Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
MAGMA ; 2024 May 04.
Article in English | MEDLINE | ID: mdl-38703246

ABSTRACT

OBJECTIVE: Diffusion-weighted MRI is a technique that can infer microstructural and microcirculatory features from biological tissue, with particular application to renal tissue. There is extensive literature on diffusion tensor imaging (DTI) of anisotropy in the renal medulla, intravoxel incoherent motion (IVIM) measurements separating microstructural from microcirculation effects, and combinations of the two. However, interpretation of these features and adaptation of more specific models remains an ongoing challenge. One input to this process is a whole organ distillation of corticomedullary contrast of diffusion metrics, as has been explored for other renal biomarkers. MATERIALS AND METHODS: In this work, we probe the spatial dependence of diffusion MRI metrics with concentrically layered segmentation in 11 healthy kidneys at 3 T. The metrics include those from DTI, IVIM, a combined approach titled "REnal Flow and Microstructure AnisotroPy (REFMAP)", and a multiply encoded model titled "FC-IVIM" providing estimates of fluid velocity and branching length. RESULTS: Fractional anisotropy decreased from the inner kidney to the outer kidney with the strongest layer correlation in both parenchyma (including cortex and medulla) and medulla with Spearman correlation coefficients and p-values (r, p) of (0.42, <0.001) and (0.37, <0.001), respectively. Also, dynamic parameters derived from the three models significantly decreased with a high correlation from the inner to the outer parenchyma or medulla with (r, p) ranges of (0.46-0.55, <0.001). CONCLUSIONS: These spatial trends might find implications for indirect assessments of kidney physiology and microstructure using diffusion MRI.

2.
J Magn Reson Imaging ; 2023 Nov 22.
Article in English | MEDLINE | ID: mdl-37991093

ABSTRACT

Diffusion measurements in the kidney are affected not only by renal microstructure but also by physiological processes (i.e., glomerular filtration, water reabsorption, and urine formation). Because of the superposition of passive tissue diffusion, blood perfusion, and tubular pre-urine flow, the limitations of the monoexponential apparent diffusion coefficient (ADC) model in assessing pathophysiological changes in renal tissue are becoming apparent and motivate the development of more advanced diffusion-weighted imaging (DWI) variants. These approaches take advantage of the fact that the length scale probed in DWI measurements can be adjusted by experimental parameters, including diffusion-weighting, diffusion gradient directions and diffusion time. This forms the basis by which advanced DWI models can be used to capture not only passive diffusion effects, but also microcirculation, compartmentalization, tissue anisotropy. In this review, we provide a comprehensive overview of the recent advancements in the field of renal DWI. Following a short introduction on renal structure and physiology, we present the key methodological approaches for the acquisition and analysis of renal DWI data, including intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI), non-Gaussian diffusion, and hybrid IVIM-DTI. We then briefly summarize the applications of these methods in chronic kidney disease and renal allograft dysfunction. Finally, we discuss the challenges and potential avenues for further development of renal DWI. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.

3.
J Magn Reson Imaging ; 2023 Sep 13.
Article in English | MEDLINE | ID: mdl-37702382

ABSTRACT

BACKGROUND: Monoexponential apparent diffusion coefficient (ADC) and biexponential intravoxel incoherent motion (IVIM) analysis of diffusion-weighted imaging is helpful in the characterization of breast tumors. However, repeatability/reproducibility studies across scanners and across sites are scarce. PURPOSE: To evaluate the repeatability and reproducibility of ADC and IVIM parameters (tissue diffusivity (Dt ), perfusion fraction (Fp ) and pseudo-diffusion (Dp )) within and across sites employing MRI scanners from different vendors utilizing 16-channel breast array coils in a breast diffusion phantom. STUDY TYPE: Phantom repeatability. PHANTOM: A breast phantom containing tubes of different polyvinylpyrrolidone (PVP) concentrations, water, fat, and sponge flow chambers, together with an MR-compatible liquid crystal (LC) thermometer. FIELD STRENGTH/SEQUENCE: Bipolar gradient twice-refocused spin echo sequence and monopolar gradient single spin echo sequence at 3 T. ASSESSMENT: Studies were performed twice in each of two scanners, located at different sites, on each of 2 days, resulting in four studies per scanner. ADCs of the PVP and water were normalized to the vendor-provided calibrated values at the temperature indicated by the LC thermometer for repeatability/reproducibility comparisons. STATISTICAL TESTS: ADC and IVIM repeatability and reproducibility within and across sites were estimated via the within-system coefficient of variation (wCV). Pearson correlation coefficient (r) was also computed between IVIM metrics and flow speed. A P value <0.05 was considered statistically significant. RESULTS: ADC and Dt demonstrated excellent repeatability (<2%; <3%, respectively) and reproducibility (both <5%) at the two sites. Fp and Dp exhibited good repeatability (mean of two sites 3.67% and 5.59%, respectively) and moderate reproducibility (mean of two sites 15.96% and 13.3%, respectively). The mean intersite reproducibility (%) of Fp /Dp /Dt was 50.96/13.68/5.59, respectively. Fp and Dt demonstrated high correlations with flow speed while Dp showed lower correlations. Fp correlations with flow speed were significant at both sites. DATA CONCLUSION: IVIM reproducibility results were promising and similar to ADC, particularly for Dt . The results were reproducible within both sites, and a progressive trend toward reproducibility across sites except for Fp . LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

4.
Magn Reson Imaging ; 100: 93-101, 2023 07.
Article in English | MEDLINE | ID: mdl-36924807

ABSTRACT

PURPOSE: Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS: In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS: Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS: Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.


Subject(s)
Diffusion Magnetic Resonance Imaging , Diffusion Tensor Imaging , Humans , Adult , Middle Aged , Prospective Studies , Diffusion Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging , Kidney/diagnostic imaging , Echo-Planar Imaging/methods , Motion
5.
J Magn Reson Imaging ; 58(1): 210-220, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36399101

ABSTRACT

BACKGROUND: Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE: To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE: Prospective. POPULATION: Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE: 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT: BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS: Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS: Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 µm tubule diameter. DATA CONCLUSION: Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Diffusion Tensor Imaging , Kidney , Female , Humans , Young Adult , Adult , Middle Aged , Diffusion Tensor Imaging/methods , Anisotropy , Prospective Studies , Retrospective Studies , Kidney/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Motion , Water
6.
Eur Radiol ; 32(10): 6588-6597, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35507050

ABSTRACT

OBJECTIVES: To perform a survey among all European Society of Breast Imaging (EUSOBI) radiologist members to gather representative data regarding the clinical use of breast DWI. METHODS: An online questionnaire was developed by two board-certified radiologists, reviewed by the EUSOBI board and committees, and finally distributed among EUSOBI active and associated (not based in Europe) radiologist members. The questionnaire included 20 questions pertaining to technical preferences (acquisition time, magnet strength, breast coils, number of b values), clinical indications, imaging evaluation, and reporting. Data were analyzed using descriptive statistics, the Chi-square test of independence, and Fisher's exact test. RESULTS: Of 1411 EUSOBI radiologist members, 275/1411 (19.5%) responded. Most (222/275, 81%) reported using DWI as part of their routine protocol. Common indications for DWI include lesion characterization (using an ADC threshold of 1.2-1.3 × 10-3 mm2/s) and prediction of response to chemotherapy. Members most commonly acquire two separate b values (114/217, 53%), with b value = 800 s/mm2 being the preferred value for appraisal among those acquiring more than two b values (71/171, 42%). Most did not use synthetic b values (169/217, 78%). While most mention hindered diffusion in the MRI report (161/213, 76%), only 142/217 (57%) report ADC values. CONCLUSION: The utilization of DWI in clinical practice among EUSOBI radiologists who responded to the survey is generally in line with international recommendations, with the main application being the differentiation of benign and malignant enhancing lesions, treatment response assessment, and prediction of response to chemotherapy. Report integration of qualitative and quantitative DWI data is not uniform. KEY POINTS: • Clinical performance of breast DWI is in good agreement with the current recommendations of the EUSOBI International Breast DWI working group. • Breast DWI applications in clinical practice include the differentiation of benign and malignant enhancing, treatment response assessment, and prediction of response to chemotherapy. • Report integration of DWI results is not uniform.


Subject(s)
Breast Neoplasms , Diffusion Magnetic Resonance Imaging , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Diffusion Magnetic Resonance Imaging/methods , Female , Humans , Magnetic Resonance Imaging/methods , Sensitivity and Specificity , Surveys and Questionnaires
7.
J Magn Reson Imaging ; 55(4): 988-1012, 2022 04.
Article in English | MEDLINE | ID: mdl-34390617

ABSTRACT

Throughout the body, muscle structure and function can be interrogated using a variety of noninvasive magnetic resonance imaging (MRI) methods. Recently, intravoxel incoherent motion (IVIM) MRI has gained momentum as a method to evaluate components of blood flow and tissue diffusion simultaneously. Much of the prior research has focused on highly vascularized organs, including the brain, kidney, and liver. Unique aspects of skeletal muscle, including the relatively low perfusion at rest and large dynamic range of perfusion between resting and maximal hyperemic states, may influence the acquisition, postprocessing, and interpretation of IVIM data. Here, we introduce several of those unique features of skeletal muscle; review existing studies of IVIM in skeletal muscle at rest, in response to exercise, and in disease states; and consider possible confounds that should be addressed for muscle-specific evaluations. Most studies used segmented nonlinear least squares fitting with a b-value threshold of 200 sec/mm2 to obtain IVIM parameters of perfusion fraction (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D). In healthy individuals, across all muscles, the average ± standard deviation of D was 1.46 ± 0.30 × 10-3  mm2 /sec, D* was 29.7 ± 38.1 × 10-3  mm2 /sec, and f was 11.1 ± 6.7%. Comparisons of reported IVIM parameters in muscles of the back, thigh, and leg of healthy individuals showed no significant difference between anatomic locations. Throughout the body, exercise elicited a positive change of all IVIM parameters. Future directions including advanced postprocessing models and potential sequence modifications are discussed. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Subject(s)
Diffusion Magnetic Resonance Imaging , Magnetic Resonance Imaging , Diffusion Magnetic Resonance Imaging/methods , Exercise/physiology , Humans , Magnetic Resonance Imaging/methods , Motion , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology
8.
J Comput Assist Tomogr ; 45(2): 218-223, 2021.
Article in English | MEDLINE | ID: mdl-33661149

ABSTRACT

ABSTRACT: Renal echo planar diffusion tensor imaging (DTI) has clinical potential but suffers from geometric distortion. We evaluated feasibility of reversed gradient distortion correction in 10 diabetic patients and 6 volunteers. Renal area, apparent diffusion coefficient, fractional anisotropy, and tensor eigenvalues were measured on uncorrected and distortion-corrected DTI. Corrected DTI correlated better than uncorrected DTI (r = 0.904 vs 0.840, P = 0.002) with reference anatomic T2-weighted imaging, with no significant difference in DTI metrics.


Subject(s)
Diffusion Tensor Imaging/methods , Image Interpretation, Computer-Assisted/methods , Kidney/diagnostic imaging , Adult , Diabetic Nephropathies/diagnostic imaging , Feasibility Studies , Humans , Middle Aged , Young Adult
10.
Eur Radiol ; 30(3): 1436-1450, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31786616

ABSTRACT

The European Society of Breast Radiology (EUSOBI) established an International Breast DWI working group. The working group consists of clinical breast MRI experts, MRI physicists, and representatives from large vendors of MRI equipment, invited based upon proven expertise in breast MRI and/or in particular breast DWI, representing 25 sites from 16 countries. The aims of the working group are (a) to promote the use of breast DWI into clinical practice by issuing consensus statements and initiate collaborative research where appropriate; (b) to define necessary standards and provide practical guidance for clinical application of breast DWI; (c) to develop a standardized and translatable multisite multivendor quality assurance protocol, especially for multisite research studies; (d) to find consensus on optimal methods for image processing/analysis, visualization, and interpretation; and (e) to work collaboratively with system vendors to improve breast DWI sequences. First consensus recommendations, presented in this paper, include acquisition parameters for standard breast DWI sequences including specifications of b values, fat saturation, spatial resolution, and repetition and echo times. To describe lesions in an objective way, levels of diffusion restriction/hindrance in the breast have been defined based on the published literature on breast DWI. The use of a small ROI placed on the darkest part of the lesion on the ADC map, avoiding necrotic, noisy or non-enhancing lesion voxels is currently recommended. The working group emphasizes the need for standardization and quality assurance before ADC thresholds are applied. The working group encourages further research in advanced diffusion techniques and tailored DWI strategies for specific indications. Key Points • The working group considers breast DWI an essential part of a multiparametric breast MRI protocol and encourages its use. • Basic requirements for routine clinical application of breast DWI are provided, including recommendations on b values, fat saturation, spatial resolution, and other sequence parameters. • Diffusion levels in breast lesions are defined based on meta-analysis data and methods to obtain a reliable ADC value are detailed.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Breast/pathology , Breast Neoplasms/pathology , Consensus , Female , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Sensitivity and Specificity
11.
Neuroimage ; 204: 116228, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31580945

ABSTRACT

At very low diffusion weighting the diffusion MRI signal is affected by intravoxel incoherent motion (IVIM) caused by dephasing of magnetization due to incoherent blood flow in capillaries or other sources of microcirculation. While IVIM measurements at low diffusion weightings have been frequently used to investigate perfusion in the body as well as in malignant tissue, the effect and origin of IVIM in normal brain tissue is not completely established. We investigated the IVIM effect on the brain diffusion MRI signal in a cohort of 137 radiologically-normal patients (62 male; mean age = 50.2 ±â€¯17.8, range = 18 to 94). We compared the diffusion tensor parameters estimated from a mono-exponential fit at b = 0 and 1000 s/mm2 versus at b = 250 and 1000 s/mm2. The asymptotic fitting method allowed for quantitative assessment of the IVIM signal fraction f* in specific brain tissue and regions. Our results show a mean (median) percent difference in the mean diffusivity of about 4.5 (4.9)% in white matter (WM), about 7.8 (8.7)% in cortical gray matter (GM), and 4.3 (4.2)% in thalamus. Corresponding perfusion fraction f* was estimated to be 0.033 (0.032) in WM, 0.066 (0.065) in cortical GM, and 0.033 (0.030) in the thalamus. The effect of f* with respect to age was found to be significant in cortical GM (Pearson correlation ρ â€‹= â€‹0.35, p â€‹= â€‹3*10-5) and the thalamus (Pearson correlation ρ = 0.20, p = 0.022) with an average increase in f* of 5.17*10-4/year and 3.61*10-4/year, respectively. Significant correlations between f* and age were not observed for WM, and corollary analysis revealed no effect of gender on f*. Possible origins of the IVIM effect in normal brain tissue are discussed.


Subject(s)
Cerebral Cortex/diagnostic imaging , Diffusion Magnetic Resonance Imaging/standards , Gray Matter/diagnostic imaging , Microcirculation , Neuroimaging/standards , Thalamus/diagnostic imaging , White Matter/diagnostic imaging , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Cerebral Cortex/blood supply , Diffusion Magnetic Resonance Imaging/methods , Female , Gray Matter/blood supply , Humans , Male , Microcirculation/physiology , Middle Aged , Motion , Neuroimaging/methods , Sex Factors , Thalamus/blood supply , White Matter/blood supply , Young Adult
12.
MAGMA ; 33(1): 177-195, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31676990

ABSTRACT

OBJECTIVES: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. MATERIALS AND METHODS: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. RESULTS: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65-74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. DISCUSSION: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.


Subject(s)
Biomarkers/metabolism , Diffusion Magnetic Resonance Imaging , Kidney/diagnostic imaging , Translational Research, Biomedical , Algorithms , Consensus , Delphi Technique , Humans , Image Interpretation, Computer-Assisted/methods , Kidney/metabolism , Models, Statistical , Motion , Reproducibility of Results , Surveys and Questionnaires
13.
J Magn Reson Imaging ; 52(1): 70-90, 2020 07.
Article in English | MEDLINE | ID: mdl-31520518

ABSTRACT

Diffusion-weighted imaging (DWI) is increasingly being incorporated into routine breast MRI protocols in many institutions worldwide, and there are abundant breast DWI indications ranging from lesion detection and distinguishing malignant from benign tumors to assessing prognostic biomarkers of breast cancer and predicting treatment response. DWI has the potential to serve as a noncontrast MR screening method. Beyond apparent diffusion coefficient (ADC) mapping, which is a commonly used quantitative DWI measure, advanced DWI models such as intravoxel incoherent motion (IVIM), non-Gaussian diffusion MRI, and diffusion tensor imaging (DTI) are extensively exploited in this field, allowing the characterization of tissue perfusion and architecture and improving diagnostic accuracy without the use of contrast agents. This review will give a summary of the clinical literature along with future directions. Level of Evidence: 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;52:70-90.


Subject(s)
Breast Neoplasms , Diffusion Tensor Imaging , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Female , Humans , Motion , Reproducibility of Results
15.
J Magn Reson Imaging ; 48(1): 188-197, 2018 07.
Article in English | MEDLINE | ID: mdl-29331053

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) provides insight into the pathophysiology underlying renal dysfunction. Variants of DWI include intravoxel incoherent motion (IVIM), which differentiates between microstructural diffusion and vascular or tubular flow, and diffusion tensor imaging (DTI), which quantifies diffusion directionality. PURPOSE: To investigate the reproducibility of joint IVIM-DTI and compare controls to presurgical renal mass patients. STUDY TYPE: Prospective cross-sectional. SUBJECTS: Thirteen healthy controls and ten presurgical renal mass patients were scanned. Ten controls were scanned twice to investigate reproducibility. FIELD STRENGTH/SEQUENCE: Subjects were scanned on a 3T system using 10 b-values and 20 diffusion directions for IVIM-DTI in a study approved by the local Institutional Review Board. ASSESSMENT: Retrospective coregistration and measurement of joint IVIM-DTI parameters were performed. STATISTICAL ANALYSIS: Parameter reproducibility was defined as intraclass correlation coefficient (ICC) >0.7 and coefficient of variation (CV) <30%. Patient data were stratified by lesion side (contralateral/ipsilateral) for comparison with controls. Corticomedullary differentiation was evaluated. RESULTS: In controls, the reproducible subset of REnal Flow and Microstructure AnisotroPy (REFMAP) parameters had average ICC = 0.82 and CV = 7.5%. In renal mass patients, medullary fractional anisotropy (FA) was significantly lower than in controls (0.227 ± 0.072 vs. 0.291 ± 0.044, P = 0.016 for the kidney contralateral to the mass and 0.228 ± 0.070 vs. 0.291 ± 0.044, P = 0.018 for the kidney ipsilateral). In the kidney ipsilateral to the mass, cortical Dp,radial was significantly higher than in controls (P = 0.012). Conversely, medullary Dp,axial was significantly lower in contralateral than ipsilateral kidneys (P = 0.027) and normal controls (P = 0.044). DATA CONCLUSION: REFMAP-MRI parameters provide unique information regarding renal dysfunction. In presurgical renal mass patients, directional flow changes were noted that were not identified with IVIM analysis alone. Both contralateral and ipsilateral kidneys in patients show reductions in structural diffusivities and anisotropy, while flow metrics showed opposing changes in contralateral vs. ipsilateral kidneys. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.


Subject(s)
Diffusion Magnetic Resonance Imaging , Kidney Neoplasms/diagnostic imaging , Kidney/diagnostic imaging , Adult , Aged , Aged, 80 and over , Anisotropy , Body Mass Index , Cross-Sectional Studies , Diffusion Tensor Imaging , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted , Male , Middle Aged , Motion , Normal Distribution , Preoperative Period , Prospective Studies , Reproducibility of Results , Retrospective Studies
16.
Eur J Radiol Open ; 4: 101-107, 2017.
Article in English | MEDLINE | ID: mdl-28856177

ABSTRACT

OBJECTIVE: To examine the prognostic capabilities of intravoxel incoherent motion (IVIM) metrics and their ability to predict response to neoadjuvant treatment (NAT). Additionally, to observe changes in IVIM metrics between pre- and post-treatment MRI. METHODS: This IRB-approved, HIPAA-compliant retrospective study observed 31 breast cancer patients (32 lesions). Patients underwent standard bilateral breast MRI along with diffusion-weighted imaging before and after NAT. Six patients underwent an additional IVIM-MRI scan 12-14 weeks after initial scan and 2 cycles of treatment. In addition to apparent diffusion coefficients (ADC) from monoexponential decay, IVIM mean values (tissue diffusivity Dt, perfusion fraction fp, and pseudodiffusivity Dp) and histogram metrics were derived using a biexponential model. An additional filter identified voxels of highly vascular tumor tissue (VTT), excluding necrotic or normal tissue. Clinical data include histology of biopsy and clinical response to treatment through RECIST assessment. Comparisons of treatment response were made using Wilcoxon rank-sum tests. RESULTS: Average, kurtosis, and skewness of pseudodiffusion Dp significantly differentiated RECIST responders from nonresponders. ADC and Dt values generally increased (∼70%) and VTT% values generally decreased (∼20%) post-treatment. CONCLUSION: Dp metrics showed prognostic capabilities; slow and heterogeneous pseudodiffusion offer poor prognosis. Baseline ADC/Dt parameters were not significant predictors of response. This work suggests that IVIM mean values and heterogeneity metrics may have prognostic value in the setting of breast cancer NAT.

17.
J Magn Reson Imaging ; 45(2): 337-355, 2017 02.
Article in English | MEDLINE | ID: mdl-27690173

ABSTRACT

Diffusion-weighted MRI (DWI) holds potential to improve the detection and biological characterization of breast cancer. DWI is increasingly being incorporated into breast MRI protocols to address some of the shortcomings of routine clinical breast MRI. Potential benefits include improved differentiation of benign and malignant breast lesions, assessment and prediction of therapeutic efficacy, and noncontrast detection of breast cancer. The breast presents a unique imaging environment with significant physiologic and inter-subject variations, as well as specific challenges to achieving reliable high quality diffusion-weighted MR images. Technical innovations are helping to overcome many of the image quality issues that have limited widespread use of DWI for breast imaging. Advanced modeling approaches to further characterize tissue perfusion, complexity, and glandular organization may expand knowledge and yield improved diagnostic tools. LEVEL OF EVIDENCE: 5 J. Magn. Reson. Imaging 2016 J. Magn. Reson. Imaging 2017;45:337-355.


Subject(s)
Algorithms , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Breast/diagnostic imaging , Breast/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Diffusion Magnetic Resonance Imaging/trends , Evidence-Based Medicine , Female , Humans , Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
18.
J Magn Reson Imaging ; 45(1): 84-93, 2017 01.
Article in English | MEDLINE | ID: mdl-27441890

ABSTRACT

PURPOSE: To explore the application of diffusion tensor imaging (DTI) for breast tissue and breast pathologies using a stimulated-echo acquisition mode (STEAM) with variable diffusion times. MATERIALS AND METHODS: In this Health Insurance Portability and Accountability Act-compliant study, approved by the local institutional review board, eight patients and six healthy volunteers underwent an MRI examination at 3 Tesla including STEAM-DTI with several diffusion times ranging from 68.5 to 902.5 ms. A DTI model was fitted to the data for each diffusion time, and parametric maps of mean diffusivity, fractional anisotropy, axial diffusivity, and radial diffusivity were computed for healthy fibroglandular tissue (FGT) and lesions. The median value of radial diffusivity for FGT was fitted to a linear decay to obtain an estimation of the surface-to-volume ratio, from which the radial diameter was calculated. RESULTS: For healthy FGT, radial diffusivity presented a linear decay with the square root of the diffusion time resulting in a range of estimated radial diameters from 202 to 496 µm, while axial diffusivity presented a nearly time-independent diffusion. Residual fat signal was reduced at longer diffusion times due to the shorter T1 of fat. Residual fat signal to the overall signal in the healthy volunteers' FGT was found to range from 2.39% to 2.55% (shortest mixing time), and from 0.40% to 0.51% (longest mixing time) for the b500 images. CONCLUSION: The use of variable diffusion times may provide an in vivo noninvasive tool to probe diffusion lengths in breast tissue and breast pathology, and might aid by improving fat suppression at longer diffusion times. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:84-93.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Diffusion Tensor Imaging/methods , Echo-Planar Imaging/methods , Image Interpretation, Computer-Assisted/methods , Adult , Aged , Diffusion , Female , Humans , Image Enhancement/methods , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
19.
Magn Reson Med ; 78(3): 1147-1156, 2017 09.
Article in English | MEDLINE | ID: mdl-27779790

ABSTRACT

PURPOSE: Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusion, and glucose avidity in breast cancer with simultaneous PET/MR imaging and compares correlations with clinical prognostics. METHODS: In this Health Insurance Portability and Accountability Act-compliant prospective study, with written informed consent and approval of the institutional review board and using simultaneously acquired FDG-PET and DWI, tissue diffusion (Dt ), and perfusion fraction (fp ) from intravoxel incoherent motion (IVIM) analysis were registered to FDG-PET within 14 locally advanced breast cancers. Lesions were analyzed using 2D histograms and correlation coefficients between Dt , fp , and standardized uptake value (SUV). Correlations were compared with prognostics from biopsy, metastatic burden from whole-body PET, and treatment history. RESULTS: SUV||Dt correlation coefficient significantly distinguished treated (0.11 ± 0.24) from nontreated (-0.33 ± 0.26) patients (P = 0.005). SUV||fp correlations were on average negative for the whole cohort (-0.17 ± 0.13). CONCLUSION: Simultaneously acquired and registered FDG-PET/DWI allowed quantifiable descriptions of breast cancer microenvironments that may provide a framework for monitoring and predicting response to treatment. Magn Reson Med 78:1147-1156, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Positron-Emission Tomography/methods , Adult , Aged , Female , Fluorodeoxyglucose F18 , Humans , Middle Aged , Movement/physiology
20.
NMR Biomed ; 30(3)2017 Mar.
Article in English | MEDLINE | ID: mdl-27717099

ABSTRACT

The time dependence of the diffusion coefficient is a hallmark of tissue complexity at the micrometer level. Here we demonstrate how biophysical modeling, combined with a specifically tailored diffusion MRI acquisition performing diffusion tensor imaging (DTI) for varying diffusion times, can be used to determine fiber size and membrane permeability of muscle fibers in vivo. We describe the random permeable barrier model (RPBM) and its assumptions, as well as the details of stimulated echo DTI acquisition, signal processing steps, and potential pitfalls. We illustrate the RPBM method on a few pilot examples involving human subjects (previously published as well as new), such as revealing myofiber size derived from RPBM increase after training in a calf muscle, and size decrease with atrophy in shoulder rotator cuff muscle. Finally, we comment on the potential clinical relevance of our results. Copyright © 2016 John Wiley & Sons, Ltd.


Subject(s)
Cell Membrane Permeability/physiology , Diffusion Tensor Imaging/methods , Image Interpretation, Computer-Assisted/methods , Muscle Fibers, Skeletal/cytology , Muscle Fibers, Skeletal/physiology , Muscle, Skeletal/cytology , Muscle, Skeletal/physiology , Adult , Computer Simulation , Humans , Male , Middle Aged , Models, Biological , Models, Statistical , Muscle, Skeletal/diagnostic imaging , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL