1.
PLoS One ; 19(3): e0301032, 2024.
Article in English | MEDLINE | ID: mdl-38547135

ABSTRACT

BACKGROUND: A combined vestibular (VI) and cochlear implant (CI) device, also known as the vestibulocochlear implant (VCI), was previously developed to restore both vestibular and auditory function. A new refined prototype is currently being investigated. This prototype allows for concurrent multichannel vestibular and cochlear stimulation. Although recent studies showed that VCI stimulation enables compensatory eye, body and neck movements, the constraints in these acute study designs prevent them from creating more general statements over time. Moreover, the clinical relevance of potential VI and CI interactions is not yet studied. The VertiGO! Trial aims to investigate the safety and efficacy of prolonged daily motion modulated stimulation with a multichannel VCI prototype. METHODS: A single-center clinical trial will be carried out to evaluate prolonged VCI stimulation, assess general safety and explore interactions between the CI and VI. A single-blind randomized controlled crossover design will be implemented to evaluate the efficacy of three types of stimulation. Furthermore, this study will provide a proof-of-concept for a VI rehabilitation program. A total of minimum eight, with a maximum of 13, participants suffering from bilateral vestibulopathy and severe sensorineural hearing loss in the ear to implant will be included and followed over a five-year period. Efficacy will be evaluated by collecting functional (i.e. image stabilization) and more fundamental (i.e. vestibulo-ocular reflexes, self-motion perception) outcomes. Hearing performance with a VCI and patient-reported outcomes will be included as well. DISCUSSION: The proposed schedule of fitting, stimulation and outcome testing allows for a comprehensive evaluation of the feasibility and long-term safety of a multichannel VCI prototype. This design will give insights into vestibular and hearing performance during VCI stimulation. Results will also provide insights into the expected daily benefit of prolonged VCI stimulation, paving the way for cost-effectiveness analyses and a more comprehensive clinical implementation of vestibulocochlear stimulation in the future. TRIAL REGISTRATION: ClinicalTrials.gov: NCT04918745. Registered 28 April 2021.


Subject(s)
Bilateral Vestibulopathy , Cochlear Implants , Humans , Cochlear Implants/adverse effects , Prospective Studies , Single-Blind Method , Randomized Controlled Trials as Topic , Cross-Over Studies
2.
Eur Arch Otorhinolaryngol ; 281(7): 3433-3441, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38180608

ABSTRACT

PURPOSE:  Vestibular implant electrode positioning close to the afferent nerve fibers is considered to be key for effective and selective electrical stimulation. However, accurate positioning of vestibular implant electrodes inside the semicircular canal ampullae is challenging due to the inability to visualize the target during the surgical procedure. This study investigates the accuracy of a new surgical protocol with real-time fluoroscopy and intraoperative CT imaging, which facilitates electrode positioning during vestibular implant surgery. METHODS:  Single-center case-controlled cohort study with a historic control group at a tertiary referral center. Patients were implanted with a vestibulocochlear implant, using a combination of intraoperative fluoroscopy and cone beam CT imaging. The control group consisted of five patients who were previously implanted with the former implant prototype, without the use of intraoperative imaging. Electrode positioning was analyzed postoperatively with a high-resolution CT scan using 3D slicer software. The result was defined as accurate if the electrode position was within 1.5 mm of the center of the ampulla. RESULTS: With the new imaging protocol, all electrodes could be positioned within a 1.5 mm range of the center of the ampulla. The accuracy was significantly higher in the study group with intraoperative imaging (21/21 electrodes) compared to the control group without intraoperative imaging (10/15 electrodes), (p = 0.008). CONCLUSION:  The combined use of intraoperative fluoroscopy and CT imaging during vestibular implantation can improve the accuracy of electrode positioning. This might lead to better vestibular implant performance.


Subject(s)
Cone-Beam Computed Tomography , Humans , Fluoroscopy/methods , Female , Male , Middle Aged , Aged , Case-Control Studies , Cone-Beam Computed Tomography/methods , Electrodes, Implanted , Adult , Tomography, X-Ray Computed/methods , Surgery, Computer-Assisted/methods
3.
Brain Struct Funct ; 225(9): 2757-2774, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33090274

ABSTRACT

The Locus Coeruleus (LC) and the Substantia Nigra (SN) are small brainstem nuclei that change with aging and may be involved in the development of various neurodegenerative and psychiatric diseases. Magnetization Transfer (MT) MRI has been shown to facilitate LC and the SN visualization, and the observed contrast is assumed to be related to neuromelanin accumulation. Imaging these nuclei may have predictive value for the progression of various diseases, but interpretation of previous studies is hindered by the fact that the precise biological source of the contrast remains unclear, though several hypotheses have been put forward. To inform clinical studies on the possible biological interpretation of the LC- and SN contrast, we examined an agar-based phantom containing samples of natural Sepia melanin and synthetic Cys-Dopa-Melanin and compared this to the in vivo human LC and SN. T1 and T2* maps, MT spectra and relaxation times of the phantom, the LC and the SN were measured, and a two-pool MT model was fitted. Additionally, Bloch simulations and a transient MT experiment were conducted to confirm the findings. Overall, our results indicate that Neuromelanin-MRI contrast in the LC likely results from a lower macromolecular fraction, thus facilitating interpretation of results in clinical populations. We further demonstrate that in older individuals T1 lengthening occurs in the LC.


Subject(s)
Locus Coeruleus/anatomy & histology , Magnetic Resonance Imaging/methods , Melanins/chemistry , Substantia Nigra/anatomy & histology , Adult , Female , Humans , Image Enhancement/methods , Locus Coeruleus/diagnostic imaging , Male , Phantoms, Imaging , Substantia Nigra/diagnostic imaging , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...