2.
Adv Emerg Nurs J ; 46(2): 149-157, 2024.
Article in English | MEDLINE | ID: mdl-38736099

ABSTRACT

Nonsustained ventricular tachycardia (NSVT) is a common arrhythmia associated with heart failure, cardiomyopathy, coronary artery disease, electrolyte imbalances, and congenital heart disorders (Foth et al., 2023). NSVT is often asymptomatic depending on its burden percentage. However, typical NSVT presentation in the emergency department (ED) includes palpitations, near-syncope, dizziness, skipped beats, chest pain, and/or dyspnea (Katritsis et al., 2012). In some instances, NSVT can present with elevated or slightly elevated troponin from demand ischemia. A definite diagnosis of NSVT is not of high complexity; nevertheless, it is not always identified on electrocardiogram (ECG) by the time the patient arrives to the ED. Identification of NSVT usually requires prolonged cardiac monitoring, mobile cardiac telemetry (MCT), and in some instances internal loop recorder placement. The purpose of this case is to discuss the typical presentation and pharmacological approach of patients with stable NSVT.


Subject(s)
Electrocardiography , Tachycardia, Ventricular , Humans , Anti-Arrhythmia Agents/therapeutic use , Emergency Service, Hospital , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/diagnosis
3.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38545321

ABSTRACT

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

4.
J Cardiovasc Electrophysiol ; 35(5): 916-928, 2024 May.
Article in English | MEDLINE | ID: mdl-38439119

ABSTRACT

INTRODUCTION: Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12-lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case-control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy. MATERIALS AND METHODS: Cases in which system output was used were retrospectively enrolled according to IRB-approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time-stamped medical records. RESULTS: The study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation (n = 10), premature ventricular complexes (n = 8), and ventricular tachycardia (n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow-up, arrhythmia-free survival was 73.5% in the study group and 63.3% in the control group (p = 0.56). CONCLUSION: Use of forward-solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.


Subject(s)
Action Potentials , Arrhythmias, Cardiac , Artificial Intelligence , Catheter Ablation , Predictive Value of Tests , Time-to-Treatment , Aged , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Electrocardiography , Electrophysiologic Techniques, Cardiac , Fluoroscopy , Heart Rate , Operative Time , Retrospective Studies , Time Factors , Treatment Outcome , Case-Control Studies
5.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38390748

ABSTRACT

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Subject(s)
Catheter Ablation , Swine , Animals , Catheter Ablation/adverse effects , Heart Ventricles/surgery , Catheters , Equipment Design
6.
J Interv Card Electrophysiol ; 67(3): 639-648, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37855992

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS: We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS: We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS: Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/surgery , Treatment Outcome , Pulmonary Veins/surgery
7.
Heart Rhythm O2 ; 4(10): 599-608, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37936671

ABSTRACT

Background: Pulsed field ablation (PFA) has emerged as a novel energy source for the ablation of atrial fibrillation (AF) using ultrarapid electrical pulses to induce cell death via electroporation. Objective: The purpose of this study was to compare the safety and acute efficacy of ablation for AF with PFA vs thermal energy sources. Methods: We performed an extensive literature search and systematic review of studies that evaluated the safety and efficacy of ablation for AF with PFA and compared them to landmark clinical trials for ablation of AF with thermal energy sources. Freeman-Tukey double arcsine transformation was used to establish variance of raw proportions followed by the inverse with the random-effects model to combine the transformed proportions and generate the pooled prevalence and 95% confidence interval (CI). Results: We included 24 studies for a total of 5203 patients who underwent AF ablation. Among these patients, 54.6% (n = 2842) underwent PFA and 45.4% (n = 2361) underwent thermal ablation. There were significantly fewer periprocedural complications in the PFA group (2.05%; 95% CI 0.94-3.46) compared to the thermal ablation group (7.75%; 95% CI 5.40-10.47) (P = .001). When comparing AF recurrence up to 1 year, there was a statistically insignificant trend toward a lower prevalence of recurrence in the PFA group (14.24%; 95% CI 6.97-23.35) compared to the thermal ablation group (25.98%; 95% CI 15.75-37.68) (P = .132). Conclusion: Based on the results of this meta-analysis, PFA was associated with lower rates of periprocedural complications and similar rates of acute procedural success and recurrent AF with up to 1 year of follow-up compared to ablation with thermal energy sources.

8.
Clin Cardiol ; 46(12): 1488-1494, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37626475

ABSTRACT

BACKGROUND: Catheter ablation improves outcomes in symptomatic atrial fibrillation (AF) patients. However, its safety and efficacy in the very elderly (≥80 years old) is not well described. HYPOTHESIS: Ablation of AF in the very elderly is safe and effective. METHODS: We performed a retrospective study of all patients who underwent catheter ablation enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AADs). RESULTS: Of 847 patients, 42 (5.0%) were 80 years of age or greater with a median age of 81.5 (80-82.3) and 805 (95.0%) were less than 80 years of age with a median age of 64.4 (57.6-70.2). Among those who were ≥80 years old, 29 were undergoing de novo ablation (69.0%), whereas in the younger cohort, 518 (64.5%) were undergoing de novo ablation (p = .548). There were no statistically significant differences in fluoroscopy (p = .406) or total procedure times (p = .076), AAD use (p = .611), or procedural complications (p = .500) between groups. After multivariable adjustment, there were no statistically significant differences in recurrence of any atrial arrhythmias on or off AAD (adjusted hazard ratio [AHR]: 0.75; 95% confidence interval [CI]: 0.45-1.23; p = .252), all-cause hospitalizations (AHR: 0.86; 95% CI: 0.46-1.60; p = .626), or all-cause mortality (AHR: 4.48; 95% CI: 0.59-34.07; p = .147) between the very elderly and the younger cohort. CONCLUSION: In this registry analysis, catheter ablation of AF appears similarly effective and safe in patients 80 years or older when compared to a younger cohort.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Aged , Aged, 80 and over , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Retrospective Studies , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
9.
Comput Biol Med ; 157: 106766, 2023 05.
Article in English | MEDLINE | ID: mdl-36958236

ABSTRACT

Cryoballoon ablation (CBA) is a cryo-energy based minimally invasive treatment procedure for patients suffering from left atrial (LA) fibrillation. Although this technique has proved to be effective, it is prone to reoccurrences and some serious thermal complications. Also, the factors affecting thermal distribution at the pulmonary vein-antrum junction that are critical to the treatment success is poorly understood. Computer modeling of CBA can resolve this issue and help understand the factors affecting this treatment. To do so, however, numerical challenges associated with the simulation of advection-dominant transport process must be resolved. Here, we describe the development of a thermal-hemodynamics computational framework to simulate incomplete occlusion in a patient-specific LA geometry during CBA. The modeling framework uses the finite element method to predict hemodynamics, thermal distribution, and lesion formation during CBA. An incremental pressure correction scheme is used to decouple velocity and pressure in the Navier-Stokes equation, whereas several stabilization techniques are also applied to overcome numerical instabilities. The framework was implemented using an open-source FE library (FEniCS). We show that model predictions of the hemodynamics in a realistic human LA geometry match well with measurements. The effects of cryoballoon position, pulmonary vein blood velocity and mitral regurgitation on lesion formation during CBA was investigated. For a -700C cryoballoon temperature, the model predicts lesion formation for gaps less than 2.5 mm and increasing efficiency of CBA for higher balloon tissue contact areas. The simulations also predict that lesion formation is not sensitive to variation in pulmonary vein blood velocity and mitral regurgitation. The framework can be applied to optimize CBA in patients for future clinical studies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Mitral Valve Insufficiency , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Atrial Fibrillation/surgery , Treatment Outcome , Hemodynamics , Computer Simulation , Catheter Ablation/methods , Recurrence
10.
Adv Emerg Nurs J ; 45(1): 51-58, 2023.
Article in English | MEDLINE | ID: mdl-36757748

ABSTRACT

Arrhythmogenic cardiomyopathy (AC) is a genetic cardiac disorder associated with sudden cardiac death, specifically in young adults (D. Corrado, C. Basso, & D. Judge, 2017). AC is a disease of the heart muscle fibers and it is not usually diagnosed until its advanced stages. Typical AC presentation in the emergency department (ED) includes cardiac syncope, palpitations, ventricular arrhythmias, or resolved cardiac arrest. The epsilon wave is the hallmark and the major electrocardiographic (ECG) diagnostic criterion for AC in the later stages of the disease process (A. R. Perez-Riera et al., 2019). A definite diagnosis of AC is of high complexity and not typically made by emergency providers; however, many cases of advanced AC are discovered in the ED as a result of syncope. The purpose of this case review is to discuss the typical presentation, ECG findings, and emergency providers' role in the management of patients with suspected AC.


Subject(s)
Arrhythmias, Cardiac , Heart Arrest , Young Adult , Humans , Arrhythmias, Cardiac/diagnosis , Electrocardiography , Syncope/diagnosis , Emergency Service, Hospital
11.
J Interv Card Electrophysiol ; 66(5): 1243-1252, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36508065

ABSTRACT

BACKGROUND: High-dose isoproterenol infusion is a useful provocative maneuver to elicit triggers of atrial fibrillation (AF) during ablation. We evaluated whether the use of isoproterenol infusion to elicit triggers of AF after ablation is associated with differential outcomes. METHODS: We performed a retrospective study of all patients who underwent de novo radiofrequency catheter ablation of AF enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AAD). RESULTS: Of 314 patients undergoing AF ablation, 235 (74.8%) received isoproterenol while 79 (25.2%) did not. Among those who received isoproterenol, 11 (4.7%) had additional triggers identified. There were no statistically significant differences in procedure time (p = 0.432), antiarrhythmic drug use (p = 0.289), procedural complications (p = 0.279), recurrences of atrial arrhythmias on or off AAD [adjusted hazard ratio (AHR) 0.92 (95% CI 0.58-1.46); p = 0.714], all-cause hospitalizations [AHR 1.00 (95% CI 0.60-1.67); p = 0.986], or all-cause mortality [AHR 0.14 (95% CI 0.01-3.52); p = 0.229] between groups. CONCLUSIONS: In this registry analysis, use of isoproterenol is safe but was not associated with a reduction in recurrence of atrial arrhythmias.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Isoproterenol , Treatment Outcome , Retrospective Studies , Anti-Arrhythmia Agents/therapeutic use , Registries , Catheter Ablation/methods , Recurrence
12.
Circ Arrhythm Electrophysiol ; 15(9): e010857, 2022 09.
Article in English | MEDLINE | ID: mdl-36069189

ABSTRACT

BACKGROUND: The accuracy of noninvasive arrhythmia source localization using a forward-solution computational mapping system has not yet been evaluated in blinded, multicenter analysis. This study tested the hypothesis that a computational mapping system incorporating a comprehensive arrhythmia simulation library would provide accurate localization of the site-of-origin for atrial and ventricular arrhythmias and pacing using 12-lead ECG data when compared with the gold standard of invasive electrophysiology study and ablation. METHODS: The VMAP study (Vectorcardiographic Mapping of Arrhythmogenic Probability) was a blinded, multicenter evaluation with final data analysis performed by an independent core laboratory. Eligible episodes included atrial and ventricular: tachycardia, fibrillation, pacing, premature atrial and ventricular complexes, and orthodromic atrioventricular reentrant tachycardia. Mapping system results were compared with the gold standard site of successful ablation or pacing during electrophysiology study and ablation. Mapping time was assessed from time-stamped logs. Prespecified performance goals were used for statistical comparisons. RESULTS: A total of 255 episodes from 225 patients were enrolled from 4 centers. Regional accuracy for ventricular tachycardia and premature ventricular complexes in patients without significant structural heart disease (n=75, primary end point) was 98.7% (95% CI, 96.0%-100%; P<0.001 to reject predefined H0 <0.80). Regional accuracy for all episodes (secondary end point 1) was 96.9% (95% CI, 94.7%-99.0%; P<0.001 to reject predefined H0 <0.75). Accuracy for the exact or neighboring segment for all episodes (secondary end point 2) was 97.3% (95% CI, 95.2%-99.3%; P<0.001 to reject predefined H0 <0.70). Median spatial accuracy was 15 mm (n=255, interquartile range, 7-25 mm). The mapping process was completed in a median of 0.8 minutes (interquartile range, 0.4-1.4 minutes). CONCLUSIONS: Computational ECG mapping using a forward-solution approach exceeded prespecified accuracy goals for arrhythmia and pacing localization. Spatial accuracy analysis demonstrated clinically actionable results. This rapid, noninvasive mapping technology may facilitate catheter-based and noninvasive targeted arrhythmia therapies. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04559061.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Tachycardia, Ventricular , Ventricular Premature Complexes , Catheter Ablation/methods , Electrocardiography/methods , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery
13.
J Interv Card Electrophysiol ; 64(3): 715-722, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35169965

ABSTRACT

BACKGROUND: The mechanisms for atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) catheter ablation are unclear. Non-PV organized atrial arrhythmias (PAC, AT, macro-reentrant AFL) are possible contributors; however the prevalence and effect of their ablation on recurrent AF are unknown. We hypothesize that the identification and ablation of non-PV organized atrial arrhythmias were associated with less AF recurrence. METHODS: Patients who underwent repeat ablation for recurrent AF after prior PVI were retrospectively enrolled. The prevalence and characteristics of PV reconnections and non-PV organized atrial arrhythmias were identified. The outcomes of time to clinical AF recurrence, heart failure (HF) hospitalization, and mortality were analyzed in patients using multivariable adjusted Cox regression. RESULTS: In 74 patients with recurrent AF (age 66 ± 9 years, left atrial volume index 38 ± 10 ml/m2, 59% persistent AF), PV reconnections were found in 46 patients (61%), macro-reentrant atrial flutter in 27 patients (36%), and focal tachycardia in 12 patients (16%). Mapping and ablation of non-PV organized atrial arrhythmias were associated with a reduced recurrence of late clinical AF (adjusted HR 0.26, CI 0.08-0.85, p = 0.03) and the composite outcome of recurrence of late AF, HF hospitalization, and mortality (adjusted HR 0.38, CI 0.17-0.85, p = 0.02), with median follow-up of 1.6 (IQR 0.7-6.3) years. The presence of PV reconnections or empiric linear ablation was not associated with reduction in clinical AF or composite endpoints. CONCLUSION: The ablation of non-PV organized atrial arrhythmias resulted in a reduction of late clinical AF recurrence and composite outcome. In this challenging population, alternate mechanisms beyond PV reconnections need to be considered. Prospective studies are needed.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/epidemiology , Catheter Ablation/methods , Humans , Middle Aged , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
14.
J Interv Card Electrophysiol ; 63(1): 87-95, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33538952

ABSTRACT

PURPOSE: Mitral annular flutter (MAF) is a common arrhythmia after atrial fibrillation ablation. We sought to compare the efficacy and safety of catheter ablation utilizing either a left atrial anterior wall (LAAW) line or a lateral mitral isthmus (LMI) line. METHODS: We performed a systematic review for all studies that compared LAAW versus LMI lines. Risk ratio (RR) and mean difference (MD) 95% confidence intervals were measured for dichotomous and continuous variables, respectively. RESULTS: Four studies with a total of 594 patients were included, one of which was a randomized control trial. In the LMI ablation group, 40% of patients required CS ablation. There were no significant differences in bidirectional block (RR 1.26; 95% CI, 0.94-1.69) or ablation time (MD -1.5; 95% CI, -6.11-3.11), but LAAW ablation was associated with longer ablation line length (MD 11.42; 95% CI, 10.69-12.14) and longer LAA activation delay (MD 67.68; 95% CI, 33.47-101.89.14) when compared to LMI. There was no significant difference in pericardial effusions (RR 0.36; 95% CI, 0.39-20.75) between groups and more patients were maintained sinus rhythm (RR 1.19; 95% CI, 1.03-1.37, p = 0.02) who underwent LAAW compared to LMI. CONCLUSION: Ablation of mitral annular flutter with a LAAW line compared to a LMI line showed no difference in rates of acute bidirectional block, ablation time, or pericardial effusion. However, LAAW ablation required a longer ablation line length, resulted in greater LAA activation delayed and was associated with more sinus rhythm maintenance, with the added advantage of avoiding ablation in the CS.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Heart Atria/surgery , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Randomized Controlled Trials as Topic , Treatment Outcome
15.
J Interv Card Electrophysiol ; 64(2): 323-331, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33826085

ABSTRACT

PURPOSE: Early recurrence of atrial tachyarrhythmia (ER) is predictive of late recurrence of atrial tachyarrhythmia (LR) after first-time atrial fibrillation (AF) ablation, but the association in patients undergoing repeat AF ablation is unknown. We aim to determine the incidence and prognostic significance of ER after repeat ablation. METHODS: A total of 259 consecutive patients (mean age 64 years, 75.3% male) undergoing repeat AF ablation with complete follow-up data were included at a single institution from 2010 to 2015. ER and LR were defined as atrial tachyarrhythmia (AF, atrial flutter or atrial tachycardia) > 30 s within the 3-month blanking period (BP) and after the 3-month BP, respectively. RESULTS: ER occurred in 79/259 (30.5%), and LR occurred in 138/259 (53%) at a median follow-up of 1221 (IQR: 523-1712) days. Four-year freedom from LR was 22% and 56% in patients with and without ER, respectively (p < 0.001). After multivariate adjustment, ER was strongly associated with LR, cardioversion post BP, and repeat ablation, but not associated with hospitalization. Compared to those with no ER, there was a higher risk of LR when ER occurred within the first month of the BP [month 1: hazard ratio (HR) 2.32, confidence interval (CI) 1.57-3.74, p < 0.001; month 2: HR 2.01, CI 1.13-3.83, p = 0.02; month 3: HR 1.46, CI 0.5-3.36, p = 0.37], however the prediction of LR based on timing within the BP was poor (area under curve 0.64). CONCLUSION: Following repeat AF ablation, ER is strongly associated with LR, cardioversion post BP, and repeat ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/epidemiology , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Tachycardia/surgery , Treatment Outcome
16.
Comput Biol Med ; 141: 105050, 2022 02.
Article in English | MEDLINE | ID: mdl-34823858

ABSTRACT

Cardiac resynchronization therapy (CRT) is an established treatment for left bundle branch block (LBBB) resulting in mechanical dyssynchrony. Approximately 1/3 of patients with CRT, however, are non-responders. To understand factors affecting CRT response, an electromechanics-perfusion computational model based on animal-specific left ventricular (LV) geometry and coronary vascular networks located in the septum and LV free wall is developed. The model considers contractility-flow and preload-activation time relationships, and is calibrated to simultaneously match the experimental measurements in terms of the LV pressure, volume waveforms and total coronary flow in the left anterior descending and left circumflex territories from 2 swine models under right atrium and right ventricular pacing. The model is then applied to investigate the responses of CRT indexed by peak LV pressure and (dP/dt)max at multiple pacing sites with different degrees of perfusion in the LV free wall. Without the presence of ischemia, the model predicts that basal-lateral endocardial region is the optimal pacing site that can best improve (dP/dt)max by 20%, and is associated with the shortest activation time. In the presence of ischemia, a non-ischemic region becomes the optimal pacing site when coronary flow in the ischemic region fell below 30% of its original value. Pacing at the ischemic region produces little response at that perfusion level. The optimal pacing site is associated with one that optimizes the LV activation time. These findings suggest that CRT response is affected by both pacing site and coronary perfusion, which may have clinical implication in improving CRT responder rates.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Animals , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/methods , Computer Simulation , Heart Ventricles , Humans , Perfusion , Swine
17.
Heart Rhythm O2 ; 2(5): 511-520, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34667967

ABSTRACT

BACKGROUND: Stereotactic ablative radiotherapy (SAbR) is an emerging therapy for refractory ventricular tachycardia (VT). However, the current workflow is complicated, and the precision and safety in patients with significant cardiorespiratory motion and VT targets near the stomach may be suboptimal. OBJECTIVE: We hypothesized that automated 12-lead electrocardiogram (ECG) mapping and respiratory-gated therapy may improve the ease and precision of SAbR planning and facilitate safe radiation delivery in patients with refractory VT. METHODS: Consecutive patients with refractory VT were studied at 2 hospitals. VT exit sites were localized using a 3-D computational ECG algorithm noninvasively and compared to available prior invasive mapping. Radiotherapy (25 Gy) was delivered at end-expiration when cardiac respiratory motion was ≥0.6 cm or targets were ≤2 cm from the stomach. RESULTS: In 6 patients (ejection fraction 29% ± 13%), 4.2 ± 2.3 VT morphologies per patient were mapped. Overall, 7 out of 7 computational ECG mappings (100%) colocalized to the identical cardiac segment when prior invasive electrophysiology study was available. Respiratory gating was associated with smaller planning target volumes compared to nongated volumes (71 ± 7 vs 153 ± 35 cc, P < .01). In 2 patients with inferior wall VT targets close to the stomach (6 mm proximity) or significant respiratory motion (22 mm excursion), no GI complications were observed at 9- and 12-month follow-up. Implantable cardioverter-defibrillator shocks decreased from 23 ± 12 shocks/patient to 0.67 ± 1.0 (P < .001) post-SAbR at 6.0 ± 4.9 months follow-up. CONCLUSIONS: A workflow including computational ECG mapping and protocol-guided respiratory gating is feasible, is safe, and may improve the ease of SAbR planning. Studies to validate this workflow in larger populations are required.

18.
PLoS One ; 16(6): e0253266, 2021.
Article in English | MEDLINE | ID: mdl-34166392

ABSTRACT

PURPOSE: To evaluate if specific AADs prescribed in the blanking period (BP) after catheter ablation of atrial fibrillation (AF) may be associated with reduced risk of early recurrence (ER) and/or late recurrence (LR) of atrial arrhythmias. METHODS: A total of 478 patients undergoing first-time ablation at a single institution were included. Outcomes were: ER, LR, discontinuation of AAD less than 90 days post-ablation, and second ablation. ER was defined as AF, atrial flutter (AFL), or atrial tachycardia (AT) > 30 seconds within BP. LR was defined as AF/AFL/AT > 30 seconds after BP. RESULTS: Of 478 patients, 14.9% were prescribed no AAD, 26.4% propafenone/flecainide, 34.5% sotalol/dofetilide, 10.7% dronedarone, and 13.6% amiodarone. Patients prescribed amiodarone were more likely to have persistent AF, hypertension, diabetes, and other comorbidities. In unadjusted analyses, there were no differences between groups in relation to ER (log rank P = 0.171), discontinuation of AAD before ninety days post-ablation (log rank P = 0.235), or freedom from second ablation (log rank P = 0.147). After multivariable adjustment, patients prescribed amiodarone or dronedarone were more likely to experience LR than those prescribed no AAD [Adjusted Hazard Ratio (AHR) 1.83, 95% CI 1.10-3.04, p = 0.02; AHR 1.79, 95% CI 1.05-3.05, p = 0.03, respectively]. CONCLUSION: Following first-time catheter ablation, there were no differences between specific AAD prescription and risk of ER, while those prescribed amiodarone or dronedarone in the BP were more likely to experience LR than those prescribed no AAD, which may represent an association due to confounding by indication.


Subject(s)
Anti-Arrhythmia Agents/administration & dosage , Atrial Fibrillation/therapy , Catheter Ablation , Drug Prescriptions , Registries , Aged , Atrial Fibrillation/physiopathology , Female , Humans , Male , Middle Aged , Recurrence
19.
Am J Cardiol ; 142: 66-73, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33290688

ABSTRACT

Catheter ablation improves clinical outcomes in atrial fibrillation (AF) patients with heart failure (HF) with reduced ejection fraction (HFrEF). However, the role of catheter ablation in HF with a preserved ejection fraction (HFpEF) is less clear. We performed a literature search and systematic review of studies that compared AF recurrence at one year after catheter ablation of AF in patients with HFpEF versus those with HFrEF. Risk ratio (RR; where a RR <1.0 favors the HFpEF group) and mean difference (MD; where MD <0 favors the HFpEF group) 95% confidence intervals (CI) were measured for dichotomous and continuous variables, respectively. Six studies with a total of 1,505 patients were included, of which 764 (51%) had HFpEF and 741 (49%) had HFrEF. Patients with HFpEF experienced similar recurrence of AF 1 year after ablation on or off antiarrhythmic drugs compared with those with HFrEF (RR 1.01; 95% CI 0.76, 1.35). Fluoroscopy time was significantly shorter in the HFpEF group (MD -5.42; 95% CI -8.51, -2.34), but there was no significant difference in procedure time (MD 1.74; 95% CI -11.89, 15.37) or periprocedural adverse events between groups (RR 0.84; 95% CI 0.54,1.32). There was no significant difference in hospitalizations between groups (MD 1.18; 95% CI 0.90, 1.55), but HFpEF patients experienced significantly less mortality (MD 0.41; 95% CI 0.18, 0.94). In conclusion, based on the results of this meta-analysis, catheter ablation of AF in patients with HFpEF appears as safe and efficacious in maintaining sinus rhythm as in those with HFrEF.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Heart Failure/physiopathology , Stroke Volume , Atrial Fibrillation/complications , Heart Failure/complications , Hospitalization/statistics & numerical data , Humans , Mortality , Operative Time , Postoperative Complications/epidemiology , Recurrence , Treatment Outcome
20.
J Interv Card Electrophysiol ; 61(3): 479-485, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32757086

ABSTRACT

PURPOSE: Chronotropic incompetence (CI) in patients with heart failure is common and associated with impaired exercise intolerance and adverse outcomes. This study sought to determine the effects of closed loop stimulation (CLS) rate-adaptive pacing on functional capacity in patients with heart failure with reduced ejection fraction (HFrEF) and CI implanted with cardiac resynchronization therapy (CRT) devices. METHODS: A randomized, blinded, cross-over designed trial enrolled patients with HFrEF and CI implanted with a Biotronik CRT-D to complete a quality of life questionnaire, 6-min walk distance (6MWD), and cardiopulmonary exercise testing after two programmed periods: 1-week period of CLS and 1-week period of standard accelerometer (DDDR). RESULTS: Nine patients (6 males, mean age 71.4 years, 7 with New York Heart Association Class III, mean ejection fraction 39 ± 8%) were enrolled. Quality of life trended higher in CLS as compared to DDDR (550.8 ± 123.9 vs 489.3 ± 164.9, p = 0.06). There were no differences between CLS and DDDR in 6MWD (293.1 ± 90.2 m vs 315.1 ± 95.5 m, p = 0.52), peak heart rate (HR) 110.7 ± 14.7 bpm vs 109.7 bpm ± 14.1, p = 0.67), or peak VO2 (12.3 ± 4.9 ml/kg/min vs 12.9 ± 5.9, p = 0.47). As tests were submaximal as indicated by low respiratory exchange ratios (0.98 ± 0.11 vs 1.0 ± 0.8, p = 0.35), VE/VCO2 slope also showed no difference between CLS and DDDR (35.8 ± 5.6 vs 35.4 ± 5.7, p = 0.65). Five patients (56%) preferred CLS programming (p = 1.0). CONCLUSIONS: In patients with HFrEF and CI implanted with a CRT-D, peak HR, peak VO2, and 6MWD were equivalent, while there was a trend toward improved quality of life in CLS as compared to DDDR. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02693262.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Accelerometry , Aged , Female , Heart Failure/therapy , Humans , Male , Quality of Life , Stroke Volume