Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Int J Cardiol Heart Vasc ; 50: 101325, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38419611

ABSTRACT

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods: A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results: For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions: PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.

2.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37942843

ABSTRACT

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Pulmonary Veins , Animals , Humans , Male , Female , Temperature , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Rate , Esophageal Fistula/diagnosis , Esophageal Fistula/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome
3.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37589146

ABSTRACT

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Subject(s)
Catheter Ablation , Pulmonary Veins , Humans , Middle Aged , Aged , Infant , Pulmonary Veins/surgery , Prospective Studies , Catheter Ablation/adverse effects , Temperature
4.
Pediatr Cardiol ; 44(8): 1847-1855, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37561171

ABSTRACT

Chylothorax is a consequence of a thoracic duct injury that can occur during surgical procedures in patients with congenital heart disease. It is associated with high rates of morbimortality and increased use of clinical and hospital resources. The aim of this study was to evaluate the risk factors, distribution, manifestations, complications, and treatments for chylothorax in patients undergoing cardiac surgery in a tertiary pediatric hospital in southern Brazil. This is a retrospective, quantitative study, in which all medical records (n = 166) of patients with chylothorax after pediatric cardiac surgery between January 2014 and December of 2020 and a matched control group (n = 166) were analyzed. Over the study period, there was an increase in incidence of chylothorax from 4.5% in 2014 to 7.6% in 2020, a trend that has been reported in the literature. After multivariate analysis, the following were identified as risk factors for the diagnosis of chylothorax: genetic syndrome (OR 2.298); prolonged cardiopulmonary bypass time (greater than 120 min) (OR 2.410); fluid overload in the immediate postoperative period (OR 1.110); and SIRS (OR 2.527). Mortality was two times greater (p = 0.021) and there was a higher rate (34.4%) of infection (p < 0.001) in patients who developed chylothorax. In addition, a sensitivity analysis was performed comparing patients with low- and high-output chylothorax (> 20 mL/kg), which confirmed unfavorable outcomes for the latter group. Herein, we show that hemodynamic alterations were important factors for diagnosis. Understanding the risk factors, outcomes, and complications helps early identification and enables the reduction of morbidity and mortality.


Subject(s)
Cardiac Surgical Procedures , Chylothorax , Heart Defects, Congenital , Child , Humans , Chylothorax/epidemiology , Chylothorax/etiology , Retrospective Studies , Cardiac Surgical Procedures/methods , Risk Factors , Postoperative Complications/etiology
5.
Front Cardiovasc Med ; 10: 1217745, 2023.
Article in English | MEDLINE | ID: mdl-37435050

ABSTRACT

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.

6.
Int J Cardiol Heart Vasc ; 40: 101042, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35573650

ABSTRACT

Objectives: We sought to assess the efficacy, safety and short-term clinical outcome of very high-power short-duration (vHP-SD) radiofrequency (RF) catheter ablation for the treatment of idiopathic PVCs originating from the cardiac outflow tract (OT). Background: Power-controlled RF ablation is a widely used technique for the treatment of premature ventricular contractions (PVCs). A novel ablation catheter offers three microelectrodes and six thermocouples at its tip and provides temperature-controlled vHP-SD (90 Watts/4 s,) with the opportunity to switch to moderate-power mode. Methods: In this pilot study, twenty-four consecutive, prospectively enrolled patients underwent PVC ablation utilizing the vHP-SD ablation (study group) and were compared with 24 consecutive patients previously treated with power-controlled ablation (control group). Each group included 12 patients with PVCs originating from the right ventricular OT (RVOT) and 12 patients with PVCs originating from the left ventricular OT (LVOT). The acute endpoint was PVC elimination and was achieved in all patients. Results: In 16/24 (67%) patients (study group) it was achieved by using vHP-SD only. The median RF delivery time was 52 (interquartile range [IQR] 16, 156) seconds (study group) and 350 (IQR 240, 442) seconds (control group, p < 0.0001). No difference was observed regarding procedure duration (p = 0.489) as well as 6-months follow-up (p = 0.712). One (4%, study group) and 2 (8%, control group) severe adverse events occured (p = 0.551). Conclusion: In this study, vHP-SD PVC ablation was similarly effective and safe as compared to conventional power-controlled ablation. The RF time was significantly shorter.

7.
Herz ; 47(1): 31-40, 2022 Feb.
Article in German | MEDLINE | ID: mdl-35006289

ABSTRACT

The new European Society of Cardiology (ESC) guidelines on cardiac pacing and cardiac resynchronization therapy were presented together with the new ESC heart failure guidelines at the ESC congress in September. The new document includes detailed sections on patient evaluation and clinical assessment, implantation, minimizing complications and patient follow-up. The guidelines have been updated and expanded particularly on the approach to reflex syncope, the indications after transcatheter aortic valve implantation (TAVI) and the perioperative management. The indications for cardiac resynchronization therapy (CRT) are now in line with the simultaneously published ESC heart failure guidelines. New physiological forms of stimulation and leadless pacing are now included in the guidelines.


Subject(s)
Cardiac Resynchronization Therapy , Cardiology , Cardiovascular System , Heart Failure , Transcatheter Aortic Valve Replacement , Heart Failure/therapy , Humans , Treatment Outcome
8.
Europace ; 24(6): 921-927, 2022 07 15.
Article in English | MEDLINE | ID: mdl-34907431

ABSTRACT

AIMS: Cryoballoon (CB) based pulmonary vein isolation (PVI) is a widely used technique for treatment of atrial fibrillation (AF); however the ideal energy dosing has not yet been standardized. This was a single-centre randomized clinical trial aiming at assessing the safety, acute efficacy, and clinical outcome of an individualized vs. a fixed CB ablation protocol using the fourth-generation CB (CB4) guided by pulmonary vein (PV) potential recordings and CB temperature. METHODS AND RESULTS: Patients were randomized in a 1:1 fashion to two different dosing protocols: INDI-FREEZE group (individualized protocol): freeze-cycle duration of time to effect plus 90 s or interruption of the freeze-cycle and repositioning CB if a CB temperature of -30°C was not within 40 s. Control group (fixed protocol): freeze-cycle duration of 180 s. No-bonus freeze-cycle was applied in either patient group. The primary endpoint was freedom from atrial tachyarrhythmia at 12 months. Secondary end points included procedural parameters and complications. A total of 100 patients with paroxysmal AF were prospectively enrolled. No difference was seen in the primary endpoint [INDI-FREEZE group: 38/47 (81%) vs. control group: 40/47, (85%), P = 0.583]. The total freezing time was significantly shorter in the INDI-FREEZE group (157 ± 56 s vs. 212 ± 83 s, P < 0.001), while procedure duration (57.9 ± 17.9 min vs. 63.2 ± 20.2 min, P = 0.172) was similar. No differences were seen in the minimum CB and oesophageal temperatures as well as in periprocedural complications. CONCLUSION: Compared to the fixed protocol, the individualized approach provides a similar safety profile and clinical outcome, while reducing the total freezing time.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Freezing , Humans , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
9.
Herzschrittmacherther Elektrophysiol ; 32(4): 460-462, 2021 Dec.
Article in German | MEDLINE | ID: mdl-34661737

ABSTRACT

A 80-year-old female patient with symptomatic atrial tachycardia develops cold sweat and hypotension in the recovery room after pulmonary vein isolation. The procedure included an anterior line and an endo- and epicardial mitral isthmus line. Echocardiography excluded a hemodynamically relevant pericardial effusion. The patient's symptoms deteriorated over time. A rare cause was found.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Hypotension , Pulmonary Veins , Aged, 80 and over , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Echocardiography , Female , Humans , Hypotension/diagnosis , Hypotension/etiology , Pulmonary Veins/surgery , Treatment Outcome
10.
Int J Cardiol Heart Vasc ; 35: 100847, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34381869

ABSTRACT

BACKGROUND: Catheter ablation for atrial fibrillation (AF) treatment provides effective and durable pulmonary vein isolation (PVI) and is associated with encouraging clinical outcome. A novel CF sensing temperature-controlled radiofrequency (RF) ablation catheter allows for very high-power short-duration (vHP-SD, 90 W/4 s) ablation aiming a potentially safer, more effective and faster ablation. We thought to evaluate preliminary safety and efficacy of vHP-SD ablation for PVI utilizing a novel vHP-SD catheter. The data was compared to conventional power-controlled ablation index (AI) guided PVI utilizing conventional contact force (CF) sensing catheters. METHODS AND RESULTS: Fifty-six patients with paroxysmal or persistent AF were prospectively enrolled in this study. Twenty-eight consecutive patients underwent vHP-SD based PVI (vHP-SD group) and were compared to 28 consecutive patients treated with conventional CF-sensing catheters utilizing the AI (control group). All PVs were successfully isolated using vHP-SD. The median RF ablation time for vHP-SD was 338 (IQR 286, 367) seconds vs control 1580 (IQR 1350, 1848) seconds (p < 0.0001), the median procedure duration was vHP-SD 55 (IQR 48-60) minutes vs. control 105 (IQR 92-120) minutes (p < 0.0001). No differences in periprocedural complications were observed. CONCLUSIONS: This preliminary data of the novel vHP-SD ablation mode provides safe and effective PVI. Procedure duration and RF ablation time were substantially shorter in the vHP-SD group in comparison to the control group.

11.
J Cardiovasc Electrophysiol ; 32(6): 1553-1560, 2021 06.
Article in English | MEDLINE | ID: mdl-33760304

ABSTRACT

BACKGROUND: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The novel fourth-generation cryoballoon (CB4) incorporates a 40% shorter distal tip. This design change may translate into an increased rate of PVI real-time signal recording, facilitating an individualized ablation strategy using the time to effect (TTE). METHODS AND RESULTS: Three hundred consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled. The first 150 consecutive patients underwent CB2 based PVI (CB2 group) and the last 150 consecutive patients were treated with the CB4 (CB4 group). A total of 594/594 (100%, CB4) and 589/594 (99.2%, CB2) pulmonary veins (PVs) were successfully isolated utilizing the CB4 and CB2, respectively (p = .283). The real-time PVI visualization rate was 47% (CB4) and 39% (CB2; p = .005) and the mean freeze cycle duration 200 ± 90 s (CB4) and 228 ± 110 s (CB2; p < .001), respectively. The total procedure time did not differ between the groups (CB4: 64 ± 32 min) and (CB2: 62 ± 29 min, p = .370). No differences in periprocedural complications were detected. CONCLUSIONS: A higher rate of real-time electrical PV recordings are seen using the CB4 as compared to CB2, which may facilitate an individualized ablation strategy using the TTE.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
SELECTION OF CITATIONS