Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
Ther Hypothermia Temp Manag ; 13(4): 225-229, 2023 Dec.
Article En | MEDLINE | ID: mdl-37527424

Fever is a recognized protective factor in patients with sepsis, and growing data suggest beneficial effects on outcomes in sepsis with elevated temperature, with a recent pilot randomized controlled trial (RCT) showing lower mortality by warming afebrile sepsis patients in the intensive care unit (ICU). The objective of this prospective single-site RCT was to determine if core warming improves respiratory physiology of mechanically ventilated patients with coronavirus disease 2019 (COVID-19), allowing earlier weaning from ventilation, and greater overall survival. A total of 19 patients with mean age of 60.5 (±12.5) years, 37% female, mean weight 95.1 (±18.6) kg, and mean body mass index 34.5 (±5.9) kg/m2 with COVID-19 requiring mechanical ventilation were enrolled from September 2020 to February 2022. Patients were randomized 1:1 to standard of care or to receive core warming for 72 hours through an esophageal heat exchanger commonly utilized in critical care and surgical patients. The maximum target temperature was 39.8°C. A total of 10 patients received usual care and 9 patients received esophageal core warming. After 72 hours of warming, the ratio of arterial oxygen partial pressure to fractional inspired oxygen (PaO2/FiO2) ratios were 197 (±32) and 134 (±13.4), cycle thresholds were 30.8 (±6.4) and 31.4 (±3.2), ICU mortalities were 40% and 44%, 30-day mortalities were 30% and 22%, and mean 30-day ventilator-free days were 11.9 (±12.6) and 6.8 (±10.2) for standard of care and warmed patients, respectively (p = NS). This pilot study suggests that core warming of patients with COVID-19 undergoing mechanical ventilation is feasible and appears safe. Optimizing time to achieve febrile-range temperature may require a multimodal temperature management strategy to further evaluate effects on outcome. ClinicalTrials.gov Identifier: NCT04494867.


COVID-19 , Hypothermia, Induced , Sepsis , Female , Humans , Middle Aged , Male , COVID-19/therapy , Respiration, Artificial , Pilot Projects , Oxygen
2.
Disaster Med Public Health Prep ; : 1-8, 2021 Jun 08.
Article En | MEDLINE | ID: mdl-34099097

In March 2020, at the onset of the coronavirus disease 2019 (COVID-19) pandemic in the United States, the Southern California Extracorporeal Membrane Oxygenation (ECMO) Consortium was formed. The consortium included physicians and coordinators from the 4 ECMO centers in San Diego County. Guidelines were created to ensure that ECMO was delivered equitably and in a resource effective manner across the county during the pandemic. A biomedical ethicist reviewed the guidelines to ensure ECMO use would provide maximal community benefit of this limited resource. The San Diego County Health and Human Services Agency further incorporated the guidelines into its plans for the allocation of scarce resources. The consortium held weekly video conferences to review countywide ECMO capacity (including census and staffing), share data, and discuss clinical practices and difficult cases. Equipment exchanges between ECMO centers maximized regional capacity. From March 1 to November 30, 2020, consortium participants placed 97 patients on ECMO. No eligible patients were denied ECMO due to lack of resources or capacity. The Southern California ECMO Consortium may serve as a model for other communities seeking to optimize ECMO resources during the current COVID-19 or future pandemics.

3.
Infect Dis Ther ; 10(3): 1323-1330, 2021 Sep.
Article En | MEDLINE | ID: mdl-33977506

INTRODUCTION: Despite considerable scientific debate, there have been no prospective clinical studies on the effects of angiotensin II receptor blockers (ARBs) on the course of COVID-19 infection. Losartan is the ARB that was chosen to be tested in this study. METHODS: Patients with COVID-19 and mild hypoxia (receipt of ≤ 3 L/min O2 by nasal cannula) admitted to three hospitals were randomized in a 1:1 ratio within 72 h of SARS-CoV-2 nucleic acid testing confirmation to prospectively receive standard of care (SOC) alone or SOC plus losartan 12.5 mg orally every 12 h for 10 days or until hospital discharge, with the option to titrate upward dependent on blood pressure tolerability. Primary composite endpoint was receipt of mechanical ventilation or death before receiving ventilation. Subjects were followed until discharge to home or until an endpoint was met in the hospital. RESULTS: Sixteen subjects received an ARB plus SOC and 15 subjects received SOC alone. The median age was 53 years for both groups. Median time from hospital admission to study enrollment was 2 days (range 1-6) for the ARB group and 2 days (range 1-4) for the SOC group. Mean Charlson comorbidity index was 2 for both groups. One subject in each group achieved the composite endpoint. CONCLUSION: This small prospective randomized open-label study showed no clinically significant impacts of ARB therapy in mildly hypoxemic patients hospitalized with COVID-19 early in the pandemic. A larger prospective randomized placebo-controlled trial would be needed to confirm these findings or capture less pronounced effects and probably should focus on outpatients earlier in disease course. TRIAL REGISTRATION: clinicaltrials.gov; March 27, 2020; NCT04340557.

4.
Respir Care ; 57(4): 646-9, 2012 Apr.
Article En | MEDLINE | ID: mdl-22472502

A 39-year-old man experienced total obstruction of a distal tracheal plastic stent by a tumor mass, preventing effective ventilation and resulting in cardiac arrest. Resuscitation by emergency bedside venoarterial extracorporeal membrane oxygenation (ECMO) permitted time to physically remove the obstructing tumor and reestablish successful ventilation and liberation from ventilatory support. We review several other reported cases of emergency ECMO to resuscitate patients with acute airway obstruction.


Airway Obstruction/therapy , Extracorporeal Membrane Oxygenation , Lung Neoplasms/complications , Osteosarcoma/complications , Tracheal Diseases/therapy , Acute Disease , Adult , Airway Obstruction/etiology , Bronchoscopy , Emergency Medical Services , Heart Arrest/etiology , Humans , Lung Neoplasms/secondary , Male , Osteosarcoma/secondary , Tracheal Diseases/etiology
6.
Respir Care ; 50(8): 1046-9, 2005 Aug.
Article En | MEDLINE | ID: mdl-16225709

BACKGROUND: There is little published information on the role of respiratory therapists in the process of withdrawal of mechanical ventilatory support. METHODS: We surveyed practicing respiratory therapists at 6 acute-care hospitals in a large urban area and asked about particular concerns and attitudes regarding terminal extubation. RESULTS: One hundred nineteen questionnaires were analyzed. The majority of respiratory therapists had participated in terminal extubation, but most were not regular participants in the decision-making process leading to withdrawal. CONCLUSIONS: Practicing respiratory therapists expressed a desire for a role in the decision-making process, education regarding terminal care, and more definitive orders for terminal extubation.


Allied Health Personnel/psychology , Attitude of Health Personnel , Respiratory Therapy , Terminal Care , Ventilators, Mechanical , California , Data Collection , Humans , Life Support Care , Palliative Care , Surveys and Questionnaires , Withholding Treatment
7.
Am J Infect Control ; 33(8): 483-5, 2005 Oct.
Article En | MEDLINE | ID: mdl-16216665

Oral suction devices may be fomites for nosocomial infections. This study was designed to evaluate the rate of contamination of Yankauer suction catheters. Among the 20 catheters tested, 16 (80%) yielded cultures for pathogens. Seven (35%) were colonized with multiple pathogens. Among the organisms encountered included methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococci (VRE). These devices should be handled and stored with appropriate care.


Bacteria/isolation & purification , Catheterization , Equipment Contamination , Fomites , Intensive Care Units , Bacteria/classification , Enterococcus/classification , Enterococcus/isolation & purification , Hospitals , Humans , Methicillin Resistance , Staphylococcus aureus/classification , Staphylococcus aureus/isolation & purification , Vancomycin Resistance
8.
Respir Care ; 50(3): 354-60, 2005 Mar.
Article En | MEDLINE | ID: mdl-15737245

BACKGROUND: Helium-oxygen (heliox) mixtures are being used more frequently with mechanical ventilators. Newer ventilators continue to be developed that have not yet been evaluated for safety and efficacy of heliox delivery. We studied the performance of 2 previously untested ventilators (Servo-i and Inspiration) during heliox administration. METHODS: We measured tidal volume (V(T)) delivery, gas blending, gas analyzing, and pressure stability in the presence of heliox. A heliox (80% helium/20% oxygen) tank was attached to the 50-psi air inlet. We compared the set V(T) (ie, set on the ventilator) and the exhaled V(T) (measured by the ventilator) to the delivered V(T) (measured with a lung model). Pressure measurements were also evaluated. We also compared the ventilator-setting fraction of inspired oxygen (F(IO(2))) to the F(IO(2)) measured by the ventilator and the F(IO(2)) measured with a supplemental oxygen analyzer. RESULTS: Heliox significantly affected both the exhaled V(T) measurement and the actual delivered V(T) (p < 0.001) with both the Servo-i and the Inspiration. Neither peak inspiratory pressure (in the pressure-controlled ventilation mode) nor positive end-expiratory pressure were adversely affected by heliox with either ventilator. Introducing heliox into the gas-blending systems caused only a small error in F(IO2) delivery and monitoring. CONCLUSIONS: Both Ventilators cycled consistently with heliox mixtures. In most cases, actual delivered V(T) can be reliably calculated if the F(IO2) and the set V(T) or the measured exhaled V(T) is known. With the Servo-i, at high helium concentrations the exhaled V(T) measurement was unreliable and caused a high-priority alarm condition that couldn't be disabled. A supplemental oxygen analyzer is not necessary with either device for heliox applications.


Helium/administration & dosage , Oxygen/administration & dosage , Respiration, Artificial/instrumentation , Ventilators, Mechanical , Administration, Inhalation , Equipment Design , Models, Biological , Oxygen/analysis , Positive-Pressure Respiration/instrumentation , Tidal Volume
...