Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 72
Filter
1.
MAGMA ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38960988

ABSTRACT

OBJECTIVE: To highlight progress and opportunities of measuring kidney size with MRI, and to inspire research into resolving the remaining methodological gaps and unanswered questions relating to kidney size assessment. MATERIALS AND METHODS: This work is not a comprehensive review of the literature but highlights valuable recent developments of MRI of kidney size. RESULTS: The links between renal (patho)physiology and kidney size are outlined. Common methodological approaches for MRI of kidney size are reviewed. Techniques tailored for renal segmentation and quantification of kidney size are discussed. Frontier applications of kidney size monitoring in preclinical models and human studies are reviewed. Future directions of MRI of kidney size are explored. CONCLUSION: MRI of kidney size matters. It will facilitate a growing range of (pre)clinical applications, and provide a springboard for new insights into renal (patho)physiology. As kidney size can be easily obtained from already established renal MRI protocols without the need for additional scans, this measurement should always accompany diagnostic MRI exams. Reconciling global kidney size changes with alterations in the size of specific renal layers is an important topic for further research. Acute kidney size measurements alone cannot distinguish between changes induced by alterations in the blood or the tubular volume fractions-this distinction requires further research into cartography of the renal blood and the tubular volumes.

3.
PLoS One ; 19(4): e0301132, 2024.
Article in English | MEDLINE | ID: mdl-38626138

ABSTRACT

Magnetic Resonance Imaging (MRI) datasets from epidemiological studies often show a lower prevalence of motion artifacts than what is encountered in clinical practice. These artifacts can be unevenly distributed between subject groups and studies which introduces a bias that needs addressing when augmenting data for machine learning purposes. Since unreconstructed multi-channel k-space data is typically not available for population-based MRI datasets, motion simulations must be performed using signal magnitude data. There is thus a need to systematically evaluate how realistic such magnitude-based simulations are. We performed magnitude-based motion simulations on a dataset (MR-ART) from 148 subjects in which real motion-corrupted reference data was also available. The similarity of real and simulated motion was assessed by using image quality metrics (IQMs) including Coefficient of Joint Variation (CJV), Signal-to-Noise-Ratio (SNR), and Contrast-to-Noise-Ratio (CNR). An additional comparison was made by investigating the decrease in the Dice-Sørensen Coefficient (DSC) of automated segmentations with increasing motion severity. Segmentation of the cerebral cortex was performed with 6 freely available tools: FreeSurfer, BrainSuite, ANTs, SAMSEG, FastSurfer, and SynthSeg+. To better mimic the real subject motion, the original motion simulation within an existing data augmentation framework (TorchIO), was modified. This allowed a non-random motion paradigm and phase encoding direction. The mean difference in CJV/SNR/CNR between the real motion-corrupted images and our modified simulations (0.004±0.054/-0.7±1.8/-0.09±0.55) was lower than that of the original simulations (0.015±0.061/0.2±2.0/-0.29±0.62). Further, the mean difference in the DSC between the real motion-corrupted images was lower for our modified simulations (0.03±0.06) compared to the original simulations (-0.15±0.09). SynthSeg+ showed the highest robustness towards all forms of motion, real and simulated. In conclusion, reasonably realistic synthetic motion artifacts can be induced on a large-scale when only magnitude MR images are available to obtain unbiased data sets for the training of machine learning based models.


Subject(s)
Artifacts , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Motion , Brain/diagnostic imaging , Cerebral Cortex , Image Processing, Computer-Assisted/methods
4.
Magn Reson Med ; 91(6): 2532-2545, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38321592

ABSTRACT

PURPOSE: The increasing incidence of kidney diseases is a global concern, and current biomarkers and treatments are inadequate. Changes in renal tubule luminal volume fraction (TVF) serve as a rapid biomarker for kidney disease and improve understanding of renal (patho)physiology. This study uses the amplitude of the long T2 component as a surrogate for TVF in rats, by applying multiexponential analysis of the T2-driven signal decay to examine micromorphological changes in renal tissue. METHODS: Simulations were conducted to identify a low mean absolute error (MAE) protocol and an accelerated protocol customized for the in vivo study of T2 mapping of the rat kidney at 9.4 T. We then validated our bi-exponential approach in a phantom mimicking the relaxation properties of renal tissue. This was followed by a proof-of-principle demonstration using in vivo data obtained during a transient increase of renal pelvis and tubular pressure. RESULTS: Using the low MAE protocol, our approach achieved an accuracy of MAE < 1% on the mechanical phantom. The T2 mapping protocol customized for in vivo study achieved an accuracy of MAE < 3%. Transiently increasing pressure in the renal pelvis and tubules led to significant changes in TVF in renal compartments: ΔTVFcortex = 4.9%, ΔTVFouter_medulla = 4.5%, and ΔTVFinner_medulla = -14.6%. CONCLUSION: These results demonstrate that our approach is promising for research into quantitative assessment of renal TVF in in vivo applications. Ultimately, these investigations have the potential to help reveal mechanism in acute renal injury that may lead to chronic kidney disease, which will support research into renal disorders.


Subject(s)
Acute Kidney Injury , Renal Insufficiency, Chronic , Rats , Animals , Magnetic Resonance Imaging/methods , Kidney/diagnostic imaging , Kidney Tubules/diagnostic imaging
5.
NMR Biomed ; 37(4): e5075, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38043545

ABSTRACT

Renal pathologies often manifest as alterations in kidney size, providing a valuable avenue for employing dynamic parametric MRI as a means to derive kidney size measurements for the diagnosis, treatment, and monitoring of renal disease. Furthermore, this approach holds significant potential in supporting MRI data-driven preclinical investigations into the intricate mechanisms underlying renal pathophysiology. The integration of deep learning algorithms is crucial in achieving rapid and precise segmentation of the kidney from temporally resolved parametric MRI, facilitating the use of kidney size as a meaningful (pre)clinical biomarker for renal disease. To explore this potential, we employed dynamic parametric T2 mapping of the kidney in rats in conjunction with a custom-tailored deep dilated U-Net (DDU-Net) architecture. The architecture was trained, validated, and tested on manually segmented ground truth kidney data, with benchmarking against an analytical segmentation model and a self-configuring no new U-Net. Subsequently, we applied our approach to in vivo longitudinal MRI data, incorporating interventions that emulate clinically relevant scenarios in rats. Our approach achieved high performance metrics, including a Dice coefficient of 0.98, coefficient of determination of 0.92, and a mean absolute percentage error of 1.1% compared with ground truth. The DDU-Net enabled automated and accurate quantification of acute changes in kidney size, such as aortic occlusion (-8% ± 1%), venous occlusion (5% ± 1%), furosemide administration (2% ± 1%), hypoxemia (-2% ± 1%), and contrast agent-induced acute kidney injury (11% ± 1%). This approach can potentially be instrumental for the development of dynamic parametric MRI-based tools for kidney disorders, offering unparalleled insights into renal pathophysiology.


Subject(s)
Deep Learning , Organophosphorus Compounds , Triazoles , Animals , Rats , Kidney/diagnostic imaging , Algorithms , Magnetic Resonance Imaging , Image Processing, Computer-Assisted
6.
Cancers (Basel) ; 15(8)2023 Apr 14.
Article in English | MEDLINE | ID: mdl-37190232

ABSTRACT

Thermal Magnetic Resonance (ThermalMR) is a theranostic concept that combines diagnostic magnetic resonance imaging (MRI) with targeted thermal therapy in the hyperthermia (HT) range using a radiofrequency (RF) applicator in an integrated system. ThermalMR adds a therapeutic dimension to a diagnostic MRI device. Focused, targeted RF heating of deep-seated brain tumors, accurate non-invasive temperature monitoring and high-resolution MRI are specific requirements of ThermalMR that can be addressed with novel concepts in RF applicator design. This work examines hybrid RF applicator arrays combining loop and self-grounded bow-tie (SGBT) dipole antennas for ThermalMR of brain tumors, at magnetic field strengths of 7.0 T, 9.4 T and 10.5 T. These high-density RF arrays improve the feasible transmission channel count, and provide additional degrees of freedom for RF shimming not afforded by using dipole antennas only, for superior thermal therapy and MRI diagnostics. These improvements are especially relevant for ThermalMR theranostics of deep-seated brain tumors because of the small surface area of the head. ThermalMR RF applicators with the hybrid loop+SGBT dipole design outperformed applicators using dipole-only and loop-only designs, with superior MRI performance and targeted RF heating. Array variants with a horse-shoe configuration covering an arc (270°) around the head avoiding the eyes performed better than designs with 360° coverage, with a 1.3 °C higher temperature rise inside the tumor while sparing healthy tissue. Our EMF and temperature simulations performed on a virtual patient with a clinically realistic intracranial tumor provide a technical foundation for implementation of advanced RF applicators tailored for ThermalMR theranostics of brain tumors.

7.
Theranostics ; 13(4): 1217-1234, 2023.
Article in English | MEDLINE | ID: mdl-36923535

ABSTRACT

Theranostic imaging methods could greatly enhance our understanding of the distribution of CNS-acting drugs in individual patients. Fluorine-19 magnetic resonance imaging (19F MRI) offers the opportunity to localize and quantify fluorinated drugs non-invasively, without modifications and without the application of ionizing or other harmful radiation. Here we investigated siponimod, a sphingosine 1-phosphate (S1P) receptor antagonist indicated for secondary progressive multiple sclerosis (SPMS), to determine the feasibility of in vivo 19F MR imaging of a disease modifying drug. Methods: The 19F MR properties of siponimod were characterized using spectroscopic techniques. Four MRI methods were investigated to determine which was the most sensitive for 19F MR imaging of siponimod under biological conditions. We subsequently administered siponimod orally to 6 mice and acquired 19F MR spectra and images in vivo directly after administration, and in ex vivo tissues. Results: The 19F transverse relaxation time of siponimod was 381 ms when dissolved in dimethyl sulfoxide, and substantially reduced to 5 ms when combined with serum, and to 20 ms in ex vivo liver tissue. Ultrashort echo time (UTE) imaging was determined to be the most sensitive MRI technique for imaging siponimod in a biological context and was used to map the drug in vivo in the stomach and liver. Ex vivo images in the liver and brain showed an inhomogeneous distribution of siponimod in both organs. In the brain, siponimod accumulated predominantly in the cerebrum but not the cerebellum. No secondary 19F signals were detected from metabolites. From a translational perspective, we found that acquisitions done on a 3.0 T clinical MR scanner were 2.75 times more sensitive than acquisitions performed on a preclinical 9.4 T MR setup when taking changes in brain size across species into consideration and using equivalent relative spatial resolution. Conclusion: Siponimod can be imaged non-invasively using 19F UTE MRI in the form administered to MS patients, without modification. This study lays the groundwork for more extensive preclinical and clinical investigations. With the necessary technical development, 19F MRI has the potential to become a powerful theranostic tool for studying the time-course and distribution of CNS-acting drugs within the brain, especially during pathology.


Subject(s)
Fluorine-19 Magnetic Resonance Imaging , Multiple Sclerosis, Chronic Progressive , Multiple Sclerosis , Animals , Mice , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/drug therapy , Multiple Sclerosis/pathology , Pharmaceutical Preparations , Magnetic Resonance Imaging/methods , Sphingosine-1-Phosphate Receptors
8.
Acta Physiol (Oxf) ; 237(2): e13868, 2023 02.
Article in English | MEDLINE | ID: mdl-35993768

ABSTRACT

AIM: Tissue hypoxia is an early key feature of acute kidney injury. Assessment of renal oxygenation using magnetic resonance imaging (MRI) markers T2 and T2 * enables insights into renal pathophysiology. This assessment can be confounded by changes in the blood and tubular volume fractions, occurring upon pathological insults. These changes are mirrored by changes in kidney size (KS). Here, we used dynamic MRI to monitor KS for physiological interpretation of T2 * and T2 changes in acute pathophysiological scenarios. METHODS: KS was determined from T2 *, T2 mapping in rats. Six interventions that acutely alter renal tissue oxygenation were performed directly within the scanner, including interventions that change the blood and/or tubular volume. A biophysical model was used to estimate changes in O2 saturation of hemoglobin from changes in T2 * and KS. RESULTS: Upon aortic occlusion KS decreased; this correlated with a decrease in T2 *, T2 . Upon renal vein occlusion KS increased; this negatively correlated with a decrease in T2 *, T2 . Upon simultaneous occlusion of both vessels KS remained unchanged; there was no correlation with decreased T2 *, T2 . Hypoxemia induced mild reductions in KS and T2 *, T2 . Administration of an X-ray contrast medium induced sustained KS increase, with an initial increase in T2 *, T2 followed by a decrease. Furosemide caused T2 *, T2 elevation and a minor increase in KS. Model calculations yielded physiologically plausible calibration ratios for T2 *. CONCLUSION: Monitoring KS allows physiological interpretation of acute renal oxygenation changes obtained by T2 *, T2 . KS monitoring should accompany MRI-oximetry, for new insights into renal pathophysiology and swift translation into human studies.


Subject(s)
Acute Kidney Injury , Kidney , Rats , Humans , Animals , Magnetic Resonance Imaging/methods , Furosemide/pharmacology , Hypoxia , Acute Kidney Injury/diagnostic imaging , Acute Kidney Injury/pathology , Oxygen
9.
Magn Reson Med ; 87(4): 1952-1970, 2022 04.
Article in English | MEDLINE | ID: mdl-34812528

ABSTRACT

PURPOSE: Low SNR in fluorine-19 (19 F) MRI benefits from cryogenically-cooled transceive surface RF probes (CRPs), but strong B1 inhomogeneities hinder quantification. Rapid acquisition with refocused echoes (RARE) is an SNR-efficient method for MRI of neuroinflammation with perfluorinated compounds but lacks an analytical signal intensity equation to retrospectively correct B1 inhomogeneity. Here, a workflow was proposed and validated to correct and quantify 19 F-MR signals from the inflamed mouse brain using a 19 F-CRP. METHODS: In vivo 19 F-MR images were acquired in a neuroinflammation mouse model with a quadrature 19 F-CRP using an imaging setup including 3D-printed components to acquire co-localized anatomical and 19 F images. Model-based corrections were validated on a uniform 19 F phantom and in the neuroinflammatory model. Corrected 19 F-MR images were benchmarked against reference images and overlaid on in vivo 1 H-MR images. Computed concentration uncertainty maps using Monte Carlo simulations served as a measure of performance of the B1 corrections. RESULTS: Our study reports on the first quantitative in vivo 19 F-MR images of an inflamed mouse brain using a 19 F-CRP, including in vivo T1 calculations for 19 F-nanoparticles during pathology and B1 corrections for 19 F-signal quantification. Model-based corrections markedly improved 19 F-signal quantification from errors > 50% to < 10% in a uniform phantom (p < 0.001). Concentration uncertainty maps ex vivo and in vivo yielded uncertainties that were generally < 25%. Monte Carlo simulations prescribed SNR ≥ 10.1 to reduce uncertainties < 10%, and SNR ≥ 4.25 to achieve uncertainties < 25%. CONCLUSION: Our model-based correction method facilitated 19 F signal quantification in the inflamed mouse brain when using the SNR-boosting 19 F-CRP technology, paving the way for future low-SNR 19 F-MRI applications in vivo.


Subject(s)
Magnetic Resonance Imaging , Neuroinflammatory Diseases , Animals , Magnetic Resonance Imaging/methods , Mice , Phantoms, Imaging , Radio Waves , Retrospective Studies
10.
ACS Sens ; 6(11): 3948-3956, 2021 11 26.
Article in English | MEDLINE | ID: mdl-34666481

ABSTRACT

Fluorine (19F) magnetic resonance imaging (MRI) is severely limited by a low signal-to noise ratio (SNR), and tapping it for 19F drug detection in vivo still poses a significant challenge. However, it bears the potential for label-free theranostic imaging. Recently, we detected the fluorinated dihydroorotate dehydrogenase (DHODH) inhibitor teriflunomide (TF) noninvasively in an animal model of multiple sclerosis (MS) using 19F MR spectroscopy (MRS). In the present study, we probed distinct modifications to the CF3 group of TF to improve its SNR. This revealed SF5 as a superior alternative to the CF3 group. The value of the SF5 bioisostere as a 19F MRI reporter group within a biological or pharmacological context is by far underexplored. Here, we compared the biological and pharmacological activities of different TF derivatives and their 19F MR properties (chemical shift and relaxation times). The 19F MR SNR efficiency of three MRI methods revealed that SF5-substituted TF has the highest 19F MR SNR efficiency in combination with an ultrashort echo-time (UTE) MRI method. Chemical modifications did not reduce pharmacological or biological activity as shown in the in vitro dihydroorotate dehydrogenase enzyme and T cell proliferation assays. Instead, SF5-substituted TF showed an improved capacity to inhibit T cell proliferation, indicating better anti-inflammatory activity and its suitability as a viable bioisostere in this context. This study proposes SF5 as a novel superior 19F MR reporter group for the MS drug teriflunomide.


Subject(s)
Crotonates , Dihydroorotate Dehydrogenase , Animals , Hydroxybutyrates , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Nitriles , Toluidines
11.
Quant Imaging Med Surg ; 11(7): 3098-3119, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34249638

ABSTRACT

BACKGROUND: The use of rigid multi-exponential models (with a priori predefined numbers of components) is common practice for diffusion-weighted MRI (DWI) analysis of the kidney. This approach may not accurately reflect renal microstructure, as the data are forced to conform to the a priori assumptions of simplified models. This work examines the feasibility of less constrained, data-driven non-negative least squares (NNLS) continuum modelling for DWI of the kidney tubule system in simulations that include emulations of pathophysiological conditions. METHODS: Non-linear least squares (LS) fitting was used as reference for the simulations. For performance assessment, a threshold of 5% or 10% for the mean absolute percentage error (MAPE) of NNLS and LS results was used. As ground truth, a tri-exponential model using defined volume fractions and diffusion coefficients for each renal compartment (tubule system: Dtubules , ftubules ; renal tissue: Dtissue , ftissue ; renal blood: Dblood , fblood ;) was applied. The impact of: (I) signal-to-noise ratio (SNR) =40-1,000, (II) number of b-values (n=10-50), (III) diffusion weighting (b-rangesmall =0-800 up to b-rangelarge =0-2,180 s/mm2), and (IV) fixation of the diffusion coefficients Dtissue and Dblood was examined. NNLS was evaluated for baseline and pathophysiological conditions, namely increased tubular volume fraction (ITV) and renal fibrosis (10%: grade I, mild) and 30% (grade II, moderate). RESULTS: NNLS showed the same high degree of reliability as the non-linear LS. MAPE of the tubular volume fraction (ftubules ) decreased with increasing SNR. Increasing the number of b-values was beneficial for ftubules precision. Using the b-rangelarge led to a decrease in MAPE ftubules compared to b-rangesmall. The use of a medium b-value range of b=0-1,380 s/mm2 improved ftubules precision, and further bmax increases beyond this range yielded diminishing improvements. Fixing Dblood and Dtissue significantly reduced MAPE ftubules and provided near perfect distinction between baseline and ITV conditions. Without constraining the number of renal compartments in advance, NNLS was able to detect the (fourth) fibrotic compartment, to differentiate it from the other three diffusion components, and to distinguish between 10% vs. 30% fibrosis. CONCLUSIONS: This work demonstrates the feasibility of NNLS modelling for DWI of the kidney tubule system and shows its potential for examining diffusion compartments associated with renal pathophysiology including ITV fraction and different degrees of fibrosis.

12.
Acta Physiol (Oxf) ; 233(2): e13701, 2021 10.
Article in English | MEDLINE | ID: mdl-34089569

ABSTRACT

AIM: Kidney diseases constitute a major health challenge, which requires noninvasive imaging to complement conventional approaches to diagnosis and monitoring. Several renal pathologies are associated with changes in kidney size, offering an opportunity for magnetic resonance imaging (MRI) biomarkers of disease. This work uses dynamic MRI and an automated bean-shaped model (ABSM) for longitudinal quantification of pathophysiologically relevant changes in kidney size. METHODS: A geometry-based ABSM was developed for kidney size measurements in rats using parametric MRI (T2 , T2 * mapping). The ABSM approach was applied to longitudinal renal size quantification using occlusion of the (a) suprarenal aorta or (b) the renal vein, (c) increase in renal pelvis and intratubular pressure and (d) injection of an X-ray contrast medium into the thoracic aorta to induce pathophysiologically relevant changes in kidney size. RESULTS: The ABSM yielded renal size measurements with accuracy and precision equivalent to the manual segmentation, with >70-fold time savings. The automated method could detect a ~7% reduction (aortic occlusion) and a ~5%, a ~2% and a ~6% increase in kidney size (venous occlusion, pelvis and intratubular pressure increase and injection of X-ray contrast medium, respectively). These measurements were not affected by reduced image quality following administration of ferumoxytol. CONCLUSION: Dynamic MRI in conjunction with renal segmentation using an ABSM supports longitudinal quantification of changes in kidney size in pathophysiologically relevant experimental setups mimicking realistic clinical scenarios. This can potentially be instrumental for developing MRI-based diagnostic tools for various kidney disorders and for gaining new insight into mechanisms of renal pathophysiology.


Subject(s)
Magnetic Resonance Imaging , Vascular Diseases , Animals , Kidney/diagnostic imaging , Rats
13.
Magn Reson Med ; 86(3): 1383-1402, 2021 09.
Article in English | MEDLINE | ID: mdl-33951214

ABSTRACT

PURPOSE: The characteristic MRI features of multiple sclerosis (MS) lesions make it conceptually appealing to pursue parametric mapping techniques that support simultaneous generation of quantitative maps of 2 or more MR contrast mechanisms. We present a modular rapid acquisition with relaxation enhancement (RARE)-EPI hybrid that facilitates simultaneous T2 and T2∗ mapping (2in1-RARE-EPI). METHODS: In 2in1-RARE-EPI the first echoes in the echo train are acquired with a RARE module, later echoes are acquired with an EPI module. To define the fraction of echoes covered by the RARE and EPI module, an error analysis of T2 and T2∗ was conducted with Monte Carlo simulations. Radial k-space (under)sampling was implemented for acceleration (R = 2). The feasibility of 2in1-RARE-EPI for simultaneous T2 and T2∗ mapping was examined in a phantom study mimicking T2 and T2∗ relaxation times of the brain. For validation, 2in1-RARE-EPI was benchmarked versus multi spin-echo (MSE) and multi gradient-echo (MGRE) techniques. The clinical applicability of 2in1-RARE-EPI was demonstrated in healthy subjects and MS patients. RESULTS: There was a good agreement between T2 / T2∗ values derived from 2in1-RARE-EPI and T2 / T2∗ reference values obtained from MSE and MGRE in both phantoms and healthy subjects. In patients, MS lesions in T2 and T2∗ maps deduced from 2in1-RARE-EPI could be just as clearly delineated as in reference maps calculated from MSE/MGRE. CONCLUSION: This work demonstrates the feasibility of radially (under)sampled 2in1-RARE-EPI for simultaneous T2 and T2∗ mapping in MS patients.


Subject(s)
Multiple Sclerosis , Brain/diagnostic imaging , Humans , Magnetic Resonance Imaging , Multiple Sclerosis/diagnostic imaging , Phantoms, Imaging , Reference Values
15.
J Vis Exp ; (168)2021 02 19.
Article in English | MEDLINE | ID: mdl-33682856

ABSTRACT

The overall goal of this article is to demonstrate a state-of-the-art ultrahigh field (UHF) magnetic resonance (MR) protocol of the brain at 7.0 Tesla in multiple sclerosis (MS) patients. MS is a chronic inflammatory, demyelinating, neurodegenerative disease that is characterized by white and gray matter lesions. Detection of spatially and temporally disseminated T2-hyperintense lesions by the use of MRI at 1.5 T and 3 T represents a crucial diagnostic tool in clinical practice to establish accurate diagnosis of MS based on the current version of the 2017 McDonald criteria. However, the differentiation of MS lesions from brain white matter lesions of other origins can sometimes be challenging due to their resembling morphology at lower magnetic field strengths (typically 3 T). Ultrahigh field MR (UHF-MR) benefits from increased signal-to-noise ratio and enhanced spatial resolution, both key to superior imaging for more accurate and definitive diagnoses of subtle lesions. Hence, MRI at 7.0 T has shown encouraging results to overcome the challenges of MS differential diagnosis by providing MS-specific neuroimaging markers (e.g., central vein sign, hypointense rim structures and differentiation of MS grey matter lesions). These markers and others can be identified by other MR contrasts other than T1 and T2 (T2*, phase, diffusion) and substantially improve the differentiation of MS lesions from those occurring in other neuroinflammatory conditions such as neuromyelitis optica and Susac syndrome. In this article, we describe our current technical approach to study cerebral white and grey matter lesions in MS patients at 7.0 T using different MR acquisition methods. The up-to-date protocol includes the preparation of the MR setup including the radio-frequency coils customized for UHF-MR, standardized screening, safety and interview procedures with MS patients, patient positioning in the MR scanner and acquisition of dedicated brain scans tailored for examining MS.


Subject(s)
Magnetic Resonance Imaging , Multiple Sclerosis/diagnostic imaging , Cerebral Cortex/diagnostic imaging , Cerebral Cortex/pathology , Humans , Image Processing, Computer-Assisted , Multiple Sclerosis/pathology , Neuroimaging , Software , White Matter/diagnostic imaging , White Matter/pathology
16.
Methods Mol Biol ; 2216: 3-23, 2021.
Article in English | MEDLINE | ID: mdl-33475991

ABSTRACT

Renal MRI holds incredible promise for making a quantum leap in improving diagnosis and care of patients with a multitude of diseases, by moving beyond the limitations and restrictions of current routine clinical practice. Clinical and preclinical renal MRI is advancing with ever increasing rapidity, and yet, aside from a few examples of renal MRI in routine use, it is still not good enough. Several roadblocks are still delaying the pace of progress, particularly inefficient education of renal MR researchers, and lack of harmonization of approaches that limits the sharing of results among multiple research groups.Here we aim to address these limitations for preclinical renal MRI (predominantly in small animals), by providing a comprehensive collection of more than 40 publications that will serve as a foundational resource for preclinical renal MRI studies. This includes chapters describing the fundamental principles underlying a variety of renal MRI methods, step-by-step protocols for executing renal MRI studies, and detailed guides for data analysis. This collection will serve as a crucial part of a roadmap toward conducting renal MRI studies in a robust and reproducible way, that will promote the standardization and sharing of data.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers.


Subject(s)
Biomarkers/analysis , Kidney Diseases/classification , Kidney Diseases/pathology , Kidney/physiopathology , Magnetic Resonance Imaging/methods , Practice Guidelines as Topic/standards , Disease Progression , Humans , Kidney Diseases/therapy , Reproducibility of Results
17.
Methods Mol Biol ; 2216: 75-85, 2021.
Article in English | MEDLINE | ID: mdl-33475995

ABSTRACT

Here we describe a simple and inexpensive protocol for preparing ex vivo rodent phantoms for use in MR imaging studies. The experimental animals are perfused and fixed with formaldehyde, and then wrapped with gauze and sealed with liquid latex. This yields a phantom that preserves all organs in situ, and which avoids the need to keep fixed animals and organs in containers that have dimensions very different from living animals. This is especially important for loading in MR detectors, and specifically the RF coils, they are usually used with. The phantom can be safely stored and conveniently reused, and can provide MR scientists with a realistic phantom with which to establish protocols in preparation for preclinical in vivo studies-for renal, brain, and body imaging. The phantom also serves as an ideal teaching tool, for trainees learning how to perform preclinical MRI investigations of the kidney and other target organs, while avoiding the need for handling living animals, and reducing the total number of animals required.This protocol chapter is part of the PARENCHIMA initiative "MRI Biomarkers for CKD " (CA16103), a community-driven Action of the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers.


Subject(s)
Biomarkers/analysis , Brain/physiology , Image Processing, Computer-Assisted/methods , Kidney/physiology , Magnetic Resonance Imaging/methods , Monitoring, Physiologic/methods , Phantoms, Imaging , Animals , Mice , Rats , Software
18.
Methods Mol Biol ; 2216: 279-299, 2021.
Article in English | MEDLINE | ID: mdl-33476007

ABSTRACT

Kidney-associated pathologies would greatly benefit from noninvasive and robust methods that can objectively quantify changes in renal function. In the past years there has been a growing incentive to develop new applications for fluorine (19F) MRI in biomedical research to study functional changes during disease states. 19F MRI represents an instrumental tool for the quantification of exogenous 19F substances in vivo. One of the major benefits of 19F MRI is that fluorine in its organic form is absent in eukaryotic cells. Therefore, the introduction of exogenous 19F signals in vivo will yield background-free images, thus providing highly selective detection with absolute specificity in vivo. Here we introduce the concept of 19F MRI, describe existing challenges, especially those pertaining to signal sensitivity, and give an overview of preclinical applications to illustrate the utility and applicability of this technique for measuring renal function in animal models.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This introduction chapter is complemented by two separate chapters describing the experimental procedure and data analysis.


Subject(s)
Biomarkers/analysis , Fluorine-19 Magnetic Resonance Imaging/methods , Fluorine/analysis , Image Processing, Computer-Assisted/methods , Kidney/physiology , Monitoring, Physiologic/methods , Animals , Humans , Software
19.
Methods Mol Biol ; 2216: 495-507, 2021.
Article in English | MEDLINE | ID: mdl-33476020

ABSTRACT

Inflammation is one underlying contributing factor in the pathology of acute and chronic kidney disorders. Phagocytes such as monocytes, neutrophils and dendritic cells are considered to play a deleterious role in the progression of kidney disease but may also contribute to organ homeostasis. The kidney is a target of life-threatening autoimmune disorders such as the antineutrophil cytoplasmic antibody (ANCA)-associated vasculitides (AAV). Neutrophils and monocytes express ANCA antigens and play an important role in the pathogenesis of AAV. Noninvasive in vivo methods that can quantify the distribution of inflammatory cells in the kidney as well as other organs in vivo would be vital to identify the causality and significance of inflammation during disease progression. Here we describe an noninvasive technique to study renal inflammation in rodents in vivo using fluorine (19F) MRI. In this protocol we chose a murine ANCA-AAV model of renal inflammation and made use of nanoparticles prepared from perfluoro-5-crown-15-ether (PFCE) for renal 19F MRI.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This experimental protocol chapter is complemented by two separate chapters describing the basic concept and data analysis.


Subject(s)
Fluorine-19 Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods , Kidney/immunology , Kidney/physiology , Monitoring, Physiologic/methods , Animals , Mice , Mice, Inbred C57BL , Mice, Knockout , Peroxidase/physiology , Software
20.
Methods Mol Biol ; 2216: 711-722, 2021.
Article in English | MEDLINE | ID: mdl-33476033

ABSTRACT

Fluorine-19 MRI shows great promise for a wide range of applications including renal imaging, yet the typically low signal-to-noise ratios and sparse signal distribution necessitate a thorough data preparation.This chapter describes a general data preparation workflow for fluorine MRI experiments. The main processing steps are: (1) estimation of noise level, (2) correction of noise-induced bias and (3) background subtraction. The protocol is supplemented by an example script and toolbox available online.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concept and experimental procedure.


Subject(s)
Biomarkers/analysis , Fluorine-19 Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Kidney/physiology , Signal-To-Noise Ratio , Software , Animals , Mice , Monitoring, Physiologic , Rats
SELECTION OF CITATIONS
SEARCH DETAIL
...