ; 3(6): 925-934, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38155789

ABSTRACT

Background: There are limited data on the impact of intracardiac echocardiography (ICE)-guided transcatheter aortic valve replacement (TAVR) on the new permanent pacemaker implantation (PPMI) rate. Objectives: This study investigated the feasibility and outcome of transjugular ICE (TJ-ICE) -guided TAVR, by visualizing the relationship between the membranous septum (MS) and the transcatheter aortic valve (TAV). Methods: Among patients with severe aortic stenosis who underwent TAVR between February 2017 and June 2020, this study enrolled a total of 163 patients with TJ-ICE-guided TAVR. MS length was measured by ICE. The primary endpoint of this study was the incidence of new PPMI at 30 days. Results: The mean age of the patients in this study was 84.9 ± 4.6 years, and 71.2% of the patients were female. Device success was 96.3% with TJ-ICE guidance. A TJ-ICE-related complication occurred in 1 case (0.6%). The median length of the MS was 5.8 mm (IQR: 5.0-6.9 mm). Excellent intraobserver (intraclass correlation coefficient [ICC]: 0.94; 95% CI:0.79-0.98; P < 0.001) and interobserver (ICC: 0.93; 95% CI: -0.05 to 0.98; P < 0.001) agreements were shown. The new PPMI rate was 6.7% at 30 days without a significant difference between balloon-expandable valves and self-expandable valves (3.4% vs 8.7%; P = 0.226). Patients with a TAV implantation depth less than MS length had a significantly lower incidence of new PPMI compared with patients with a TAV implantation depth greater than MS length (2.1% vs 13.4%; P = 0.005), regardless of baseline right bundle branch block presence (6.7% vs 66.7%; P = 0.004) or absence (1.2% vs 8.2%; P = 0.041). Conclusions: TJ-ICE-guided TAVR demonstrated remarkable feasibility and safety. The TJ-ICE-guided final TAV position had a significant impact on the new PPMI rate. (Tokai Valve Registry; UMIN000036671).

16.
Contemp Clin Trials ; 134: 107358, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37852534

ABSTRACT

BACKGROUND: Despite the wide implementation of transcatheter aortic valve implantation (TAVI), the optimal antithrombotic therapy after TAVI has not been established yet. Owing to the accumulating evidence supporting the efficacy and safety of single antiplatelet therapy (SAPT) over dual antiplatelet therapy, the latest guideline recommends life-long SAPT. However, there is scarce evidence supporting SAPT compared with non-antithrombotic therapy. Given the vulnerability of patients undergoing TAVI in terms of high bleeding risk, the benefit of SAPT may be canceled out by its potential increased bleeding risk. STUDY DESIGN AND OBJECTIVES: Non-antithrombotic Therapy After Transcatheter Aortic Valve Implantation (NAPT) Trial is a prospective, randomized controlled, open-label blinded endpoint multicenter trial conducted in Japan, testing the non-inferiority of non-antithrombotic therapy compared with aspirin monotherapy in patients who underwent TAVI and had no indications for long-term oral anticoagulation therapy (OAC). Patients who successfully underwent trans-femoral TAVI for severe aortic stenosis with either balloon-expandable or self-expandable valves are eligible for inclusion. Key exclusion criteria are (i) occurrence of perioperative complications (ii) indications of taking antithrombotic drugs for other reasons; (iii) eGFR <30 ml/min/1.73 m2 or hemodialysis or peritoneal dialysis. A total of 360 patients will be randomized (1:1) to aspirin monotherapy vs. non-antithrombotic therapy. The primary outcome is a composite of all-cause mortality, myocardial infarction, stroke, and bleeding. All bleeding events based on the Valve Academic Research Consortium 3 are included as a component of the primary outcome. CONCLUSION: The NAPT trial will determine the non-inferiority of a non-antithrombotic therapy compared with aspirin monotherapy after TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Prospective Studies , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/drug therapy , Aortic Valve Stenosis/etiology , Aspirin/therapeutic use , Treatment Outcome
17.
Am J Cardiol ; 209: 1-7, 2023 12 15.
Article in English | MEDLINE | ID: mdl-37839463

ABSTRACT

The indications or timing of aortic valve replacement for symptomatic aortic stenosis (AS) are based on a patient's life expectancy and symptoms. However, clinical decision-making may be difficult because symptoms are subjective and cannot be quantitatively assessed and confirmed. This study aimed to evaluate the association between heart failure (HF)-related symptoms and cardiac hemodynamic left ventricular deformations in patients with severe AS using transthoracic echocardiographic assessments of left ventricular global longitudinal strain (LV-GLS). The medical records of patients hospitalized for AS between February 2017 and September 2019 were retrospectively screened. Independent cardiologists analyzed the transthoracic echocardiographic images of a digital echocardiography database. The cohort comprised 177 hospitalized patients with severe AS and no history of HF. The subgroup with HF-related symptoms included 87 patients, whereas that without HF-related symptoms included 90 patients. In 145 patients without atrial fibrillation, the left atrial volume index (LAVI) and LV-GLS were significantly associated with HF-related symptoms (odds ratio 1.033, 95% confidence interval 1.008 to 1.059, p = 0.011 and odds ratio 1.224, 95% confidence interval 1.118 to 1.340, p <0.0001, respectively). Moreover, the combination of brain natriuretic peptide level, LAVI, and LV-GLS showed better diagnostic accuracy than the combination of brain natriuretic peptide level and LAVI (p = 0.005). However, there were no such tendencies in 32 patients with atrial fibrillation. The HF-related symptoms in patients with severe AS were strongly linked to LV-GLS. LV-GLS showed incremental value for confirming HF-related symptoms.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Heart Failure , Ventricular Dysfunction, Left , Humans , Ventricular Function, Left , Retrospective Studies , Risk Factors , Atrial Fibrillation/complications , Global Longitudinal Strain , Natriuretic Peptide, Brain , Heart Failure/complications , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Stroke Volume
18.
J Am Heart Assoc ; 12(20): e030747, 2023 10 17.
Article in English | MEDLINE | ID: mdl-37815039

ABSTRACT

Background Limited data are available about clinical outcomes and residual mitral regurgitation (MR) after transcatheter edge-to-edge repair in the large Asian-Pacific cohort. Methods and Results From the Optimized Catheter Valvular Intervention (OCEAN-Mitral) registry, a total of 2150 patients (primary cause of 34.6%) undergoing transcatheter edge-to-edge repair were analyzed and classified into 3 groups according to the residual MR severity at discharge: MR 0+/1+, 2+, and 3+/4+. The mortality and heart failure hospitalization rates at 1 year were 12.3% and 15.0%, respectively. Both MR and symptomatic improvement were sustained at 1 year with MR ≤2+ in 94.1% of patients and New York Heart Association functional class I/II in 95.0% of patients. Compared with residual MR 0+/1+ (20.4%) at discharge, both residual MR 2+ (30.2%; P < 0.001) and 3+/4+ (32.4%; P = 0.007) were associated with the higher incidence of death or heart failure hospitalization (adjusted hazard ratio [HR], 1.59; P < 0.001, and adjusted HR, 1.73; P = 0.008). New York Heart Association class III/IV at 1 year was more common in the MR 3+/4+ group (20.0%) than in the MR 0+/1+ (4.6%; P < 0.001) and MR 2+ (6.4%; P < 0.001) groups, and the proportion of New York Heart Association class I is significantly higher in the MR 1+ group (57.8%) than in the MR 2+ group (48.3%; P = 0.02). Conclusions The OCEAN-Mitral registry demonstrated favorable clinical outcomes and sustained MR reduction at 1 year in patients undergoing transcatheter edge-to-edge repair. Both residual MR 2+ and 3+/4+ after transcatheter edge-to-edge repair at discharge were associated with worse clinical outcomes compared with residual MR 0+/1+. Registration Information https://upload.umin.ac.jp. Identifier: UMIN000023653.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Risk Factors , Treatment Outcome , Cardiac Catheterization/adverse effects , Hemodynamics , Registries
19.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Article in English | MEDLINE | ID: mdl-37668097

ABSTRACT

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Retrospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
20.
Echocardiography ; 40(11): 1187-1195, 2023 11.
Article in English | MEDLINE | ID: mdl-37715609

ABSTRACT

INTRODUCTION: This study aimed to investigate the mechanisms and clinical implications of mitral regurgitation (MR) in patients with severe aortic stenosis (AS) who received transcatheter aortic valve replacement (TAVR). METHODS: We conducted retrospective echocardiographic analyses at baseline and 6 months after TAVR in 140 patients with symptomatic AS (85 ± 5 years) who underwent TAVR. We defined significant MR as ≥ moderate based on evaluation of transthoracic echocardiography (TTE). RESULTS: There were 48 patients (34%) with preexisting MR at the baseline. Among measured TTE parameters, end-systolic wall stress (ESWS), mitral annulus area, and mitral valve thickening index were independent factors associated with preexisting MR (odds ratio [OR]: 1.013, 95% confidence interval [CI]: 1.005-1.021; OR: 1.740, 95% CI: 1.314-2.376; OR: 2.306, 95% CI: 1.426-3.848; respectively). Six months after TAVR, there were 34 patients with post-existing MR, A history of atrial fibrillation and ESWS after TAVR were independent factors (OR: 3.013, 95% CI: 1.208-7.556; OR: 1.013, 95% CI: 1.000-1.023; respectively). The Kaplan-Meier plot indicated that preexisting MR was a risk factor for heart failure-related events within 1 year of discharge after TAVR (p = .012). CONCLUSIONS: In patients who underwent TAVR for severe AS, preexisting MR was associated with having a thickened mitral valve and large mitral annulus size induced by high ESWS. These patients may have worse prognosis after TAVR and should be closely monitored in the long term.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Transcatheter Aortic Valve Replacement , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Retrospective Studies , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Treatment Outcome , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...