Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
JACC Clin Electrophysiol ; 9(12): 2628-2638, 2023 12.
Article in English | MEDLINE | ID: mdl-37715742

ABSTRACT

BACKGROUND: His-Purkinje conduction system pacing (HPCSP) using His bundle pacing (HBP) or left bundle branch pacing (LBBP) has emerged as an alternative to biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy (CRT). OBJECTIVES: The aim of the study was to compare the feasibility and clinical efficacy of HOT-CRT (His-Purkinje conduction system pacing Optimized Trial of Cardiac Resynchronization Therapy) with BVP in patients with heart failure, reduced ejection fraction, and indication for CRT. METHODS: This was a prospective, randomized, controlled trial of HOT-CRT and BVP in patients with LVEF <50% and indications for CRT. If HPCSP resulted in incomplete electrical resynchronization, a coronary sinus (CS) lead was added. The primary outcome was the change in left ventricular ejection fraction (LVEF) at 6 months. The primary safety endpoint was freedom from major complications. RESULTS: A total of 100 patients (female 31%, aged 70 ± 12 years, LVEF 31.5% ± 9.0%) were randomized. HOT-CRT was successful in 48 of 50 (96%) and BVP-CRT in 41 of 50 (82%) patients (P = 0.03). QRS duration significantly decreased from 164 ± 26 ms to 137 ± 20 ms with HOT-CRT and 166 ± 28 ms to 141 ± 19 ms with BVP. Fluoroscopy results (18.8 ± 12.4 min vs 23.8 ± 12.4 min, P = 0.05) and procedure duration (119 ± 42 min vs 114 ± 36 min, P = 0.5) were similar. The primary outcome of change in LVEF at 6 months was greater in HOT-CRT than in BVP (12.4% ± 7.3% vs 8.0% ± 10.1%, P = 0.02). The primary safety endpoint was similar (98% vs 94%, P = 0.62). Echocardiographic response of improvement in LVEF >5% occurred in 80% vs 61% (P = 0.06). Complications occurred in 3 (6%) in HOT-CRT vs 10 (20%) in BVP (P = 0.03). CONCLUSIONS: HPCSP-guided CRT resulted in greater change in LVEF compared with BVP. Randomized clinical trials with long-term follow-up are necessary. (His-Purkinje Conduction System Pacing Optimized Trial of Cardiac Resynchronization Therapy [HOT-CRT]; NCT04561778).


Subject(s)
Cardiac Resynchronization Therapy , Humans , Female , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Bundle-Branch Block , Bundle of His , Stroke Volume , Prospective Studies , Ventricular Function, Left , Electrocardiography/methods
2.
Heart Rhythm O2 ; 3(4): 368-376, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36097467

ABSTRACT

Background: Atrioventricular node ablation (AVNA) with right ventricular or biventricular pacing (conventional pacing; CP) is an effective therapy for patients with refractory atrial fibrillation (AF). Conduction system pacing (CSP) using His bundle pacing or left bundle branch area pacing preserves ventricular synchrony. Objective: The aim of our study is to compare the clinical outcomes between CP and CSP in patients undergoing AVNA. Methods: Patients undergoing AVNA at Geisinger Health System between January 2015 and October 2020 were included in this retrospective observational study. CP or CSP was performed at the operators' discretion. Procedural, pacing parameters, and echocardiographic data were assessed. Primary outcome was the combined endpoint of time to death or heart failure hospitalization (HFH) and was analyzed using Cox proportional hazards. Secondary outcomes were individual outcomes of time to death and HFH. Results: AVNA was performed in 223 patients (CSP, 110; CP, 113). Age was 75 ± 10 years, male 52%, hypertension 67%, diabetes 25%, coronary disease 40%, and left ventricular ejection fraction (LVEF) 43% ± 15%. QRS duration increased from 103 ± 30 ms to 124 ± 20 ms (P < .01) in CSP and 119 ± 32 ms to 162 ± 24 ms in CP (P < .001). During a mean follow-up of 27 ± 19 months, LVEF significantly increased from 46.5% ± 14.2% to 51.9% ± 11.2% (P = .02) in CSP and 36.4% ± 16.1% to 39.5% ± 16% (P = .04) in CP. The primary combined endpoint of time to death or HFH was significantly reduced in CSP compared to CP (48% vs 62%; hazard ratio 0.61, 95% confidence interval 0.42-0.89, P < .01). There was no reduction in the individual secondary outcomes of time to death and HFH in the CSP group compared to CP. Conclusion: CSP is a safe and effective option for pacing in patients with AF undergoing AVNA in high-volume centers.

3.
Heart Rhythm ; 19(8): 1263-1271, 2022 08.
Article in English | MEDLINE | ID: mdl-35500791

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is well-established therapy in patients with reduced left ventricular ejection fraction (LVEF) and bundle branch block or indication for pacing. Conduction system pacing (CSP) using His-bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has been shown to be a safe and more physiological alternative to BVP. OBJECTIVE: The purpose of this study was to compare the clinical outcomes between CSP and BVP among patients undergoing CRT. METHODS: This observational study included consecutive patients with LVEF ≤35% and class I or II indications for CRT who underwent successful BVP or CSP at 2 major health care systems. The primary outcome was the composite endpoint of time to death or heart failure hospitalization (HFH). Secondary outcomes included subgroup analysis in left bundle branch block as well as individual endpoints of death and HFH. RESULTS: A total of 477 patients (32% female) met inclusion criteria (BVP 219; CSP 258 [HBP 87, LBBAP 171]). Mean age was 72 ± 12 years, and mean LVEF was 26% ± 6%. Comorbidities included hypertension 70%, diabetes mellitus 45%, and coronary artery disease 52%. Paced QRS duration in CSP was significantly narrower than BVP (133 ± 21 ms vs 153 ± 24 ms; P <.001). LVEF improved in both groups during mean follow-up of 27 ± 12 months and was greater after CSP compared to BVP (39.7% ± 13% vs 33.1% ± 12%; P <.001). Primary outcome of death or HFH was significantly lower with CSP vs BVP (28.3% vs 38.4%; hazard ratio 1.52; 95% confidence interval 1.082-2.087; P = .013). CONCLUSION: CSP improved clinical outcomes compared to BVP in this large cohort of patients with indications for CRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Aged , Aged, 80 and over , Bundle of His , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/adverse effects , Electrocardiography , Female , Humans , Male , Middle Aged , Stroke Volume , Treatment Outcome , Ventricular Function, Left
5.
Heart Rhythm ; 19(1): 3-11, 2022 01.
Article in English | MEDLINE | ID: mdl-34481985

ABSTRACT

BACKGROUND: Left bundle branch area pacing (LBBAP) has been shown to be a feasible option for patients requiring ventricular pacing. OBJECTIVE: The purpose of this study was to compare clinical outcomes between LBBAP and RVP among patients undergoing pacemaker implantation METHODS: This observational registry included patients who underwent pacemaker implantations with LBBAP or RVP for bradycardia indications between April 2018 and October 2020. The primary composite outcome included all-cause mortality, heart failure hospitalization (HFH), or upgrade to biventricular pacing. Secondary outcomes included the composite endpoint among patients with a prespecified burden of ventricular pacing and individual outcomes. RESULTS: A total of 703 patients met inclusion criteria (321 LBBAP and 382 RVP). QRS duration during LBBAP was similar to baseline (121 ± 23 ms vs 117 ± 30 ms; P = .302) and was narrower compared to RVP (121 ± 23 ms vs 156 ± 27 ms; P <.001). The primary composite outcome was significantly lower with LBBAP (10.0%) compared to RVP (23.3%) (hazard ratio [HR] 0.46; 95%T confidence interval [CI] 0.306-0.695; P <.001). Among patients with ventricular pacing burden >20%, LBBAP was associated with significant reduction in the primary outcome compared to RVP (8.4% vs 26.1%; HR 0.32; 95% CI 0.187-0.540; P <.001). LBBAP was also associated with significant reduction in mortality (7.8% vs 15%; HR 0.59; P = .03) and HFH (3.7% vs 10.5%; HR 0.38; P = .004). CONCLUSION: LBBAP resulted in improved clinical outcomes compared to RVP. Higher burden of ventricular pacing (>20%) was the primary driver of these outcome differences.


Subject(s)
Bradycardia/therapy , Bundle of His/physiopathology , Cardiac Resynchronization Therapy/methods , Heart Ventricles/physiopathology , Registries , Aged , Bradycardia/physiopathology , Feasibility Studies , Female , Humans , Male , Retrospective Studies , Time Factors , Treatment Outcome
7.
Heart Rhythm ; 16(12): 1797-1807, 2019 12.
Article in English | MEDLINE | ID: mdl-31096064

ABSTRACT

BACKGROUND: The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of a left ventricular lead for cardiac resynchronization therapy (His-CRT) and biventricular pacing (BiV-CRT), but was limited by high rates of crossover. OBJECTIVE: To evaluate the results of the His-SYNC pilot trial utilizing treatment-received (TR) and per-protocol (PP) analyses. METHODS: The His-SYNC pilot was a multicenter, prospective, single-blinded, randomized, controlled trial comparing His-CRT vs BiV-CRT in patients meeting standard indications for CRT (eg, NYHA II-IV patients with QRS >120 ms). Crossovers were required based on prespecified criteria. The primary endpoints analyzed included improvement in QRS duration, left ventricular ejection fraction (LVEF), and freedom from cardiovascular (CV) hospitalization and mortality. RESULTS: Among 41 patients enrolled (aged 64 ± 13 years, 38% female, LVEF 28%, QRS 168 ± 18 ms), 21 were randomized to His-CRT and 20 to BiV-CRT. Crossover occurred in 48% of His-CRT and 26% of BiV-CRT. The most common reason for crossover from His-CRT was inability to correct QRS owing to nonspecific intraventricular conduction delay (n = 5). Patients treated with His-CRT demonstrated greater QRS narrowing compared to BiV (125 ± 22 ms vs 164 ± 25 ms [TR], P < .001;124 ± 19 ms vs 162 ± 24 ms [PP], P < .001). A trend toward higher echocardiographic response was also observed (80 vs 57% [TR], P = .14; 91% vs 54% [PP], P = .078). No significant differences in CV hospitalization or mortality were observed. CONCLUSIONS: Patients receiving His-CRT on-treatment demonstrated superior electrical resynchronization and a trend toward higher echocardiographic response than BiV-CRT. Larger prospective studies may be justifiable with refinements in patient selection and implantation techniques to minimize crossovers.


Subject(s)
Bundle of His/physiopathology , Cardiac Resynchronization Therapy , Echocardiography/methods , Electrocardiography/methods , Heart Failure , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy Devices , Female , Heart Failure/physiopathology , Heart Failure/therapy , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Severity of Illness Index , Stroke Volume , Treatment Outcome
9.
J Am Coll Cardiol ; 71(20): 2319-2330, 2018 05 22.
Article in English | MEDLINE | ID: mdl-29535066

ABSTRACT

BACKGROUND: Right ventricular pacing (RVP) is associated with heart failure and increased mortality. His bundle pacing (HBP) is a physiological alternative to RVP. OBJECTIVES: This study sought to evaluate clinical outcomes of HBP compared to RVP. METHODS: All patients requiring initial pacemaker implantation between October 1, 2013, and December 31, 2016, were included in the study. Permanent HBP was attempted in consecutive patients at 1 hospital and RVP at a sister hospital. Implant characteristics, all-cause mortality, heart failure hospitalization (HFH), and upgrades to biventricular pacing (BiVP) were tracked. Primary outcome was the combined endpoint of death, HFH, or upgrade to BiVP. Secondary endpoints were mortality and HFH. RESULTS: HBP was successful in 304 of 332 consecutive patients (92%), whereas 433 patients underwent RVP. The primary endpoint of death, HFH, or upgrade to BiVP was significantly reduced in the HBP group (83 of 332 patients [25%]) compared to RVP (137 of 433 patients [32%]; hazard ratio [HR]: 0.71; 95% confidence interval [CI]: 0.534 to 0.944; p = 0.02). This difference was observed primarily in patients with ventricular pacing >20% (25% in HBP vs. 36% in RVP; HR: 0.65; 95% CI: 0.456 to 0.927; p = 0.02). The incidence of HFH was significantly reduced in HBP (12.4% vs. 17.6%; HR: 0.63; 95% CI: 0.430 to 0.931; p = 0.02). There was a trend toward reduced mortality in HBP (17.2% vs. 21.4%, respectively; p = 0.06). CONCLUSIONS: Permanent HBP was feasible and safe in a large real-world population requiring permanent pacemakers. His bundle pacing was associated with reduction in the combined endpoint of death, HFH, or upgrade to BiVP compared to RVP in patients requiring permanent pacemakers.


Subject(s)
Bundle of His/diagnostic imaging , Cardiac Pacing, Artificial/trends , Heart Failure/diagnostic imaging , Heart Failure/therapy , Pacemaker, Artificial/trends , Aged , Aged, 80 and over , Cardiac Pacing, Artificial/methods , Cohort Studies , Female , Follow-Up Studies , Heart Failure/mortality , Heart Ventricles/diagnostic imaging , Hospitalization/trends , Humans , Male , Middle Aged , Mortality/trends , Treatment Outcome
10.
Heart Rhythm ; 15(5): 696-702, 2018 05.
Article in English | MEDLINE | ID: mdl-29274474

ABSTRACT

BACKGROUND: Right ventricular pacing (RVP) is associated with heart failure and increased mortality. His-bundle pacing (HBP) is a physiological alternative to RVP. OBJECTIVE: The purpose of this study was to report long-term performance and compare the clinical outcomes of permanent HBP vs RVP. METHODS: All patients requiring pacemaker implantation underwent an attempt at permanent HBP in 2011 at one hospital and RVP at the sister hospital. Patients were followed from implantation, 2 weeks, 2 months, and yearly for 5 years. Left ventricular ejection fraction (LVEF), pacing thresholds, lead revision, and generator change were tracked. Primary outcome was the combined endpoint of death or heart failure hospitalization (HFH) at 5 years. RESULTS: HBP was attempted in 94 consecutive patients and was successful in 75 (80%); 98 patients underwent RVP. LVEF remained unchanged in the HBP group (55% ± 8% vs 57% ± 6%; P = .13), whereas significant decline was noted in the RVP group (57% ± 7% vs 52% ± 11%; P = .002). Incidence of pacing-induced cardiomyopathy was significantly lower in HBP compared to RVP patients (2% vs 22%; P = .04). At 5 years, death or HFH was significantly lower in HBP compared to RVP patients with >40% ventricular pacing (32% vs 53%; hazard ratio 1.9; P = .04). At 5 years, the need for lead revisions (6.7% vs 3%) and for generator change (9% vs 1%) were higher in the HBP group. CONCLUSION: In patients undergoing pacemaker implantation, permanent HBP was associated with reduction in death or HFH during long-term follow-up compared to RVP. HBP was associated with higher rates of lead revisions and generator change.


Subject(s)
Bradycardia/therapy , Bundle of His/physiopathology , Cardiac Pacing, Artificial/methods , Electrocardiography , Ventricular Function, Left/physiology , Ventricular Function, Right/physiology , Aged , Bradycardia/diagnosis , Bradycardia/physiopathology , Case-Control Studies , Echocardiography , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Stroke Volume/physiology , Time Factors , Treatment Outcome
11.
Heart Rhythm ; 12(2): 305-12, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25446158

ABSTRACT

BACKGROUND: Right ventricular pacing (RVP) has been associated with heart failure and increased mortality. His-bundle pacing (HBP) is more physiological but requires a mapping catheter or a backup right ventricular lead and is technically challenging. OBJECTIVE: We sought to assess the feasibility, safety, and clinical outcomes of permanent HBP in an unselected population as compared to RVP. METHODS: All patients requiring pacemaker implantation routinely underwent attempt at permanent HBP using the Select Secure (model 3830) pacing lead in the year 2011 delivered through a fixed-shaped catheter (C315 HIS) at one hospital and RVP at the second hospital. Patients were followed from implantation, 2 weeks, 2 months, 1 year, and 2 years. Fluoroscopy time (FT), pacing threshold (PTh), complications, heart failure hospitalization, and mortality were compared. RESULTS: HBP was attempted in 94 consecutive patients, while 98 patients underwent RVP. HBP was successful in 75 patients (80%). FT was similar (12.7 ± 8 minutes vs 10 ± 14 minutes; median 9.1 vs 6.4 minutes; P = .14) and PTh was higher in the HBP group than in the RVP group (1.35 ± 0.9 V vs 0.6 ± 0.5 V at 0.5 ms; P < .001) and remained stable over a 2-year follow-up period. In patients with >40% ventricular pacing (>60% of patients), heart failure hospitalization was significantly reduced in the HBP group than in the RVP group (2% vs 15%; P = .02). There was no difference in mortality between the 2 groups (13% in the HBP group vs 18% in the RVP group; P = .45). CONCLUSION: Permanent HBP without a mapping catheter or a backup right ventricular lead was successfully achieved in 80% of patients. PTh was higher and FT was comparable to those of the RVP group. Clinical outcomes were better in the HBP group than in the RVP group.


Subject(s)
Bradycardia/prevention & control , Bundle of His/physiopathology , Cardiac Pacing, Artificial/methods , Electrocardiography , Heart Failure/therapy , Heart Ventricles/physiopathology , Adolescent , Adult , Aged , Aged, 80 and over , Bradycardia/etiology , Bradycardia/physiopathology , Feasibility Studies , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/physiopathology , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Young Adult
12.
Ann Noninvasive Electrocardiol ; 18(5): 487-90, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24047495

ABSTRACT

Congenital disorders, such as dextrocardia and persistent left superior vena cava, are rare. However, their presence is often associated with other cardiac anomalies, and may lead to lethal ventricular tachyarrhythmias, which result in sudden cardiac death. Treating patients with these disorders can present a challenge to clinicians, as it may cause technical difficulties during interventional procedures, and more often, altered defibrillation techniques in a setting of prehospital sudden cardiac arrest. This report describes the first case of successful defibrillation therapy delivered by the wearable cardioverter defibrillator to a patient with dextrocardia and persistent left superior vena cava during a ventricular tachycardia arrest.


Subject(s)
Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators , Dextrocardia/complications , Tachycardia, Ventricular , Vena Cava, Superior/abnormalities , Adult , Electrocardiography/methods , Humans , Male , Treatment Outcome
13.
Pacing Clin Electrophysiol ; 30(4): 498-501, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17437573

ABSTRACT

BACKGROUND: Cardiac tamponade is a rare complication after implantation of dual chamber pacemaker or defibrillator systems. Its pathophysiology and optimal management are not currently well established. METHODS: Three cases of cardiac tamponade following successful implantation of transvenous dual chamber pacemakers with active-fixation atrial leads were identified. RESULTS: All three patients with post-implant cardiac tamponade were suspected to have the same etiology of bleeding into the pericardial space. This was due to protrusion of the helix of the active-fixation atrial pacing lead through the atrial wall with subsequent abrasion of visceral pericardial layer and bleeding from the atrium through the perforation. In two patients, the perforation sites were visualized and repaired during open thoracotomy in the operating room. The third patient underwent lead repositioning under fluoroscopic guidance in the electrophysiology laboratory. CONCLUSION: Based on the reviewed cases, we describe the pathophysiology of, and recommend a safe conservative algorithm for, the management of cardiac tamponade after successful transvenous lead implantation. Percutaneous pericardiocentesis with placement of the pericardial drain followed by lead repositioning under fluoroscopic guidance with surgical backup appears to be safe and effective.


Subject(s)
Cardiac Tamponade/etiology , Heart Atria/injuries , Pacemaker, Artificial/adverse effects , Aged , Algorithms , Cardiac Tamponade/surgery , Female , Heart Atria/surgery , Heart Injuries/etiology , Heart Injuries/physiopathology , Heart Injuries/surgery , Humans , Middle Aged , Pericardial Effusion/etiology , Pericardial Effusion/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...