Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pol J Radiol ; 89: e240-e248, 2024.
Article in English | MEDLINE | ID: mdl-38938658

ABSTRACT

Purpose: To assess the effectiveness of contrast-enhanced mammography (CEM) recombinant images in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population. Material and methods: 792 patients with 808 breast lesions, in whom the final decision on core-needle biopsy was made based on CEM, and who received the result of histopathological examination, were qualified for a single-centre, retrospective study. Patient electronic records and imaging examinations were reviewed to establish demographics, clinical and imaging findings, and histopathology results. The CEM images were reassessed and assigned to the appropriate American College of Radiology (ACR) density categories. Results: Extremely dense breasts were present in 86 (10.9%) patients. Histopathological examination confirmed the presence of malignant lesions in 52.6% of cases in the entire group of patients and 43% in the group of extremely dense breasts. CEM incorrectly classified the lesion as false negative in 16/425 (3.8%) cases for the whole group, and in 1/37 (2.7%) cases for extremely dense breasts. The sensitivity of CEM for the group of all patients was 96.2%, specificity - 60%, positive predictive values (PPV) - 72.8%, and negative predictive values (NPV) - 93.5%. In the group of patients with extremely dense breasts, the sensitivity of the method was 97.3%, specificity - 59.2%, PPV - 64.3%, and NPV - 96.7%. Conclusions: CEM is characterised by high sensitivity and NPV in detecting malignant lesions regardless of the type of breast density. In patients with extremely dense breasts, CEM could serve as a complementary or additional examination in the absence or low availability of MRI.

2.
Eur J Radiol ; 167: 111062, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37643559

ABSTRACT

PURPOSE: Analysis of the morphology of lesions classified into the BI-RADS 4 category and assessment of the possibility of downgrade the BI-RADS category in those that did not show enhancement on recombinant contrast-enhanced mammography (CEM) images. METHOD: The retrospective, single-center study included 528 patients who underwent a core needle biopsy performed from January 2017 to November 2022 due to a breast lesion classified as BI-RADS 4 on CEM. Patients' electronic records and imaging examinations were reviewed. Individual lesions were classified into the morphological categories of mass, non-mass, and microcalcifications. Sensitivity, specificity, positive as well as negative predictive values were calculated for the whole group and individual morphological categories. The influence of the lesions' diameter on the results was analyzed. RESULTS: CEM NPV for the whole group was 93.9% (±95% CI: 90.0-96.4), for mass lesions 100% (±95% CI: 94.5-100), for non-mass lesions 97.8% (±95% CI: 87.0-99.9) and 87.9% (±95% CI: 80.3-93.0) for microcalcifications. Given that 230 out of 383 benign lesions were not contrast-enhancing, 60.1% of unnecessary CNBs would have been correctly avoided. CEM sensitivity for lesions < 20 mm was lower than for lesions ≥ 20 mm and was respectively 86.6% (±95% CI: 76.8-92.8) vs 94.6% (±95% CI: 86.0-98.2), respectively. CONCLUSION: CEM is characterized by high sensitivity in the detection of malignant lesions in the case of lesions with mass and non-mass morphology. The high NPV for recombinant images suggests that in the case of these lesions, the lack of enhancement supports the benign nature of the lesion and may lead to a downgrade of the BI-RADS category.


Subject(s)
Breast Neoplasms , Calcinosis , Humans , Female , Retrospective Studies , Mammography , Physical Examination , Calcinosis/diagnostic imaging , Breast Neoplasms/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...