Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 21
1.
Med. oral patol. oral cir. bucal (Internet) ; 29(1): e145-e151, Ene. 2024. tab, ilus, graf
Article En | IBECS | ID: ibc-229199

Background: Concerning about the quality of room air has increased exponentially. Specially in dental clinicswhere diary practice is characterized by the important generation of aerosols.Material and Methods: An in vitro model was used in which samples were collected from the surfaces and roomair of a dental clinic before and after the use of an OH˙ radical generator.Results: A total of 1260 samples were collected for bacteriological analysis and 14 samples for the detection ofSARS-CoV-2. Following OH˙ treatment, the tested surface samples showed a decrease in the number of colonyforming units (CFUs) of 76.9% in TSA culture medium. The circulating room air samples in turn showed adecrease in CFUs of 66.7% in Sabouraud medium and 71.4% in Mannitol agar medium. No presence of SARS-CoV-2 was observed on the surface of the face shield.Conclusions: The disinfectant technology based on the use of hydroxyl radicals (OH˙) is effective in reducing thepresence of moulds and yeasts and Staphylococcus in the air, and in reducing total aerobic bacteria on the testedsurfaces.(AU)


Humans , Male , Female , In Vitro Techniques , Hydroxyl Radical , Dental Clinics , Disinfection , Biofouling , Dentistry , Oral Health , Oral Medicine , Oral Hygiene
2.
J Clin Exp Dent ; 15(6): e494-e504, 2023 Jun.
Article En | MEDLINE | ID: mdl-37388429

Background: A systematic review was carried out to compare the disinfectant capacity of hydroxyl radicals (OH-) versus other products commonly used for disinfecting the air and surfaces. Material and Methods: A literature search was made of the Cochrane Library, PubMed (MEDLINE) and Scopus databases. "In vitro" studies evaluating disinfection methods applicable to several surfaces and room air were included in the search. The search was carried out in April 2022, with no restrictions in terms of language or publication date. Results: Of the 308 articles identified from the initial search, 8 were included for the quantitative analysis. All publications corresponded to experimental "in vitro" studies. Seven of them evaluated biocidal action against bacteria, and only two assessed activity against viral loads. The generation of contaminants secondary to application of the disinfectants was only analyzed in one of the studies, with the conclusion that the production of peroxyl radicals (RO2) derived from the oxidation of volatile organic compounds (VOCs) is greater when chemical surface disinfectants are used versus air disinfection systems. Conclusions: The disinfection capacities of the currently available methods are similar, and none of them are able to replace the use of additional physical protection measures. Key words:Disinfection methods, hydroxyl radical, environment, surfaces, dentistry.

3.
Clin Oral Implants Res ; 34(5): 438-449, 2023 May.
Article En | MEDLINE | ID: mdl-36794798

OBJECTIVES: To assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches. METHODS: A double-arm randomized clinical trial was conducted. Consecutive partially edentulous patients were randomly allocated to the dCAIS or standard freehand approach groups. Implant placement accuracy was evaluated by overlapping the preoperative and postoperative Cone Beam Computer Tomographs (CBCT) and recording linear deviations at the implant apex and platform (in mm) and angular deviations (in degrees). Questionnaires recorded self-reported satisfaction, pain and QoL during surgery and postoperatively. RESULTS: Thirty patients (22 implants) were enrolled in each group. One patient was lost to follow-up. A significant difference (p < .001) in mean angular deviation was found between the dCAIS (4.02°; 95% CI: 2.85 to 5.19) and the FH (7.97°; 95% CI: 5.36 to 10.58) groups. Linear deviations were significantly lower in the dCAIS group, except for the apex vertical deviation, where no differences were found. Although dCAIS took 14 min longer (95% CI: 6.43 to 21.24; p < .001), patients in both groups considered the surgical time acceptable. Postoperative pain and analgesic consumption during the first postoperative week were similar between groups and self-reported satisfaction was very high. CONCLUSION: dCAIS systems significantly increase the accuracy of implant placement in partially edentulous patients in comparison with the conventional freehand approach. However, they increase the surgical time significantly and do not seem to improve patient satisfaction or reduce postoperative pain.


Dental Implants , Mouth, Edentulous , Surgery, Computer-Assisted , Humans , Quality of Life , Dental Implantation, Endosseous , Cone-Beam Computed Tomography , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Computer-Aided Design , Imaging, Three-Dimensional
4.
J Funct Biomater ; 14(2)2023 Jan 21.
Article En | MEDLINE | ID: mdl-36826860

Implantoplasty (IP) is used in dental implants with peri-implantitis and aims to remove threads and polish rough surfaces in order to prevent bacterial colonization. As a result of this procedure, implant strength might be compromised. We tested 20 tapered screw-shaped Ti6Al4V dental implants with a simulated bone loss of 50%. Ten implants underwent IP and 10 served as controls. Surface topography (Sa, Sz, Ssk, and Sdr) was analyzed with a confocal optical microscope. Subsequently, a minimum of four series of cyclic loads were applied with a servo-hydraulic mechanical testing machine (5 × 106 cycles at 15 Hz, between a maximal nominal value-starting at 529 N in the IP group and 735 N in the control group-and 10% of that force). We recorded the number of cycles until failure and the type of failure. Implant failure was analyzed by visual inspection and scanning electron microscopy. Open circuit potential and potenctiodynamic tests were carried out with high precision potentiostat using Hank's solution at 37 °C to evaluate the effect of the implantoplasty on the corrosion resistance. Implantoplasty significantly reduced the surface topography values (median) and interquartile range (IQR); Sa from 1.76 (IQR = 0.11) to 0.49 (IQR = 0.16), Sz from 20.98 (IQR = 8.14) to 8.19 (IQR = 4.16), Ssk from 0.01 (IQR = 0.34) to -0.74 (IQR = 0.53) and Sdr from 18.20 (IQR = 2.26) to 2.67 (IQR = 0.87). The fatigue limits of the control and implantoplasty groups were 551 N and 529 N, respectively. The scanning electron micrographs showed fatigue striations indicating fatigue failure. Besides, the fractographic analysis revealed a typical brittle intergranular fracture mechanism. The infinite life range of the dental implants evaluated was largely above the threshold of usual chewing forces. Implantoplasty seems to render a fairly smooth surface and has a limited impact on fatigue resistance. In addition, implantoplasty produces a decrease in the corrosion resistance of the implant. Corrosion current density from 0.019 µA/cm2 for as-received to 0.069 µA/cm2 in the interface smooth-roughened dental implant. These places between the machining and the rough area of the implant are the most susceptible, with the appearance of pitting.

5.
J Clin Exp Dent ; 14(6): e479-e485, 2022 Jun.
Article En | MEDLINE | ID: mdl-35765360

Background: Dry socket is one of the most common complications following tooth extraction, though no studies have been made on its main risk factors in the primary healthcare services of Barcelona (Spain). Objectives: To analyze the influence of different factors upon the appearance of dry socket in patients attended in the primary care setting, and to determine the possible presence of risk factors in patients who have suffered a previous episode of dry socket. Material and Methods: During 24 months, questionnaires were filled with data on the patients seen in different public primary healthcare services in the area of Barcelona (Spain). A case-control study was conducted to identify the main risk factors for developing complications in the form of dry socket. Results: A mandibular location of the extracted tooth, poor oral hygiene, difficult extraction, and previous dry socket increased the risk of developing this complication. In patients with dry socket in the past, the risk of developing the same complication again, adjusted for difficulty of extraction, was seen to increase 11.45-fold (OR: 11.45; 95%CI: 1.06 to 123.74; p = 0.045). Conclusions: The risk factors for dry socket are a mandibular location of the extracted tooth, poor oral hygiene, difficult extraction, and particularly a history of dry socket in the past. The identification of these factors the prevention of dry socket in each patient could be improved. Key words:Dry socket, risk factors, extraction, complications.

6.
Materials (Basel) ; 14(21)2021 Oct 29.
Article En | MEDLINE | ID: mdl-34772034

Implantoplasty is a mechanical decontamination technique that consists of polishing the supra-osseous component of the dental implant with peri-implantitis. This technique releases metal particles in the form of metal swarf and dust into the peri-implant environment. In the present in vitro study, the following physicochemical characterization tests were carried out: specific surface area, granulometry, contact angle, crystalline structure, morphology, and ion release. Besides, cytotoxicity was in turn evaluated by determining the fibroblastic and osteoblastic cell viability. As a result, the metal debris obtained by implantoplasty presented an equivalent diameter value of 159 µm (range 6-1850 µm) and a specific surface area of 0.3 m2/g on average. The particle had a plate-like shape of different sizes. The release of vanadium ions in Hank's solution at 37 °C showed no signs of stabilization and was greater than that of titanium and aluminum ions, which means that the alloy suffers from a degradation. The particles exhibited cytotoxic effects upon human osteoblastic and fibroblastic cells in the whole extract. In conclusion, metal debris released by implantoplasty showed different sizes, surface structures and shapes. Vanadium ion levels were higher than that those of the other metal ions, and cell viability assays showed that these particles produce a significant loss of cytocompatibility on osteoblasts and fibroblasts, which means that the main cells of the peri-implant tissues might be injured.

7.
Materials (Basel) ; 14(21)2021 Oct 29.
Article En | MEDLINE | ID: mdl-34772042

In the field of implant dentistry there are several mechanisms by which metal particles can be released into the peri-implant tissues, such as implant insertion, corrosion, wear, or surface decontamination techniques. The aim of this study was to evaluate the corrosion behavior of Ti6Al4V particles released during implantoplasty of dental implants treated due to periimplantitis. A standardized protocol was used to obtain metal particles produced during polishing the surface of Ti6Al4V dental implants. Physicochemical and biological characterization of the particles were described in Part I, while the mechanical properties and corrosion behavior have been studied in this study. Mechanical properties were determined by means of nanoindentation and X-ray diffraction. Corrosion resistance was evaluated by electrochemical testing in an artificial saliva medium. Corrosion parameters such as critical current density (icr), corrosion potential (ECORR), and passive current density (iCORR) have been determined. The samples for electrochemical behavior were discs of Ti6Al4V as-received and discs with the same mechanical properties and internal stresses than the particles from implantoplasty. The discs were cold-worked at 12.5% in order to achieve the same properties (hardness, strength, plastic strain, and residual stresses). The implantoplasty particles showed a higher hardness, strength, elastic modulus, and lower strain to fracture and a compressive residual stress. Resistance to corrosion of the implantoplasty particles decreased, and surface pitting was observed. This fact is due to the increase of the residual stress on the surfaces which favor the electrochemical reactions. The values of corrosion potential can be achieved in normal conditions and produce corroded debris which could be cytotoxic and cause tattooing in the soft tissues.

8.
J Clin Exp Dent ; 13(3): e278-e286, 2021 Mar.
Article En | MEDLINE | ID: mdl-33680330

BACKGROUND: A literature review was made to determine when third molar (3M) extraction is recommended in symptomatic patients and when it is not recommended. MATERIAL AND METHODS: A Medline (PubMed) and EMBASE search was made for articles related to indications for the extraction of 3Ms, published in the last 10 years and up until September 2018. RESULTS: The electronic search yielded 175 articles. After eliminating duplicates, a total of 173 articles were subjected to review of the title and abstract. Only 19 studies were finally included in the systematic review. There was a well documented increase in morbidity associated to impacted 3Ms (non-restorable caries, fracture, infection, periodontal disease, repeated pericoronitis, cysts and tumors), and in the presence of disease, extraction was considered to be indicated. The extraction of 3Ms with signs and/or symptoms of periodontal disease improved periodontal health at the distal surface of the second molar. Postoperative quality of life of patients with symptomatic 3Ms and with disease improved after surgical extraction. CONCLUSIONS: Extraction is indicated in the presence of disease associated to an impacted 3M, whether symptomatic or not. In contrast, extraction is not indicated in the absence of infection or other associated disease conditions. Key words:Third molar, periodontal disease, periodontitis, pericoronitis, dental caries, occlusal caries, mandibular cysts, osteomyelitis, odontogenic tumor.

9.
Med. oral patol. oral cir. bucal (Internet) ; 24(5): e583-e587, sept. 2019. ilus, tab
Article En | IBECS | ID: ibc-185674

Background: The reuse of implant healing abutments is common in dental practice. Effective elimination of bacteria and viruses is accomplished by conventional sterilization. The aim of this work was to explore the eventual survival of microorganisms on sterilized healing abutments and to rule out the presence of transmissible organic material after standard procedures. Material and Methods: A total of 55 healing abutments previously used in patients will be washed and sterilized in a steam autoclave at 121ºC for 15 min. Each healing abutment will be cultured in Brain Heart Infusion broth (BHI) under strict aseptic conditions. Besides, two control groups will be included: one of 3 unused healing abut-ments, and the other of just medium. After 10 days at 37°C under a 5% CO2 100 μl of the broth will be plated on solid media (Brain Infusion Agar, BHIA) and Columbia Blood agar to test for sterility. The remaining volume will be centrifuged, the sediment fixed, and a Gram stain performed to discard the presence of non-cultivable micro-organisms. Moreover, to determine the presence of remaining organic material after the cleaning and sterilizing treatments, the bioburden will be determined by measuring total organic carbon (TOC) in another 10 previously used healing abutments, cleaned and sterilized, that will be submerged in Milli-Q water and sonicated


No disponible


Humans , Dental Abutments , Dental Implants , Sterilization , Surface Properties , Titanium
10.
Clin Oral Implants Res ; 29(10): 1038-1049, 2018 Oct.
Article En | MEDLINE | ID: mdl-30267433

OBJECTIVE: This histomorphometric study compared bone regeneration potential of beta-tricalcium phosphate with fibronectin (ß-TCP-Fn) in critical-sized calvarial defects (CSDs) in rats to assess whether fibronectin (Fn) improved new bone formation. MATERIAL AND METHODS: Critical-sized calvarial defects were created in 30 adult male Sprague Dawley rats, which were divided into four groups according to the time of euthanasia (6 or 8 weeks of healing) and type of filling (ß-TCP-Fn/6 weeks, ß-TCP/6 weeks, ß-TCP-Fn/8 weeks and ß-TCP/8 weeks). The primary variables related to new bone formation were augmented area (AA) and gained tissue (GT; sum of mineralized bone matrix [MBM] and bone substitute [BS]). Secondary variables were the diameter of the defect, MBM, non-mineralized tissue (NMT) and BS. RESULTS: A total of 29 rats and 58 histological samples were evaluated, 28 (48.3%) samples obtained at 6 weeks and 30 (51.7%) at 8 weeks, homogeneously distributed between right and left sides. Thirteen (22.4%) were treated with ß-TCP-Fn, 16 (27.6%) with ß-TCP and 29 (50%) were controls. At 8 weeks, histomorphometric analysis showed significant differences in AA using ß-TCP and ß-TCP-Fn versus controls (p = 0.001 and p = 0.005, respectively). Bone turnover expressed as % within the target area was slightly higher but not statistically significant in the ß-TCP-Fn than in ß-TCP (MBM) at 6 weeks versus 8 weeks (p = 0.067 and p = 0.335, respectively). Finally, the total GT area in mm2 was higher using ß-TCP-Fn as compared to ß-TCP (p = 0.044). CONCLUSIONS: ß-TCP-Fn was slightly but non-significantly more effective than ß-TCP without Fn for improving the volume of regenerated bone in CSDs of rats, possibly allowing a more efficient bone remodelling process. This effect however should continue being investigated.


Bone Substitutes/therapeutic use , Calcium Phosphates/therapeutic use , Fibronectins/therapeutic use , Guided Tissue Regeneration/methods , Animals , Bone Regeneration/drug effects , Male , Rats , Rats, Sprague-Dawley , Skull/physiology , Skull/surgery
11.
Med. oral patol. oral cir. bucal (Internet) ; 20(6): e737-e743, nov. 2015. tab, ilus
Article En | IBECS | ID: ibc-144707

BACKGROUND: Interleukin-1 (IL-1) is a proinflammatory cytokine that plays an important role in the pathogenesis of periodontitis, and so it might be useful to detect high-risk cases of peri-implantitis. It has been reported that IL-1 polymorphisms and smoking habit have a synergic effect, increasing the incidence of peri-implantitis. The aim of the present study was to evaluate the relationship between IL-1 gene polymorphisms and peri-implantitis in smoking patients. MATERIAL AND METHODS: A case-control study was performed in 27 patients with peri-implantitis and 27 patients with healthy implants. All patients included were smokers. IL-1A-C889T, IL-1B+C3953T and IL-1RN+T2018C were identified by polymerase chain reaction (PCR) amplification in order to establish a relation between these variables and the presence of peri-implantitis. A bivariate analysis was performed and odds-ratio (OR) were calculated. RESULTS: The incidence of peri-implantitis was significantly higher in patients with previous history of periodontitis (p = 0.024; OR=10.9). Both groups were similar regarding IL-1A-C889T, IL-1B+C3953T and IL-1RN+T2018C genotypes. No increased risk in heavy smokers with IL-1 polymorphism was found. CONCLUSIONS: IL-1 genotypes do not seem to be good predictors of peri-implantitis in the great majority of smoking patients. Furthermore, no synergic effect was found between IL-1 genotypes and heavy smokers. Patients with a previous history of periodontitis were more prone to peri-implantitis


Adult , Female , Humans , Male , Middle Aged , Interleukin-1 , Receptors, Interleukin-1 Type I/analysis , Receptors, Interleukin-1 Type I/genetics , Smoking/pathology , Tobacco Use Disorder/complications , Tobacco Use Disorder/pathology , Peri-Implantitis/complications , Peri-Implantitis/diagnosis , Peri-Implantitis/prevention & control , Peri-Implantitis/physiopathology , Periodontitis/complications , Periodontitis/pathology , Polymerase Chain Reaction/methods , Odds Ratio , Polymorphism, Genetic
12.
Med Oral Patol Oral Cir Bucal ; 20(6): e737-43, 2015 Nov 01.
Article En | MEDLINE | ID: mdl-26449434

BACKGROUND: Interleukin-1 (IL-1) is a proinflammatory cytokine that plays an important role in the pathogenesis of periodontitis, and so it might be useful to detect high-risk cases of peri-implantitis. It has been reported that IL-1 polymorphisms and smoking habit have a synergic effect, increasing the incidence of peri-implantitis. The aim of the present study was to evaluate the relationship between IL-1 gene polymorphisms and peri-implantitis in smoking patients. MATERIAL AND METHODS: A case-control study was performed in 27 patients with peri-implantitis and 27 patients with healthy implants. All patients included were smokers. IL-1A-C889T, IL-1B+C3953T and IL-1RN+T2018C were identified by polymerase chain reaction (PCR) amplification in order to establish a relation between these variables and the presence of peri-implantitis. A bivariate analysis was performed and odds-ratio (OR) were calculated. RESULTS: The incidence of peri-implantitis was significantly higher in patients with previous history of periodontitis (p=0.024; OR=10.9). Both groups were similar regarding IL-1A-C889T, IL-1B+C3953T and IL-1RN+T2018C genotypes. No increased risk in heavy smokers with IL-1 polymorphism was found. CONCLUSIONS: IL-1 genotypes do not seem to be good predictors of peri-implantitis in the great majority of smoking patients. Furthermore, no synergic effect was found between IL-1 genotypes and heavy smokers. Patients with a previous history of periodontitis were more prone to peri-implantitis.


Interleukin-1/genetics , Peri-Implantitis/genetics , Polymorphism, Genetic , Smoking/genetics , Adult , Aged , Case-Control Studies , Female , Genotype , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
13.
Med Oral Patol Oral Cir Bucal ; 20(4): e480-8, 2015 Jul 01.
Article En | MEDLINE | ID: mdl-26034926

BACKGROUND: To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. MATERIAL AND METHODS: 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delayed loading. Failures, bone loss, probing depth and bleeding on probing were evaluated. RESULTS: 54 Mk III Shorty TiU and 15 Brånemark System®MK III TiU implants with a length longer than 7mm were included in the study. Twenty-eight implants were inserted following the immediate loading protocol and 26 according a two-stage procedure, depending on the torque value. The cumulative survival rate of short implants was 87% (n=54) after a mean time of 47.72 months (range 33-62 months), showing statistically significant differences related to loading protocol (p=0.047). Short implants immediately loaded had a higher long-term survival rate (96.4%) compared to the other study group (76.9%). Besides, short implants splinted to longer immediately loaded implants presented the highest survival rate (100%). Twenty-five (53.19%) short implants showed a bone loss of less than one millimeter after the follow-up period. Statistically significant differences were found between bleeding on probing, presence of plaque or suppuration and a higher bone loss in both loading protocols (p=0.001). CONCLUSIONS: Immediate loading of short implants placed on free ends can be considered an option in the treatment protocol of patients with severe bone resorption especially if implants are splinted to others of greater length.


Dental Implants , Dental Prosthesis Retention , Jaw, Edentulous/surgery , Adult , Aged , Dental Prosthesis Design , Female , Humans , Male , Middle Aged , Prospective Studies , Time Factors
14.
Med. oral patol. oral cir. bucal (Internet) ; 20(2): e239-e245, mar. 2015. ilus, tab
Article En | IBECS | ID: ibc-134139

OBJECTIVES: To compare the prevalence and the length of mental loop, measured with panoramic radiography (PR)and cone beam computerized tomography (CBCT).MATERIAL AND METHODS: PG and CBCT images where analyzed by a single calibrated examiner to determine the presence and the position of the mental foramen (MF), its distance to the lower mandible border, the anterior length of the mental loop (ML) and the bone quality in 82 PR and 82 CBCT. RESULTS: ML was identified in 36.6 % of PR and 48.8 % of CBCT. PR showed a magnification of 1.87 when compared to CBCT. The mean of anterior extension of the inferior alveolar nerve and the distance to the inferior border of the mandible was higher for PR (2.8 mm, sd 0.91 mm on the PR , range 1.5 to 4.7 mm and 1.59, sd 0.9 on the CBCT ,range 0.4 to 4.0 mm)CONCLUSIONS: There is a magnification in PR images with respect to those of CBCT. The differences between CBCT and PR with regards to the identification and length of the ML are not statistically significant. Identification and accuracy measurements of ML did not depend on the bone quality. Considering that two dimensional imaging provides less accurate and reliable information regarding the anterior loop, a CBCT scan could be recommended when planning implant placement in the anterior region


Humans , Cone-Beam Computed Tomography/methods , Radiography, Panoramic/methods , Dental Implantation/methods , Preoperative Care/methods , Tooth Apex/anatomy & histology
15.
Med Oral Patol Oral Cir Bucal ; 20(2): e239-45, 2015 Mar 01.
Article En | MEDLINE | ID: mdl-25549693

OBJECTIVES: To compare the prevalence and the length of mental loop, measured with panoramic radiography (PR) and cone beam computerized tomography (CBCT). MATERIAL AND METHODS: PG and CBCT images where analyzed by a single calibrated examiner to determine the presence and the position of the mental foramen (MF), its distance to the lower mandible border, the anterior length of the mental loop (ML) and the bone quality in 82 PR and 82 CBCT. RESULTS: ML was identified in 36.6 % of PR and 48.8 % of CBCT. PR showed a magnification of 1.87 when compared to CBCT. The mean of anterior extension of the inferior alveolar nerve and the distance to the inferior border of the mandible was higher for PR (2.8 mm, sd 0.91 mm on the PR , range 1.5 to 4.7 mm and 1.59, sd 0.9 on the CBCT ,range 0.4 to 4.0 mm) CONCLUSIONS: There is a magnification in PR images with respect to those of CBCT. The differences between CBCT and PR with regards to the identification and length of the ML are not statistically significant. Identification and accuracy measurements of ML did not depend on the bone quality. Considering that two dimensional imaging provides less accurate and reliable information regarding the anterior loop, a CBCT scan could be recommended when planning implant placement in the anterior region.


Cone-Beam Computed Tomography , Mandibular Nerve/diagnostic imaging , Radiography, Panoramic , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
16.
Med. oral patol. oral cir. bucal (Internet) ; 14(6): e295-e298, jun. 2009.
Article En | IBECS | ID: ibc-136371

Introduction: Moebius syndrome is a rare congenital disorder characterized by unilateral or bilateral involvement of the sixth and seventh cranial nerves, resulting in a lack of facial expression and eye movements. These patients suffer a series of oral manifestations that may complicate their dental treatment, such as facial and tongue muscle weakness, uncontrolled salivation secondary to deficient lip sealing, micrognathia, microstomia, bifid uvula, gothic and fissured palate, fissured tongue, and glossoptosis. The underlying etiology remains unclear, though vascular problems during embryogenesis appear to be involved. Clinical case: We report the case of a woman with Moebius syndrome and total edentulism. Eight years ago she underwent complete oral rehabilitation with the placement of two implants in each dental arch. Discussion: Moebius syndrome has still an unknown etiology, although it is related to disorders during pregnancy. This kind of patient can be rehabilitated using oral implants (AU)


Humans , Female , Middle Aged , Dental Implants , Mobius Syndrome/rehabilitation
17.
Clin Implant Dent Relat Res ; 11 Suppl 1: e38-45, 2009 Oct.
Article En | MEDLINE | ID: mdl-19438955

PURPOSE: To report on the clinical, radiological, and anatomical features of patients suffering accidental displacement of dental implants into the maxillary sinus. MATERIALS AND METHODS: A retrospective observational study of nine cases of dental implant displacement into the maxillary sinus was made. Data concerning patients' features, diagnostic criteria, and treatment performed were collected. RESULTS: Mean patient age was 56.7 years, and men predominated (6 : 3). Implant displacement was diagnosed in all cases by clinical and radiological examination. In seven patients, the implant was surgically removed without complications. Only three patients reported sinus symptoms following displacement. CONCLUSIONS: The displacement of implants into the maxillary sinus is usually related with a poor surgical planning or inadequate surgical technique. Because of the anatomy and physiology of the posterior area of the maxilla, it is essential to ensure good primary stability in order to avoid this complication. If the implant migrates into the maxillary sinus, it should be removed in order to avoid sinus pathology.


Dental Implants/adverse effects , Foreign Bodies , Maxillary Sinus , Adult , Aged , Dental Restoration Failure , Female , Foreign-Body Migration , Humans , Male , Middle Aged , Retrospective Studies
18.
Med Oral Patol Oral Cir Bucal ; 14(6): E295-8, 2009 Jun 01.
Article En | MEDLINE | ID: mdl-19300371

INTRODUCTION: Moebius syndrome is a rare congenital disorder characterized by unilateral or bilateral involvement of the sixth and seventh cranial nerves, resulting in a lack of facial expression and eye movements. These patients suffer a series of oral manifestations that may complicate their dental treatment, such as facial and tongue muscle weakness, uncontrolled salivation secondary to deficient lip sealing, micrognathia, microstomia, bifid uvula, gothic and fissured palate, fissured tongue, and glossoptosis. The underlying etiology remains unclear, though vascular problems during embryogenesis appear to be involved. CLINICAL CASE: We report the case of a woman with Moebius syndrome and total edentulism . Eight years ago she underwent complete oral rehabilitation with the placement of two implants in each dental arch. DISCUSSION: Moebius syndrome has still an unknown etiology, although it is related to disorders during pregnancy. This kind of patient can be rehabilitated using oral implants.


Dental Implants , Mobius Syndrome/rehabilitation , Female , Humans , Middle Aged
19.
Med. oral patol. oral cir. bucal (Internet) ; 13(2): 124-128, feb. 2008. ilus
Article En | IBECS | ID: ibc-67302

No disponible


Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture.Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths – while only two fractured implants were supporting overdentures instead of fixed prostheses. The great majority of fractured implants (80.9%) were located in the molar and premolar regions, and most fractured within 3-4 years after loading.It is important to know and apply the measures required to prevent implant fracture, and to seek the best individualized solution for each case - though complete implant removal is usually the treatment of choice


Humans , Dental Implantation, Endosseous , Dental Restoration Failure , Fractures, Bone/epidemiology , Osseointegration , Sex Distribution , Age Distribution
20.
Med Oral Patol Oral Cir Bucal ; 13(2): E124-8, 2008 Feb 01.
Article En | MEDLINE | ID: mdl-18223529

Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture. Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths - while only two fractured implants were supporting overdentures instead of fixed prostheses. The great majority of fractured implants (80.9%) were located in the molar and premolar regions, and most fractured within 3-4 years after loading. It is important to know and apply the measures required to prevent implant fracture, and to seek the best individualized solution for each case - though complete implant removal is usually the treatment of choice.


Dental Implants , Dental Restoration Failure , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
...