Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J R Soc Interface ; 21(214): 20230745, 2024 May.
Article in English | MEDLINE | ID: mdl-38745460

ABSTRACT

Migratory songbirds may navigate by extracting positional information from the geomagnetic field, potentially with a magnetic-particle-based receptor. Previous studies assessed this hypothesis experimentally by exposing birds to a strong but brief magnetic pulse aimed at remagnetizing the particles and evoking an altered behaviour. Critically, such studies were not ideally designed because they lacked an adequate sham treatment controlling for the induced electric field that is fundamentally associated with a magnetic pulse. Consequently, we designed a sham-controlled magnetic-pulse experiment, with sham and treatment pulse producing a similar induced electric field, while limiting the sham magnetic field to a value that is deemed insufficient to remagnetize particles. We tested this novel approach by pulsing more than 250 wild, migrating European robins (Erithacus rubecula) during two autumn seasons. After pulsing them, five traits of free-flight migratory behaviour were observed, but no effect of the pulse could be found. Notably, one of the traits, the migratory motivation of adults, was significantly affected in only one of the two study years. Considering the problem of reproducing experiments with wild animals, we recommend a multi-year approach encompassing large sample size, blinded design and built-in sham control to obtain future insights into the role of magnetic-particle-based magnetoreception in bird navigation.


Subject(s)
Animal Migration , Songbirds , Animals , Songbirds/physiology , Animal Migration/physiology , Magnetic Fields , Flight, Animal/physiology
2.
Nat Commun ; 15(1): 2802, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38555281

ABSTRACT

With the huge progress in micro-electronics and artificial intelligence, the ultrasound probe has become the bottleneck in further adoption of ultrasound beyond the clinical setting (e.g. home and monitoring applications). Today, ultrasound transducers have a small aperture, are bulky, contain lead and are expensive to fabricate. Furthermore, they are rigid, which limits their integration into flexible skin patches. New ways to fabricate flexible ultrasound patches have therefore attracted much attention recently. First prototypes typically use the same lead-containing piezo-electric materials, and are made using micro-assembly of rigid active components on plastic or rubber-like substrates. We present an ultrasound transducer-on-foil technology based on thermal embossing of a piezoelectric polymer. High-quality two-dimensional ultrasound images of a tissue mimicking phantom are obtained. Mechanical flexibility and effective area scalability of the transducer are demonstrated by functional integration into an endoscope probe with a small radius of 3 mm and a large area (91.2×14 mm2) non-invasive blood pressure sensor.


Subject(s)
Artificial Intelligence , Electronics , Ultrasonography , Phantoms, Imaging , Electricity , Transducers , Equipment Design
3.
Nat Electron ; 2(12): 606-611, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31872176

ABSTRACT

Capacitive touchscreens are increasingly widespread, featuring in mobile phones and tablets, as well as everyday objects such as cars and home appliances. As a result, the interfaces are uniquely placed to provide a means of communication in the era of the Internet of Everything. Here we show that commercial touchscreens can be used as reader interfaces for capacitive coupled data transfer. The transfer of data to the touchscreen is achieved using a 12-bit thin-film capacitive radio frequency identification tag powered by a thin-film battery or a thin-film photovoltaic cell that converts light from the screen. The thin-film integrated circuit has a 0.8 cm2 on-chip monolithic antenna, employs 439 transistors, and dissipates only 31 nW of power at a supply voltage of 600 mV. The chip has an asynchronous data rate of up to 36 bps, which is limited by the touchscreen readout electronics.

SELECTION OF CITATIONS
SEARCH DETAIL
...