1.
Orphanet J Rare Dis ; 15(1): 26, 2020 01 22.
Article in English | MEDLINE | ID: mdl-31969179

ABSTRACT

To compare the similarity of the non-patented T2* and the high cost patented R2 (Ferriscan®) MRI techniques in the measurement of liver iron concentration (LIC) in heavily transfused patients with thalassaemia major in a real- life Sri Lankan hospital setup. We compared LIC measured by MRI, obtained 2 weeks apart, using both T2* and R2 techniques in 15 patients with beta thalassaemia major. They all had a history of > 100 units of blood transfusions life long and also a history of sub optimal chelation. MRI R2 and MRI T2* scan values showed a negative correlation (co-rrelation coefficient = - 0.63, p = 0.01) This correlation was strong in lower LICs and progressively decreased with upper LIC values. Thus a significant discrepancy was observed between median values of two MRI technologies (p = 0.0005) with T2* tending to underestimate iron overload especially in those with very high LIC identified by R2. The lack of concordance of T2* and R2 especially in those with very high reading on R2 suggest the potential errors in interpretations that can occur in "non-expert centres"; which are likely to lead to errors in clinical judgement on the intensity of chelation therapy needed.


Subject(s)
Iron Overload , beta-Thalassemia , Humans , Iron , Iron Overload/diagnostic imaging , Liver/diagnostic imaging , Magnetic Resonance Imaging , beta-Thalassemia/diagnostic imaging