Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
Eur Heart J Digit Health ; 5(3): 219-228, 2024 May.
Article in English | MEDLINE | ID: mdl-38774374

ABSTRACT

Aims: Permanent pacemaker implantation and left bundle branch block are common complications after transcatheter aortic valve replacement (TAVR) and are associated with impaired prognosis. This study aimed to develop an artificial intelligence (AI) model for predicting conduction disturbances after TAVR using pre-procedural 12-lead electrocardiogram (ECG) images. Methods and results: We collected pre-procedural 12-lead ECGs of patients who underwent TAVR at West China Hospital between March 2016 and March 2022. A hold-out testing set comprising 20% of the sample was randomly selected. We developed an AI model using a convolutional neural network, trained it using five-fold cross-validation and tested it on the hold-out testing cohort. We also developed and validated an enhanced model that included additional clinical features. After applying exclusion criteria, we included 1354 ECGs of 718 patients in the study. The AI model predicted conduction disturbances in the hold-out testing cohort with an area under the curve (AUC) of 0.764, accuracy of 0.743, F1 score of 0.752, sensitivity of 0.876, and specificity of 0.624, based solely on pre-procedural ECG images. The performance was better than the Emory score (AUC = 0.704), as well as the logistic (AUC = 0.574) and XGBoost (AUC = 0.520) models built with previously identified high-risk ECG patterns. After adding clinical features, there was an increase in the overall performance with an AUC of 0.779, accuracy of 0.774, F1 score of 0.776, sensitivity of 0.794, and specificity of 0.752. Conclusion: Artificial intelligence-enhanced ECGs may offer better predictive value than traditionally defined high-risk ECG patterns.

2.
JCI Insight ; 9(4)2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38290007

ABSTRACT

A robust, sterile inflammation underlies myocardial ischemia and reperfusion injury (MIRI). Several subsets of B cells possess the immunoregulatory capacity that limits tissue damage, yet the role of B cells in MIRI remains elusive. Here, we sought to elucidate the contribution of B cells to MIRI by transient ligation of the left anterior descending coronary artery in B cell-depleted or -deficient mice. Following ischemia and reperfusion (I/R), regulatory B cells are rapidly recruited to the heart. B cell-depleted or -deficient mice exhibited exacerbated tissue damage, adverse cardiac remodeling, and an augmented inflammatory response after I/R. Rescue and chimeric experiments indicated that the cardioprotective effect of B cells was not solely dependent on IL-10. Coculture experiments demonstrated that B cells induced neutrophil apoptosis through contact-dependent interactions, subsequently promoting reparative macrophage polarization by facilitating the phagocytosis of neutrophils by macrophages. The in vivo cardioprotective effect of B cells was undetectable in the absence of neutrophils after I/R. Mechanistically, ligand-receptor imputation identified FCER2A as a potential mediator of interactions between B cells and neutrophils. Blocking FCER2A on B cells resulted in a reduction in the percentage of apoptotic neutrophils, contributing to the deterioration of cardiac remodeling. Our findings unveil a potential cardioprotective role of B cells in MIRI through mechanisms involving FCER2A, neutrophils, and macrophages.


Subject(s)
B-Lymphocyte Subsets , Myocardial Reperfusion Injury , Mice , Animals , Neutrophils/physiology , Ventricular Remodeling , Ischemia , Apoptosis
3.
Cardiovasc Ther ; 2023: 6659048, 2023.
Article in English | MEDLINE | ID: mdl-37645544

ABSTRACT

Objective: We aim to conduct a comparison of the safety and effectiveness performance between left bundle branch area pacing (LBBAP) and right ventricular pacing (RVP) regimens for patients with atrioventricular block (AVB). Methods: This observational cohort study included patients who underwent pacemaker implantations with LBBAP or RVP for AVB indications from the 1st of January 2018 to the 18th of November 2021 at West China Hospital. The primary composite outcome included all-cause mortality, lead failure, or heart failure hospitalization (HFH). The secondary outcome included periprocedure complication, cardiac death, or recurrent unexplained syncope. A 1 : 1 propensity score-matched cohort was conducted for left ventricular (LV) function analysis. Results: A total of 903 patients met the inclusion criteria and completed clinical follow-up. After adjusting for the possible confounders, LBBAP was independently associated with a lower risk of the primary outcome (OR 0.48, 95% CI 0.28 to 0.83, p = 0.009), including a lower risk of all-cause mortality and HFH. No significant difference in the secondary outcome was detected between the groups except that LBBAP was independently associated with a lower risk of recurrent unexplained syncope. In the propensity-score matching cohort of echocardiographic analysis, the LV systolic dyssynchrony index was lower in LBBAP compared with that in RVP (5.68 ± 1.92 vs. 6.50 ± 2.28%, p = 0.012). Conclusions: Compared to conventional RVP, LBBAP is a feasible novel pacing model associated with a significant reduction in the primary composite outcome. Moreover, LBBAP significantly reduces the risk of recurrent unexplained syncope and improves LV systolic synchrony. This study is registered with ClinicalTrials.gov NCT05722379.


Subject(s)
Atrioventricular Block , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Heart Ventricles , China , Cohort Studies , Echocardiography
4.
Pacing Clin Electrophysiol ; 46(11): 1366-1369, 2023 11.
Article in English | MEDLINE | ID: mdl-36896741

ABSTRACT

BACKGROUND: We present a case of epicardial pacemaker implantation in a low birth weight newborn using a lumenless active fixation lead. RESULTS: We found that superior pacing parameters can be obtained by implanting a lumenless active fixation lead into the epicardium, but more evidence is needed to support this hypothesis.


Subject(s)
Cardiac Pacing, Artificial , Pacemaker, Artificial , Infant, Newborn , Humans , Pericardium/surgery , Prosthesis Implantation , Electrodes, Implanted
5.
J Cardiovasc Electrophysiol ; 34(3): 718-725, 2023 03.
Article in English | MEDLINE | ID: mdl-36738153

ABSTRACT

INTRODUCTION: Left bundle branch area pacing (LBBAP) is achieved by advancing the lead tip deep in the septum. Most LBBAP implants are performed using the Medtronic SelectSecure™ MRI SecureScan™ Model 3830 featuring a unique 4 Fr fixed helix lumenless design. Details of lead use conditions and long-term reliability have not been reported. This study was designed to quantify the mechanical use conditions for the 3830 lead during and after LBBAP implant, and to evaluate reliability using bench testing and simulation. METHODS: Fifty bradycardia patients with implantation of the 3830 lead for LBBAP were enrolled. Use conditions of lead deployment at implantation were collected and computed tomography (CT) scans were performed at 3-month follow-up. Curvature amplitude along the pacing lead was determined with CT images. Fatigue bending was performed using accelerated testing in a more severe environment than routine clinical use conditions. Conductor fracture rate in a simulated patient population was estimated based on clinical use conditions and fatigue test results. RESULTS: The number of attempts to place the 3830 lead for LBBAP was 2.1 ± 1.3 (range: 1-7) with 13 ± 6 lead rotations at the final attempt. Extreme implant conditions were simulated in bench testing with 5 applications of 20 turns followed by up to 400 million bending cycles. Reliability modeling predicted a 10-year fracture rate of 0.02%. CONCLUSIONS: LBBAP implants require more lead rotations than standard pacing implants and result in unique lead bending. Application of simulated LBBAP use conditions to the 3830 lead in an accelerated in-vitro model does not produce excess conductor fractures. IMAGE-LBBP Study ID of ClinicalTrial.GOV: NCT04119323.


Subject(s)
Pacemaker, Artificial , Humans , Bundle of His , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Reproducibility of Results
6.
J Cardiovasc Electrophysiol ; 33(6): 1244-1254, 2022 06.
Article in English | MEDLINE | ID: mdl-35419908

ABSTRACT

INTRODUCTION: Left bundle branch area pacing (LBBAP) is a novel physiological pacing modality. The relationship between the pacing lead tip location and paced electrocardiographic (ECG) characteristics remains unclear. The objectives are to determine the lead tip location within the interventricular septum (IVS) and assess the location-based ECG QRS duration (QRSd) and left ventricular activation time (LVAT). METHODS: This multicenter study enrolled 50 consecutive bradycardia patients who met pacemaker therapy guidelines and received LBBAP implantation via the trans-ventricular septal approach. After at least 3 months postimplant, 12-lead ECGs and pacing parameters were obtained. Cardiac computed tomography (CT) imaging was performed to assess the LBBAP lead tip distance from the LV blood pool. RESULTS: Among the 50 patients, analyzable CT images were obtained in 42. In 23 of the 42 patients, the lead tips were within 2 mm to the LV blood pool (the LV subendocardial (LVSE) group), 13 between 2 and 4 mm (the Near-LVSE group), and the remaining 6 beyond 4 mm (the Mid-LV septal (Mid-LVS) group). No significant differences in paced QRSd were found among the three groups (LVSE, 107 ± 15 ms; Near-LVSE, 106 ± 13 ms; Mid-LVS, 104 ± 15 ms; p = .87). LVAT in the LVSE (64 ± 7 ms) was significantly shorter than in the Mid-LVS (72 ± 8 ms; p < .05), but not significantly different from that in the Near-LVSE (69 ± 8 ms; p > .05). CONCLUSION: In routine LBBAP practice, paced narrow QRSd and fast LVAT, indicative of physiological pacing, were consistently achieved for lead tip location in the LV subendocardial or near LV subendocardial region.


Subject(s)
Bradycardia , Cardiac Pacing, Artificial , Bradycardia/diagnostic imaging , Bradycardia/therapy , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Heart Conduction System , Humans , Tomography, X-Ray Computed
7.
ESC Heart Fail ; 8(1): 546-554, 2021 02.
Article in English | MEDLINE | ID: mdl-33169538

ABSTRACT

AIMS: This study aims to investigate the current status of biventricular pacemaker and defibrillator implantation in chronic heart failure (CHF) patients with indications for primary prevention of sudden cardiac death (SCD) in China and the effects of cardiac resynchronization therapy (CRT)-pacemaker (P) and CRT-defibrillator (D) implantation on the clinical prognosis of CHF among patients undergoing CRT. METHODS AND RESULTS: Overall, 798 consecutive patients who had devices implanted (implantable cardioverter defibrillator: 199, CRT-D: 362, and CRT-P: 237) from May 2012 to July 2013 in POSCD-China, a multicentric prospective cohort study, were enrolled. The primary endpoint was all-cause death, and the secondary endpoint was SCD. In total, 71.3% of patients had non-ischaemic CHF. The mean follow-up time was 27.7 ± 12.0 months, and death occurred in 158 cases, with 35 cases of SCD. CHF was the main cause of death (68.4%), followed by sudden death (22.2%). In the CRT-P group, the SCD rate was 8.0%, which was much higher than that in the CRT-D (3.3%) and implantable cardioverter defibrillator (2.0%) groups. No significant differences were identified in the all-cause death rate between the CRT-D and CRT-P groups (CRT-D vs. CRT-P, 20.4% vs. 19.4%, P = 0.840). CONCLUSIONS: In China, among CHF patients with indications for primary prevention of SCD who received device implantation, non-ischaemic CHF was the main aetiology, and the most important cause of death was heart failure. No differences in all-cause death were observed between the CRT-D and CRT-P groups, but the CRT-D group had a lower SCD rate than the CRT-P group.


Subject(s)
Defibrillators, Implantable , Heart Failure , Pacemaker, Artificial , Cardiac Resynchronization Therapy Devices , China/epidemiology , Heart Failure/complications , Heart Failure/therapy , Humans , Prospective Studies , Risk Factors
9.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 37(5): 741-748, 2020 Oct 25.
Article in Chinese | MEDLINE | ID: mdl-33140596

ABSTRACT

With the heavier burden of cardiovascular disease, an abundance of papers emerge every year in the research hotspots, which cover a wide range of types and content. In order to let readers interested in the cardiovascular field quickly understand the research hotspots and research frontier, it is necessary to sort out and summarize the research topic in time. According to the discipline classification, we screened papers in cardiovascular field from the Essential Science Indicators (ESI) hot papers published in 2019. Methods such as bibliometrics, statistical description, hierarchical induction, analysis and interpretation were used a step further to reveal the context and characteristics of research in the field of cardiovascular diseases, summarize the latest progress and development direction in this field, and provide information and hints for the expansion of future research directions. A total of 297 papers were finally included, which were mainly in the field of clinical medicine; The country with the most publications was the United States, while China ranked the fifth in terms of contribution; the research institution with the highest number of published papers was Harvard University; the New England Journal of Medicine (NEJM) has published the most papers, with contribution also from journals such as Circulation, Europe Heart Journal, JAMA, and Lancet. All the papers were categorized into disease burden, disease risk, drug treatment, device treatment and surgical treatment, clinical diagnosis, basic research and others, so as to review and summarize the research front in the field of cardiovascular diseases.


Subject(s)
Cardiovascular Diseases , Bibliometrics , China , Humans , United States
10.
Ann Med ; 52(7): 361-366, 2020 11.
Article in English | MEDLINE | ID: mdl-32716217

ABSTRACT

BACKGROUND: Comorbidities are commonly seen in patients with coronavirus disease 2019 (COVID-19), but the clinical implication is not yet well-delineated. We aim to characterize the prevalence and clinical implications of comorbidities in patients with COVID-19. METHODS: This is a retrospective multi-centre study involving patients admitted between January 16th and March 10th 2020. The composite endpoint was defined as the presence of at least one of the following, intensive care unit (ICU) admission, or the need for mechanical ventilation, or death. RESULTS: A total of 472 consecutive cases admitted to 51 certified COVID-19 tertiary care hospitals were enrolled (median age was 43 [32-53.5] years and 53.0% were male). There were 101 (21.4%) patients presented with comorbidities, including hypertension (15.0%), diabetes mellitus (7.8%), coronary artery disease (2.6%), chronic obstructive pulmonary disease (1.3%) and cerebrovascular disease (1.9%). The composite endpoint occurred in 65 (13.8%) patients. Multivariate stepwise logistic regression analysis indicated that older age (odds ratio [OR] 1.39, 95% confidence interval (CI) 1.05-1.85, per 10-year increment), antecedent hypertension (OR 2.82, 95% CI 1.09-7.29), neutrophil counts (OR 1.33, 95% CI 1.14-1.56) and lactate dehydrogenase level (OR 1.01, 95% CI 1.00-1.01) were independently associated with the presence of composite endpoint. Hypertensive patients, compared with controls, had a greater chance of experiencing the composite endpoint (p < .001) and each individual endpoint, i.e. ICU admission (p < .001), mechanical ventilation (p < .001) and death (p = .012). In the stepwise regression analysis of anti-hypertensive medications, none of the therapy predicted the composite endpoint. CONCLUSIONS: Hypertension is a common comorbidity in patients with COVID-19 and associated with adverse outcomes. KEY MESSAGES Hypertension was identified as the comorbidity associated with the prognosis of COVID-19 in this retrospective cohort. Patients with hypertension could experience an increased risk of the composite endpoint. Anti-hypertensive therapy did not affect patient outcomes.


Subject(s)
Coronavirus Infections/epidemiology , Hospitalization/statistics & numerical data , Hypertension/epidemiology , Intensive Care Units/statistics & numerical data , Pneumonia, Viral/epidemiology , Adult , Aged , Antihypertensive Agents/administration & dosage , COVID-19 , Cohort Studies , Comorbidity , Female , Humans , Hypertension/drug therapy , Male , Middle Aged , Pandemics , Prognosis , Retrospective Studies , Risk Factors
11.
J Interv Cardiol ; 2020: 8249497, 2020.
Article in English | MEDLINE | ID: mdl-32523474

ABSTRACT

BACKGROUND: Paravalvular leak (PVL) is common after transcatheter aortic valve implantation (TAVI) and has been linked with worse survival. This study aimed to investigate the determinants and outcome of PVL after TAVI and determine the role of aortic valve calcification (AVC) distribution in predicting PVL. METHODS AND RESULTS: This was a retrospective cohort study of 270 consecutive patients who underwent TAVI. Determinants and outcomes of ≥mild PVL were assessed. Matching rates of PVL jet with AVC distribution were calculated. AVC volume, larger annulus dimensions, and transvalvular peak velocity were risk factors for ≥mild PVL after TAVI. AVC volume was an independent predictor of ≥mild PVL. On the other hand, annulus ellipticity, left ventricular outflow tract nontubularity, and diameter-derived prosthesis mismatch were not found to predict PVL after TAVI. PVL jet matched, in varying proportions, with calcification at all aortic root regions, and the highest matching rate was with calcifications at body of leaflets. Moreover, matching rates were less with commissure compared to cusp calcifications. Mild or greater PVL was not associated with all-cause and cardiovascular mortality up to 1-year follow-up. CONCLUSION: ≥mild PVL after TAVI is common and can be predicted by aortic root calcification volume, larger annulus dimensions, and pre-TAVI transvalvular peak velocity, with calcification volume being an independent predictor for PVL. However, annulus ellipticity, left ventricular outflow tract nontubularity, and diameter-derived prosthesis mismatch had no role in predicting PVL. Importantly, body of leaflet calcifications (versus annulus and tip of leaflet) and cusp calcifications (versus commissure calcification) are more important in predicting PVL. No association between ≥mild PVL and increased risk of all-cause and cardiovascular mortality at 1-year follow-up.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/complications , Aortic Valve/pathology , Calcinosis/complications , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/mortality , Female , Heart Valve Prosthesis/adverse effects , Humans , Incidence , Male , Retrospective Studies , Risk Factors
12.
Heart ; 106(15): 1154-1159, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32354798

ABSTRACT

OBJECTIVE: We sought to explore the prevalence and immediate clinical implications of acute myocardial injury in a cohort of patients with COVID-19 in a region of China where medical resources are less stressed than in Wuhan (the epicentre of the pandemic). METHODS: We prospectively assessed the medical records, laboratory results, chest CT images and use of medication in a cohort of patients presenting to two designated covid-19 treatment centres in Sichuan, China. Outcomes of interest included death, admission to an intensive care unit (ICU), need for mechanical ventilation, treatment with vasoactive agents and classification of disease severity. Acute myocardial injury was defined by a value of high-sensitivity troponin T (hs-TnT) greater than the normal upper limit. RESULTS: A total of 101 cases were enrolled from January to 10 March 2020 (average age 49 years, IQR 34-62 years). Acute myocardial injury was present in 15.8% of patients, nearly half of whom had a hs-TnT value fivefold greater than the normal upper limit. Patients with acute myocardial injury were older, with a higher prevalence of pre-existing cardiovascular disease and more likely to require ICU admission (62.5% vs 24.7%, p=0.003), mechanical ventilation (43.5% vs 4.7%, p<0.001) and treatment with vasoactive agents (31.2% vs 0%, p<0.001). Log hs-TnT was associated with disease severity (OR 6.63, 95% CI 2.24 to 19.65), and all of the three deaths occurred in patients with acute myocardial injury. CONCLUSION: Acute myocardial injury is common in patients with COVID-19 and is associated with adverse prognosis.


Subject(s)
Betacoronavirus , Coronavirus Infections/epidemiology , Pneumonia, Viral/epidemiology , Troponin T/blood , Adult , Age Factors , Angiotensin Receptor Antagonists/therapeutic use , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Biomarkers/blood , C-Reactive Protein/analysis , COVID-19 , Cardiovascular Agents/therapeutic use , China/epidemiology , Cohort Studies , Glomerular Filtration Rate , Humans , Intensive Care Units/statistics & numerical data , Middle Aged , Natriuretic Peptide, Brain/blood , Pandemics , Peptide Fragments/blood , Prognosis , SARS-CoV-2 , Severity of Illness Index
13.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Article in English | MEDLINE | ID: mdl-31943783

ABSTRACT

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Subject(s)
Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/instrumentation , Bicuspid Aortic Valve Disease/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/physiopathology , Female , Humans , Male , Pilot Projects , Postoperative Complications/etiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
14.
JACC Cardiovasc Interv ; 12(12): 1164-1171, 2019 06 24.
Article in English | MEDLINE | ID: mdl-31221307

ABSTRACT

OBJECTIVES: The authors sought to better understand the stent geometry of the Lotus valve after transcatheter aortic valve replacement (TAVR) and its potential implications for valve size selection. BACKGROUND: The authors hypothesized that the greatest interference between the frame and aortic valvar complex occurs across the aortic valve leaflets. METHODS: The authors retrospectively analyzed the multidetector computed tomography (MDCT) scans of 32 consecutive patients undergoing Lotus valve (Boston Scientific, Natick, Massachusetts) implantation. The prosthesis cross section was analyzed at 3-mm increments along its length. The plane where the frame had the smallest area was defined as the waist. The corresponding plane of the waist on pre-procedural MDCT was identified by surrounding structures such as calcium deposits, commissural fusion, and commissural gaps, and was referred to as the supra-annulus. The spline of the supra-annulus was circumscribed with reference to the post-implant stent geometry at the waist. RESULTS: The waist was 5.8 ± 1.7 mm higher than the native annulus on post-procedural MDCT. The waist had a nearly 2-fold larger compression rate than the stent at the native annulus level (36.3 ± 10.4% vs. 18.9 ± 9.6%; p < 0.01), irrespective of valve morphologies. The supra-annulus was 5.9 ± 1.6 mm higher than the annulus on pre-procedural MDCT. Patients had an approximately 17% decrease in area from the annulus to the supra-annulus (18.3 ± 4.4% for bicuspid morphology and 16.0 ± 3.5% for tricuspid morphology). CONCLUSIONS: Major interference between the implanted prosthesis and anatomy occurred at a level above the annulus. The decrease in area from the annulus to supra-annulus may explain the feasibility of implanting a smaller valve than that suggested by traditional annular measurements.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Stents , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Female , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Humans , Male , Multidetector Computed Tomography , Prosthesis Design , Retrospective Studies , Treatment Outcome
16.
J Interv Cardiol ; 31(6): 878-884, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30079561

ABSTRACT

BACKGROUND: Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices. METHODS: A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected. RESULTS: The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%. CONCLUSIONS: Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.


Subject(s)
Aortic Valve/abnormalities , Arrhythmias, Cardiac/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis/adverse effects , Pacemaker, Artificial/statistics & numerical data , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve/surgery , Arrhythmias, Cardiac/etiology , Bicuspid Aortic Valve Disease , Female , Humans , Incidence , Male , Multidetector Computed Tomography , Retrospective Studies , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
17.
Int J Cardiovasc Imaging ; 34(11): 1761-1767, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29915878

ABSTRACT

To compare reverse left ventricular (LV) remodeling after transcatheter aortic valve replacement (TAVR) between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). We retrospectively reviewed data of patients with at least two serial echocardiographic follow-ups (1, 3, 6 months and 1 year) post-TAVR. A total of 116 patients were identified. BAV morphology was documented in 67 patients. LV mass index (LVMi) at baseline was not significantly different between the TAV and BAV group (178.0 ± 6.9 vs. 166.3 ± 6.4 g/m2, P = 0.14). Reverse LV remodeling was observed in both BAV and TAV patients, but the reduction of LVMi from baseline was significantly more pronounced in TAV patients compared with BAV patients from 6 months post-TAVR (- 56.3 ± 8.1 vs. - 30.0 ± 4.7 g/m2, P < 0.01 at 6-month follow-up; - 60.6 ± 7.6 vs. - 37.9 ± 6.2 g/m2, P = 0.02 at 1-year follow-up). EDV value changes during follow-up were similar between patient with TAV and BAV. There were no significant differences in the proportions of patients with more than mild PVL or new permanent pacemaker between TAV and BAV morphology throughout the follow-up. Patients with bicuspid morphology might experience less pronounced reverse LV remodeling post-TAVR than patients with tricuspid morphology.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/abnormalities , Heart Valve Diseases/surgery , Transcatheter Aortic Valve Replacement , Ventricular Function, Left , Ventricular Remodeling , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/physiopathology , Bicuspid Aortic Valve Disease , Echocardiography , Female , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Humans , Male , Retrospective Studies , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
EuroIntervention ; 13(15): e1756-e1763, 2018 02 02.
Article in English | MEDLINE | ID: mdl-29039313

ABSTRACT

AIMS: Limited information exists describing the results of transcatheter aortic valve replacement (TAVR) in patients with symptomatic severe non-calcific aortic stenosis (AS). We aimed to compare procedural, echocardiographic, and clinical outcomes among patients with non-calcific AS with those of senile calcific AS undergoing TAVR. METHODS AND RESULTS: We retrospectively identified patients with non-calcific AS who received TAVR with self-expanding transcatheter heart valves in our centre. Clinical and echocardiographic outcomes, and post-procedural multi-detector computed tomography (MDCT) measures were compared to those in patients undergoing TAVR for calcific AS. Among 136 patients, 21 patients (15.4%) with native leaflet thickening and minimal calcification were identified (non-calcific group). The patients were significantly younger in the non-calcific group (70.0 [64.0-75.5] vs. 75.0 [69.0-78.0] years) with comparable STS-PROM scores (6.7 [4.8-8.9] vs. 8.2 [4.8-10.9] %). Predilation was performed less frequently (42.9% vs. 93.9%) and post-dilation more often (71.4% vs. 42.6%) in the non-calcific group. Both 30-day and one-year mortality were similar between groups (0% vs. 7.8% and 0% vs. 17.6%). Rates of post-implantation paravalvular leak ≥mild at six months (17.6% vs. 25.7%) were comparable despite lower implantation depth among non-calcific AS patients (10.9±5.7 vs. 7.2±4.3 mm) on post-implantation MDCT. CONCLUSIONS: TAVR with self-expanding transcatheter heart valves appears to be safe and effective in patients with non-calcific AS.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty , Echocardiography , Female , Heart Valve Prosthesis , Hemodynamics , Humans , Male , Middle Aged , Multidetector Computed Tomography , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
19.
Int J Cardiol ; 254: 69-74, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29246428

ABSTRACT

BACKGROUND: Limited date describing the procedural, clinical and valve performance results of transcatheter aortic valve replacement (TAVR) in patients with bicuspid versus tricuspid aortic stenosis (TAV). METHODS: Procedural and clinical results were defined and reported according to VARC-2 criteria. RESULTS: Consecutive 87 patients with BAV and 70 patients with TAV were included. Compared to patients with TAV, patients with BAV had similar incidence of second valve implantation (14.9% vs 12.9%, p=0.708), more than mild paravalvular leakage (PVL, 40.2% vs 31.9%, p=0.288), permanent pacemaker implantation (PPM, 24.1% vs 28.6%, p=0.53). Furthermore, the procedural and clinical results of TAVR also did not differ between patients with type 0 and type 1 (second valve implantation: 18.4% vs 11.8%, p=0.71, PVL: 38.8% vs 41.2%, p=0.83, PPM: 18.4% vs 31.6%, p=0.16). The hemodynamic outcomes were similar in patients with BAV and TAV at 1-year (maximum velocity, 2.3 vs 2.2m/s, p=0.307) and 2-year (2.3 vs 2.1m/s, p=0.184) follow-up respectively. Adjusted binary logistic regression analysis found oversizing ratio at 14.45-20.57% is at lower risk for more than mild PVL (OR, 0.069, 95% CI, 0.011-0.428, p=0.004). Moreover, the Kaplan-Meier survival analysis revealed that TAVR in type 0 BAV, type 1 BAV and TAV have comparable risk for midterm mortality (Log rank, p=0.772). CONCLUSION: TAVR in whatever type of BAV appeared to be safe and efficacy, and TAVR in BAV was associated with comparable bioprosthetic function during follow up compared to patients with TAV.


Subject(s)
Bicuspid/diagnostic imaging , Bicuspid/surgery , Multidetector Computed Tomography/methods , Transcatheter Aortic Valve Replacement/methods , Tricuspid Valve Stenosis/diagnostic imaging , Tricuspid Valve Stenosis/surgery , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Multidetector Computed Tomography/trends , Transcatheter Aortic Valve Replacement/trends , Treatment Outcome
20.
Sci Rep ; 7(1): 15014, 2017 11 08.
Article in English | MEDLINE | ID: mdl-29118326

ABSTRACT

The aim of this study was to investigate the incidence, predictors and outcome of prosthesis-patient mismatch (PPM) following transcatheter aortic valve replacement (TAVR). A total of 30 articles incorporating 4,691 patients were identified. The pooled incidences of overall, moderate and severe PPM following TAVR were 33.0%, 25.0% and 11.0% respectively. Medtronic CoreValve (MCV) had lower incidence of overall (32% vs: 40%, P < 0.0001) and moderate (23% vs 32%, P < 0.0001) than Edwards Sapien (ESV). PPM was associated with a younger age, smaller annulus diameter and lower left ventricular ejection fraction in comparison with those patients without PPM. Post-dilation (OR, 0.51, 95% CI, 0.38 to 0.68, p < 0.001) during TAVR would decrease the incidence of PPM. Although PPM was common after TAVR, no significant differences were observed both in short- and mid-term all-cause mortality (30 day: OR: 1.1, 95% CI, 0.70 to 1.73 and 2 year: OR: 1.01, 95% CI, 0.74 to 1.38) between patients with PPM and those without PPM. In conclusion, despite being common after TAVR, the incidence of PPM was lower than that of surgical aortic valve replacement (SAVR) and decreased with the experience accumulating, and PPM was not seen to impact on short- and mid-term survival, regardless of its magnitude.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis/standards , Postoperative Complications/diagnosis , Transcatheter Aortic Valve Replacement/methods , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Incidence , Kaplan-Meier Estimate , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prognosis , Prosthesis Failure , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...