Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Aerobiologia (Bologna) ; 31(3): 389-401, 2015.
Article in English | MEDLINE | ID: mdl-26346115

ABSTRACT

Museums, archives and libraries have large working environments. The goal of this study was to determine microbial contamination in these work places and estimate the influence of microclimatic parameters and total dust content on microbial contamination. In addition, research included evaluation of ergosterol concentration and fungal bioaerosol particle size distribution. Numbers of micro-organisms in the air and on the surfaces in museums were higher (2.1 × 102-7.0 × 103 cfu/m3 and 1.4 × 102-1.7 × 104 cfu/100 cm2, respectively) than in archives and libraries (3.2 × 102-7.2 × 102 cfu/m3 and 8.4 × 102-8.8 × 102 cfu/100 cm2, respectively). The numbers of micro-organisms detected in the tested museums, archives and libraries did not exceed occupational exposure limits proposed by Polish Committee for the Highest Permissible Concentrations and Intensities of Noxious Agents at the Workplace. The concentrations of respirable and suspended dust in museum storerooms were 2-4 times higher than the WHO-recommended limits. We found a correlation between microclimatic conditions and numbers of micro-organisms in the air in the tested working environments. In addition, a correlation was also found between ergosterol concentration and the number of fungi in the air. Fungi were the dominant micro-organisms in the working environments tested. Particles within the dominant fractions of culturable fungal aerosols sampled from museum storerooms had aerodynamic diameters between 1.1 and 2.1 µm.

2.
Int J Occup Saf Ergon ; 18(3): 329-42, 2012.
Article in English | MEDLINE | ID: mdl-22995132

ABSTRACT

This article proposes a method for a comprehensive assessment of the effect of integral motorcycle helmets on physiological and cognitive responses of motorcyclists. To verify the reliability of commonly used tests, we conducted experiments with 5 motorcyclists. We recorded changes in physiological parameters (heart rate, local skin temperature, core temperature, air temperature, relative humidity in the space between the helmet and the surface of the head, and the concentration of O(2) and CO(2) under the helmet) and in psychological parameters (motorcyclists' reflexes, fatigue, perceptiveness and mood). We also studied changes in the motorcyclists' subjective sensation of thermal comfort. The results made it possible to identify reliable parameters for assessing the effect of integral helmets on performance, i.e., physiological factors (head skin temperature, internal temperature and concentration of O(2) and CO(2) under the helmet) and on psychomotor factors (reaction time, attention and vigilance, work performance, concentration and a subjective feeling of mood and fatigue).


Subject(s)
Head Protective Devices , Psychomotor Performance , Adult , Affect , Carbon Dioxide/analysis , Cognition , Fatigue/physiopathology , Head Protective Devices/adverse effects , Heart Rate , Humans , Humidity , Motorcycles , Oxygen/analysis , Reaction Time , Skin Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...