Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 61(5): B246-B254, 2022 Feb 10.
Article in English | MEDLINE | ID: mdl-35201146

ABSTRACT

We propose a simultaneous imaging technique of both sound propagations and spatial distribution of acoustic frequencies. We experimentally demonstrated the proposed technique for the acoustic waves of frequencies 39,500 and 40,500 Hz, which have close sound pressure. The sounds were recorded at the framerate of 100,000 fps by parallel phase-shifting digital holography. To obtain the distribution of the acoustic frequencies, the short-time Fourier transform analysis was applied. The simultaneous imaging was carried out by assigning the frequencies and the pixel values of the phase-difference images to the components of HSL color space. The images obtained by the proposed technique represent the frequencies with the hue in addition to the sound propagations with the luminance. We succeeded in imaging the spatiotemporal evolution of the spatial frequencies of the sounds.

2.
Phys Med ; 86: 98-105, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34082183

ABSTRACT

PURPOSE: Equipment refurbishment was performed to remove the beam-hardening filter (BHF) from the CyberKnife system (CK). This study aimed to confirm the change in the beam characteristics between the conventional CK (present-BHF CK) and CK after the BHF was removed (absent-BHF CK) and evaluate the impact of BHF removal on the beam quality correction factors kQ. METHODS: The experimental measurements of the beam characteristics of the present- and absent-BHF CKs were compared. The CKs were modeled using Monte Carlo simulations (MCs). The energy fluence spectra were calculated using MCs. Finally, kQ were estimated by combining the MC results and analytic calculations based on the TRS-398 and TRS-483 approaches. RESULTS: All gamma values for percent depth doses and beam profiles between each CK were less than 0.5 following the 3%/1 mm criteria. The percentage differences for tissue-phantom ratios at depths of 20 and 10 cm and percentage depth doses at 10 cm between each CK were -1.20% and -0.97%, respectively. The MC results demonstrated that the photon energy fluence spectrum of the absent-BHF CK was softer than that of the present-BHF CK. The kQ values for the absent-BHF CK were in agreement within 0.02% with those for the present-BHF CK. CONCLUSIONS: The photon energy fluence spectrum was softened by the removal of BHF. However, no remarkable impact was observed for the measured beam characteristics and kQ. Therefore, the previous findings of the kQ values for the present-BHF CK can be directly used for the absent-BHF CK.


Subject(s)
Algorithms , Radiotherapy Planning, Computer-Assisted , Monte Carlo Method , Photons , Radiometry
3.
Appl Opt ; 60(10): B49-B58, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33798136

ABSTRACT

Sound is an important invisible physical phenomenon that needs to be explained in several physical and biological processes, along with visual phenomena. For this purpose, multiparameter digital holography (DH) has been proposed to visualize both features simultaneously due to the phase and amplitude reconstruction properties of DH. In this paper, we present a brief review on sound field imaging techniques with special focus on the multiparameter imaging capability of DH for visualizing sound and visual features. The basic theory and several experimental results with very high-speed recordings are also presented to demonstrate sound field imaging for the audible range as well as in the ultrasound range.

4.
Appl Opt ; 60(4): A179-A187, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33690368

ABSTRACT

Sound field imaging techniques have been found very useful for acoustic designs. Building on this idea, innovative techniques are needed and presented in this paper, where we report on developed imaging of the sound field radiated from speakers by parallel phase-shifting digital holography. We adopted an ultrasonic wave radiated from a speaker for an object. The phase distribution of the light wave was modulated by the sound field radiated from the speaker. The modulated phase distribution was recorded in the form of multiplexed phase-shifted holograms at the frame rate of 100,000 fps. A 40,000 Hz sound field radiated from a speaker is used as an observation target. Our proposed method can implement the imaging of the sound field successfully. Also, in order to demonstrate the digital refocusing capability of digital holography, we set two speakers, whose difference in depth positions was 6.6 cm, as a long-depth object. We demonstrated the digital refocusing on the two speakers along with the capability of measuring the positions of the objects. Furthermore, we succeeded in imaging of 40,000 Hz and 41,000 Hz sound fields radiated from the two speakers. The presented experimental results showed that parallel phase-shifting digital holography is very useful and suitable for sound field imaging.

SELECTION OF CITATIONS
SEARCH DETAIL