Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Trauma Acute Care Surg ; 91(1): 40-46, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33605703

ABSTRACT

BACKGROUND: Partial resuscitative endovascular balloon occlusion of the aorta (pREBOA) is a technology that occludes aortic flow and allows for controlled deflation and restoration of varying distal perfusion. Carotid flow rates (CFRs) during partial deflation are unknown. Our aim was to measure CFR with the different pREBOA balloon volumes and correlate those to the proximal mean arterial pressure (PMAP) and a handheld pressure monitoring device (COMPASS; Mirador Biomedical, Seattle, WA). METHODS: Ten swine underwent a hemorrhagic injury model with carotid and iliac arterial pressures monitored via arterial lines. Carotid and aortic flow rates were monitored with Doppler flow probes. A COMPASS was placed to monitor proximal pressure. The pREBOA was inflated for 15 minutes then partially deflated for an aortic flow rate of 0.7 L/min for 45 minutes. It was then completely deflated. Proximal mean arterial pressures and CFR were measured, and correlation was evaluated. Correlation between CRF and COMPASS measurements was evaluated. RESULTS: Carotid flow rate increased 240% with full inflation. Carotid flow rate was maintained at 100% to 150% of baseline across a wide range of partial deflation. After full deflation, CFR transiently decreased to 45% to 95% of baseline. There was strong positive correlation (r > 0.85) between CFR and PMAP after full inflation, and positive correlation with partial inflation (r > 0.7). Carotid flow rate had strong correlation with the COMPASS with full REBOA (r > 0.85) and positive correlation with pREBOA (r > 0.65). CONCLUSION: Carotid flow rate is increased in a hemorrhagic model during full and partial inflation of the pREBOA and correlates well with PMAP. Carotid perfusion appears maintained across a wide range of pREBOA deflation and could be readily monitored with a handheld portable COMPASS device instead of a standard arterial line setup.


Subject(s)
Balloon Occlusion/adverse effects , Cerebrovascular Circulation , Hemostatic Techniques/adverse effects , Resuscitation/adverse effects , Shock, Hemorrhagic/therapy , Animals , Aorta/surgery , Balloon Occlusion/instrumentation , Blood Flow Velocity , Carotid Arteries/physiology , Disease Models, Animal , Hemostatic Techniques/instrumentation , Humans , Male , Resuscitation/instrumentation , Resuscitation/methods , Swine
2.
J Trauma Acute Care Surg ; 90(4): 615-622, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33405469

ABSTRACT

BACKGROUND: Partial resuscitative endovascular balloon occlusion of the aorta (pREBOA) attempts to minimize ischemia/reperfusion injury while controlling hemorrhage. There are little data on optimal methods to evaluate and titrate partial flow, which typically requires invasive arterial line monitoring. We sought to examine the use of a miniaturized handheld digital pressure device (COMPASS; Mirador Biomedical, Seattle, WA) for pREBOA placement and titration of flow. METHODS: Ten swine underwent standardized hemorrhagic shock. Carotid and iliac pressures were monitored with both arterial line and COMPASS devices, and flow was monitored by aortic and superior mesenteric artery flow probes. Partial resuscitative endovascular balloon occlusion of the aorta was inflated to control hemorrhage for 15 minutes before being deflated to try targeting aortic flow of 0.7 L/min (using only the COMPASS device) by an operator blinded to the arterial line pressures and aortic flow. Correlations between COMPASS and proximal/distal arterial line were evaluated, as well as actual aortic flow. RESULTS: There was strong correlation between the distal mean arterial pressure (MAP) and the distal COMPASS MAP (r = 0.979, p < 0.01), as well as between the proximal arterial line and the proximal COMPASS on the pREBOA (r = 0.989, p < 0.01). There was a significant but weaker correlation between the distal compass MAP reading and aortic flow (r = 0.47, p < 0.0001), although it was not clinically significant and predicted flow was not achieved in a majority of the procedures. Of 10 pigs, survival times ranged from 10 to 120 minutes, with a mean survival of 50 minutes, and 1 pig surviving to 120 minutes. CONCLUSION: Highly reliable pressure monitoring is achieved proximally and distally without arterial lines using the COMPASS device on the pREBOA. Despite accurate readings, distal MAPs were a poor indicator of aortic flow, and titration based upon distal MAPs did not provide reliable results. Further investigation will be required to find a suitable proxy for targeting specific aortic flow levels using pREBOA.


Subject(s)
Balloon Occlusion , Blood Pressure Monitors , Endovascular Procedures , Point-of-Care Systems , Shock, Hemorrhagic/physiopathology , Shock, Hemorrhagic/therapy , Animals , Aorta/physiopathology , Arterial Pressure , Disease Models, Animal , Male , Reperfusion Injury/prevention & control , Reproducibility of Results , Resuscitation , Swine
3.
Proc Natl Acad Sci U S A ; 117(6): 3114-3122, 2020 02 11.
Article in English | MEDLINE | ID: mdl-31988134

ABSTRACT

Plasmodium falciparum vaccine RTS,S/AS01 is based on the major NPNA repeat and the C-terminal region of the circumsporozoite protein (CSP). RTS,S-induced NPNA-specific antibody titer and avidity have been associated with high-level protection in naïve subjects, but efficacy and longevity in target populations is relatively low. In an effort to improve upon RTS,S, a minimal repeat-only, epitope-focused, protective, malaria vaccine was designed. Repeat antigen copy number and flexibility was optimized using the tobacco mosaic virus (TMV) display platform. Comparing antigenicity of TMV displaying 3 to 20 copies of NPNA revealed that low copy number can reduce the abundance of low-affinity monoclonal antibody (mAb) epitopes while retaining high-affinity mAb epitopes. TMV presentation improved titer and avidity of repeat-specific Abs compared to a nearly full-length protein vaccine (FL-CSP). NPNAx5 antigen displayed as a loop on the TMV particle was found to be most optimal and its efficacy could be further augmented by combination with a human-use adjuvant ALFQ that contains immune-stimulators. These data were confirmed in rhesus macaques where a low dose of TMV-NPNAx5 elicited Abs that persisted at functional levels for up to 11 mo. We show here a complex association between NPNA copy number, flexibility, antigenicity, immunogenicity, and efficacy of CSP-based vaccines. We hypothesize that designing minimal epitope CSP vaccines could confer better and more durable protection against malaria. Preclinical data presented here supports the evaluation of TMV-NPNAx5/ALFQ in human trials.


Subject(s)
Antibodies, Protozoan/immunology , Malaria Vaccines , Malaria, Falciparum/immunology , Plasmodium falciparum , Protozoan Proteins , Tobacco Mosaic Virus/genetics , Animals , HEK293 Cells , Humans , Immunogenicity, Vaccine , Macaca mulatta , Malaria Vaccines/chemistry , Malaria Vaccines/genetics , Malaria Vaccines/immunology , Mice , Mice, Inbred C57BL , Models, Molecular , Plasmodium falciparum/genetics , Plasmodium falciparum/immunology , Protein Engineering , Protozoan Proteins/chemistry , Protozoan Proteins/genetics , Protozoan Proteins/immunology , Recombinant Fusion Proteins/chemistry , Recombinant Fusion Proteins/genetics , Recombinant Fusion Proteins/immunology
4.
PLoS One ; 13(11): e0207804, 2018.
Article in English | MEDLINE | ID: mdl-30475877

ABSTRACT

The elevated plus maze (EPM) is routinely used in neuroscience research to evaluate emotional behavior in rodents by measuring general exploratory performance and avoidance of the aversive open arms of the maze. According to standard practice, behavior on the EPM is evaluated during a single trial to avoid the possibility of habituation to the apparatus that would result in lost sensitivity of key outcome measures. However, this possibility has not been systematically evaluated across repeated trials or across different environmental conditions. In the current study, we assessed within-subject behavior on the EPM in adult male rats over thirteen trials (tested twice weekly) repeated under identical conditions. We also assessed within-subject behavior on the EPM in adult male rats under dim (1 lux in the closed arm) and lit (246 lux in the closed arm) environmental conditions. We found that measures of general performance (basic movements and total distanced travelled throughout the maze) were stable across repeated trials and environmental conditions. We found that measures of open arm avoidance (distance travelled in, time spent in and entries in to the open arm) varied across trials and environmental conditions and were sensitive to the lighting conditions of the initial test. Though measures of open arm avoidance did show a linear trend indicative of habituation across repeated trials, this effect was variable across trials. Notably, preference for the open arm over the closed arm (measured as % of time spent in the open arm) assessed among individual animals occurred rarely and was never observed on the group level across the thirteen repeated trials. Together, these data demonstrate that measures of general performance such as basic movements and total distance traveled are robust to repeated testing and changing environmental lighting conditions. In contrast, measures of open arm avoidance show habituation with repeated testing and are sensitive to changing environmental lighting conditions. Based on these results, we suggest that within-subjects repeated testing on the EPM is valid in well-controlled studies that include an untreated control group to account for inter-trial variability and habituation.


Subject(s)
Behavior, Animal/physiology , Maze Learning , Animals , Avoidance Learning , Male , Rats , Rats, Sprague-Dawley
5.
Am J Trop Med Hyg ; 97(6): 1857-1866, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29016296

ABSTRACT

To inform policy and decision makers, a cost-effectiveness model was developed to predict the cost-effectiveness of implementing two hypothetical management strategies separately and concurrently on the mitigation of deployment-associated travelers' diarrhea (TD) burden. The first management strategy aimed to increase the likelihood that a deployed service member with TD will seek medical care earlier in the disease course compared with current patterns; the second strategy aimed to optimize provider treatment practices through the implementation of a Department of Defense Clinical Practice Guideline. Outcome measures selected to compare management strategies were duty days lost averted (DDL-averted) and a cost effectiveness ratio (CER) of cost per DDL-averted (USD/DDL-averted). Increasing health care and by seeking it more often and earlier in the disease course as a stand-alone management strategy produced more DDL (worse) than the base case (up to 8,898 DDL-gained per year) at an increased cost to the Department of Defense (CER $193). Increasing provider use of an optimal evidence-based treatment algorithm through Clinical Practice Guidelines prevented 5,299 DDL per year with overall cost savings (CER -$74). A combination of both strategies produced the greatest gain in DDL-averted (6,887) with a modest cost increase (CER $118). The application of this model demonstrates that changes in TD management during deployment can be implemented to reduce DDL with likely favorable impacts on mission capability and individual health readiness. The hypothetical combination strategy evaluated prevents the most DDL compared with current practice and is associated with a modest cost increase.


Subject(s)
Diarrhea/economics , Diarrhea/therapy , Military Personnel , Travel-Related Illness , Acute Disease , Cost-Benefit Analysis , Disease Management , Health Care Costs , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...